Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Interv Radiol ; 35(5): 780-789.e1, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38355040

RESUMO

PURPOSE: To validate the sensitivity and specificity of a 3-dimensional (3D) convolutional neural network (CNN) artificial intelligence (AI) software for lung lesion detection and to establish concordance between AI-generated needle paths and those used in actual biopsy procedures. MATERIALS AND METHODS: This was a retrospective study using computed tomography (CT) scans from 3 hospitals. Inclusion criteria were scans with 1-5 nodules of diameter ≥5 mm; exclusion criteria were poor-quality scans or those with nodules measuring <5mm in diameter. In the lesion detection phase, 2,147 nodules from 219 scans were used to develop and train the deep learning 3D-CNN to detect lesions. The 3D-CNN was validated with 235 scans (354 lesions) for sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) analysis. In the path planning phase, Bayesian optimization was used to propose possible needle trajectories for lesion biopsy while avoiding vital structures. Software-proposed needle trajectories were compared with actual biopsy path trajectories from intraprocedural CT scans in 150 patients, with a match defined as an angular deviation of <5° between the 2 trajectories. RESULTS: The model achieved an overall AUC of 97.4% (95% CI, 96.3%-98.2%) for lesion detection, with mean sensitivity of 93.5% and mean specificity of 93.2%. Among the software-proposed needle trajectories, 85.3% were feasible, with 82% matching actual paths and similar performance between supine and prone/oblique patient orientations (P = .311). The mean angular deviation between matching trajectories was 2.30° (SD ± 1.22); the mean path deviation was 2.94 mm (SD ± 1.60). CONCLUSIONS: Segmentation, lesion detection, and path planning for CT-guided lung biopsy using an AI-guided software showed promising results. Future integration with automated robotic systems may pave the way toward fully automated biopsy procedures.


Assuntos
Aprendizado Profundo , Biópsia Guiada por Imagem , Valor Preditivo dos Testes , Software , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Biópsia Guiada por Imagem/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Idoso , Interpretação de Imagem Radiográfica Assistida por Computador , Teorema de Bayes , Biópsia por Agulha , Pulmão/diagnóstico por imagem , Pulmão/patologia
2.
NMR Biomed ; 35(10): e4783, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35661282

RESUMO

Reoxygenation has a significant impact on the tumor response to radiotherapy. With developments in radiotherapy technology, the relevance of the reoxygenation phenomenon in treatment efficacy has been a topic of interest. Evaluating the reoxygenation in the tumor microenvironment throughout the course of radiation therapy is important in developing effective treatment strategies. In the current study, we used electron paramagnetic resonance imaging (EPRI) to directly map and quantify the partial oxygen pressure (pO2 ) in tumor tissues. Human colorectal cancer cell lines, HT29 and HCT116, were used to induce tumor growth in female athymic nude mice. Tumors were irradiated with 3, 10, or 20 Gy using an x-ray irradiator. Prior to each EPRI scan, magnetic resonance imaging (MRI) was performed to obtain T2-weighted anatomical images for reference. The differences in the mean pO2 were determined through two-tailed Student's t-test and one-way analysis of variance. The median pO2 60 min after irradiation was found to be lower in HCT116 than in HT29 (9.1 ± 1.5 vs. 14.0 ± 1.0 mmHg, p = 0.045). There was a tendency for delayed and incomplete recovery of pO2 in the HT29 tumor when a higher dose of irradiation (10 and 20 Gy) was applied. Moreover, there was a dose-dependent increase in the hypoxic areas (pO2  < 10 mmHg) 2 and 24 h after irradiation in all groups. In addition, an area that showed pO2 fluctuation between hypoxia and normoxia (pO2  > 10 mmHg) was also identified surrounding the region with stable hypoxia, and it slightly enlarged after recovery from acute hypoxia. In conclusion, we demonstrated the reoxygenation phenomenon in an in vivo xenograft model study using EPRI. These findings may lead to new knowledge regarding the reoxygenation process and possibilities of a new radiation therapy concept, namely, reoxygenation-based radiation therapy.


Assuntos
Hipóxia , Neoplasias , Animais , Hipóxia Celular , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Feminino , Humanos , Camundongos , Camundongos Nus , Oxigênio/metabolismo , Microambiente Tumoral
3.
Oncology ; 100(8): 429-438, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35760062

RESUMO

INTRODUCTION: This study had two objectives: (i) to evaluate oncological outcomes in a long-term follow-up of patients with bladder cancer after reduced-port laparoscopic radical cystectomy (RP-LRC) and (ii) to assess the effect of modified Glasgow prognostic scores (mGPS) on patient outcomes. METHODS: Consecutive patients (n = 100) who received RP-LRC between March 2012 and December 2018 at our institution and affiliated hospital were retrospectively reviewed. Preoperative serum albumin and C-reactive protein levels were determined. Patients were grouped based on clinical T stage (≤cT2: n = 75, ≥cT3: n = 25) using pooled cumulative data. Oncological outcomes and mGPS as a prognostic biomarker were analyzed retrospectively. Kaplan-Meier curves displayed recurrence and survival rates. Univariate and multivariate Cox regression analyses evaluated potential prognostic factors for recurrence-free survival (RFS) and cancer-specific survival (CSS). RESULTS: Patient characteristics between the two groups were statistically similar for preoperative hematological and mGPS status, blood loss level, rate of allogeneic transfusion, and pneumoperitoneum time. After a median follow-up period of 55 months, 40/100 patients experienced disease relapse. RFS and CSS for ≤cT2 were significantly less than for ≥cT3 (p < 0.001, p < 0.05, respectively). Distant metastasis occurred in 30 patients with similar distributions of relapse sites between T-stage cohorts. Median RFS for mGPS 1/2 were 18.9 (95% confidence interval [CI]: 8.8-not assessed [NA]) and 35.0 (95% CI: 8.7-NA) months, respectively, significantly worse than for mGPS 0 (median NA, 95% CI: NA-NA); CSS was similar. Univariate and multivariate analyses revealed ≥cT3 stage, worse clinical N stage, and poor mGPS status were significant prognostic factors for short RFS and CSS. CONCLUSIONS: A large proportion of bladder cancer patients who undergo RP-LRC experience relapse, with ≥cT3 stage, worse clinical N stage or poor mGPS status identified as significant prognostic factors. Our findings may contribute to improved surgical procedures for such patients.


Assuntos
Laparoscopia , Neoplasias da Bexiga Urinária , Cistectomia/efeitos adversos , Seguimentos , Humanos , Laparoscopia/métodos , Recidiva Local de Neoplasia/cirurgia , Prognóstico , Estudos Retrospectivos , Resultado do Tratamento , Neoplasias da Bexiga Urinária/patologia
4.
BMC Cancer ; 22(1): 1259, 2022 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-36471274

RESUMO

BACKGROUND: Radiobiological daily changes within tumors are considered to be quite different between stereotactic radiotherapy (SRT) (e.g., 50 Gy in 4 fractions) and conventional radiotherapy (e.g., 60 Gy in 30 fractions). We aim to assess the optimal interval of irradiation in SRT and compare outcomes of daily irradiation with irradiation at two- to three-day intervals in SRT for patients with one to five brain metastases (BM). METHODS: This study is conducted as a multicenter open-label randomized phase II trial. Patients aged 20 or older with one to five BM, less than 3.0 cm diameter, and Karnofsky Performance Status ≥70 are eligible. A total of 70 eligible patients will be enrolled. After stratifying by the number of BMs (1, 2 vs. 3-5) and diameter of the largest tumor (< 2 cm vs. ≥ 2 cm), we randomly assigned patients (1:1) to receive daily irradiation (Arm 1), or irradiation at two- to three-day intervals (Arm 2). Both arms are performed with total dose of 27-30 Gy in 3 fractions. The primary endpoint is an intracranial local control rate, defined as intracranial local control at initially treated sites. We use a randomized phase II screening design with a two-sided α of 0∙20. The phase II trial is positive with p < 0.20. All analyses are intention to treat. This study is registered with the UMIN-clinical trials registry, number UMIN000048728. DISCUSSION: This study will provide an assessment of the impact of SRT interval on local control, survival, and toxicity for patients with 1-5 BM. The trial is ongoing and is recruiting now. TRIAL REGISTRATION: UMIN000048728. Date of registration: August 23, 2022. https://center6.umin.ac.jp/cgi-bin/ctr/ctr_view_reg.cgi?recptno=R000055515 .


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Humanos , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Neoplasias Encefálicas/secundário , Avaliação de Estado de Karnofsky , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto , Ensaios Clínicos Fase II como Assunto
5.
J Vasc Interv Radiol ; 33(3): 304-307, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35221047

RESUMO

The utility of occluding the bleeding artery using an occlusion balloon catheter during stent-graft placement for visceral artery bleeding was evaluated. Stent-graft placement for visceral artery bleeding was performed using a balloon catheter in 6 patients. All bleeding occurred after biliary or pancreatic surgery. Since 1 patient underwent the procedure twice, 7 procedures were assessed in total. Technical success, procedure-related adverse events, and 30-day mortality rates were evaluated. Technical success was defined as the placement of the stent-graft at the target site and the resolution of extravasation or pseudoaneurysm. In all procedures, stent-graft placement was successfully performed (technical success rate, 100%). Focal liver infarction occurred in 2 of 7 patients (29%), but did not require further treatment and was considered a minor adverse event. The 30-day mortality rate was 0%. In conclusion, the use of an occlusion balloon in the feeding artery facilitated successful stent-graft repair of hemorrhage from visceral arteries.


Assuntos
Implante de Prótese Vascular , Stents , Artérias , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Catéteres , Hemorragia/diagnóstico por imagem , Hemorragia/etiologia , Hemorragia/terapia , Humanos , Estudos Retrospectivos , Resultado do Tratamento
6.
J Vasc Interv Radiol ; 33(11): 1329-1334, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36511304

RESUMO

This study evaluated the utility of carbon dioxide (CO2) in angiography for the detection of lower gastrointestinal arterial bleeding initially occult to angiography with iodinated contrast media. Fourteen patients underwent CO2-enhanced angiography. In all patients, extravasation was identified by contrast-enhanced computed tomography but not by initial iodinated contrast-enhanced angiography. After iodinated contrast-enhanced angiography, CO2-enhanced angiography was performed from the same catheter position. The detection capability for extravasation on CO2-enhanced angiography was evaluated. CO2-enhanced angiography allowed for the visualization of extravasation and subsequent transcatheter arterial embolization in 11 of 14 (79%) cases, with extravasation seen during either CO2-enhanced angiography (n = 8) or subsequent repeat iodinated contrast-enhanced angiography immediately after negative CO2-enhanced angiography (n = 3). Conservative treatment was performed in the remaining 3 cases. In conclusion, CO2-enhanced angiography appears useful for identifying occult lower gastrointestinal bleeding.


Assuntos
Angiografia , Dióxido de Carbono , Humanos , Dióxido de Carbono/efeitos adversos , Angiografia/efeitos adversos , Angiografia/métodos , Meios de Contraste/efeitos adversos , Artérias , Hemorragia Gastrointestinal/induzido quimicamente , Hemorragia Gastrointestinal/diagnóstico por imagem
7.
NMR Biomed ; 34(7): e4514, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33939204

RESUMO

Dynamic nuclear polarization (DNP) of 13 C-labeled substrates enables the use of magnetic resonance imaging (MRI) to monitor specific enzymatic reactions in tumors and offers an opportunity to investigate these differences. In this study, DNP-MRI chemical shift imaging with hyperpolarized [1-13 C] pyruvate was conducted to evaluate the metabolic change in glycolytic profiles after radiation of two glioma stem-like cell-derived gliomas (GBMJ1 and NSC11) and an adherent human glioblastoma cell line (U251) in an orthotopic xenograft mouse model. The DNP-MRI showed an increase in Lac/Pyr at 6 and 16 h after irradiation (18% ± 4% and 14% ± 3%, respectively; mean ± SEM) compared with unirradiated controls in GBMJ1 tumors, whereas no significant change was observed in U251 and NSC11 tumors. Metabolomic analysis likewise showed a significant increase in lactate in GBMJ1 tumors at 16 h. An immunoblot assay showed upregulation of lactate dehydrogenase-A expression in GBMJ1 following radiation exposure, consistent with DNP-MRI and metabolomic analysis. In conclusion, our preclinical study demonstrates that the DNP-MRI technique has the potential to be a powerful diagnostic method with which to evaluate GBM tumor metabolism before and after radiation in the clinical setting.


Assuntos
Espectroscopia de Ressonância Magnética Nuclear de Carbono-13 , Glioblastoma/metabolismo , Glioblastoma/radioterapia , Animais , Linhagem Celular Tumoral , Glioblastoma/diagnóstico por imagem , Humanos , Lactato Desidrogenase 5/metabolismo , Ácido Láctico/metabolismo , Imageamento por Ressonância Magnética , Metabolômica , Camundongos Nus , Ácido Pirúvico/metabolismo
8.
Pol J Radiol ; 83: e137-e142, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30038691

RESUMO

PURPOSE: The purpose of this study is to assess the feasibility and usefulness of time-resolved magnetic resonance angiography (TR-MRA) for follow-up of visceral artery aneurysms (VAAs) after embolotherapy. MATERIAL AND METHODS: Twenty-one VAAs (11 splenic, six renal, three internal iliac, and one superior pancreaticoduodenal artery aneurysms) in 18 patients (median age, 64 years; range, 36-88 years) previously treated by embolisation with platinum coils, were evaluated. The mean size of the aneurysm was 10.5 cm3 (range, 0.3-132 cm3). Among them, 19 lesions were treated by aneurysmal packing with or without distal-to-proximal embolisation. For the remaining two lesions, distal-to-proximal embolization alone was performed. The mean observation period after embolotherapy was 35 weeks (range, 4-216). All patients underwent TR-MRA following an intravenous bolus injection of gadolinium chelate. Recanalisation was diagnosed when any portion of the aneurysmal sac was enhanced in the arterial phase. RESULTS: On TR-MRA, two lesions were diagnosed as recanalised. They were confirmed by transcatheter arteriography and re-treated by embolotherapy. For the remaining 19 lesions, there were no findings of recanalisation on TR-MRA. CONCLUSIONS: TR-MRA appears to be a feasible method for follow-up examination of VAAs treated by embolotherapy.

10.
Pol J Radiol ; 81: 593-597, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27994698

RESUMO

BACKGROUND: The effects of the reduction of low-energy X-ray spectrum on lung perfusion images created by dual-energy CT have not been well evaluated. The aim of this study is to investigate the reliability of lung perfusion blood volume (PBV) images created by dual-energy CT (DECT) equipped with or without a tin filter, focusing on its accuracy adjacent to high-attenuation areas. MATERIAL/METHODS: Among 176 patients who underwent DECT for suspicion of pulmonary embolism, 38 patients (mean age, 64; range, 16 to 83 years) without apparent evidence of pulmonary embolism were evaluated in this study. They underwent DECT at 100/140 kVp with a tin filter on 140 kVp tube (Group A; n=18) or at 80/140 kVp without the filter (Group B; n=20). On the lung PBV images, the degrees of artifacts - pulmonary enhancement defect (PED) and pseudo-enhancement in the trachea (PTE) adjacent to the vena cava were evaluated using a four-point scale (0=minimal to 3=prominent). RESULTS: The mean degrees of artifact in Group A were significantly lower than those in Group B (0.8 vs. 1.9; P<0.0001 for PED, respectively, and 1.1 vs. 2.2; P<0.0001 for TPE, respectively). The mean CTDIvols were 4.90±1.14 and 12.98±3.15 mGy (P<0.0001) for Group A and Group B, respectively. CONCLUSIONS: The quality and accuracy of dual-energy lung perfusion image will be improved by using the tin filter technique.

11.
Pol J Radiol ; 81: 382-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27617047

RESUMO

BACKGROUND: Spinal artery ischemia is a rare but serious complication of embolization for treatment of hemoptysis. When the spinal artery is visualized at angiography, embolization should not be performed. However, it has been reported that spinal artery feeders are not visible on angiography in patients with developing spinal infarction. CASE REPORT: A 70-year-old man with a history of pulmonary aspergillosis had hemoptysis and underwent contrast-enhanced CT, revealing a pulmonary artery pseudoaneurysm (PAP) in the left upper lobe. Systemic angiography from the fifth left intercostal artery showed the PAP at the distal site, but the access route to the PAP was very tortuous and long. Although the spinal branch could not be observed with that angiography, CT during angiography was performed, and it visualized the posterior spinal artery obviously. Thus, the artery distal and proximal to the PAP was then successfully coil-embolized from the pulmonary artery. CONCLUSIONS: CT during angiography may be useful to confirm the presence of the spinal artery for treatment of hemoptysis by embolization.

12.
J Vasc Interv Radiol ; 26(6): 856-864.e1, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25851199

RESUMO

PURPOSE: To assess reperfusion rates after coil embolization for pulmonary arteriovenous malformations (PAVMs) using time-resolved magnetic resonance (MR) angiography or pulmonary angiography. MATERIALS AND METHODS: Patients with PAVMs who underwent embolization and met the following inclusion criteria were included: (a) embolization was performed using bare or fibered platinum microcoils or both, (b) the complete cessation of flow was confirmed by digital subtraction angiography, and (c) follow-up examinations were conducted with time-resolved MR angiography or pulmonary angiography. Coil embolization was performed in 16 patients with 24 untreated or reperfused PAVMs. Sac embolization was performed for 12 untreated PAVMs. Feeding artery embolization was performed as primary embolization in each of the 12 reperfused PAVMs. Five PAVMs were treated 2 to 4 times because of reperfusion. The study included 32 coil embolizations. Follow-up images were reviewed, and reperfusion rates were assessed. The relationships between reperfusion and the location of PAVM, size of PAVM (feeding artery and venous sac), coils (number and total length), timing of embolization (primary or repeat embolization), and types of coils used (with or without fibered coils) were examined. RESULTS: Reperfusion rates at 3, 6, 12, and 24 months were 8%, 27%, 36%, and 49%, respectively, for the 12 untreated PAVMs (primary embolization) and 50%, 50%, 92%, and 100%, respectively, for the 12 reperfused PAVMs (repeat embolization) (P = .0062). No significant differences were observed in the other parameters measured. CONCLUSIONS: When evaluated with time-resolved MR angiography or pulmonary angiography, reperfusion rates after coil embolization for PAVM were considerably high, particularly with repeat embolization.


Assuntos
Malformações Arteriovenosas/terapia , Embolização Terapêutica/instrumentação , Angiografia por Ressonância Magnética , Imagem de Perfusão/métodos , Flebografia/métodos , Artéria Pulmonar/anormalidades , Circulação Pulmonar , Veias Pulmonares/anormalidades , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Malformações Arteriovenosas/diagnóstico , Malformações Arteriovenosas/fisiopatologia , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
13.
Abdom Imaging ; 40(8): 3091-8, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26099474

RESUMO

PURPOSE: We examined whether the shortened breath-hold 3-dimensional volumetric interpolated breath-hold examination (3D-VIBE) sequence for high acceleration factor (AF) using the controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) could substitute for the conventional sequence using generalized autocalibrating partially parallel acquisition (GRAPPA) in patients undergoing routine gadoxetic acid-enhanced liver MRI. MATERIALS AND METHODS: Thirty patients with clinically suspected focal liver lesions were scanned using 3D-VIBE sequences with GRAPPA with AF = 2 and AF = 4 and CAIPIRINHA with AF = 4 (acquisition times: 21, 14, and 12 s, respectively) during the hepatobiliary phase. Visual evaluations using a 3- or 5-point scale and signal-to-noise ratio (SNR) analysis were performed for the 3 sequences. RESULTS: For CAIPIRINHA with AF = 4, there was significantly less image noise in both visual evaluation and SNR analysis and fewer parallel imaging artifacts than for GRAPPA with AF = 4 (P < 0.0005); it was equal to GRAPPA with AF = 2 and had fewer motion artifacts than GRAPPA with AF = 2 and 4 (P < 0.0012). The liver edge sharpness and hepatic vessel clarity, lesion conspicuity, and overall image quality were rated significantly higher with CAIPIRINHA with AF = 4 than GRAPPA with AF = 2 and AF = 4 (P < 0.009). For GRAPPA with AF = 4, lesion conspicuity and overall image quality were rated significantly lower than for GRAPPA with AF = 2 (P < 0.012). CONCLUSION: The shortened breath-hold 3D-VIBE sequence using the new CAIPIRINHA technique with a high AF of 4 was superior to the conventional GRAPPA sequence. The shortened breath-hold sequence using GRAPPA with a high AF of 4 worsened the image quality and lesion conspicuity.


Assuntos
Suspensão da Respiração , Meios de Contraste , Aumento da Imagem , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/patologia , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artefatos , Feminino , Gadolínio DTPA , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo , Adulto Jovem
14.
Abdom Imaging ; 40(1): 112-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24965897

RESUMO

PURPOSE: To investigate the usefulness of MRI for detection of sarcomatoid renal cell carcinoma (SRCC) components within RCC and differentiation from other renal tumors. METHODS: Two observers independently interpreted T2-weighted images of 10 patients with pathologically confirmed RCCs with SRCC and 131 with non-SRCC renal tumors, with special reference to conspicuously low signal intensity (SI) areas (T2LIA) compared to the renal cortex. SRCC probability was classified as (1) definitely non-SRCC, no T2LIA; (2) probably non-SRCC, <1 cm T2LIA; (3) low probability of SRCC, homogeneous tumor with 1-3 cm T2LIA; (4) probably SRCC, heterogeneous tumor with 1-3 cm T2LIA; and (5) definitely SRCC, >3 cm T2LIA, multiple >1 cm T2LIAs, or showing disruption of the pseudocapsule. The observers used chemical shift imaging to exclude the area representing hemorrhage or hemosiderin deposition from T2LIA. Scores of 4/5 were regarded as positive for evaluating the accuracy and area under the receiver operating characteristic curve. The SI ratio of the lowest SI in the tumor to that of the renal cortex in the 1 and ≥2 score groups was compared using Mann-Whitney's U test. RESULTS: Sensitivity, specificity, accuracy, and positive and negative predictive values were 90%, 95%, 94%, 56%, and 99%, respectively, and area under the receiver operating characteristic curve was 0.93. The mean SI ratio of the lowest SI in the tumor to that of the renal cortex was significantly lower in the ≥2 score group (0.58) than in the 1 score group (1.36). CONCLUSIONS: MRI predicted RCC with SRCC with a moderate positive predictive value and a high negative predictive value.


Assuntos
Carcinoma de Células Renais/diagnóstico , Neoplasias Renais/diagnóstico , Imageamento por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Rim/patologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Curva ROC , Sensibilidade e Especificidade , Adulto Jovem
15.
Pol J Radiol ; 80: 67-71, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25691920

RESUMO

BACKGROUND: Recanalization occurs occasionally, following coil embolization of pulmonary arteriovenous malformations (PAVM), and can lead to ischemic stroke; therefore re-embolization is important. A 1.9-Fr. no-taper microcatheter that can be inserted into a 2.7-Fr. microcatheter (named the triaxial system) has recently become available, and contributes to super-selective catheterization for small or tortuous vessels. The aim of this study was to evaluate the usefulness of re-embolization for recanalization of PAVM using the triaxial system. MATERIAL/METHODS: Recanalization was diagnosed in 8 patients with 13 PAVMs between June 2011 and November 2012, and re-embolization was attempted with a conventional microcatheter at first in all 13 PAVMs. However, in three of them it failed with the conventional microcatheter, and then the system was exchanged to the triaxial system. Thus, re-embolization using the triaxial system was performed in 3 PAVMs of 3 female patients, with a median age of 63 years (range, 46-73 years). We assessed technical success, complications, and outcome. RESULTS: The disappearance of recanalization was confirmed by angiography in all re-embolization procedures (technical success rate was 100%). Re-embolization was then successfully achieved inside the original coils, and no branch artery of normal lung tissue was embolized. There were no complications related with this procedure. The blood flow of recanalization was decreased in all cases in a follow-up of 27-33 months (median, 31). CONCLUSIONS: Triaxial system appears to be useful for recanalization of PAVM, especially in difficult cases with a conventional system.

16.
J Vasc Interv Radiol ; 25(9): 1339-47, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25012936

RESUMO

PURPOSE: To assess the feasibility of time-resolved magnetic resonance (MR) angiography as a follow-up method after embolization for pulmonary arteriovenous malformations (PAVMs). MATERIALS AND METHODS: Evaluation of 28 PAVMs in 10 patients previously treated with embolization with platinum coils was performed. The mean observation period after embolization was 49 months. All patients underwent unenhanced chest computed tomography (CT) and time-resolved MR angiography followed by transcatheter digital subtraction angiography within 5 weeks for a definite diagnosis. Two radiologists reviewed the CT and time-resolved MR angiography findings using a blinded method. On CT, the draining veins of the PAVMs were measured before and after embolization, and shrinkage rates were calculated. On time-resolved MR angiography, recanalization was diagnosed when the draining vein or aneurysmal sac or both were enhanced in the pulmonary arterial phase. Correlations between recanalization, the shrinkage rate of the draining vein, and the diagnostic accuracies of CT and time-resolved MR angiography were assessed and compared with digital subtraction angiography. RESULTS: Five lesions could not be measured on CT because of metallic artifacts. The mean shrinkage rates of the draining vein for recanalized and occluded PAVMs were 23% ± 19 (SD) for recanalized PAVMs and 47% ± 21 for occluded PAVMs (P = .001). The sensitivity and specificity were 93% and 53%, respectively, when the shrinkage rate threshold was set to 50%. On time-resolved MR angiography, the sensitivity and specificity were 93% and 100%, respectively, for Reader 1 and 100% and 93%, respectively, for Reader 2. The κ coefficient was 0.86. CONCLUSIONS: Time-resolved MR angiography appears to be a feasible method for PAVM follow-up examinations and to provide a more accurate diagnosis of recanalization compared with unenhanced CT.


Assuntos
Malformações Arteriovenosas/diagnóstico , Malformações Arteriovenosas/terapia , Embolização Terapêutica/instrumentação , Angiografia por Ressonância Magnética/métodos , Platina , Artéria Pulmonar/anormalidades , Veias Pulmonares/anormalidades , Adulto , Idoso , Angiografia Digital , Artefatos , Embolização Terapêutica/efeitos adversos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/patologia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/patologia , Reprodutibilidade dos Testes , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
17.
Radiol Case Rep ; 19(4): 1404-1408, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38268739

RESUMO

Transthoracic echocardiography is the main imaging modality to diagnose left ventricular thrombus (LVT), but its efficacy in certain cases is suboptimal. We report a patient in whom an LVT, initially unidentified by transthoracic echocardiography, was successfully diagnosed with iodine maps derived from dual-source photon-counting detector CT (DS-PCD-CT). The 64-year-old male was admitted to our institution following myocardial infarction. Although TTE failed to detect this small LVT, iodine maps derived from CT angiography (which was conducted to evaluate the coronary artery stenosis) revealed its presence. Iodine maps derived from DS-PCD-CT collecting data with high temporal resolution are beneficial to diagnose LVTs.

18.
Radiol Case Rep ; 19(9): 3618-3621, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38983292

RESUMO

A 75-year-old male, weighing 71 kg, was admitted to our institution with anemia related to a subcapsular hematoma after accidental extraction of a nephrostomy catheter. While the patient exhibited the progression of chronic kidney disease, he was not yet on dialysis. His serum creatinine level increased to 6.8 mg/dL, with an estimated glomerular filtration rate of 7.4 mL/min/1.73 m2. Radiologists planned contrast-enhanced photon-counting detector CT (PCD-CT) with an ultra-low-dose contrast media to mitigate the impact on renal function. The contrast media dosage was set at 7.4 gI, which was 82.6% lower that used in the standard protocol for a male weighing 71 kg. Non-contrast-enhanced PCD-CT identified a low-density nodular area within the renal subcapsular hematoma. Contrast-enhanced PCD-CT revealed contrast enhancement in both the early and late phases corresponding to the nodular area. On virtual monoenergetic images, the renal pseudoaneurysm was most clearly delineated at 40 keV. Following the diagnosis of a pseudoaneurysm, transcatheter arterial coil embolization was performed. No subsequent progression of anemia or the deterioration of renal function was observed, showcasing the potential of ultra-low-dose contrast-enhanced PCD-CT for the detection of small vascular abnormalities while minimizing adverse effects on renal function.

19.
Sci Rep ; 14(1): 9283, 2024 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654028

RESUMO

We compared survival outcomes of high-dose concomitant boost radiotherapy (HDCBRT) and conventional dose radiotherapy (CRT) for newly diagnosed glioblastoma (GB). Patients treated with intensity-modulated radiation therapy for newly diagnosed GB were included. In HDCBRT, specific targets received 69, 60, and 51 Gy in 30 fractions, while 60 Gy in 30 fractions was administered with a standard radiotherapy method in CRT. Overall survival (OS) and progression-free survival (PFS) were compared using the Log-rank test, followed by multivariate Cox analysis. The inverse probability of treatment weighting (IPTW) method was also applied to each analysis. Among 102 eligible patients, 45 received HDCBRT and 57 received CRT. With a median follow-up of 16 months, the median survival times of OS and PFS were 21 and 9 months, respectively. No significant differences were observed in OS or PFS in the Kaplan-Meier analyses. In the multivariate analysis, HDCBRT correlated with improved OS (hazard ratio, 0.49; 95% confidence interval, 0.27-0.90; P = 0.021), and this result remained consistent after IPTW adjustments (P = 0.028). Conversely, dose suppression due to the proximity of normal tissues and IMRT field correlated with worse OS and PFS (P = 0.008 and 0.049, respectively). A prospective study with a stricter protocol is warranted to validate the efficacy of HDCBRT for GB.


Assuntos
Neoplasias Encefálicas , Glioblastoma , Radioterapia de Intensidade Modulada , Humanos , Glioblastoma/radioterapia , Glioblastoma/mortalidade , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Radioterapia de Intensidade Modulada/métodos , Adulto , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/mortalidade , Dosagem Radioterapêutica , Estimativa de Kaplan-Meier , Intervalo Livre de Progressão , Resultado do Tratamento
20.
Acta Radiol ; 54(8): 954-60, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23612431

RESUMO

BACKGROUND: The effects of a tin filter on virtual non-enhanced (VNE) images created by dual-energy CT have not been well evaluated. PURPOSE: To compare the accuracy of VNE images between those with and without a tin filter. MATERIAL AND METHODS: Two different types of columnar phantoms made of agarose gel were evaluated. Phantom A contained various concentrations of iodine (4.5-1590 HU at 120 kVp). Phantom B consisted of a central component (0, 10, 25, and 40 mgI/cm(3)) and a surrounding component (0, 50, 100, and 200 mgI/cm(3)) with variable iodine concentration. They were scanned by dual-source CT in conventional single-energy mode and dual-energy mode with and without a tin filter. CT values on each gel at the corresponding points were measured and the accuracy of iodine removal was evaluated. RESULTS: On VNE images, the CT number of the gel of Phantom A fell within the range between -15 and +15 HU under 626 and 881 HU at single-energy 120 kVp with and without a tin filter, respectively. With attenuation over these thresholds, iodine concentration of gels was underestimated with the tin filter but overestimated without it. For Phantom B, the mean CT numbers on VNE images in the central gel component surrounded by the gel with iodine concentrations of 0, 50, 100, and 200 mgI/cm(3) were in the range of -19-+6 HU and 21-100 HU with and without the tin filter, respectively. CONCLUSION: Both with and without a tin filter, iodine removal was accurate under a threshold of iodine concentration. Although a surrounding structure with higher attenuation decreased the accuracy, a tin filter improved the margin of error.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estanho , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sefarose
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA