Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Circ J ; 88(7): 1118-1124, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38616125

RESUMO

BACKGROUND: Despite an increased incidence of chronic heart failure (HF) and sudden cardiac death (SCD), the use of implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy (CRT) is much lower in Japan than in Western countries. The HF Indication and SCD Prevention Trial Japan (HINODE) prospectively assessed the mortality rate, appropriately treated ventricular arrhythmias (VA), and HF in Japanese patients with a higher risk of HF.Methods and Results: HINODE consisted of ICD, CRT-defibrillator (CRT-D), pacing, and non-device treatment cohorts. This subanalysis evaluated the impact of the implantation of high-voltage devices (HVD; ICD and CRT-D) in 171 Japanese patients. We compared all-cause mortality, VA, and HF events between elderly (age >70 years at study enrollment) and non-elderly HVD recipients. The estimated survival rate through 24 months in the HVD cohort was 85.8% (97.5% lower control limit 77.6%). The risk of all-cause mortality was increased for the elderly vs. non-elderly (hazard ratio [HR] 2.82; 95% confidence interval [CI] 1.01-7.91; P=0.039), but did not differ after excluding ICD patients with CRT-D indication (HR 2.32; 95% CI 0.79-6.78; P=0.11). There were no differences in VA and HF event-free rates between elderly and non-elderly HVD recipients (P=0.73 and P=0.55, respectively). CONCLUSIONS: Although elderly patients may have a higher risk of mortality in general, the benefit of HVD therapy in this group is comparable to that in non-elderly patients.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Idoso , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Masculino , Feminino , Japão/epidemiologia , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Prevenção Primária , Estudos Prospectivos , Morte Súbita Cardíaca/prevenção & controle , Fatores Etários , Fatores de Risco , População do Leste Asiático
2.
Pacing Clin Electrophysiol ; 42(7): 1018-1025, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31050004

RESUMO

BACKGROUND: Various lead designs have been developed to accommodate different coronary sinus anatomies. Our objectives were to compare electrical parameters of straight and spiral left ventricular leads, to evaluate capture thresholds and impedances using different pacing vectors, and to study evolution of thresholds over time. METHODS: The RALLY-X4 study enrolled patients implanted with a lead from the Acuity X4 family (straight, spiral short, or spiral long). Electrical parameters (including capture thresholds from all 17 vectors) were measured at baseline and follow-up. RESULTS: Data from 795 patients who were successfully implanted were analyzed. Straight and spiral leads had similar proportions of patients with thresholds <2.5 V/0.4 ms using the distal electrode (61-65% of patients) or from at least one of the proximal (E2-E4) electrodes (81-83% of patients). Unipolar vectors had significantly lower thresholds and impedances than bipolar vectors, with similar measurements compared to extended bipolar configurations. Capture thresholds increased with more proximal electrodes for all leads. Over a mean follow-up of 1 year, a slight decrease in capture thresholds was observed. CONCLUSION: Straight and spiral quadripolar leads allow to obtain clinically acceptable capture thresholds from at least one of the proximal electrodes in >80% of patients. Pacing vectors significantly affect electrical parameters, with higher thresholds in more proximal electrodes and lower thresholds with unipolar and extended bipolar configurations. Capture thresholds slightly decreased over a mean follow-up of 1 year.


Assuntos
Estimulação Cardíaca Artificial/métodos , Seio Coronário/anatomia & histologia , Eletrodos Implantados , Marca-Passo Artificial , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Vigilância de Produtos Comercializados
3.
Artigo em Inglês | MEDLINE | ID: mdl-38914900

RESUMO

BACKGROUND: Chronotropic incompetence (CI) is common among elderly cardiac resynchronization therapy pacemaker (CRT-P) patients on optimal medical therapy. This study aimed to evaluate the impact of optimized rate-adaptive pacing utilizing the minute ventilation (MV) sensor on exercise tolerance. METHODS: In a prospective, multicenter study, older patients (median age 76 years) with a guideline-based indication for CRT were evaluated following CRT-P implantation. If there was no documented CI, requiring clinically rate-responsive pacing, the device was programmed DDD at pre-discharge. At 1 month, a 6-min walk test (6MWT) was conducted. If the maximum heart rate was < 100 bpm or < 80% of the age-predicted maximum, the response was considered CI. Patients with CI were programmed with DDDR. At 3 months post-implant, the 6MWT was repeated in the correct respective programming mode. In addition, heart rate score (HRSc, defined as the percentage of all sensed and paced atrial events in the single tallest 10 bpm histogram bin) was assessed at 1 and 3 months. RESULTS: CI was identified in 46/61 (75%) of patients without prior indication at enrollment. MV sensor-based DDDR mode increased heart rate in CI patients similarly to non-CI patients with intrinsically driven heart rates during 6MWT. Walking distance increased substantially with DDDR (349 ± 132 m vs. 376 ± 128 m at 1 and 3 months, respectively, p < 0.05). Furthermore, DDDR reduced HRSc by 14% (absolute reduction, p < 0.001) in those with more severe CI, i.e., HRSc ≥ 70%. CONCLUSION: Exercise tolerance in older CRT-P patients can be further improved by the utilization of an MV sensor.

4.
ESC Heart Fail ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956896

RESUMO

AIMS: Hospitalizations are common in patients with heart failure and are associated with high mortality, readmission and economic burden. Detecting early signs of worsening heart failure may enable earlier intervention and reduce hospitalizations. The HeartLogic algorithm is designed to predict worsening heart failure using diagnostic data from multiple device sensors. The main objective of this analysis was to evaluate the sensitivity of the HeartLogic alert calculation in predicting worsening heart failure events (HFEs). We also evaluated the false positive alert rate (FPR) and compared the incidence of HFEs occurring in a HeartLogic alert state to those occurring out of an alert state. METHODS: The HINODE study enrolled 144 patients (81 ICD and 63 CRT-D) with device sensor data transmitted via a remote monitoring system. HeartLogic alerts were then retrospectively simulated using relevant sensor data. Clinicians and patients were blinded to calculated alerts. Reported adverse events with HF symptoms were adjudicated and classified by an independent HFE committee. Sensitivity was defined as the ratio of the number of detected usable HFEs (true positives) to the total number of usable HFEs. A false positive alert was defined as an alert with no usable HFE between the alert onset date and the alert recovery date plus 30 days. The patient follow-up period was categorized as in alert state or out of alert state. The event rate ratio was the HFE rate calculated in alert to out of alert. RESULTS: The patient cohort was 79% male and had an average age of 68 ± 12 years. This analysis yielded 244 years of follow-up data with 73 HFEs from 37 patients. A total of 311 HeartLogic alerts at the nominal threshold (16) occurred across 106 patients providing an alert rate of 1.27 alerts per patient-year. The HFE rate was 8.4 times greater while in alert compared with out of alert (1.09 vs. 0.13 events per patient-year; P < 0.001). At the nominal alert threshold, 80.8% of HFEs were detected by a HeartLogic alert [95% confidence interval (CI): 69.9%-89.1%]. The median time from first true positive alert to an adjudicated clinical HFE was 53 days. The FPR was 1.16 (95% CI: 0.98-1.38) alerts per patient-year. CONCLUSIONS: Results suggest that signs of worsening HF can be detected successfully with remote patient follow-up. The use of HeartLogic may predict periods of increased risk for HF or clinically significant events, allowing for early intervention and reduction of hospitalization in a vulnerable patient population.

5.
Heart Rhythm ; 20(3): 385-392, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36436813

RESUMO

BACKGROUND: Pacing at sites of longest interventricular delay has been associated with greater reverse remodeling in cardiac resynchronization therapy (CRT). However, the effects of pacing at such sites on clinical outcomes is less well studied. OBJECTIVE: The purpose of this study was to assess the association between interventricular delay and clinical outcomes in CRT patients implanted with quadripolar left ventricular (LV) leads. METHODS: RALLY-X4 was a registry study of the Acuity X4 quadripolar LV leads. Interventricular delay was measured during unpaced basal rhythm from the right ventricular (RV) lead to the LV lead electrode (E1 to E4) chosen for CRT pacing. Patients were stratified by median RV-LV delay (80 ms) into short and long delay groups; they also were analyzed by multivariable modeling. The primary composite outcome measure was all-cause mortality and heart failure hospitalization (HFH) at 18 months. RESULTS: A total of 581 patients had complete RV-LV delay data. Mean LV ejection fraction was 27%, and 73% had typical left bundle branch block. Predictors of long RV-LV delay included female sex, left bundle branch block, and QRS duration >150 ms. Survival free of the primary outcome at 18-month follow-up was 87% in the long activation delay group compared with 77% in the short delay group (P = .0042). Multivariate analysis showed that RV-LV delay was an independent predictor of survival free of HFH (P = .028). CONCLUSION: Among CRT patients with quadripolar LV pacing leads, longer baseline interventricular activation delay was significantly associated with the composite endpoint of all-cause mortality and HFH.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Feminino , Terapia de Ressincronização Cardíaca/efeitos adversos , Resultado do Tratamento , Bloqueio de Ramo , Função Ventricular Esquerda , Insuficiência Cardíaca/terapia
6.
Ann Noninvasive Electrocardiol ; 17(3): 176-85, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22816536

RESUMO

The implantable cardioverter defibrillator (ICD) is highly effective in reducing mortality due to cardiac arrhythmias in high-risk cardiac patients. However, inappropriate therapies caused predominantly by supraventricular tachyarrhythmias (SVTs) remain a significant side effect of ICD therapy despite medical treatment, affecting 8-40% of patients. The MADIT-RIT is a global, prospective, randomized, nonblinded, three-arm, multicenter clinical investigation to be performed in the Unites States, Europe, Canada, Israel and Japan, and will utilize approximately 90 centers with plan to enroll 1500 patients programmed to three treatment arms. The objective of the MADIT-RIT trial is to determine if dual-chamber ICD or CRT-D devices with high rate cutoff (MADIT-RIT-Arm B) and/or long delay in combination with detection enhancements (MADIT-RIT-Arm C) are associated with fewer patients experiencing inappropriate therapies than standard programming (MADIT-RIT-Arm A) during postimplant follow-up of patients with indication for primary prevention device therapy. This paper describes design and analytic plan for the MADIT-RIT trial.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/estatística & dados numéricos , Erros Médicos/prevenção & controle , Taquicardia Supraventricular/etiologia , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Canadá , Desfibriladores Implantáveis/efeitos adversos , Desenho de Equipamento , Segurança de Equipamentos , Europa (Continente) , Feminino , Humanos , Israel , Japão , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos , Valores de Referência , Medição de Risco , Análise de Sobrevida , Taquicardia Supraventricular/mortalidade , Resultado do Tratamento , Estados Unidos
7.
ESC Heart Fail ; 9(3): 1584-1596, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35365936

RESUMO

AIMS: The HINODE study aimed to analyse rates of mortality, appropriately treated ventricular arrhythmias (VA), and heart failure in Japanese patients and compared with those in Western patients. METHODS AND RESULTS: After treatment decisions following contemporary practice in Japan, patients were prospectively enrolled into four cohorts: (i) internal cardioverter-defibrillator (ICD), (ii) cardiac resynchronization therapy (CRT) defibrillator (CRT-D), (iii) standard medical therapy ('non-device': ND), or (iv) pacing (indicated for CRT; received pacemaker or CRT pacing). Cohorts 1-3 required a left ventricular ejection fraction ≤35%, a history of heart failure, and a need for primary prevention of sudden cardiac death based on two to five previously identified risk factors. Endpoint outcomes were adjudicated by the independent committees. ICD and CRT-D cohorts, considered as high-voltage (HV) cohorts, were pooled for Kaplan-Meier analysis and propensity-matched to Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) arm B and C patients. The study enrolled 354 patients followed for 19.6 ± 6.5 months, with a minimum of 12 months. Propensity-matched HV cohorts showed comparable VA (P = 0.61) and mortality rates (P = 0.29) for HINODE and MADIT-RIT. The ND cohort presented a high crossover rate to ICD therapy (6.1%, n = 7/115), and the CRT-D cohort showed elevated mortality rates. The pacing cohort revealed that patients implanted with pacemakers had higher mortality (26.0%) than those with CRT-Pacing (8.4%, P = 0.05). CONCLUSIONS: The mortality and VA event rates of landmark trials are applicable to patients with primary prevention in Japan. Patients who did not receive guideline-indicated CRT devices had poor outcomes.


Assuntos
Insuficiência Cardíaca , Função Ventricular Esquerda , Arritmias Cardíacas , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Humanos , Japão/epidemiologia , Volume Sistólico , Resultado do Tratamento
8.
J Arrhythm ; 37(4): 1031-1037, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34386129

RESUMO

BACKGROUND: Randomized trials in Western countries have provided evidence that prophylactic implantable cardioverter-defibrillator (ICD) therapy reduces mortality in heart failure (HF) patients with reduced left ventricular ejection fraction. However, the risk of life-threatening ventricular arrhythmias in Japanese HF patients sharing similar risk factors is still unknown. METHODS: The Heart Failure Indication and Sudden Cardiac Death Prevention Trial Japan trial (NCT03185832) is a prospective, multicenter registry designed to collect data on ventricular arrhythmia, HF events, and mortality in Japanese HF patients. Japanese patients with HF and 2-5 predefined risk factors who were indicated for cardiac device implantation based on European Society of Cardiology guidelines were enrolled in four treatment arms: implantable cardioverter-defibrillator (ICD), cardiac resynchronization therapy defibrillator (CRT-D), HF pacing (PA; Pacemaker and cardiac resynchronization pacemaker), and nondevice (ND) cohorts and followed for a minimum of 12 months. Since it is anticipated that some baseline patient characteristics and risk factors will differ significantly from those reported in predominantly Western populations, event rates will be compared to a propensity-matched population from the MADIT RIT trial. Primary endpoints are composite rates of first appropriately treated ventricular arrhythmias (VA) or/and life-threatening VA symptoms for the ICD and CRT-D cohorts. For nondevice and PA cohorts, the primary outcome is all-cause mortality. CONCLUSIONS: The Heart Failure Indication and Sudden Cardiac Death Prevention Trial Japan is a large prospective multicenter registry with defined device treatment cohorts and will provide data for risk stratification for cardiovascular events in Japanese HF patients.

9.
Eur Heart J ; 24(23): 2083-9, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14643268

RESUMO

OBJECTIVES: To evaluate the long-term outcome with an implantable atrial defibrillator (IAD) in patients with recurrent atrial fibrillation (AF). BACKGROUND: Maintenance of sinus rhythm using repeated internal cardioversion shocks has been shown to be effective and safe in short-term studies but long term follow-up is unknown. METHODS: Since 1995, 136 patients (30 women) with symptomatic, drug-refractory atrial fibrillation were implanted with an IAD (METRIX, InControl). This analysis was performed after a median of 40 (range 7-66) months after implantation. RESULTS: In 26 patients, the programmed mode was not documented during last follow-up, four patients had died. Of the remaining 106 patients (mean age 58+/-10, range 34 - 79 years), 39 were actively delivering therapy with the device, in 14 patients the device was used to monitor the arrhythmia but no shocks were delivered, and in 53 patients it was turned off or explanted. Increases in defibrillation thresholds (n=7), patient intolerance of multiple cardioversion shocks (n=15), and significant bradycardia requiring dual-chamber pacing (n=12) were the main reasons for discontinuation of therapy in addition to battery depletion (n=19). After explantation, efforts to maintain sinus rhythm were continued in 17 patients whereas rate control was attempted in 36 patients. CONCLUSIONS: A strategy of maintaining sinus rhythm long-term with an IAD is feasible in a proportion of patients. However, patient selection is critical, and technical improvements (i.e. higher shock energies, dual-chamber pacing and additional preventive and anti-tachycardia pacing algorithms) are required to increase the number of patients having long term benefit, and frequent arrhythmia recurrences and patient intolerance to repeated cardioversion shocks remain a major limitation.


Assuntos
Fibrilação Atrial/terapia , Desfibriladores Implantáveis , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Retratamento , Prevenção Secundária , Fatores de Tempo , Recusa do Paciente ao Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA