Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Natl Cancer Inst ; 90(11): 846-9, 1998 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-9625173

RESUMO

BACKGROUND: In randomized trials, screening mammography has led to decreased mortality from breast cancer. However, the low positive predictive value of mammography (i.e., the proportion of patients with a positive test result who actually have breast cancer) results in a large number of unnecessary biopsies. We determined whether scintimammography with technetium-99m-sestamibi is a useful supplemental diagnostic tool for women with nonpalpable breast abnormalities identified by conventional mammography. METHODS: Scintimammography was performed preoperatively on 70 women who were 31-66 years of age (mean age and median age = 51 years). These women had nonpalpable breast abnormalities identified by conventional mammography; subsequently, a needle-localization excisional biopsy of each suspicious lesion was performed. Scintimammographic images were interpreted independently by two nuclear medicine physicians who were blinded to all clinical and pathologic data, and an interobserver variation analysis was performed. RESULTS: Interobserver variation analysis of the scintimammographic findings showed an agreement for breast diagnosis of 97% and a kappa coefficient of 0.90. Comparison of scintimammographic findings and histopathologic results revealed that the sensitivity (proportion of patients with breast cancer who had a positive test result), the specificity (proportion of patients without breast cancer who had a negative test result), the positive predictive value and the negative predictive value (proportion of patients with a negative test result who actually did not have breast cancer) of scintimammography were 56% (95% confidence interval [CI] = 23%-85%), 87% (95% CI = 75%-94%), 38% (95% CI = 15%-68%), and 93% (95% CI = 82%-98%), respectively. Four of nine breast cancers were not detected by scintimammography. CONCLUSION: Because of excellent interobserver agreement, scintimammography provides an objective way of detecting primary breast carcinoma. In view of its low sensitivity and positive predictive value, however, scintimammography is not currently recommended as a screening test in patients with nonpalpable positive mammographic findings.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Tecnécio Tc 99m Sestamibi , Adulto , Idoso , Biópsia , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/patologia , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/patologia , Estudos de Avaliação como Assunto , Reações Falso-Negativas , Feminino , Humanos , Programas de Rastreamento , Pessoa de Meia-Idade , Variações Dependentes do Observador , Palpação , Valor Preditivo dos Testes , Cintilografia , Estudos Retrospectivos , Sensibilidade e Especificidade , Método Simples-Cego
2.
J Nucl Med ; 38(7): 1019-22, 1997 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9225782

RESUMO

UNLABELLED: Scintimammography with 99mTc-sestamibi can be used as a complementary technique to improve the mammogram's sensitivity and specificity for detection of breast carcinoma. We have observed in some patients focal areas of increased 99mTc-sestamibi uptake with no corresponding abnormalities on physical examination or mammogram. A phantom device and a special needle were designed to stereotactically localize these lesions before biopsy. METHODS: After intravenous injection of 30 mCI (1110 MBq) of 99m Tc-sestamibi, a prone lateral image of the abnormal breast was obtained. With the patient in the prone position, the breast was compressed with two fenestrated plates in the prone position. The x and y coordinates of the abnormal hot spot of the breast were determined. The z coordinate of focal 99mTc-sestamibi uptake was determined by advancing a localizer needle through a selected predetermined hole of the fenestrated plate using real-time visualization on the persistence monitor. The tip of the opturator inside the needle is welded with 57Co to determine the depth of the hot spot in the breast. RESULTS: Three women, all of whom had normal mammogram and breast physical examinations, were studied using 99mTc-sestamibi prone breast imaging. Pre-excisional biopsy needle localization of abnormal focal uptake was performed. Two women demonstrated infiltrative ductal carcinoma, and the third had proliferative fibrocystic disease of the breast. CONCLUSION: Our initial experience demonstrates that nuclear medicine guided stereotactic needle biopsy of the breast in patients with positive scintimammograms is technically feasible. In the future, this technology will enable us to detect breast carcinoma in the absence of clear-cut clinical and mammographic findings.


Assuntos
Biópsia por Agulha/métodos , Mama/diagnóstico por imagem , Mama/patologia , Mamografia , Técnicas Estereotáxicas , Adulto , Biópsia por Agulha/instrumentação , Feminino , Humanos , Pessoa de Meia-Idade , Imagens de Fantasmas , Cintilografia , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi
3.
J Nucl Med ; 36(10): 1784-9, 1995 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-7562043

RESUMO

UNLABELLED: Mammography and physical examination combined have a sensitivity of 85% for the detection of breast carcinoma. Mammography also has a positive predictive value of 15%-30%. The aim of this study was to evaluate the usefulness of scintimammography using 99mTc-sestamibi as a complementary technique to mammography for the detection of breast carcinoma to improve mammography's sensitivity and specificity. METHODS: We studied 100 consecutive patients (mean age 48.3 +/- 10.8 yr) who had 106 lesions warranting biopsy (67 lesions) or fine needle aspiration cytology (FNA) (39 lesions) of the breast. There were 85 palpable and 21 nonpalpable lesions. The size of the lesions on the mammograms were moderate (2.3 +/- 1.8 x 1.9 +/- 1.5 cm). Each patient received 20 mCi 99mTc-sestamibi intravenously. Five and 60 min postinjection, planar breast images in the lateral prone position were obtained. An anterior erect projection was then obtained to visualize the axilla and, if needed, a posterior oblique prone projection. RESULTS: Scintimammography was true-positive in 30 lesions with biopsy-confirmed breast carcinoma; it was true-negative in 65 lesions subsequently proved to be benign. There were nine breast lesions with benign findings in which the scintimammography result was positive (false-positive scintimammography) for cancer. Finally, two lesions with pathologically proven carcinomas demonstrated a negative scintimammographic result. Therefore, in this group, the sensitivity of scintimammography was 93.7% with a specificity of 87.8%; the positive predictive value was 76.9%. The negative predictive value was 97%. CONCLUSION: Scintimammography is a highly sensitive test that improves the specificity of conventional mammography for the detection of breast carcinoma.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi , Biópsia por Agulha , Mama/patologia , Neoplasias da Mama/patologia , Estudos de Coortes , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Radiografia , Cintilografia , Sensibilidade e Especificidade
4.
J Nucl Med ; 39(3): 449-53, 1998 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9529290

RESUMO

UNLABELLED: This study was undertaken to assess the relationship between the degree of 99mTc-MIBI uptake in breast lesions and the following histologic factors: neovascularity, desmoplastic reaction, cellular proliferation and mitochondrial density. METHODS: Forty-two patients who previously underwent MIBI breast imaging (4 false-negative, 12 false-positive, 15 true-negative, 11 true-positive) were studied. Immunohistochemical staining was performed for neovascularity (Factor VIII antigen), desmoplasia (alpha-actin antigen), mitochondrial density (mitochondrial antigen) and cellular proliferation (MIB-1 antigen). The degree of microscopic staining was correlated with region of interest measurements of MIBI uptake on scintigraphy. RESULTS: There was a poor correlation between MIBI uptake and the degrees of neovascularity (r = 0.08, p > 0.05) and intracellular mitochondrial density (r = 0.04, p > 0.05) while there was a moderate correlation with cellular proliferation (r = 0.4, p < 0.05) and desmoplasia (r = 0.55, p < 0.001). CONCLUSION: The degree of MIBI uptake in breast lesions is multifactorial, but it appears to be related more to the degree of desmoplastic activity and cellular proliferation than neovascularity and mitochondrial density.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Mama/diagnóstico por imagem , Mama/metabolismo , Mama/patologia , Doenças Mamárias/diagnóstico , Neoplasias da Mama/diagnóstico , Feminino , Humanos , Neovascularização Patológica/patologia , Cintilografia
5.
J Nucl Med ; 39(5): 849-56, 1998 May.
Artigo em Inglês | MEDLINE | ID: mdl-9591588

RESUMO

UNLABELLED: The purpose of our study was to compare the results of planar and SPECT scintimammography for the detection of breast carcinoma. In addition, our goal was to determine whether SPECT reconstructed with filtered backprojection (FBP) or with iterative algorithms (ISA) can improve the sensitivity and specificity of planar scintimammography (SMM). METHODS: One hundred thirteen patients with suspicious physical examinations and/or mammography underwent planar lateral and anterior breast imaging as well as SPECT imaging after injection of 99mTc-sestamibi. We used a blind evaluation, both separately and combined, for planar SMM, ISA-SPECT and FBP-SPECT. Scintigraphic findings were correlated with the final histopathological diagnoses. RESULTS: The sensitivity of planar SMM was 80% with a specificity of 83%. All ISA-SPECT studies were of diagnostic quality, while FBP-SPECT was considered nondiagnostic in 14 that were excluded for statistical calculation. Sensitivity of ISA-SPECT and FBP-SPECT were 71% and 69%, respectively. Specificity was 70% for ISA-SPECT and 66% for FBP-SPECT. Combined planar SMM plus ISA-SPECT sensitivity was 85% (81% for planar SMM plus FBP-SPECT) with a specificity of 72%. Three carcinomas indeterminate on planar SMM were correctly identified by combined planar SMM plus ISA-SPECT. ISA-SPECT and FBP-SPECT provided additional information to planar SMM with respect to localization of sestamibi uptake, tumor extent, improved diagnostic certainty and detection of axillary nodes in 40 and 14 patients, respectively. CONCLUSION: ISA reconstruction is the preferable approach to SPECT data. Combined with planar SMM, ISA-SPECT can improve sensitivity. SPECT is useful in cases of indeterminate and positive planar SMM.


Assuntos
Algoritmos , Neoplasias da Mama/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Doenças Mamárias/diagnóstico por imagem , Doenças Mamárias/epidemiologia , Neoplasias da Mama/epidemiologia , Feminino , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/métodos
6.
J Nucl Med ; 41(12): 1973-9, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11138681

RESUMO

UNLABELLED: Although mammography is well established as a first-line tool for breast cancer screening and detection, efforts to develop complementary procedures continue. Observation of 99mTc-sestamibi tumor uptake provided the impetus for its evaluation as an adjunctive technique. This trial's objectives were to determine in a multicenter trial the diagnostic accuracy of 99mTc-sestamibi in women with suspected breast cancer and to investigate factors influencing diagnostic accuracy. METHODS: Our multicenter trial enrolled 673 women (387 with nonpalpable abnormalities; 286 with palpable abnormalities) scheduled for excisional biopsy or mastectomy. Blinded and unblinded interpretations of scintigraphic images were compared with core laboratory established histopathologic diagnoses to define the diagnostic accuracy of 99mTc-sestamibi breast imaging. RESULTS: Blinded readers' diagnostic accuracy was 78%-81%. Inter-reader agreement was excellent, ranging from 95% to 100% (kappa = 0.82-0.99). Overall institutional sensitivity and specificity for 99mTc-sestamibi breast imaging were 75.4% and 82.7%, respectively. In this population with a 40.1% disease prevalence, the positive predictive value was 74.5% and the negative predictive value was 83.4%. The negative predictive value was 94% in patients with a 40% or lower mammographic likelihood of breast cancer. Sensitivity was higher for palpable abnormalities; specificity was higher for nonpalpable abnormalities. Sensitivity was decreased for tumors <1 cm in largest dimension but appeared not to be affected by patient's age. CONCLUSION: As an adjunct to current procedures, 99mTc-sestamibi breast imaging may contribute to patient management decisions in selected populations, including women with dense breasts, mammographically indeterminate lesions >1 cm, and palpable abnormalities.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Biópsia , Mama/patologia , Neoplasias da Mama/diagnóstico , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Cintilografia , Análise de Regressão , Sensibilidade e Especificidade
7.
Chest ; 107(5): 1336-41, 1995 May.
Artigo em Inglês | MEDLINE | ID: mdl-7750328

RESUMO

111-Indium-DTPA-IgG (111In-IgG) is a new radiopharmaceutical that has been evaluated for the detection of infection without the need for in vitro cell labeling. We prospectively studied this agent in 33 patients suspected of having lung infections, most of whom also had HIV infection, and three patients with HIV infection and diarrhea without lung disease. Anterior and posterior lung images in the upright position were obtained within 24 h after intravenous administration of 2 mCi of 111In-IgG and were read in a blinded fashion by two nuclear medicine physicians. Of 29 patients suspected to have Pneumocystis carinii pneumonia (PCP), the diagnosis was confirmed by bronchoalveolar lavage in 18. Diffusely increased lung uptake of 111In-IgG was found in 17 of 18 patients who had PCP and was normal in 10 of 11 patients without PCP. The intensity of 111In-IgG uptake was related to sever gas exchange abnormality. Two patients with apparent bacterial lung infections had focal accumulation of 111In-IgG while two patients with minor radiographic abnormalities had no increased uptake. Normal lung uptake also occurred in two of three HIV-positive patients who had diarrhea and no lung disease. 111In-IgG appears to be useful in the detection of PCP and other pulmonary infections.


Assuntos
Infecções Oportunistas Relacionadas com a AIDS/diagnóstico por imagem , Infecções por HIV/diagnóstico por imagem , Imunoglobulina G , Radioisótopos de Índio , Pulmão/diagnóstico por imagem , Ácido Pentético/análogos & derivados , Pneumonia por Pneumocystis/diagnóstico por imagem , Adulto , Humanos , Imunoglobulina G/metabolismo , Radioisótopos de Índio/metabolismo , Pulmão/metabolismo , Pneumopatias/diagnóstico por imagem , Masculino , Ácido Pentético/metabolismo , Estudos Prospectivos , Cintilografia , Sensibilidade e Especificidade
8.
J Am Coll Surg ; 178(5): 491-7, 1994 May.
Artigo em Inglês | MEDLINE | ID: mdl-8167887

RESUMO

Mammography and physical examination have a sensitivity of 85 percent for detection of carcinoma of the breast. Mammography also has a positive predictive value of 15 to 30 percent. The aim of this study was to evaluate the usefulness of scintimammography (SMM) as a screening technique for the detection of carcinoma of the breast and compare the test's sensitivity and specificity with that of mammography. We conducted SMM on 59 female patients in whom abnormal mammogram and physical examination warranted biopsy of the breast or fine needle aspiration cytology of the breast, or both. Each patient received 20 millicuries of 99mTc Sestamibi intravenously. Five and sixty minutes postinjection, planar breast images in lateral and posterior oblique views were obtained. In 23 patients with biopsy-confirmed carcinoma of the breast, the SMM result was positive. In 33 patients with benign breast lesions, no increased uptake of Sestamibi was noted in the breast. Five other patients with benign lesions of the breast had false-positive scans. There was one patient with an intraductal carcinoma and a cluster of microcalcifications on mammography without an associated mass, for whom the 99mTc Sestamibi scan was negative. In the group of patients studied, the sensitivity of SMM was 95.8 percent, specificity was 86.8 percent, positive predictive value was 82.1 percent and, most importantly, the negative predictive value for the detection of carcinoma of the breast was 97.1 percent. We conclude in this pilot study that SMM is a highly sensitive test that improves the specificity of conventional mammography for the detection of carcinoma of the breast and deserves further study as a screening technique to potentially reduce the number of mammographically "indicated" biopsies of the breast that yield negative results for carcinoma.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Mamografia/métodos , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Projetos Piloto , Decúbito Ventral , Estudos Prospectivos , Cintilografia , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi
9.
Radiol Clin North Am ; 39(5): 1053-68, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11587058

RESUMO

Mammography remains the imaging modality of choice in detection of early, nonpalpable breast cancer. Scintimammography using SPECT, however, may prove to be a very useful adjunct to a nondiagnostic or difficult mammogram. Further prospective studies have to be designed so that the specific clinical applications of this technique are more defined. As with any new imaging procedure, special care to obtain high-quality scintimammographic studies and sufficient training of staff to perform and interpret the imaging are necessary.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão , Tomografia Computadorizada de Emissão de Fóton Único
10.
Cancer Biother Radiopharm ; 14(6): 435-42, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10850330

RESUMO

Breast cancer is the most important malignancy for women of the world's industrialized nations. It is second only to lung cancer in cancer-related mortality. Early detection is the best means of improving survival; the cornerstone of early diagnosis is mammography. Given the endemic nature of breast cancer, screening mammography has secured a routine place in health maintenance for women, although it is less than perfect. To aid in the diagnosis of malignant breast disease, other imaging modalities have evolved: ultrasound, magnetic resonance imaging (MRI), positron emission tomography (PET), and SMM. Scintimammography (SMM) is rapidly with a variety of applications for the management of breast disease. This technology has become a complementary modality to other conventional methods of breast imaging. This review will focus on the science behind SMM and how it is currently used in the management of breast lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico , Feminino , Humanos , Imageamento por Ressonância Magnética , Radiografia , Cintilografia , Tomografia Computadorizada de Emissão , Ultrassonografia
11.
Am Surg ; 67(12): 1204-8, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11768831

RESUMO

The ability to recognize multicentric breast cancer preoperatively would assist in identifying appropriate candidates for breast conservation surgery. Tc-99m scintimammography (SMM) is an adjunct to conventional mammography in identifying selected patients with breast cancer. The purpose of this study is to report the utility of SMM in identifying patients with multicentric breast cancer. Breast cancer patients treated by mastectomy who underwent a preoperative SMM between 1992 and 1999 were identified using the institution's Tumor Registry. The pathology report of each patient was reviewed for multicentric disease defined as an additional focus of cancer within a different quadrant of the breast or greater than 2.5 cm from the dominant tumor mass. Each patient's preoperative SMM was reviewed and compared with the pathologic findings to obtain correlative data. Fifty-eight women treated by mastectomy had preoperative SMM (age range 35-78 years; median 52 years). Pathology revealed infiltrating ductal carcinoma in 49 patients (84.5%), infiltrating lobular carcinoma in five patients (8.6%), ductal carcinoma in situ in three patients (5.1%), and colloid carcinoma in one patient (1.7%). Multicentric disease was present in the specimens of eight patients for a prevalence of 10.3 per cent. SMM was positive for uptake in 36 of 58 patients (sensitivity 62.1%). The sensitivity, specificity, positive predictive value, and negative predictive value of SMM in the detection of multicentric disease were 62.5, 96, 71, and 94 per cent, respectively. Although the overall sensitivity of SMM in the detection of breast cancer is superior to that of conventional mammography and physical examination in identifying multicentric breast cancer it is not an accurate modality for detecting multicentric disease in this study group. However, it may have limited applications in specific cases.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Cintilografia , Sensibilidade e Especificidade
12.
Am Surg ; 63(10): 850-3, 1997 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9322655

RESUMO

Several investigators have advocated management of breast cancer patients without axillary dissection, obviating the morbidity associated with this procedure. Approximately 30-40 per cent of all patients with breast carcinoma will have lymph node metastasis. Axillary dissection offers no therapeutic benefit to node-negative patients, and it may lead to unnecessary morbidity. It is apparent that a noninvasive test to determine the presence of axillary metastases may obviate the need for axillary dissection. The aim of this study was to determine the role of scintimammography (SMM) with technetium-99m sestamibi in the detection of axillary node metastasis in breast carcinoma. Thirty-one women with the diagnosis of breast carcinoma who had SMM and axillary lymphadenectomy were included. SMM was done following an intravenous injection of 20 mCi of Tc-99m sestamibi. Planar scintigraphic imaging was acquired in a lateral prone and an anterior view of the breasts for the evaluation of the axilla. SMM scans were interpreted by two nuclear medicine physicians blinded to the clinical presentation and histologic results. The correlation of SMM with histologic assessment showed a sensitivity of 75 per cent, specificity of 82 per cent, positive predictive value of 88 per cent, and negative predictive value of 64 per cent. The interobserver correlation of SMM interpretation between the two nuclear medicine physicians showed good agreement, with kappa = 0.49. Consistency in the interpretation of Tc-99m SMM was obtained when two independent radiologists reviewed the studies. Based on these data, we are unable to show that SMM is a reliable test for the detection of axillary metastases in patients with breast cancer. However, a high positive value of 88 per cent is encouraging and deserves further study.


Assuntos
Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/secundário , Metástase Linfática/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Adulto , Idoso , Axila , Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/cirurgia , Estudos de Avaliação como Assunto , Feminino , Previsões , Humanos , Injeções Intravenosas , Excisão de Linfonodo , Mastectomia Radical Modificada , Mastectomia Segmentar , Pessoa de Meia-Idade , Medicina Nuclear , Variações Dependentes do Observador , Valor Preditivo dos Testes , Decúbito Ventral , Radiologia , Cintilografia , Compostos Radiofarmacêuticos/administração & dosagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego , Tecnécio Tc 99m Sestamibi/administração & dosagem
13.
Nucl Med Commun ; 23(7): 609-11, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12089481

RESUMO

Early diagnosis of carcinoma of the breast is currently attempted by mammography and physical examination which together have a sensitivity of 85%. Mammography has a positive predictive value of only 15 to 40 percent. The usefulness of scintimammography for the detection of carcinoma of the breast has been studied which demonstrated improved specificity compared to conventional mammography. In future, with the development or dedicated breast imager and new targeted radiopharmaceuticals, we can achieve detection of smaller than 1 cm carcinoma. This type of imaging enables us to detect cancer at its 'pre-anatomic' stage.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Neoplasias da Mama/diagnóstico , Reações Falso-Positivas , Feminino , Humanos , Sensibilidade e Especificidade
14.
Nucl Med Commun ; 17(8): 717-23, 1996 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-8878134

RESUMO

The aim of this study was to design and assess a scintigraphy-guided stereotaxic localization technique for breast phantoms. We wished to develop and validate scintigraphically aided biopsy of non-palpable breast masses identified only by sestamibi scintimammography. A biopsy table was built for patients to lie prone with the breast in a dependent position. The breast can be compressed in the cranial and caudal directions by fenestrated paddles. Three freely adjustable radioactive reference lines, placed along the x, y and z axes, each containing about 30 MBq (800 micro Ci) 99Tcm, were mounted on sliding rules on the external frame which surrounded the phantom. The breast phantom was a semi-square-shaped sponge. Background activity was provided by a sponge cloth containing 37 MBq (1 mCi) 99Tcm solution. Non-palpable lesions were carved out of the same sponge and wrapped in thin plastic film, and labelled with about 11 MBq (300 microCi) 201T1. The lesions, 3-15 mm in size, were placed at random at phantom depths of 2-6 cm by an individual different from the person performing the localization. Scintigraphy-guided three-dimensional localization of the lesion was performed by acquiring two orthogonal images and superimposing the reference bars over the lesion image and thus identifying the exact x, y and z coordinates of the lesion. Using these coordinates, a 22 gauge needle, containing about 37 MBq (1 mCi) 99Tcm within its lumen, was stereotactically placed into the phantom, and the tracer contained in the needle injected into the lesion. Needle placement was primarily guided by the exact coordinates, but also by real-time visualization of the radioactive needle. Pre- and post-localization images were acquired and regions of interest (ROIs) defined. Also after the tracer was injected into the lesion, images of the phantom with and without the lesion were obtained to calculate the percentage of tracer injected outside the lesion. The results of 30 consecutive localization attempts included 25 exact localizations with less than 20% tracer injected outside the lesion, 2 "near misses' with 37-44% injected outside the lesion, and 3 "misses' with 60, 85 and 100% of the tracer being injected outside the lesion. The missed localizations were all in lesions at least 4 cm deep, and all had partially superimposed ROIs, which indicates the needle came very close to the lesion. To conclude, our scintigraphy-guided biplane localization technique for breast phantom lesions successfully localized 90% of all lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas Estereotáxicas , Biópsia/métodos , Neoplasias da Mama/diagnóstico , Estudos de Avaliação como Assunto , Feminino , Humanos , Injeções Intralesionais , Imagens de Fantasmas , Cintilografia , Técnicas Estereotáxicas/instrumentação , Tecnécio/administração & dosagem
15.
Nucl Med Commun ; 19(1): 55-62, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9515547

RESUMO

The aim of this study was to evaluate whether scintimammography using 99Tc(m)-sestamibi or contrast-enhanced magnetic resonance imaging (MRI) can improve the specificity of mammography for the differentiation of benign and malignant breast microcalcification. From 156 consecutive patients studied with SMM, 44 patients with microcalcification on mammograms were selected for this study. Forty patients in this group also had contrast-enhanced MRI of the breast. The intensity and patterns of sestamibi uptake for scintimammography and contrast enhancement for MRI were visually determined and graded on a 5-point scale for malignancy. The results of both techniques were compared and correlated with final histopathologic diagnoses. The sensitivity and specificity of scintimammography were 63% and 85% respectively, if only those cases classified as probable or definite malignancy were considered positive. If indeterminate findings were also considered positive, the sensitivity and specificity of scintimammography were 79% and 80% respectively. Using the latter classification for MRI revealed a comparable sensitivity of 82% but a markedly lower specificity of 56%. Excluding indeterminate findings from the group of positive MRI diagnoses resulted in a specificity of 94% and a sensitivity of 64%. In conclusion, scintimammography of the breast had a comparable sensitivity but a higher specificity than MRI. The sensitivity of both techniques, however, is probably too low for routine use in the evaluation of microcalcification detected by mammography.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Neoplasias da Mama/diagnóstico , Calcinose/diagnóstico por imagem , Carcinoma in Situ/diagnóstico , Carcinoma Ductal de Mama/diagnóstico , Imageamento por Ressonância Magnética , Adulto , Idoso , Mama/diagnóstico por imagem , Mama/patologia , Doenças Mamárias/diagnóstico , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Calcinose/diagnóstico , Carcinoma in Situ/diagnóstico por imagem , Carcinoma in Situ/patologia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/patologia , Diagnóstico Diferencial , Feminino , Doença da Mama Fibrocística/diagnóstico , Doença da Mama Fibrocística/diagnóstico por imagem , Doença da Mama Fibrocística/patologia , Humanos , Mamografia , Pessoa de Meia-Idade , Cintilografia , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi
16.
Clin Nucl Med ; 20(7): 583-6, 1995 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-7554656

RESUMO

Of 507 breast scintimammograms performed using Tc-99m sestamibi, 34 patients were incidentally found to have abnormal appearing thyroid glands. The authors sought to investigate the clinical significance and/or ascertain an extraneous causative factor for these findings. One cold thyroid nodule was detected and was proven benign through biopsy. Two cases of subacute and chronic thyroiditis were proven, and it is possible that additional patients had this disease process. Focal areas of increased thyroid Tc-99m sestamibi uptake were observed in eight patients and probably represent parathyroid adenomas, nonautonomous hyperfunctioning thyroid nodules, or nontoxic multinodular goiter. The results did not yield an extraneous causative factor, underlying pathology, or clinically significant disease in all of the patients investigated, but the findings suggest a need for careful evaluation of any unusual uptake in the thyroid gland and the rest of the image. The authors do not recommend investigation of all abnormal appearing thyroid glands on Tc-99m sestamibi scintimammography. However, clinical correlation should be recommended.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi , Glândula Tireoide/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Cintilografia
20.
Eur J Nucl Med ; 21(4): 357-62, 1994 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8005161

RESUMO

Imaging techniques currently used for the diagnosis of breast cancer are reviewed and compared. Besides mammography, magnetic resonance imaging, positron emission tomography, and thallium-201 scintimammography, a new role of technetium-99m sestamibi scintimammography is discussed. It is concluded that while mammography remains the procedure of choice in screening asymptomatic women for breast cancer, other imaging methods play an important role in detecting malignancies in symptomatic patients. 99mTc-sestamibi scintimammography has high sensitivity and improves the specificity of conventional mammography for the detection of breast cancer; with this technique, prone imaging is preferable to supine imaging. 99mTc-sestamibi scintimammography thus deserves further study as a screening technique.


Assuntos
Neoplasias da Mama/diagnóstico , Diagnóstico por Imagem , Tecnécio Tc 99m Sestamibi , Adulto , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Cintilografia , Sensibilidade e Especificidade , Radioisótopos de Tálio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA