Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 429
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 612(7939): 228-231, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36477127

RESUMO

Gamma-ray bursts (GRBs) are flashes of high-energy radiation arising from energetic cosmic explosions. Bursts of long (greater than two seconds) duration are produced by the core-collapse of massive stars1, and those of short (less than two seconds) duration by the merger of compact objects, such as two neutron stars2. A third class of events with hybrid high-energy properties was identified3, but never conclusively linked to a stellar progenitor. The lack of bright supernovae rules out typical core-collapse explosions4-6, but their distance scales prevent sensitive searches for direct signatures of a progenitor system. Only tentative evidence for a kilonova has been presented7,8. Here we report observations of the exceptionally bright GRB 211211A, which classify it as a hybrid event and constrain its distance scale to only 346 megaparsecs. Our measurements indicate that its lower-energy (from ultraviolet to near-infrared) counterpart is powered by a luminous (approximately 1042 erg per second) kilonova possibly formed in the ejecta of a compact object merger.


Assuntos
Astros Celestes
2.
Clin Radiol ; 79(6): e791-e798, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38403540

RESUMO

AIM: To evaluate arterial enhancement, its depiction, and image quality in low-tube potential whole-body computed tomography (CT) angiography (CTA) with extremely low iodine dose and compare the results with those obtained by hybrid-iterative reconstruction (IR) and deep-learning image-reconstruction (DLIR) methods. MATERIALS AND METHODS: This prospective study included 34 consecutive participants (27 men; mean age, 74.2 years) who underwent whole-body CTA at 80 kVp for evaluating aortic diseases between January and July 2020. Contrast material (240 mg iodine/ml) with simultaneous administration of its quarter volume of saline, which corresponded to 192 mg iodine/ml, was administered. CT raw data were reconstructed using adaptive statistical IR-Veo of 40% (hybrid-IR), DLIR with medium- (DLIR-M), and high-strength level (DLIR-H). A radiologist measured CT attenuation of the arteries and background noise, and the signal-to-noise ratio (SNR) was then calculated. Two reviewers qualitatively evaluated the arterial depictions and diagnostic acceptability on axial, multiplanar-reformatted (MPR), and volume-rendered (VR) images. RESULTS: Mean contrast material volume and iodine weight administered were 64.1 ml and 15.4 g, respectively. The SNRs of the arteries were significantly higher in the following order of the DLIR-H, DLIR-M, and hybrid-IR (p<0.001). Depictions of six arteries on axial, three arteries on MPR, and four arteries on VR images were significantly superior in the DLIR-M or hybrid-IR than in the DLIR-H (p≤0.009 for each). Diagnostic acceptability was significantly better in the DLIR-M and DLIR-H than in the hybrid-IR (p<0.001-0.005). CONCLUSION: DLIR-M showed well-balanced arterial depictions and image quality compared with the hybrid-IR and DLIR-H.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste , Aprendizado Profundo , Doses de Radiação , Imagem Corporal Total , Humanos , Masculino , Feminino , Idoso , Estudos Prospectivos , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Imagem Corporal Total/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Doenças da Aorta/diagnóstico por imagem
3.
Clin Radiol ; 79(4): e554-e559, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38453389

RESUMO

AIM: To compare the radiation dose, image quality, and conspicuity of pancreatic ductal adenocarcinoma (PDAC) in pancreatic protocol dual-energy computed tomography (CT) between two X-ray tubes mounted in the same CT machine. MATERIAL AND METHODS: This retrospective study comprised 80 patients (median age, 73 years; 45 men) who underwent pancreatic protocol dual-energy CT from January 2019 to March 2022 using either old (Group A, n=41) or new (Group B, n=39) X-ray tubes mounted in the same CT machine. The imaging parameters were completely matched between the two groups, and CT data were reconstructed at 70 and 40 keV. The CT dose-index volume (CTDIvol); CT attenuation of the abdominal aorta, pancreas, and PDAC; background noise; and qualitative scores for the image noise, overall image quality, and PDAC conspicuity were compared between the two groups. RESULTS: The CTDIvol was lower in Group B than Group A (7.9 versus 9.2 mGy; p<0.001). The CT attenuation of all anatomical structures at 70 and 40 keV was comparable between the two groups (p=0.06-0.78). The background noise was lower in Group B than Group A (12 versus 14 HU at 70 keV, p=0.046; and 26 versus 30 HU at 40 keV, p<0.001). Qualitative scores for image noise and overall image quality at 70 and 40 keV and PDAC conspicuity at 40 keV were higher in Group B than Group A (p<0.001-0.045). CONCLUSION: The latest X-ray tube could reduce the radiation dose and improve image quality in pancreatic protocol dual-energy CT.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Masculino , Humanos , Idoso , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos , Raios X , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Carcinoma Ductal Pancreático/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos
4.
Clin Radiol ; 77(2): e138-e146, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34782114

RESUMO

AIM: To evaluate the computed tomography (CT) attenuation values, background noise, arterial depiction, and image quality in whole-body dual-energy CT angiography (DECTA) at 40 keV with a reduced iodine dose using deep-learning image reconstruction (DLIR) and compare them with hybrid iterative reconstruction (IR). MATERIAL AND METHODS: Whole-body DECTA with a reduced iodine dose (200 mg iodine/kg) was performed in 22 patients, and DECTA data at 1.25-mm section thickness with 50% overlap were reconstructed at 40 keV using 40% adaptive statistical iterative reconstruction with Veo (hybrid-IR group), and DLIR at medium and high levels (DLIR-M and DLIR-H groups). The CT attenuation values of the thoracic and abdominal aortas and iliac artery and background noise were measured. Arterial depiction and image quality on axial, multiplanar reformatted (MPR), and volume-rendered (VR) images were assessed by two readers. Quantitative and qualitative parameters were compared between the hybrid-IR, DLIR-M, and DLIR-H groups. RESULTS: The vascular CT attenuation values were almost comparable between the three groups (p=0.013-0.97), but the background noise was significantly lower in the DLIR-H group than in the hybrid-IR and DLIR-M groups (p<0.001). The arterial depictions on axial and MPR images and in almost all arteries on VR images were comparable (p=0.14-1). The image quality of axial, MPR, and VR images was significantly better in the DLIR-H group (p<0.001-0.015). CONCLUSION: DLIR significantly reduced background noise and improved image quality in DECTA at 40 keV compared with hybrid-IR, while maintaining the arterial depiction in almost all arteries.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Aprendizado Profundo , Iodo , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Imagem Corporal Total/métodos
5.
Clin Radiol ; 76(9): 710.e15-710.e24, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33879322

RESUMO

AIM: To evaluate the use of deep-learning-based image reconstruction (DLIR) algorithms in dynamic contrast-enhanced computed tomography (CT) of the abdomen, and to compare the image quality and lesion conspicuity among the reconstruction strength levels. MATERIALS AND METHODS: This prospective study included 59 patients with 373 hepatic lesions who underwent dynamic contrast-enhanced CT of the abdomen. All images were reconstructed using four reconstruction algorithms, including 40% adaptive statistical iterative reconstruction-Veo (ASiR-V) and DLIR at low, medium, and high-strength levels (DLIR-L, DLIR-M, and DLIR-H, respectively). The signal-to-noise ratio (SNR) of the abdominal aorta, portal vein, liver, pancreas, and spleen and the lesion-to-liver contrast-to-noise ratio (CNR) were calculated and compared among the four reconstruction algorithms. The diagnostic acceptability was qualitatively assessed and compared among the four reconstruction algorithms and the conspicuity of hepatic lesions was compared between <5 and ≥5 mm lesions. RESULTS: The SNR of each anatomical structure (p<0.0001) and CNR (p<0.0001) were significantly higher in DLIR-H than the other reconstruction algorithms. Diagnostic acceptability was significantly better in DLIR-M than the other reconstruction algorithms (p<0.0001). The conspicuity of hepatic lesions was highest when using 40% ASiR-V and tended to lessen as the reconstruction strength level was getting higher in DLIR, especially in <5 mm lesions; however, all hepatic lesions could be detected. CONCLUSIONS: DLIR improved the SNR, CNR, and image quality compared with 40% ASiR-V, while making it possible to decrease lesion conspicuity using higher reconstruction strength.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Meios de Contraste , Aprendizado Profundo , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia Abdominal/métodos
6.
Clin Radiol ; 75(4): 320.e17-320.e23, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31879024

RESUMO

AIM: To evaluate the value of virtual monochromatic images (VMIs) at lower energy levels in fast-voltage-switching dual-energy computed tomography (DECT) for assessing pancreatic ductal adenocarcinoma (PDAC). MATERIALS AND METHODS: The institutional review board approved this prospective study. Written informed consent was obtained from all patients. Seventy-four consecutive patients with PDAC underwent dynamic contrast-enhanced DECT. Two radiologists reviewed eight energy levels (40, 45, 50, 55, 60, 65, 70, and 75 keV) of the pancreatic parenchymal phase VMIs. CT attenuation of the PDAC and pancreatic parenchyma, background noise, signal-to-noise ratio (SNR) of the pancreas, tumour-to-pancreas contrast-to-noise ratio (CNR), major and minor axes of PDAC, and qualitative tumour conspicuity were compared among the VMIs at eight energy levels. RESULTS: CT attenuation of PDAC and pancreatic parenchyma, background noise, SNR, and CNR peaked on VMIs at 40 keV with statistically significant difference (p<0.0001) and gradually decreased with increasing energy levels. The reproducibility in measuring tumour size was better on VMIs at 40 keV (28.8 and 29.2 mm of major axis in readers 1 and 2, respectively) and tended to be overestimated at higher energy levels (29.8 and 30.9 mm of major axis at 75 keV in readers 1 and 2, respectively). Qualitative tumour conspicuity was also significantly superior on VMIs at 40 keV than at all other energy levels (p<0.0001). CONCLUSION: VMIs at 40 keV demonstrated significantly increased SNR of the pancreas, CNR, and tumour conspicuity and high reproducibility in measuring tumour size for assessing PDAC.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Carcinoma Ductal Pancreático/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
7.
Clin Radiol ; 74(6): 490.e1-490.e6, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30914207

RESUMO

AIM: To evaluate the potential value of magnetic resonance imaging (MRI) for predicting postoperative pancreatic fistula (POPF) in patients with pancreatic cancer (PC) and non-pancreatic cancer (non-PC). MATERIAL AND METHODS: This retrospective study was approved by the institutional review board and written informed consent was waived. Forty patients underwent pancreatoduodenectomy due to PC (n=31) and non-PC (n=9). The pancreas-to-muscle signal intensity ratio (SIR) on three-dimensional (3D)- fast field echo (FFE) T1-, in- and opposed-phase T1-, and T2-weighted images, as well as the apparent diffusion coefficient (ADC) value of the pancreas were measured. The frequency of POPF and MRI measurements were compared between patients with PC and non-PC. The MRI measurements were also compared with the grade of pancreatic fibrosis on pathological findings, fat deposition, and interstitial oedema. RESULTS: The frequency of POPF was significantly higher in patients with non-PC than in those with PC (p=0.0067), with an odds ratio of 10.4. The SIR on 3D-FFE T1-weighted images was significantly higher in patients with non-PC (p=0.0001) and those with POPF (p=0.017) than in those with PC and those without POPF, respectively. Multiple regression analysis demonstrated that the SIR on 3D-FFE T1-weighted image was independently associated with the grade of pancreatic fibrosis (p<0.0001). CONCLUSION: The frequency of POPF was significantly higher in patients with non-PC than in those with PC was inversely related to the grade of pancreatic fibrosis. The SIR on 3D-FFE T1-weighted image might be a potential imaging biomarker for predicting POPF.


Assuntos
Imageamento por Ressonância Magnética/métodos , Pancreatopatias/diagnóstico por imagem , Pancreatopatias/patologia , Fístula Pancreática/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Fibrose , Humanos , Masculino , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Pâncreas/cirurgia , Pancreatopatias/cirurgia , Fístula Pancreática/patologia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Complicações Pós-Operatórias/patologia
8.
Clin Radiol ; 73(6): 594.e1-594.e6, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29459139

RESUMO

AIM: To compare right adrenal vein (RAV) visualisation and contrast enhancement degree on adrenal venous phase images reconstructed using adaptive statistical iterative reconstruction (ASiR) and model-based iterative reconstruction (MBIR) techniques. MATERIAL AND METHODS: This prospective study was approved by the institutional review board, and written informed consent was waived. Fifty-seven consecutive patients who underwent adrenal venous phase imaging were enrolled. The same raw data were reconstructed using ASiR 40% and MBIR. The expert and beginner independently reviewed computed tomography (CT) images. RAV visualisation rates, background noise, and CT attenuation of the RAV, right adrenal gland, inferior vena cava (IVC), hepatic vein, and bilateral renal veins were compared between the two reconstruction techniques. RESULTS: RAV visualisation rates were higher with MBIR than with ASiR (95% versus 88%, p=0.13 in expert and 93% versus 75%, p=0.002 in beginner, respectively). RAV visualisation confidence ratings with MBIR were significantly greater than with ASiR (p<0.0001, both in the beginner and the expert). The mean background noise was significantly lower with MBIR than with ASiR (p<0.0001). Mean CT attenuation values of the RAV, right adrenal gland, IVC, and hepatic vein were comparable between the two techniques (p=0.12-0.91). Mean CT attenuation values of the bilateral renal veins were significantly higher with MBIR than with ASiR (p=0.0013 and 0.02). CONCLUSION: Reconstruction of adrenal venous phase images using MBIR significantly reduces background noise, leading to an improvement in the RAV visualisation compared with ASiR.


Assuntos
Glândulas Suprarrenais/irrigação sanguínea , Veias/diagnóstico por imagem , Glândulas Suprarrenais/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/métodos , Veias Hepáticas/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Modelos Teóricos , Tomografia Computadorizada Multidetectores/métodos , Estudos Prospectivos , Veias Renais/diagnóstico por imagem , Veia Cava Inferior/diagnóstico por imagem , Adulto Jovem
9.
Nature ; 476(7361): 421-4, 2011 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-21866154

RESUMO

Supermassive black holes have powerful gravitational fields with strong gradients that can destroy stars that get too close, producing a bright flare in ultraviolet and X-ray spectral regions from stellar debris that forms an accretion disk around the black hole. The aftermath of this process may have been seen several times over the past two decades in the form of sparsely sampled, slowly fading emission from distant galaxies, but the onset of the stellar disruption event has not hitherto been observed. Here we report observations of a bright X-ray flare from the extragalactic transient Swift J164449.3+573451. This source increased in brightness in the X-ray band by a factor of at least 10,000 since 1990 and by a factor of at least 100 since early 2010. We conclude that we have captured the onset of relativistic jet activity from a supermassive black hole. A companion paper comes to similar conclusions on the basis of radio observations. This event is probably due to the tidal disruption of a star falling into a supermassive black hole, but the detailed behaviour differs from current theoretical models of such events.

10.
Clin Radiol ; 72(10): 901.e13-901.e19, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28673448

RESUMO

AIM: To compare contrast enhancement and image quality between renovascular computed tomography (CT) images with adaptive statistical iterative reconstruction (ASiR) and that with model-based iterative reconstruction (MBIR). MATERIAL AND METHODS: This retrospective study was approved by the institutional review board and written informed consent was waived. Twenty-five consecutive patients who underwent renovascular CT were enrolled in this study. The same raw projection data were reconstructed using ASiR 40%, 100%, and MBIR. Background noise, CT attenuation, and signal-to-noise ratio (SNR) of the renal vessels and kidneys, and image quality were compared among the three reconstruction techniques. RESULTS: Mean background noise was significantly lower with MBIR at the first and second phases than those with ASiR 40% and 100% (p<0.0001). Mean CT attenuation of the abdominal aorta, renal artery, and renal cortex obtained at the first phase and those of the renal vein and renal medulla at the second phase were comparable among the three techniques (p=0.051-1.00). Mean SNRs of the abdominal aorta, renal artery, renal cortex, renal vein, and renal medulla were significantly higher with MBIR than with ASiR 40% or 100% (both p<0.0001). The depiction of the renal artery and vein as well as image quality significantly improved with MBIR compared with those with ASiR 40% and 100% (p<0.0001-0.0016). CONCLUSION: Reconstruction of renovascular CT images with MBIR significantly reduces background noise, leading to an improvement in SNR and image quality compared with that using ASiR.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Rim/irrigação sanguínea , Rim/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Feminino , Humanos , Medula Renal/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Artéria Renal/diagnóstico por imagem , Veias Renais/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Razão Sinal-Ruído
11.
J Obstet Gynaecol Res ; 40(2): 614-7, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24148073

RESUMO

Paraneoplastic cerebellar degeneration is a paraneoplastic neurological syndrome caused by the remote effect of certain systemic cancers and is characterized by subacute cerebellar symptoms. A 62-year-old woman suffering from unidentified cerebellar symptoms was admitted to our hospital. Paraneoplastic cerebellar degeneration was suspected and ovarian cancer was detected after the systemic examination for malignancy. The symptoms of vertigo and dysarthria were improved a little after surgical operation and treatments of γ-globulin, steroid pulse and tacrolimus hydrate. The cerebellar symptoms of paraneoplastic cerebellar degeneration are often evident prior to detection of malignancy. It is important to perform systemic examination for malignancy in case of unidentified cerebellar symptoms.


Assuntos
Adenocarcinoma de Células Claras/complicações , Neoplasias Ovarianas/complicações , Degeneração Paraneoplásica Cerebelar/etiologia , Adenocarcinoma de Células Claras/diagnóstico , Anticorpos/sangue , Feminino , Humanos , Pessoa de Meia-Idade , Proteínas do Tecido Nervoso/imunologia , Neoplasias Ovarianas/diagnóstico , Degeneração Paraneoplásica Cerebelar/sangue
12.
J Oral Rehabil ; 41(8): 581-7, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24702545

RESUMO

The influence of masticatory loading stimulus on mandibular development is not fully clear. In this paper, experimental alterations in the daily muscle use, caused by a changed diet consistency, were continuously monitored, while adaptations in bone and cartilage were examined. It is hypothesised that decreased muscular loading will result in a decrease in the growth factor expression and mandible growth. Fourteen 21-day-old Wistar strain male rats were randomly divided into two groups and fed on either a hard or soft diet for 14 weeks. An implanted radio-telemetric device recorded continuously muscle activity of the superficial masseter muscle. Chondroblast proliferation in the condylar cartilage was identified by insulin-like growth factor-1 receptor (IGF-1r) immunostaining. Furthermore, an X-ray was taken for cephalometric analysis. In the soft-diet group, the duty time of the superficial masseter muscle at higher activity levels was significantly lower than that in the hard-diet group. This decrease in muscular loading of the jaw system was accompanied by: a significant reduction in (i) articular cartilage thickness, (ii) expression of IGF-1r immunopositive cells and (iii) mandible ramus height. In conclusion, a decrease in masticatory demand during the growth period leads to insufficient mandibular development.


Assuntos
Alimentos , Mandíbula/crescimento & desenvolvimento , Côndilo Mandibular/metabolismo , Músculo Masseter/fisiologia , Mastigação/fisiologia , Adaptação Fisiológica , Animais , Biomarcadores/metabolismo , Eletromiografia , Imuno-Histoquímica , Masculino , Contração Muscular/fisiologia , Fibras Musculares Esqueléticas/fisiologia , Distribuição Aleatória , Ratos , Ratos Wistar , Receptor IGF Tipo 1/metabolismo
13.
Clin Radiol ; 68(6): 595-9, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23384503

RESUMO

AIM: To evaluate magnetic resonance imaging (MRI) findings of granulomatous prostatitis (GP) developing after intravesical Bacillus Calmette-Guérin (BCG) therapy. MATERIALS AND METHODS: Ten patients with pathologically proven GP underwent prostatic MRI. Lesion shape and signal intensity (SI) were evaluated on T2-weighted (T2WI), T1WI, and diffusion-weighted imaging (DWI). RESULTS: Polygonal nodular lesions with notches, diffuse lesions, and cystic lesions with mural nodules were seen in two, six, and one patients, respectively. The remaining patient had a diffuse and cystic lesion. All diffuse lesions showed higher SI than muscle on T1WI and higher SI than the normal peripheral zone (PZ) on DWI. On T2WI, six of seven diffuse lesions showed a slightly lower SI than bone marrow and the remaining one lesion was iso-intense. All nodular lesions showed a low SI similar to muscle on T2WI and were iso-intense to muscle on T1WI. On DWI, two each of the four nodular lesions showed slightly lower SI and slightly higher SI than the normal PZ, respectively. All contents within the cyst and mural nodules showed markedly high and low SI on T2WI, respectively. On DWI, all fluids within cysts showed markedly high SI. One each of the mural nodules showed slightly higher SI and slightly lower SI than the normal PZ on DWI. CONCLUSION: Three main MRI patterns of GP were identified: diffuse, nodular, and cystic with mural nodule; among them, the diffuse type was the most common. Cystic lesions with mural nodules could accompany the lesion.


Assuntos
Vacina BCG/efeitos adversos , Granuloma/induzido quimicamente , Prostatite/induzido quimicamente , Neoplasias da Bexiga Urinária/tratamento farmacológico , Administração Intravesical , Idoso , Idoso de 80 Anos ou mais , Vacina BCG/administração & dosagem , Vacina BCG/uso terapêutico , Imagem de Difusão por Ressonância Magnética , Granuloma/patologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Próstata/patologia , Prostatite/patologia , Estudos Retrospectivos
14.
J Oral Rehabil ; 40(3): 205-13, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23331038

RESUMO

Parkinson's disease (PD), a major neurological disease, is characterised by a marked loss of dopaminergic neurons in the substantia nigra. Patients with PD frequently show chewing and swallowing dysfunctions, but little is known about the characteristics of their stomatognathic functions. The purpose of this study was to evaluate the influence of PD on jaw muscle fibre and functions. PD model rats were made by means of the injection of 6-hydroxydopamine (6-OHDA) into the striatum of 8-week-old Sprague-Dawley male rats. Five weeks after the injection, a radio-telemetric device was implanted to record muscle activity continuously from the superficial masseter and anterior belly of digastric muscles. Muscle activity was recorded for 3 days and was evaluated by the total duration of muscle activity per day (duty time). After recording the muscle activities, jaw muscles were isolated for immunohistochemical and PCR analyses. In PD model rats, the following findings of the digastrics muscles verify that compared to the control group: (i) the higher duty time exceeding 5% of the peak activity level, (ii) the higher expression of the mRNA of myosin heavy chain type I, and (iii) the tendency for fast to slow fibre-type transition. With respect to the masseter muscle, there were no significant differences in all analyses. In conclusion, PD leads to the changes in the jaw behaviours, resulting in a PD-specific chewing and swallowing dysfunctions.


Assuntos
Músculo Masseter/metabolismo , Fibras Musculares Esqueléticas/metabolismo , Cadeias Pesadas de Miosina/metabolismo , Doença de Parkinson/metabolismo , Animais , Estudos de Casos e Controles , Modelos Animais de Doenças , Eletromiografia/métodos , Masculino , Reação em Cadeia da Polimerase , Ratos , Ratos Sprague-Dawley
15.
Nature ; 440(7081): 184-6, 2006 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-16525466

RESUMO

The prompt gamma-ray emission from gamma-ray bursts (GRBs) should be detectable out to distances of z > 10 (ref. 1), and should therefore provide an excellent probe of the evolution of cosmic star formation, reionization of the intergalactic medium, and the metal enrichment history of the Universe. Hitherto, the highest measured redshift for a GRB has been z = 4.50 (ref. 5). Here we report the optical spectrum of the afterglow of GRB 050904 obtained 3.4 days after the burst; the spectrum shows a clear continuum at the long-wavelength end of the spectrum with a sharp cut-off at around 9,000 A due to Lyman alpha absorption at z approximately 6.3 (with a damping wing). A system of absorption lines of heavy elements at z = 6.295 +/- 0.002 was also detected, yielding the precise measurement of the redshift. The Si ii fine-structure lines suggest a dense, metal-enriched environment around the progenitor of the GRB.

16.
Nature ; 434(7037): 1112-5, 2005 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-15858569

RESUMO

It was established over a decade ago that the remarkable high-energy transients known as soft gamma-ray repeaters (SGRs) are located in our Galaxy and originate from neutron stars with intense (< or = 10(15)G) magnetic fields-so-called 'magnetars'. On 27 December 2004, a giant flare with a fluence exceeding 0.3 erg cm(-2) was detected from SGR 1806-20. Here we report the detection of a fading radio counterpart to this event. We began a monitoring programme from 0.2 to 250 GHz and obtained a high-resolution 21-cm radio spectrum that traces the intervening interstellar neutral hydrogen clouds. Analysis of the spectrum yields the first direct distance measurement of SGR 1806-20: the source is located at a distance greater than 6.4 kpc and we argue that it is nearer than 9.8 kpc. If correct, our distance estimate lowers the total energy of the explosion and relaxes the demands on theoretical models. The energetics and the rapid decay of the radio source are not compatible with the afterglow model that is usually invoked for gamma-ray bursts. Instead, we suggest that the rapidly decaying radio emission arises from the debris ejected during the explosion.

17.
Nature ; 437(7060): 855-8, 2005 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-16208364

RESUMO

Gamma-ray bursts (GRBs) fall into two classes: short-hard and long-soft bursts. The latter are now known to have X-ray and optical afterglows, to occur at cosmological distances in star-forming galaxies, and to be associated with the explosion of massive stars. In contrast, the distance scale, the energy scale and the progenitors of the short bursts have remained a mystery. Here we report the discovery of a short-hard burst whose accurate localization has led to follow-up observations that have identified the X-ray afterglow and (for the first time) the optical afterglow of a short-hard burst; this in turn led to the identification of the host galaxy of the burst as a late-type galaxy at z = 0.16 (ref. 10). These results show that at least some short-hard bursts occur at cosmological distances in the outskirts of galaxies, and are likely to be caused by the merging of compact binaries.

18.
Nature ; 437(7060): 845-50, 2005 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-16208362

RESUMO

The final chapter in the long-standing mystery of the gamma-ray bursts (GRBs) centres on the origin of the short-hard class of bursts, which are suspected on theoretical grounds to result from the coalescence of neutron-star or black-hole binary systems. Numerous searches for the afterglows of short-hard bursts have been made, galvanized by the revolution in our understanding of long-duration GRBs that followed the discovery in 1997 of their broadband (X-ray, optical and radio) afterglow emission. Here we present the discovery of the X-ray afterglow of a short-hard burst, GRB 050709, whose accurate position allows us to associate it unambiguously with a star-forming galaxy at redshift z = 0.160, and whose optical lightcurve definitively excludes a supernova association. Together with results from three other recent short-hard bursts, this suggests that short-hard bursts release much less energy than the long-duration GRBs. Models requiring young stellar populations, such as magnetars and collapsars, are ruled out, while coalescing degenerate binaries remain the most promising progenitor candidates.

19.
Science ; 155(3760): 341-2, 1967 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-6016081

RESUMO

A thin section prepared from guinea pig hippocampus produced, in chloride-free medium, a train of seizure discharges in response to a single shock applied to the section. Generation of these discharges was ascribed to the lack of inhibitory processes in an absence of chloride ion.


Assuntos
Cloretos/farmacologia , Hipocampo/fisiologia , Acetatos/farmacologia , Animais , Estimulação Elétrica , Eletrofisiologia , Cobaias , Propionatos/farmacologia
20.
Science ; 278(5338): 698-701, 1997 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-9381182

RESUMO

Animals vary in their sensitivity to ethanol, a trait at least partly determined by genetic factors. In order to identify possible responsible genes, mice lacking Fyn, a non-receptor type tyrosine kinase, were investigated. These mice were hypersensitive to the hypnotic effect of ethanol. The administration of ethanol enhanced tyrosine phosphorylation of the N-methyl-D-aspartate receptor (NMDAR) in the hippocampus of control mice but not in Fyn-deficient mice. An acute tolerance to ethanol inhibition of NMDAR-mediated excitatory postsynaptic potentials in hippocampal slices developed in control mice but not in Fyn-deficient mice. These results indicate that Fyn affects behavioral, biochemical, and physiological responses to ethanol.


Assuntos
Depressores do Sistema Nervoso Central/farmacologia , Etanol/farmacologia , Atividade Motora/efeitos dos fármacos , Proteínas Tirosina Quinases/metabolismo , Proteínas Proto-Oncogênicas/metabolismo , Receptores de N-Metil-D-Aspartato/metabolismo , Animais , Potenciais Pós-Sinápticos Excitadores/efeitos dos fármacos , Flurazepam/farmacologia , Hipocampo/metabolismo , Hipnóticos e Sedativos/farmacologia , Técnicas In Vitro , Masculino , Camundongos , Camundongos Knockout , N-Metilaspartato/farmacologia , Fosforilação , Fosfotirosina/metabolismo , Proteínas Tirosina Quinases/deficiência , Proteínas Tirosina Quinases/genética , Proteínas Proto-Oncogênicas/deficiência , Proteínas Proto-Oncogênicas/genética , Proteínas Proto-Oncogênicas c-fyn
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA