Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Circulation ; 149(17): 1341-1353, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38235580

RESUMO

BACKGROUND: Cardiolipin is a mitochondrial-specific phospholipid that maintains integrity of the electron transport chain (ETC) and plays a central role in myocardial ischemia/reperfusion injury. Tafazzin is an enzyme that is required for cardiolipin maturation. Venoarterial extracorporeal membrane oxygenation (VA-ECMO) use to provide hemodynamic support for acute myocardial infarction has grown exponentially, is associated with poor outcomes, and is under active clinical investigation, yet the mechanistic effect of VA-ECMO on myocardial damage in acute myocardial infarction remains poorly understood. We hypothesized that VA-ECMO acutely depletes myocardial cardiolipin and exacerbates myocardial injury in acute myocardial infarction. METHODS: We examined cardiolipin and tafazzin levels in human subjects with heart failure and healthy swine exposed to VA-ECMO and used a swine model of closed-chest myocardial ischemia/reperfusion injury to evaluate the effect of VA-ECMO on cardiolipin expression, myocardial injury, and mitochondrial function. RESULTS: Cardiolipin and tafazzin levels are significantly reduced in the left ventricles of individuals requiring VA-ECMO compared with individuals without VA-ECMO before heart transplantation. Six hours of exposure to VA-ECMO also decreased left ventricular levels of cardiolipin and tafazzin in healthy swine compared with sham controls. To explore whether cardiolipin depletion by VA-ECMO increases infarct size, we performed left anterior descending artery occlusion for a total of 120 minutes followed by 180 minutes of reperfusion in adult swine in the presence and absence of MTP-131, an amphipathic molecule that interacts with cardiolipin to stabilize the inner mitochondrial membrane. Compared with reperfusion alone, VA-ECMO activation beginning after 90 minutes of left anterior descending artery occlusion increased infarct size (36±8% versus 48±7%; P<0.001). VA-ECMO also decreased cardiolipin and tafazzin levels, disrupted mitochondrial integrity, reduced electron transport chain function, and promoted oxidative stress. Compared with reperfusion alone or VA-ECMO before reperfusion, delivery of MTP-131 before VA-ECMO activation reduced infarct size (22±8%; P=0.03 versus reperfusion alone and P<0.001 versus VA-ECMO alone). MTP-131 restored cardiolipin and tafazzin levels, stabilized mitochondrial function, and reduced oxidative stress in the left ventricle. CONCLUSIONS: We identified a novel mechanism by which VA-ECMO promotes myocardial injury and further identify cardiolipin as an important target of therapy to reduce infarct size and to preserve mitochondrial function in the setting of VA-ECMO for acute myocardial infarction.

2.
J Card Fail ; 29(3): 290-303, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36513273

RESUMO

INTRODUCTION: Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is a prevailing option for the management of severe early graft dysfunction. This systematic review and individual patient data (IPD) meta-analysis aims to evaluate (1) mortality, (2) rates of major complications, (3) prognostic factors, and (4) the effect of different VA-ECMO strategies on outcomes in adult heart transplant (HT) recipients supported with VA-ECMO. METHODS AND RESULTS: We conducted a systematic search and included studies of adults (≥18 years) who received VA-ECMO during their index hospitalization after HT and reported on mortality at any timepoint. We pooled data using random effects models. To identify prognostic factors, we analysed IPD using mixed effects logistic regression. We assessed the certainty in the evidence using the GRADE framework. We included 49 observational studies of 1477 patients who received VA-ECMO after HT, of which 15 studies provided IPD for 448 patients. There were no differences in mortality estimates between IPD and non-IPD studies. The short-term (30-day/in-hospital) mortality estimate was 33% (moderate certainty, 95% confidence interval [CI] 28%-39%) and 1-year mortality estimate 50% (moderate certainty, 95% CI 43%-57%). Recipient age (odds ratio 1.02, 95% CI 1.01-1.04) and prior sternotomy (OR 1.57, 95% CI 0.99-2.49) are associated with increased short-term mortality. There is low certainty evidence that early intraoperative cannulation and peripheral cannulation reduce the risk of short-term death. CONCLUSIONS: One-third of patients who receive VA-ECMO for early graft dysfunction do not survive 30 days or to hospital discharge, and one-half do not survive to 1 year after HT. Improving outcomes will require ongoing research focused on optimizing VA-ECMO strategies and care in the first year after HT.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Transplante de Coração , Adulto , Humanos , Oxigenação por Membrana Extracorpórea/métodos , Transplante de Coração/efeitos adversos , Mortalidade Hospitalar , Alta do Paciente , Estudos Retrospectivos
3.
J Cardiothorac Vasc Anesth ; 37(8): 1418-1423, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37173169

RESUMO

OBJECTIVES: To evaluate the association of pulmonary artery diameter and pulmonary artery- to-aorta diameter ratio (PA/Ao) with right ventricular failure and mortality within 1 year after left ventricular assist device implantation. DESIGN: This was a retrospective observational study between March 2013 and July 2019. SETTING: The study was conducted at a single, quaternary-care academic center. PARTICIPANTS: Adults (≥18 years old) receiving a durable left ventricular assist device (LVAD). Inclusion if (1) a chest computed tomography scan was performed within 30 days before the LVAD and (2) a right and left heart catheterization was completed within 30 days before the LVAD. INTERVENTIONS: A left ventricular assist device was used for intervention. MEASUREMENTS AND MAIN RESULTS: A total of 176 patients were included in this study. Median PA diameter and PA/Ao ratio were significantly greater in the severe right ventricular failure (RVF) group (p = 0.001, p < 0.001, respectively). Receiver operating characteristic analysis revealed PA/Ao and RVF as predictors for mortality (area under the curve = 0.725 and 0.933, respectively). Logistic regression analysis-predicted probability gave a PA/Ao ratio cutoff point of 1.04 (p < 0.001). Survival probability was significantly worse in patients with a PA/Ao ratio ≥1.04 (p = 0.005). CONCLUSIONS: The PA/Ao ratio is an easily measurable noninvasive indicator that can predict RVF and 1-year mortality after LVAD implantation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Adulto , Humanos , Adolescente , Artéria Pulmonar/diagnóstico por imagem , Fatores de Risco , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/cirurgia , Estudos Retrospectivos , Aorta
4.
Clin Transplant ; 36(4): e14584, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34994988

RESUMO

BACKGROUND: Ischemic time (IT) under the new heart transplant (HTx) allocation system has increased compared to the old system. We investigated the effect of IT and donor age on post-HTx survival. METHODS: The United Network for Organ Sharing (UNOS) database was analyzed to identify adult HTx between October 2015 and August 2020. Recipients were stratified by donor age, transplantation era, and IT. Kaplan-Meier and log-rank tests were used to compare 180-day post-HTx mortality. Cox proportional hazards modeling and propensity score matching were performed to adjust for confounders. RESULTS: Under the new system (N = 3654), IT≥4 h led to decreased survival compared to IT < 4 h (91.4% vs. 93.7%; P = .02), although this decrease was undetectable among those with donors ≥39 years old (90.4% vs. 91.1%; P = .73). IT≥4 h led to decreased survival with donors < 39 years old (91.7% vs. 94.6%; P < .01). Under the old system (N = 5987), IT≥4 h resulted in decreased survival (89.8% vs. 93.9%; P < .01), including with donors ≥39 years old (86.9% vs. 92.4%; P < .01). CONCLUSIONS: IT≥4 h remains a risk for post-HTx mortality under the new system. However, the magnitude of this effect is blunted when donor age is ≥39 years, likely secondary to increased allocation of these organs to lower status, more stable recipients.


Assuntos
Transplante de Coração , Adulto , Bases de Dados Factuais , Sobrevivência de Enxerto , Humanos , Estudos Retrospectivos , Doadores de Tecidos
5.
J Cardiothorac Vasc Anesth ; 36(8 Pt B): 3318-3326, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35545462

RESUMO

Mechanical circulatory support (MCS) is used in cardiogenic shock for periprocedural hemodynamic stability in high-risk patients and to support patients with symptomatic coronary artery disease. Depending on the MCS type, oxygenation and ventilation, in addition to increasing blood pressure by augmenting blood flow, can be achieved. MCS typically follows a failure of less invasive maneuvers or intolerance to them, such as significant ventricular arrhythmia burden from inotropic support. MCS options include intra-aortic balloon pump, transvalvular percutaneous left ventricular assist devices, venoarterial extracorporeal membrane oxygenation, and surgically implanted left ventricular assist devices. The number of MCS options has increased, and this has made the decision-making process complicated. MCS decision-making is complex, even in patients without valvular pathology. The presence of aortic valve (AV) abnormalities, such as aortic stenosis, aortic insufficiency, replaced AVs, or AV masses, adds even further to the challenge of selecting the appropriate support strategy. In this narrative review, a concise review of MCS options and the special considerations for various AV pathologies are presented.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Valva Aórtica/cirurgia , Oxigenação por Membrana Extracorpórea/efeitos adversos , Coração Auxiliar/efeitos adversos , Humanos , Balão Intra-Aórtico/efeitos adversos , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia
6.
J Card Surg ; 37(4): 1052-1055, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34989464

RESUMO

Given the increased need for mechanical circulatory support and subsequent development of right ventricular assist devices (RVAD), appropriate imaging needs to be described to facilitate care in patients with cardiogenic shock and heart failure. We present three cases in which the upper esophageal aortic arch short axis (UE AA SAX) view on transesophageal echocardiography (TEE) was utilized to effectively image RVADs: to confirm normal positioning, to detect and guide repositioning, and to visualize malfunction. These cases support the importance of the UE AA SAX TEE view in RVAD outflow imaging and, when obtainable, should be included in routine RVAD assessment.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Ecocardiografia Transesofagiana , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Humanos , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 98(4): 767-773, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33979472

RESUMO

BACKGROUND: Carotid access has shown promise as an excellent delivery route for transcatheter aortic valve replacement (TAVR). We aimed to compare outcomes of transcarotid (TC) and transfemoral (TF) TAVR by conducting a search and analysis of the best evidence in the literature to shed light on its safety and effectiveness. METHODS: The PubMed/MEDLINE, Embase, and Cochrane library from inception to July 2020 were searched to identify articles reporting comparative data on TC versus TF approaches for TAVR. Patients' baseline characteristics and clinical outcomes were extracted from the articles and pooled for analysis. RESULTS: Five studies, including a total of 2470 patients, were included in the study with 1859 patients in the TF group and 611 patients in the TC group. The TC group had higher prevalence of peripheral vascular disease, while the patients in the TF group was older. Meta-analysis revealed that there was no significant differences between the two groups with regard to 30-day mortality (p = 0.09), stroke (p = 0.28), new dialysis (p = 0.58), major bleeding (p = 0.69), or pacemaker implantation (p = 0.44). The TF group had a higher incidence of vascular complications (3.9% vs. 2.3%; OR 2.22; 95% CI [1.13, 4.38]; p = 0.02). CONCLUSIONS: Compared with the TF approach, TC-TAVR is associated with comparable procedural and clinical outcomes. Our analysis found a lower rate of vascular complication in TC access compared with TF access. This supports consideration of such an alternative access when there are concerns over the feasibility of TF access.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Artéria Femoral/cirurgia , Humanos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
J Cardiothorac Vasc Anesth ; 35(9): 2694-2699, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33455885

RESUMO

OBJECTIVE: The treatment of refractory vasodilatory shock in patients undergoing extracorporeal membrane oxygenation (ECMO) is an area in which there is minimal literature. Based on previous literature, the authors hypothesized that at least 40% of ECMO patients with vasoplegia would respond positively to methylene blue (MB) administration and that those who responded to MB would have increased survival. DESIGN: Retrospective observational study. SETTING: Single institution, quaternary care hospital. PARTICIPANTS: The study comprised 45 patients who received MB for vasoplegia during ECMO. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Of the 45 patients who received MB, 25 patients (55.6%) experienced a ≥10% increase in mean arterial pressure (MAP) and a reduction in norepinephrine dosing in the one-to-two hour interval after MB administration. There was a trend for improvement in survival to discharge for those who responded to MB (32% v 10%; p = 0.15). In addition, patients who did not have at least a >5% increase in MAP (29 experienced a >5% increase and 16 experienced a ≤5% increase) after MB administration, experienced 100% mortality (p = 0.008). CONCLUSION: This study suggested that approximately 50% of ECMO patients with vasoplegia can be expected to respond to MB with a >10% MAP improvement. The lack of a blood pressure response >5% after MB administration may portend poor survival. Larger prospective studies are needed to verify these preliminary results.


Assuntos
Oxigenação por Membrana Extracorpórea , Vasoplegia , Oxigenação por Membrana Extracorpórea/efeitos adversos , Humanos , Azul de Metileno , Estudos Prospectivos , Estudos Retrospectivos , Choque Cardiogênico , Vasoplegia/tratamento farmacológico
9.
J Artif Organs ; 24(3): 365-367, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33098044

RESUMO

The HeartMate 3 [HM3 (Abbott, Abbott Park, Illinois)] is a left-ventricular assist device (LVAD) with excellent clinical results. Outflow graft occlusion as a complication secondary to outflow graft twisting was reported to occur in 1.6% within the MOMENTUM 3 trial. The anti-twist metal clip or modified bend relief is made to prevent this complication currently, however, there remain large numbers of early implanted HM3 which may develop this complication. There are limited reports illustrating diagnosis, surgical repair, and post-repair hemodynamic changes of these complications. Thus, we present a case of successful diagnosis and surgical repair of an outflow graft twist. Simple procedure through thoracotomy without cardiopulmonary bypass provides significant immediate hemodynamic improvement.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Hemodinâmica , Humanos , Complicações Pós-Operatórias , Toracotomia
10.
J Artif Organs ; 24(3): 312-319, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33740155

RESUMO

Left ventricular assist device (LVAD) implantations have traditionally been approached through a full median sternotomy (FS). Recently, a minimally invasive left thoracotomy (LT) approach has been popularized. This study sought to compare the outcomes of FS and LT patients post-primary LVAD implantation and post-subsequent heart transplant (HT). This was a single-center retrospective study. 83 patients who underwent primary centrifugal durable LVAD implantation from January 2014 to June 2018 were included (FS, n = 41; LT, n = 42). 41 patients had a subsequent HT (FS, n = 19; LT, n = 22). Pre-operative patient demographics, intraoperative variables, post-operative 1-year survival, length of hospital stay, complications, and outcomes for LVAD implantation and following HT were analyzed. Intraoperative data showed that the LT group had a 23.4% longer mean LVAD implant surgical time (p < 0.01). One-year post-LVAD survival was similar between the two groups (p = 0.05). Complication rates, with the exception of the rate of hemorrhagic stroke (p = 0.04) post-LVAD implant were similar. One-year survival post-HT was similar between groups (p = 0.35). Complication rates and mean length of hospital stay were also similar (p = 1.0) post-HT. Our study demonstrated that LT approach does not negatively affect post-LVAD implantation or post-HT outcomes. Further, larger studies may determine more detailed effects of LT approach.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Insuficiência Cardíaca/cirurgia , Humanos , Implantação de Prótese , Estudos Retrospectivos , Esternotomia/efeitos adversos , Toracotomia , Resultado do Tratamento
11.
J Card Surg ; 36(12): 4783-4785, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34599529

RESUMO

BACKGROUND: Acute decompensated heart failure in patients with coronavirus disease 2019 (COVID-19) is becoming increasingly common. AIMS: In this case report, we describe the successful use of an Impella 5.5 (Abiomed) to treat cardiogenic shock refractory to inotropic therapy. MATERIALS & METHODS: Transthoracic and transesophageal echocardiography confirmed severely diminished left ventricular ejection fraction and a reverse-transcription polymerase chain reaction test revealed that the patient was COVID-19 positive during his hospital admission. RESULTS: Following initiation of inotropic therapy, we placed an Impella 5.5 for further cardiac support. The patient's LVEF and cardiac index improved after 21 days on the Impella 5.5 and was maintained following explant. DISCUSSION & CONCLUSION: The findings reported here demonstrate successful use of an Impella 5.5 to improve native heart function in refractory cardiogenic shock and further indicate its use as an option for those in acute decompensated heart failure who have tested positive for COVID-19 infection.


Assuntos
COVID-19 , Coração Auxiliar , Humanos , Estudos Retrospectivos , SARS-CoV-2 , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
12.
J Card Fail ; 26(5): 394-401, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31981695

RESUMO

BACKGROUND: Elevated right atrial pressure (RAP) is associated with poor outcomes after left ventricular assist device (LVAD) implantation. However, the optimal time for RAP measurement and the importance of resolution of right heart congestion prior to LVAD implantation remain unclear. METHODS AND RESULTS: We performed a retrospective cohort study of 134 consecutive LVAD recipients from our institution. Congestion was defined as RAP ≥ 14 mmHg and was assessed at hospital admission and implant. The primary outcome was death or right ventricular assist device (RVAD) implantation. When stratified by congestion status at admission, congested and non-congested patients had similar event-free survival rates (hazard ratio [HR]: 1.2, 95% confidence interval [CI]: 0.6-2.6). However, when stratified at implant, congested patients had a higher rate death or RVAD implantation (HR: 2.5, 95% CI: 1.1-5.6). Patients were then divided into 4 groups based on their trajectory of congestion status: no congestion, resolved congestion, new congestion, or persistent congestion. Patients with no congestion and resolved congestion had similar outcomes, whereas patients with persistent congestion had a markedly increased rate of death or RVAD implantation (HR: 3.1, 95% CI: 1.3-7.6). CONCLUSION: RAP at LVAD implantation is more strongly associated with postoperative outcomes than admission RAP. Patients not responsive to decongestive therapies, with persistently elevated RAP, represent a high-risk cohort for adverse outcomes following LVAD implantation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Pressão Atrial , Insuficiência Cardíaca/epidemiologia , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Disfunção Ventricular Direita/epidemiologia
13.
J Cardiothorac Vasc Anesth ; 34(5): 1377-1379, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31917078

RESUMO

Myocardial infarctions may cause ventricular aneurysms. Ischemia-induced ventricular changes are more common in the left ventricle owing to the larger vascular supply, greater volume of myocardium, and increased intra-ventricular pressure. Ischemia-induced right ventricular free wall abnormalities are rare owing to the lower ventricular pressure. The authors describe the echocardiographic progression of a right ventricular ischemic aneurysm resulting from an ST-elevated myocardial infarction in a 71- year-old man. In this E-Challenge, the authors will review the echocardiographic findings and pathophysiology of ischemic aneurysms.


Assuntos
Aneurisma Cardíaco , Infarto do Miocárdio , Idoso , Ecocardiografia , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/etiologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio
14.
J Artif Organs ; 23(2): 140-146, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31713054

RESUMO

Primary graft dysfunction (PGD) is a rare complication associated with high mortality after heart transplantation, which may require veno-arterial extra-corporeal membrane oxygenation (VA-ECMO) support. A standardized definition for PGD was developed by the International Society of Heart and Lung Transplantation in 2014. Due to limited reports using this definition, the detailed outcomes after VA-ECMO support remain unclear. Therefore, we retrospectively analyzed our single-center outcomes of PGD following VA-ECMO support. Between September 2014 and August 2018, 160 patients underwent heart transplantation in our single center. Nine PGD patients required VA-ECMO support, with an incidence of 5.6%. Pre-operative recipient/donor demographics, intra-operative variables, timing of VA-ECMO initiation and support duration, graft function recovery during 30 days after heart transplant, VA-ECMO complications, and survival were analyzed. The indication for VA-ECMO support was biventricular failure for all nine patients. Six patients had severe PGD requiring intra-operative VA-ECMO, while two patients had moderate PGD and one patient had mild PGD requiring post-operative VA-ECMO. All cohorts were successfully decannulated in a median of 10 days. Survival to discharge rate was 88.9%. One-year survival rate was 85.7%. Left ventricular ejection fraction recovered to normal within 30 days in all PGD patients. Our study showed VA-ECMO support led to high survival and timely graft function recovery in all cohorts. Further larger research can clarify the detailed effects of VA-ECMO support which may lead to standardized indication of VA-ECMO support for PGD patients.


Assuntos
Oxigenação por Membrana Extracorpórea/mortalidade , Insuficiência Cardíaca/cirurgia , Transplante de Coração/efeitos adversos , Disfunção Primária do Enxerto/terapia , Adulto , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Disfunção Primária do Enxerto/mortalidade , Recuperação de Função Fisiológica/fisiologia , Estudos Retrospectivos , Taxa de Sobrevida
15.
Catheter Cardiovasc Interv ; 94(6): 854-855, 2019 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-31737990

RESUMO

Maladaptive left ventricular remodeling after acute myocardial infarction is defined by increased left ventricular dimensions and is associated with poor clinical outcomes. Left ventricular partitioning devices mechanically reduce left ventricular dimensions and are postulated to improve symptomatic heart failure. In this first in human study, deployment of the Heartech LVPD was shown to be feasible without a prohibitive safety signal precluding future pivotal trials.


Assuntos
Insuficiência Cardíaca , Infarto do Miocárdio , Ventrículos do Coração , Humanos , Resultado do Tratamento , Remodelação Ventricular
16.
J Cardiothorac Vasc Anesth ; 33(3): 844-849, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29880428

RESUMO

The management of patients presenting with bioprosthetic valve thrombosis presents a major clinical challenge from a diagnostic and management standpoint. This patient population becomes especially challenging to manage when presenting with cardiogenic shock and additional risks for bleeding. In this clinical conference, the authors present the case of a 64-year-old male who developed intraoperative bioprosthetic mitral valve thrombosis and cardiogenic shock necessitating support with venoarterial extracorporeal membrane oxygenation. The discussion focuses on the diagnostic challenges with transesophageal echocardiography and the difficulty in determining the proper approach to systemic anticoagulation.


Assuntos
Bioprótese/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Trombose/diagnóstico por imagem , Doença Aguda , Humanos , Masculino , Pessoa de Meia-Idade , Trombose/etiologia
17.
J Artif Organs ; 22(2): 91-97, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30361785

RESUMO

The effect of performing a concomitant mitral valve procedure (MVP) during continuous-flow left ventricular assist device (CF-LVAD) implantation has been reported for patients with moderate-to-severe mitral regurgitation (MR), but moderate MR is less of a clinical concern for CF-LVAD patients. There is a paucity of reports focusing on patients with severe MR. Thus, the purpose of this study was to analyze the effect of performing a concomitant MVP during CF-LVAD implantation in patients with severe preoperative MR. Between November 2003 and March 2016, 526 patients underwent primary implantation of a CF-LVAD at our center. Patients with severe MR who underwent a concomitant MVP were compared to those who did not in regard to overall survival, perioperative complications, postoperative echocardiography data, bridge-to-transplantation success, and CF-LVAD explantation. Of the 108 patients with severe MR, 26 underwent a concomitant MVP and 82 did not. These groups showed no difference in survival (p = 0.61). Additionally, the two groups had similar rates of postoperative right heart failure (p = 0.69) and readmissions (p = 0.42). The 24-month follow-up echocardiography results were also similar. Furthermore, the groups showed no difference in bridge-to-cardiac transplantation success (30.0% vs 25.0%, p = 0.80) or CF-LVAD explantation rates (0.0% vs 0.0%. p = 1.0). Our findings suggest that patients with severe MR who undergo a MVP during CF-LVAD implantation do not have superior outcomes to those who do not. However, assessments of other outcomes may show some benefits to performing concomitant MVPs.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Implantação de Prótese , Adulto , Idoso , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Texas/epidemiologia , Resultado do Tratamento
18.
J Card Surg ; 34(12): 1458-1464, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31730728

RESUMO

BACKGROUND: Study findings have been inconsistent regarding whether a concomitant tricuspid valve replacement or repair performed concurrently with continuous-flow left ventricular assist device (CF-LVAD) implantation has additive clinical benefit in patients with severe tricuspid valve regurgitation (TR). AIM OF STUDY: To determine the effect of performing a concomitant tricuspid valve procedure (TVP) at the time of CF-LVAD implantation on patient outcomes. METHODS: We retrospectively reviewed our single-institution experience in 526 patients who underwent primary implantation of a CF-LVAD between November 2003 and March 2016. We identified 59 (11.2%) patients who had severe TR at the time of implantation and analyzed the effect of performing a concomitant TVP at the time of CF-LVAD implantation on the rate of survival, incidence of postoperative right heart failure (RHF), recurrence of TR, and incidence of 30-day readmission. RESULTS: We did not observe a significant difference in the overall survival rate (P = .51), incidence of postoperative RHF (P = .26), or recurrence of TR (P = .73) between patients with severe TR who underwent a TVP and those who did not at the time of CF-LVAD implantation. However, the incidence of 30-day readmission was significantly lower in patients who underwent a TVP than in those who did not (P = .002). CONCLUSIONS: Performing a concomitant TVP at the time of CF-LVAD implantation did not improve patient outcomes but reduced the incidence of 30-day readmission.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Insuficiência Cardíaca/cirurgia , Implante de Prótese de Valva Cardíaca , Coração Auxiliar , Implantação de Prótese , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Ecocardiografia , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Implantação de Prótese/métodos , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/mortalidade
19.
J Card Surg ; 34(2): 82-91, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30710496

RESUMO

BACKGROUND: Left ventricular assist devices (LVADs) are being used more frequently for treating refractory, advanced heart failure. However, infection remains a frequent complication. In this study, we analyzed the incidence of severe infections in LVAD recipients to determine its impact on survival. METHODS: From May 2009 through March 2016, 437 patients with advanced heart failure underwent implantation of a continuous-flow LVAD (n = 314, HeartMate II LVAD [Abbott Laboratories, Abbott Park, IL]; n = 123 HeartWare HVAD [Medtronic, Minneapolis, MN]). We analyzed the rate of severe device infection requiring surgical intervention or involving sepsis and the impact of severe infection on outcomes in patients on long-term LVAD support. RESULTS: Infection occurred in 244 patients (HeartMate II, n = 186; HVAD, n = 58); severe infections developed in 160 patients (HeartMate II, n = 119; HVAD, n = 41). HeartMate II recipients had 344 severe infection events (0.63 events per patient-year [EPPY]), whereas HeartWare recipients had 89 severe infection events (0.42 EPPY; P = 0.047). HeartMate II recipients had a higher incidence of pump infections (P < 0.001). Severe infections did not significantly affect survival (P = 0.42). CONCLUSIONS: Although HeartMate II patients had a significantly higher incidence of pump infections requiring surgical treatment, survival was not adversely affected. The difference in postoperative infection rates may be an important factor in device type selection.


Assuntos
Remoção de Dispositivo/métodos , Coração Auxiliar/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Feminino , Seguimentos , Insuficiência Cardíaca/terapia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Texas/epidemiologia , Fatores de Tempo
20.
J Card Surg ; 34(11): 1204-1207, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31478230

RESUMO

BACKGROUND: Despite technological advancements, pump durability and pump-related complications continue to affect and adversely impact the lives of patients with end-stage heart failure on left ventricular assist device (LVAD) support. In an attempt to avoid recurrent LVAD-related complications, there may be circumstances where it is clinically advantageous to exchange a patient's device from HeartMate II to HeartWare HVAD. However, there is a paucity of data that describes the safety and feasibility of such an approach. OBJECTIVE: We present the largest single-center series of HeartMate II (HMII) to HeartWare (HVAD) device exchanges. METHODS: A retrospective review of 11 patients who underwent HMII to HVAD exchange from 2012 to 2017 was conducted to evaluate patient characteristics, incidence of postoperative complications, and survival. RESULTS: Eleven male patients (mean age 55 ± 14.4 years) underwent HMII to HVAD device exchange. One patient expired on postoperative day 7 secondary to sepsis. One patient was lost-to-follow-up after 23 months. An additional three patients died at 5, 7, and 24 months. Mean follow-up after device exchange was 1555 ± 311 days for the remaining six patients. None of the 11 study patients underwent LVAD explant, further device exchange, or heart transplant. CONCLUSION: Exchange of an HMII LVAD to an HVAD can be performed safely with acceptable perioperative morbidity and mortality.


Assuntos
Coração Auxiliar , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA