Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 113
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Opt Lett ; 48(14): 3657-3660, 2023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-37450718

RESUMO

We propose a novel, to the best of our knowledge, distance recovery method via swept frequency mixing for frequency-modulated continuous wave (FMCW) light detection and ranging (LiDAR) to overcome the Nyquist limit and obtain high data efficiency. A one dimensional (1D) experiment was conducted to recover the optical fiber length; in addition, a 3D image was obtained by recovering the distances of several targets in free space. Compared to conventional methods based on fast Fourier transform (FFT), beat frequency up to 14 times the Nyquist limit for sampling frequency was successfully measured without aliasing. The proposed method dramatically increases the data efficiency in FMCW LiDAR by reducing the number of complex algorithms and experimental resources required.


Assuntos
Algoritmos , Fibras Ópticas
2.
Sensors (Basel) ; 23(18)2023 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-37765785

RESUMO

We recently developed a novel hyperspectral excitation-resolved near-infrared fluorescence imaging system (HER-NIRF) based on a continuous-wave wavelength-swept laser. In this study, this technique is applied to measure the distribution of the therapeutic agent dimethyl sulfoxide (DMSO) by utilizing solvatochromic shift in the spectral profile of albumin-bound Indocyanine green (ICG). Using wide-field imaging in turbid media, complex dynamics of albumin-bound ICG are measured in mixtures of dimethyl sulfoxide (DMSO) and water. Phantom experiments are conducted to evaluate the performance of the HER-NIRF system. The results show that the distribution of DMSO can be visualized in the wide-field reflection geometry. One of the main purposes of the DMSO is to act as a carrier for other drugs, enhancing their effects by facilitating skin penetration. Understanding the solubility and permeability of drugs in vivo is very important in drug discovery and development. Hence, this HER-NIRF technique has great potential to advance the utilization of the therapeutic agent DMSO by mapping its distribution via the solvatochromic shift of ICG. By customizing the operational wavelength range, this system can be applied to any other fluorophores in the near-infrared region and utilized for a wide variety of drug delivery studies.


Assuntos
Dimetil Sulfóxido , Verde de Indocianina , Imagem Óptica/métodos , Corantes Fluorescentes , Pele
3.
Sensors (Basel) ; 23(14)2023 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-37514935

RESUMO

Photoacoustic imaging has emerged as a promising biomedical imaging technique that enables visualization of the optical absorption characteristics of biological tissues in vivo. Among the different photoacoustic imaging system configurations, optical-resolution photoacoustic microscopy stands out by providing high spatial resolution using a tightly focused laser beam, which is typically transmitted through optical fibers. Achieving high-quality images depends significantly on optical fluence, which is directly proportional to the signal-to-noise ratio. Hence, optimizing the laser-fiber coupling is critical. Conventional coupling systems require manual adjustment of the optical path to direct the laser beam into the fiber, which is a repetitive and time-consuming process. In this study, we propose an automated laser-fiber coupling module that optimizes laser delivery and minimizes the need for manual intervention. By incorporating a motor-mounted mirror holder and proportional derivative control, we successfully achieved efficient and robust laser delivery. The performance of the proposed system was evaluated using a leaf-skeleton phantom in vitro and a human finger in vivo, resulting in high-quality photoacoustic images. This innovation has the potential to significantly enhance the quality and efficiency of optical-resolution photoacoustic microscopy.

4.
Plant Dis ; 2021 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-33406858

RESUMO

In October 2018, cucumber plants showing yellowing and chlorotic mottle symptoms were observed in a greenhouse in Chungbuk, South Korea. The observed symptoms were similar to those caused by cucurbit aphid-borne yellows virus (CABYV), which has been detected on cucumber plants in the region since it was reported on melon in Korea in 2015 (Lee et al 2015). To identify the potential agents causing these symptoms, 28 samples from symptomatic leaves and fruit of cucumber plants were subjected to total RNA extraction using the Plant RNA Prep Kit (Biocubesystem, Korea). Reverse transcription polymerase chain (RT-PCR) was performed on total RNA using CABYV specific primers and protocols (Kwak et al. 2018). CABYV was detected in 17 of the 28 samples, while 11 symptomatic samples tested negative. In order to identify the cause of the symptoms, RT-PCR was performed using cucurbit chlorotic yellows virus (CCYV) and cucurbit yellow stunting disorder virus (CYSDV) specific primers (Wintermantel et al. 2019). Eight of the 28 samples were positive using the CCYV specific primers while seven samples were infected with only CCYV and one contained a mixed infection of CABYV with CCYV. None of the samples tested positive for CYSDV. The expected 373 nt amplicons of CCYV were bi-directionally sequenced, and BLASTn analysis showed that the nucleotide sequences shared 98 to 100% identity with CCYV isolates from East Asia, including NC0180174 from Japan. Two pairs of primers for amplification of the complete coat protein and RNA-dependent RNA polymerase (RdRp) genes (Wintermantel et al., 2019) were used to amplify the 753bp coat protein and 1517bp RdRp genes, respectively. Amplicons of the expected sizes were obtained from a CCYV single infection and ligated into the pGEM T- Easy vector (Promega, WI, USA). Three clones from each amplicon were sequenced and aligned using Geneious Prime and found to have identical sequences (Genbank accession nos. MW033300, MW033301). The CP and RdRp sequences demonstrated 99% nucleotide and 100% amino acid identity with the respective genes and proteins of the CCYV isolates from Japan. This study documents the first report of CCYV in Korea. Since CCYV was first detected on melon in Japan, it has been reported in many other countries including those in East Asia, the Middle East, Southern Europe, North Africa, and recently in North America. CCYV has the potential to become a serious threat to production of cucurbit crops in Korea, particularly due to the increasing prevalence of the whitefly, Bemisia tabaci, in greenhouse production systems. It will be important to continue monitoring for CCYV and determine potential alternate hosts in the region to manage and prevent further spread of CCYV in Korea.

5.
Opt Lett ; 45(19): 5327-5330, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33001885

RESUMO

We report on an akinetic actively-mode-locked wavelength-swept laser (ASL) with a sweep that is highly linear in wavenumber. By tailoring the drive waveform of the intracavity modulator, the wavenumber sweep was further linearized to enable high fidelity frequency-domain interferometric ranging without resampling of the acquired data. Used for catheter-based optical coherence tomography, the ASL showed comparable imaging performance to a state-of-the-art polygon-based wavelength-swept source at a matching sweep rate of 103.6 kHz, a duty cycle of 95%, and a bandwidth of 100 nm, centered at 1330 nm.

6.
Sensors (Basel) ; 20(24)2020 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-33371378

RESUMO

Chromatic confocal microscopy (CCM) has been intensively developed because it can exhibit effective focal position scanning based on the axial chromatic aberration of broadband light reflected from a target. To improve the imaging speed of three-dimensional (3D) surface profiling, we have proposed the novel concept of swept-source-based CCM (SS-CCM) and investigated the usefulness of the corresponding imaging system. Compared to conventional CCM based on a broadband light source and a spectrometer, a swept-source in the proposed SS-CCM generates light with a narrower linewidth for higher intensity, and a single photodetector employed in the system exhibits a fast and sensitive response by immediately obtaining spectrally encoded depth from a chromatic dispersive lens array. Results of the experiments conducted to test the proposed SS-CCM system indicate that the system exhibits an axial chromatic focal distance range of approximately 360 µm for the 770-820 nm swept wavelength range. Moreover, high-speed surface profiling images of a cover glass and coin were successfully obtained with a short measurement time of 5 ms at a single position.

7.
Can Vet J ; 60(6): 619-624, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31156262

RESUMO

The purpose of this retrospective cross-sectional study was to assess the diagnostic yield of ultrasound-guided aspiration of the medial retropharyngeal lymph node (MRPLN) and to report factors on computed tomography (CT) evaluation that are predictive of obtaining a diagnostic sample. A secondary objective was to report CT size reference ranges for cytologically confirmed normal MRPLNs in dogs. Medical records and CT images of 69 dogs were retrospectively reviewed. The diagnostic yield of ultrasound-guided aspiration on MRPLNs was 47.5%. Six lymph nodes were positive for metastasis with various cancers. Only rostral height was predictive of the diagnostic yield. The Pearson correlation coefficient and Spearman's Rho tests suggested that the age of the dog has significant negative linear correlation with the size of MRPLNs while the weight has positive correlation. Overall, ultrasound-guided aspiration of MRPLN has low diagnostic yield in normal size lymph nodes. Prior case selection based on CT evaluation may increase the probability of diagnostic samples.


Efficacité de l'aspiration guidée par échographie des ganglions lymphatiques rétro-pharyngiens médiaux et caractéristiques de la tomodensitométrie chez les chiens. Le but de cette étude transversale rétrospective était d'évaluer les résultats diagnostiques de l'aspiration guidée par échographie des ganglions lymphatiques rétropharyngiens médiaux (GLRM) et de faire rapport sur les facteurs de l'évaluation par tomodensitométrie qui sont prédicteurs de l'obtention d'un échantillon diagnostique. Un objectif secondaire était de faire rapport sur les écarts de référence de taille de la tomographie par ordinateur pour les GLRM confirmés normaux par cytologie chez les chiens. Les dossiers médicaux et les images de la tomodensitométrie de 69 chiens ont été évalués rétrospectivement. Le résultat diagnostique de l'aspiration guidée par échographie des GLRM était de 47,5 %. Six ganglions lymphatiques étaient positifs pour la présence de métastase de divers cancers. Seule la taille rostrale était prédictive du résultat diagnostique. Le coefficient de corrélation de Pearson et les tests Rho de Spearman ont suggéré que l'âge du chien avait une corrélation linéaire significativement négative avec la taille des GLRM tandis que le poids avait une corrélation positive. En général, l'aspiration guidée par échographie des GRLM présente un faible rendement diagnostique pour les ganglions lymphatiques de taille normale. Une sélection des cas préalable fondée sur l'évaluation de la tomodensitométrie pourra accroître la probabilité des échantillons diagnostiques.(Traduit par Isabelle Vallières).


Assuntos
Linfonodos , Ultrassonografia de Intervenção/veterinária , Animais , Estudos Transversais , Cães , Metástase Linfática , Estudos Retrospectivos
8.
Opt Express ; 26(5): 5789-5799, 2018 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-29529780

RESUMO

We demonstrate an unfolding displacement measurement method to overcome the aliasing problem of wavelength-comb-swept laser (WCSL). Compared to the conventional wavelength-swept laser (WSL), the WCSL exhibits an extended coherence length, owing to the narrowing spectral linewidth of the etalon filter. However, the aliasing interference signal induces an unexpected back-bounced phenomenon during displacement measurement because of the discretely distributed comb-like periodic spectra of the etalon filter. By using the dual-reference interferometry method, the back-bounced displacement measurement can be successfully unfolded to extend the measurement range by two times. In addition, we demonstrate a longer-range surface profiling image over 18 mm within the 200 mm of measurement range using a line-field beam of a parallel-swept source-optical coherence tomography system.

9.
Opt Lett ; 43(21): 5476-5479, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30383038

RESUMO

We demonstrate a real-time surface plasmon resonance imaging (SPRi) system based on a wavelength-swept laser. Compared to conventional spectral-modulation SPRi using white light source and spectral filtering, the proposed system has a higher scan rate to detect rapid changes in refractive index and a higher output power for large-area illumination. This SPRi system achieves scan rates faster than 12 Hz, simultaneously obtaining SPR dip positions over full illumination fields of 12×12 mm. Using the wavelength-swept laser, two-dimensional biomolecular array imaging can be acquired with a high dynamic detection range (7.67×10-3 refractive index unit (RIU)) as well as high sensitivity (6501 nm/RIU) and resolution (1.89×10-6 RIU).

10.
Sensors (Basel) ; 18(12)2018 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-30477260

RESUMO

A new type of quasi-distributed sensor system is implemented using an active mode locking (AML) laser cavity with multiple partially reflecting segments. The mode locking frequency of the AML laser is linearly proportional to the overall lasing cavity length. To implement multiple resonators having multiple reflection points installed in a sensing fiber, two types of partial reflectors (PRs) are implemented for an in-line configuration, one with fiber Bragg grating and the other with a fiber Fabry⁻Perot interferometer. Since the laser has oscillated only when the modulation frequencies for the mode locking frequency match with the corresponding resonator lengths, it is possible to read the multiple partially reflecting segments along the sensing fiber. The difference between two corresponding mode locking frequencies is changing proportionally with the segment length variation between two PRs upon strain application. The segment length change caused by the applied strain can be successfully measured with a linear sensitivity between mode locking frequency and displacement, linearity over 0.99, and spatial position resolution below meter order.

11.
Sensors (Basel) ; 17(12)2017 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-29182570

RESUMO

Diffuse optical tomography (DOT) has been studied for use in the detection of breast cancer, cerebral oxygenation, and cognitive brain signals. As optical imaging studies have increased significantly, acquiring imaging data in real time has become increasingly important. We have developed frequency-division multiplexing (FDM) DOT systems to analyze their performance with respect to acquisition time and imaging quality, in comparison with the conventional time-division multiplexing (TDM) DOT. A large tomographic area of a cylindrical phantom 60 mm in diameter could be successfully reconstructed using both TDM DOT and FDM DOT systems. In our experiment with 6 source-detector (S-D) pairs, the TDM DOT and FDM DOT systems required 6.18 and 1 s, respectively, to obtain a single tomographic data set. While the absorption coefficient of the reconstruction image was underestimated in the case of the FDM DOT, we experimentally confirmed that the abnormal region can be clearly distinguished from the background phantom using both methods.

12.
Sensors (Basel) ; 17(4)2017 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-28362318

RESUMO

We demonstrate a novel wavelength-comb-swept laser based on two intra-cavity filters: an acousto-optic tunable filter (AOTF) and a Fabry-Pérot etalon filter. The AOTF is used for the tunable selection of the output wavelength with time and the etalon filter for the narrowing of the spectral linewidth to extend the coherence length. Compared to the conventional wavelength-swept laser, the acousto-optic-based wavelength-comb-swept laser (WCSL) can extend the measureable range of displacement measurements by decreasing the sensitivity roll-off of the point spread function. Because the AOTF contains no mechanical moving parts to select the output wavelength acousto-optically, the WCSL source has a high wavenumber (k) linearity of R² = 0.9999 to ensure equally spaced wavelength combs in the wavenumber domain.

13.
Can Vet J ; 58(10): 1059-1064, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28966355

RESUMO

This retrospective study evaluated the outcomes of dogs with macroscopic pulmonary metastasis of appendicular osteosarcoma (OSA) treated with toceranib. Medical records of 20 dogs with macroscopic pulmonary metastasis of OSA that received toceranib were reviewed. The median dose and duration of toceranib administration were 2.52 mg/kg (range: 2.12 to 2.72 mg/kg) and 60 days (range: 17 to 231 days). The median progression free survival (PFS) and overall survival (OS) were 36 days (range: 17 to 231 days) and 90 days (range: 17 to 433 days), respectively. The clinical benefit rate was 10% (2/20; 1 partial response and 1 stable disease). The longest length of initial pulmonary nodules had significant impact on both PFS (P = 0.01) and OS (P = 0.02). The prognosis for dogs with metastatic OSA was poor with only 10% of dogs showing clinical benefit from toceranib. These results suggest that toceranib may not improve outcome in dogs with macroscopic pulmonary metastasis of OSA.


Évaluation rétrospective du traitement avec tocéranib (Palladia) pour l'ostéosarcome appendiculaire métastatique canin. Cette étude rétrospective a évalué les résultats des chiens souffrant de métastase pulmonaire macroscopique de l'ostéosarcome appendiculaire (OSE) traité avec tocéranib. Les dossiers médicaux de 20 chiens atteints de métastase pulmonaire macroscopique d'OSE qui ont reçu tocéranib ont été évalués. La dose médiane et la durée de l'administration de tocéranib étaient de 2,52 mg/kg (étendue de 2,12 à 2,72 mg/kg) et de 60 jours (étendue de 17 à 231 jours). La progression de survie libre (PSL) médiane et la survie totale (ST) étaient de 36 jours (étendue de 17 à 231 jours) et de 90 jours (étendue de 17 à 433 jours), respectivement. Le taux de bienfaits cliniques étaient de 10 % (2/20; 1 réponse partielle et 1 maladie stable). Le plus long intervalle avant l'apparition des nodules pulmonaires initiaux avait un impact important sur la PSL (P = 0,01) et la ST (P = 0,02). Le pronostic pour les chiens atteints d'OSE métastatique était mauvais et seulement 10 % des chiens ont manifesté des bienfaits cliniques lors de l'usage de tocéranib. Ces résultats suggèrent que le tocéranib pourraient ne pas améliorer les résultats cliniques chez les chiens souffrant de métastase pulmonaire macroscopique causée par OSE.(Traduit par Isabelle Vallières).


Assuntos
Neoplasias Ósseas/veterinária , Doenças do Cão/tratamento farmacológico , Indóis/uso terapêutico , Osteossarcoma/veterinária , Pirróis/uso terapêutico , Animais , Neoplasias Ósseas/tratamento farmacológico , Cães , Feminino , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/veterinária , Masculino , Osteossarcoma/tratamento farmacológico , Estudos Retrospectivos , Resultado do Tratamento
14.
Opt Express ; 24(2): 1053-61, 2016 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-26832489

RESUMO

High-speed frequency-domain terahertz (THz) coherence tomography is demonstrated using frequency sweeping of continuous-wave THz radiation and beam steering. For axial scanning, THz frequency sweeping with a kHz sweep rate and a THz sweep range is executed using THz photomixing with an optical beat source consisting of a wavelength-swept laser and a distributed feedback laser diode. During the frequency sweep, frequency-domain THz interferograms are measured using coherent homodyne detection employing signal averaging for noise reduction and used as axial-scan data via fast Fourier transform. Axial-scan data are acquired while scanning a transverse range of 100 × 100 mm(2) by use of a THz beam scanner with moving neither sample nor THz transmitter/receiver unit. It takes 100 s to acquire axial-scan data for 100 × 100 points with 5 averaged traces at a sweep rate of 1 kHz. THz tomographic images of a glass fiber reinforced polymer sample with artificial internal defects are presented, acquired using the tomography system.

15.
Sensors (Basel) ; 16(1)2016 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-26805840

RESUMO

We have developed a modified optical frequency domain imaging (OFDI) system that performs parallel imaging of three-dimensional (3D) surface profiles by using the space division multiplexing (SDM) method with dual-area swept sourced beams. We have also demonstrated that 3D surface information for two different areas could be well obtained in a same time with only one camera by our method. In this study, double field of views (FOVs) of 11.16 mm × 5.92 mm were achieved within 0.5 s. Height range for each FOV was 460 µm and axial and transverse resolutions were 3.6 and 5.52 µm, respectively.

16.
Opt Express ; 23(11): 14806-14, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-26072839

RESUMO

We present a new technical implementation of a high-speed broadband frequency sweep of continuous-wave terahertz (THz) radiation. THz frequency sweeping with a kHz sweep rate and a THz sweep range is implemented using THz photomixing in which an optical beat source consists of a wavelength-swept laser and a distributed feedback laser diode. During the frequency sweep, frequency-domain THz interferograms are measured using the coherent homodyne detection employing signal averaging for noise reduction, which can give time-of-flight information via fast Fourier transform. Multiple reflections in a Si wafer and the thickness of the wafer are measured to demonstrate the potential of this method for fast THz tomography and thickness measurement.

17.
Arch Virol ; 160(2): 587-90, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25300414

RESUMO

The complete genome sequence of a new virus isolated from a motherwort plant exhibiting yellow mottle, mild mosaic, and stunting symptoms in Andong, Korea, was determined. The genome of this virus is composed of two single-stranded RNAs (7068 and 4963 nucleotides in length, respectively) carrying poly(A) tails. RNA1 contains one large open reading frame (RNA1-ORF1), while two potential ORFs (RNA2-ORF1 and RNA2-ORF2) were found in RNA2. BLAST searches of protein databases showed that RNA1-ORF1 and RNA2-ORF2 have maximum amino acid sequence identities of 53 % and 57 % to the RNA1-ORF1 and RNA2-ORF2, respectively, of lettuce necrotic leaf curl virus (LNLCV, a recently identified torradovirus). Phylogenetic analysis provided further evidence that the virus identified in this study is probably a member of a new species in the genus Torradovirus. The name "motherwort yellow mottle virus" (MYMoV) is proposed for this new virus.


Assuntos
Genoma Viral/genética , Leonurus/virologia , Doenças das Plantas/virologia , Vírus de Plantas/genética , Vírus de RNA/genética , Sequência de Aminoácidos , Sequência de Bases , Sequenciamento de Nucleotídeos em Larga Escala , Fases de Leitura Aberta/genética , Filogenia , Vírus de Plantas/classificação , Vírus de RNA/classificação , RNA Viral/genética , Análise de Sequência de RNA , Homologia de Sequência de Aminoácidos , Proteínas Virais/genética
18.
Arch Virol ; 160(12): 3139-42, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26370789

RESUMO

The complete genome sequence of a new virus isolated from a bellflower (Campanula takesimana) plant was determined. The genome of this virus is composed of monopartite single-stranded RNA of 11,649 nucleotides in length. BLAST searches of protein databases showed that the encoded polyprotein has a maximum amino acid sequence identity of 42% (with 99% coverage) to the polyprotein of the isolate Orissa of rice tungro spherical virus (RTSV; genus Waikavirus). Phylogenetic analysis strongly supports that the identified virus is a member of a new species of the genus Waikavirus. The name bellflower vein chlorosis virus (BVCV) is proposed for this new virus.


Assuntos
Campanulaceae/virologia , Genoma Viral , Doenças das Plantas/virologia , Waikavirus/genética , Waikavirus/isolamento & purificação , Sequência de Bases , Dados de Sequência Molecular , Fases de Leitura Aberta , Filogenia , Waikavirus/classificação
19.
Plant Dis ; 99(5): 588-592, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-30699686

RESUMO

Tomato yellow leaf curl virus (TYLCV), one of the most serious plant viruses in tropical and subtropical regions, is transmitted to host plants by the vector insect Bemisia tabaci. In order to control TYLCV, it is important to identify weed hosts for overwintering TYLCV. Stellaria aquatica, a winter-hardy weed, was found growing with TYLCV-infected tomato plants in greenhouse production. TYLCV was detected in S. aquatica plants by polymerase chain reaction and Southern blot hybridization analysis. The intergenic region nucleotide sequences amplified from TYLCV-infected tomato plants, TYLCV-viruliferous whiteflies, and S. aquatica were identical. During winter (December to February), TYLCV-viruliferous whiteflies and TYLCV-infected tomato plants were removed or absent from greenhouses. However, S. aquatica plants were observed over a period of 10 months from August to May in such greenhouses, and TYLCV was consistently detected in some of these plants. To investigate the transmission of TYLCV from TYLCV-infected S. aquatica plants to healthy tomato plants by whiteflies, TYLCV-infected S. aquatica plants were transplanted to pots in cages with nonviruliferous whiteflies and healthy tomato plants. After 4 weeks, tomato plants developed typical TYLCV disease symptoms, and TYLCV was detected in both whiteflies and tomato plants. These results show that S. aquatica can act as a winter-hardy reservoir for TYLCV, and suggest that this weed could play an important role in overwintering of TYLCV in tomato greenhouses.

20.
Opt Lett ; 39(21): 6094-7, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-25361287

RESUMO

We demonstrate a novel concept of wavelength-spacing tuning of a dual-wavelength active-mode locking fiber laser in the 1.3-µm wavelength region. A dual-cavity configuration is implemented using a chirped fiber Bragg grating pair for wavelength-spacing tuning. Both normal and anomalous dispersion cavities were schematically designed for wavelength-spacing tuning ranging from 3.52-33.54 nm. The side-mode suppression ratio was ∼30 dB for both wavelengths. Because of the filter-less tuning mechanism, a fast repletion rate of wavelength-spacing sweeping and switching was demonstrated for frequencies up to 50 kHz.


Assuntos
Tecnologia de Fibra Óptica , Lasers , Fenômenos Ópticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA