RESUMO
BACKGROUND: Blood loss occurs significantly more frequently during total hip and knee arthroplasty than among any other type of orthopedic operation, which can sometimes lead to requiring a blood transfusion. Although allogeneic blood transfusion has been identified as a risk factor for postoperative surgical-site infection following arthroplasty, results are inconclusive. The purpose of this study was to conduct a systematic meta-analysis to investigate whether having an allogeneic blood transfusion significantly increases the risk for surgical-site infection, particularly after total hip and knee arthroplasty. METHODS: We performed a systematic review and meta-analysis using random-effect models. Using an electronic database search, we selected 6 studies that included data on 21,770 patients and among these studies compared the postoperative infection rate between an allogeneic blood-transfusion exposure group and a nonexposure group. We calculated the pooled odds ratios and 95% confidence intervals for the groups. RESULTS: The prevalences of surgical-site infections in our pooled analyses were 2.88% and 1.74% for the transfusion and nontransfusion groups, respectively. The allogeneic blood transfusion group had a significantly higher frequency of surgical-site infections based on pooled analysis using a random-effect model (pooled odds ratio = 1.71, 95% confidence interval: 1.23-2.40, P = .002). CONCLUSION: Allogeneic blood transfusion is a significant risk factor for increasing the surgical-site infection rate after total hip and knee arthroplasty.
Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Infecção da Ferida Cirúrgica/etiologia , Reação Transfusional , Humanos , Fatores de Risco , Transplante Homólogo/efeitos adversosRESUMO
PURPOSE: To assess the efficacy of continuous epidural infusion analgesia (ED) with 0.2 % Ropivacaine versus IV PCA (Fentanyl) in spinal fusion surgery patients. METHOD: A prospective randomized comparative clinical trial. Patients were randomized into one of two groups-the epidural group (ED-51 patients) and the IV PCA group (IV-43 patients). The epidural catheter tip was placed one level cephalad to the level of the PLIF in patients in the ED group. Patients were assessed by determining the pain score, cumulative opioid requirement, adverse effects, and satisfaction. RESULTS: Pain score comparisons between the ED group and the IV group, respectively, were as follows: immediate postoperative status: 2.1 ± 1.5 vs. 7.2 ± 2.1, p = 0.01; postoperative day 1: 2.3 ± 1.9 vs. 6.8 ± 2.3, p = 0.02; postoperative day 2: 1.9 ± 1.8 vs. 5.4 ± 2.1, p = 0.02; postoperative day 3: 1.5 ± 1.6 vs. 3.9 ± 1.9, p = 0.03; postoperative day 4: 3.8 ± 2.1 vs. 3.1 ± 1.9, p = 0.4. Lower levels of opioids were required in the ED group, and fewer opioid-related complications developed in the patients in this group. Complications related to the use of epidural catheters were comparable between the two groups. Patient satisfaction with postoperative pain control was higher in the ED group. CONCLUSION: In comparison with the use of IV PCA only, continuous epidural infusion of Ropivacaine resulted in lower pain scores and opioid consumption and higher patient satisfaction levels after posterior lumbar interbody fusion.
Assuntos
Amidas/uso terapêutico , Analgesia Epidural , Anestésicos Locais/uso terapêutico , Cateteres de Demora , Dor Pós-Operatória/prevenção & controle , Fusão Vertebral , Idoso , Analgésicos Opioides/uso terapêutico , Descompressão Cirúrgica , Uso de Medicamentos , Feminino , Humanos , Vértebras Lombares/cirurgia , Masculino , Satisfação do Paciente , Estudos Prospectivos , Ropivacaina , Escala Visual AnalógicaRESUMO
This study involved 35 knees undergoing biplane medial open-wedge high tibial osteotomy (OWHTO) to assess the axial rotation of the distal tibia. The distal tibiae were internally rotated by 3.0° ± 7.1° after OWHTO. The opening width showed a Pearson correlation coefficient of -0.743 (P < .001), and the tuberosity osteotomy angle showed that of -0.678 (P < .001) with distal tibial rotation. However, changes in hip-knee-ankle angle, medial proximal tibial angle, and posterior tibial slope were not significantly correlated with the change in distal tibial rotation. In conclusion, there was an unintended tendency of increasing internal rotation of the distal tibia after biplane medial OWHTO, and this tendency was positively related to the opening width and tuberosity osteotomy angle.
Assuntos
Articulação do Tornozelo/cirurgia , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Osteotomia/métodos , Tíbia/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Estudos Prospectivos , Radiografia , Rotação , Tíbia/fisiologiaRESUMO
A signal transformation system of posture movement for the stable state was designed in order to measure the bio-physical signal. To estimate the subject in a stable state on the basis of the bio-physical signal in the posture movement, the conditions of vision, vestibular, somatosensory apparatus and the central nervous system (CNS) were detected. Based on the vision condition, there was a greater average variation (Vi-αAVG-MAX and Vi-αAVG-MIN) in position with eyes closed and eyes opened (PC and PO), which was 27.11 ± 6.36 units. The vestibular condition showed a slightly larger average variation (Ve-αAVG-MAX and Ve-αAVG-MIN) in the body position with PC and PO, which was 6.60 ± 1.65 units. The somatosensory condition demonstrated a lower average variation (So-αAVG-MAX and So-αAVG-MIN) in position with PC and PO that amounted to 3.653 ± 2.424 units. The CNS condition was confirmed to indicate very little average variation (C-αAVG-MAX and C-αAVG-MIN) in body position with PC and PO that was at 0.401 ± 0.56 units. As the model depends on the bio-physical transformation system of posture movement, the average values of these perturbations were computed (0.01-2 Hz, range of Fourier frequency). The system consists of a data algorithm, an acquisition system, a data signal processing unit and a network system for the evaluated stability.
RESUMO
BACKGROUND: Glaucoma, is the most common cause of irreversible visual deficits, presents as an injury to the optic nerve and it is mainly associated with elevated intraocular pressure. The main symptom of glaucoma is a reduction of the visual field, which is usually a source of complaint at the advanced stage of disease. Because of visual deficit, gait dysfunctions, including low gait speed and increased bumping into objects, postural sway, and falling are occurred. Many studies have used stopwatch or motion-sensing devices to report on gait function following glaucoma. However, there are few reports on gait dysfunction assessed by examining foot pressure. This study investigated gait ability following glaucoma according to different gait conditions by assessing foot pressure. METHODS: Thirty older adults (15 in the sex- and age-matched normal group and 15 in the glaucoma group) were recruited for this study. All participants were walked under 2 different gait conditions in an F-scan system and the subject' assessments were randomly assigned to rule out the order effect. Conditions included: gait over an obstacle in a straight 6âm path, gait in a straight path without an obstacle in the 6âm path. Gait variables included cadence, gait cycle, stance time, center of force (COF) deviation, and COF excursion. About 10âminutes were taken for gait evaluation. RESULTS: When walking without an obstacle on a 6âm path, there were significant differences between the 2 groups in gait speed, cadence, gait cycle, and stance time (Pâ<â.05). There were significant differences when walking with an obstacle on a 6âm path (Pâ<â.05). Two-way analysis of variance showed significant effects associated with "glaucoma" not gait condition on all outcomes except for COF deviation and excursion. Also, there was no the interaction effect between "glaucoma" and "gait condition." CONCLUSION: We demonstrated that glaucoma patients selected the gait strategy such as lower gait function in both gait conditions particularly, slower gait speed and cadence and longer gait cycle and stance time, as determined by examining foot pressure. We believe that our results could help to improve the quality of life of patients with glaucoma.
Assuntos
Pé/fisiopatologia , Marcha/fisiologia , Glaucoma/fisiopatologia , Qualidade de Vida , Sapatos , Caminhada/fisiologia , Idoso , Fenômenos Biomecânicos , Estudos Transversais , Feminino , Humanos , Masculino , Equilíbrio Postural/fisiologia , Pressão , Velocidade de Caminhada/fisiologiaRESUMO
There are several reported disadvantages with conventional-length femoral stems in cementless total hip arthroplasty (THA). Therefore, various efforts have been made to develop a specific femoral short stem to improve physiologic bone remodeling at the femoral aspect of a cementless THA. However, there are potential disadvantages with specific femoral short stems, such as malalignment, inadvertent subsidence, and potential proximal femoral fracture. Therefore, the authors quantitatively compared radiographic and clinical outcomes as well as component-specific complications between 2 groups of patients following primary cementless THA. A matched comparison was made between specific femoral short stems (n=50) and conventional-length femoral stems (n=50) in cementless THA procedures performed between January 2008 and January 2012. Patients were matched for age, sex, body mass index, height, surgical approach, and surgeon. No significant differences were found between the 2 groups in mean postoperative radiographic outcomes, functional outcomes, or complications. Both groups showed satisfactory performance at 5-year follow-up. Specific femoral short stems resulted in a higher incidence of malalignment and subsidence and a lower incidence of thigh pain and proximal bone resorption compared with conventional-length femoral stems. Although longer follow-up is required, specific femoral short stems may have clinical and radiographic advantages with equivalent perioperative complications relative to conventional-length femoral stems. However, this technique requires proper patient selection in combination with careful preoperative planning and meticulous surgical technique.