Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 390
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(7): 1079-1087, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38639154

RESUMO

BACKGROUND: The number of octogenarians referred to percutaneous coronary interventions (PCI) is rising steadily. The prevalence and prognostic impact of complex PCI (CPCI) in this vulnerable population has not been fully evaluated. METHODS: Patients ≥80 years old who underwent PCI between 2012 and 2019 at Mount Sinai Hospital were included. Patients were categorized based on PCI complexity, defined as the presence of at least one of the following criteria: use of atherectomy, total stent length ≥60 mm, ≥3 stents implanted, bifurcation treated with at least 2 stents, PCI involving ≥3 vessels, ≥3 lesions, left main, saphenous vein graft or chronic total occlusion. The primary outcome was major adverse cardiovascular events (MACE), a composite of all-cause death, myocardial infarction (MI), or target-vessel revascularization (TVR), within 1 year after PCI. Secondary outcomes included major bleeding. RESULTS: Among 2657 octogenarians, 1387 (52%) underwent CPCI and were more likely to be men and to have cardiovascular risk factors or comorbidities. CPCI as compared with no-CPCI was associated with a higher 1-year risk of MACE (16.6% vs. 11.1%, adjusted HR 1.3, 95% CI 1.06-1.77, p value 0.017), due to an excess of MI and TVR, and major bleeding (10% vs. 5.8%, adjusted HR 1.64, 95% CI 1.20-2.55, p value 0.002). CONCLUSIONS: Among octogenarians, CPCI was associated with a significantly higher 1-year risk of MACE, due to higher rates of MI and TVR but not of all-cause death, and of major bleeding. Strategies to reduce complications should be implemented in octogenarians undergoing CPCI.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Intervenção Coronária Percutânea/instrumentação , Feminino , Idoso de 80 Anos ou mais , Resultado do Tratamento , Fatores Etários , Prevalência , Fatores de Tempo , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Medição de Risco , Fatores de Risco , Estudos Retrospectivos , Stents , New York/epidemiologia , Hemorragia
2.
Catheter Cardiovasc Interv ; 103(2): 260-267, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38173300

RESUMO

BACKGROUND: Among patients undergoing percutaneous coronary intervention (PCI), in-stent restenosis (ISR) is related with a worse prognosis, while higher body mass index (BMI) values are associated with better outcomes. It is unclear whether the prognostic impact of ISR varies in function of BMI. METHODS: Patients undergoing PCI at a large center from 2012 to 2019 not presenting with an acute myocardial infarction (MI) were included. Subjects with BMI < 18.5 kg/m2 or treated with bare metal stents were excluded. Patients were stratified according to type of lesion treated (ISR vs. no-ISR) and into four BMI categories: normal weight (BMI 18.5-25 kg/m2 ), overweight (25.0-29.9 kg/m2 ), class I obesity (30.0-34.9 kg/m2 ), class II-III obesity (≥35.0 kg/m2 ). The primary outcome was major adverse cardiovascular events (MACE), a composite of all-cause death, MI, and target vessel revascularization (TVR) at 1 year. RESULTS: Out of 16,234 patients, 3694 (23%) underwent PCI for ISR. ISR as compared to no-ISR was associated with a consistent increased risk of MACE within the normal weight (18.8% vs. 7.8%, adj. hazard ratio (HR): 1.99, 95% confidence interval [CI]: 1.51-2.64), overweight (19.1% vs. 6.4%, adj. HR: 2.35, 95% CI: 1.91-2.88), class I obesity (18.3% vs. 6.8%, adj. HR: 1.95, 95% CI: 1.47-2.57), and class II-III obesity (16.4% vs. 7.4%, adj. HR: 1.61, 95% CI: 1.09-2.37) groups (interaction p-value: 0.192). The ISR-related risks were mostly driven by an excess of TVR. CONCLUSIONS: At 1 year, ISR was associated with an increased risk of MACE irrespective of BMI, mostly due to an excess of TVR after ISR.


Assuntos
Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Prognóstico , Sobrepeso/complicações , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Fatores de Risco , Stents Farmacológicos/efeitos adversos , Resultado do Tratamento , Obesidade/complicações , Obesidade/diagnóstico , Angiografia Coronária/efeitos adversos
3.
Catheter Cardiovasc Interv ; 103(3): 425-434, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38314901

RESUMO

BACKGROUND: Peripheral artery disease (PAD) is associated with worse outcomes after percutaneous coronary intervention (PCI). The aim of this study was to assess the prognostic impact of PAD according to high bleeding risk (HBR) status. METHODS: Consecutive patients undergoing PCI with drug-eluting stent implantation at a tertiary-care center (Mount Sinai Hospital) between 2012 and 2019 were stratified according to HBR and PAD status. The primary outcome was major adverse cardiac events (MACE), a composite of all-cause death, myocardial infarction (MI), and stroke 1 year after PCI. Secondary outcomes included major bleeding. RESULTS: Out of 16,750 patients, 43% were HBR and 57% were no-HBR. Within the two groups, PAD patients were 14% and 6%, respectively, and were more likely to have comorbidities and to undergo complex PCI than no-PAD patients. Within the HBR group, PAD was associated with an increased risk of MACE (11.4% vs. 7.3%, hazard ratio [HR]: 1.59, 95% confidence interval [CI]: 1.27-1.99, p < 0.001) and a numerical nonsignificant increase of major bleeding (8.5% vs. 6.9%, HR: 1.25, 95% CI: 0.98-1.59, p = 0.066) as compared with no-PAD. Among no-HBR patients, rates of MACE and major bleeding were numerically but not significantly higher in the PAD group. After multivariable adjustment, PAD was no longer a predictor of adverse outcomes, irrespective of HBR status. CONCLUSIONS: At 1-year after PCI, PAD was associated with increased 1-year risks of MACE in HBR patients. After adjustment for cardiovascular risk factors and comorbidities, the effect of PAD on adverse events was largely attenuated.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença Arterial Periférica , Humanos , Prognóstico , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/induzido quimicamente , Intervenção Coronária Percutânea/efeitos adversos , Stents Farmacológicos/efeitos adversos , Resultado do Tratamento , Hemorragia/induzido quimicamente , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/terapia , Inibidores da Agregação Plaquetária/efeitos adversos , Fatores de Risco
4.
N Engl J Med ; 382(2): 130-139, 2020 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-31733182

RESUMO

BACKGROUND: Subclinical leaflet thickening and reduced leaflet motion of bioprosthetic aortic valves have been documented by four-dimensional computed tomography (CT). Whether anticoagulation can reduce these phenomena after transcatheter aortic-valve replacement (TAVR) is not known. METHODS: In a substudy of a large randomized trial, we randomly assigned patients who had undergone successful TAVR and who did not have an indication for long-term anticoagulation to a rivaroxaban-based antithrombotic strategy (rivaroxaban [10 mg] plus aspirin [75 to 100 mg] once daily) or an antiplatelet-based strategy (clopidogrel [75 mg] plus aspirin [75 to 100 mg] once daily). Patients underwent evaluation by four-dimensional CT at a mean (±SD) of 90±15 days after randomization. The primary end point was the percentage of patients with at least one prosthetic valve leaflet with grade 3 or higher motion reduction (i.e., involving >50% of the leaflet). Leaflet thickening was also assessed. RESULTS: A total of 231 patients were enrolled. At least one prosthetic valve leaflet with grade 3 or higher motion reduction was found in 2 of 97 patients (2.1%) who had scans that could be evaluated in the rivaroxaban group, as compared with 11 of 101 (10.9%) in the antiplatelet group (difference, -8.8 percentage points; 95% confidence interval [CI], -16.5 to -1.9; P = 0.01). Thickening of at least one leaflet was observed in 12 of 97 patients (12.4%) in the rivaroxaban group and in 33 of 102 (32.4%) in the antiplatelet group (difference, -20.0 percentage points; 95% CI, -30.9 to -8.5). In the main trial, the risk of death or thromboembolic events and the risk of life-threatening, disabling, or major bleeding were higher with rivaroxaban (hazard ratios of 1.35 and 1.50, respectively). CONCLUSIONS: In a substudy of a trial involving patients without an indication for long-term anticoagulation who had undergone successful TAVR, a rivaroxaban-based antithrombotic strategy was more effective than an antiplatelet-based strategy in preventing subclinical leaflet-motion abnormalities. However, in the main trial, the rivaroxaban-based strategy was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than the antiplatelet-based strategy. (Funded by Bayer; GALILEO-4D ClinicalTrials.gov number, NCT02833948.).


Assuntos
Valva Aórtica/fisiopatologia , Aspirina/farmacologia , Clopidogrel/farmacologia , Inibidores do Fator Xa/farmacologia , Próteses Valvulares Cardíacas , Inibidores da Agregação Plaquetária/farmacologia , Rivaroxabana/farmacologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/efeitos dos fármacos , Valva Aórtica/patologia , Aspirina/efeitos adversos , Aspirina/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Clopidogrel/uso terapêutico , Quimioterapia Combinada , Inibidores do Fator Xa/efeitos adversos , Inibidores do Fator Xa/uso terapêutico , Feminino , Tomografia Computadorizada Quadridimensional , Hemorragia/induzido quimicamente , Humanos , Análise de Intenção de Tratamento , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Rivaroxabana/efeitos adversos , Rivaroxabana/uso terapêutico , Tromboembolia/etiologia , Tromboembolia/mortalidade
5.
N Engl J Med ; 382(2): 120-129, 2020 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-31733180

RESUMO

BACKGROUND: Whether the direct factor Xa inhibitor rivaroxaban can prevent thromboembolic events after transcatheter aortic-valve replacement (TAVR) is unclear. METHODS: We randomly assigned 1644 patients without an established indication for oral anticoagulation after successful TAVR to receive rivaroxaban at a dose of 10 mg daily (with aspirin at a dose of 75 to 100 mg daily for the first 3 months) (rivaroxaban group) or aspirin at a dose of 75 to 100 mg daily (with clopidogrel at a dose of 75 mg daily for the first 3 months) (antiplatelet group). The primary efficacy outcome was the composite of death or thromboembolic events. The primary safety outcome was major, disabling, or life-threatening bleeding. The trial was terminated prematurely by the data and safety monitoring board because of safety concerns. RESULTS: After a median of 17 months, death or a first thromboembolic event (intention-to-treat analysis) had occurred in 105 patients in the rivaroxaban group and in 78 patients in the antiplatelet group (incidence rates, 9.8 and 7.2 per 100 person-years, respectively; hazard ratio with rivaroxaban, 1.35; 95% confidence interval [CI], 1.01 to 1.81; P = 0.04). Major, disabling, or life-threatening bleeding (intention-to-treat analysis) had occurred in 46 and 31 patients, respectively (4.3 and 2.8 per 100 person-years; hazard ratio, 1.50; 95% CI, 0.95 to 2.37; P = 0.08). A total of 64 deaths occurred in the rivaroxaban group and 38 in the antiplatelet group (5.8 and 3.4 per 100 person-years, respectively; hazard ratio, 1.69; 95% CI, 1.13 to 2.53). CONCLUSIONS: In patients without an established indication for oral anticoagulation after successful TAVR, a treatment strategy including rivaroxaban at a dose of 10 mg daily was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than an antiplatelet-based strategy. (Funded by Bayer and Janssen Pharmaceuticals; GALILEO ClinicalTrials.gov number, NCT02556203.).


Assuntos
Aspirina/uso terapêutico , Clopidogrel/uso terapêutico , Inibidores do Fator Xa/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Rivaroxabana/uso terapêutico , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Aspirina/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Quimioterapia Combinada , Inibidores do Fator Xa/efeitos adversos , Feminino , Próteses Valvulares Cardíacas , Hemorragia/induzido quimicamente , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Rivaroxabana/efeitos adversos , Tromboembolia/mortalidade
6.
Am Heart J ; 263: 26-34, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37094668

RESUMO

BACKGROUND: The TWILIGHT trial (NCT02270242) demonstrated that in selected high-risk patients undergoing percutaneous coronary intervention (PCI) ticagrelor monotherapy significantly reduced bleeding complications without ischemic harm as compared to ticagrelor plus aspirin after 3-month of dual antiplatelet therapy. The aim of this analysis was to assess the applicability of the findings TWILIGHT trial to a real-world population. METHODS: Patients undergoing PCI at a tertiary center between 2012 and 2019 and not meeting any TWILIGHT exclusion criterion (oral anticoagulation treatment, ST-segment elevation myocardial infarction [MI], cardiogenic shock, dialysis, prior stroke, or thrombocytopenia) were included. Patients were stratified into 2 groups based on whether they fulfilled the TWILIGHT inclusion criteria (high-risk) or not (low-risk). The primary outcome was all-cause death; the key secondary outcomes were MI and major bleeding at 1 year after PCI. RESULTS: Out of 13,136 included patients, 11,018 (83%) were at high risk. At 1-year, these patients had an approximately 3 folds greater hazard of death (1.4% vs 0.4%, HR 3.63, 95% CI 1.70-7.77) and MI (1.8% vs 0.6%, HR 2.81, 95% CI 1.56-5.04) and a nearly 2 folds higher risk of major bleeding (3.3% vs 1.8%, HR 1.86, 95% CI 1.32-2.62) as compared to low-risk patients. CONCLUSION: Among patients not meeting the TWILIGHT exclusion criteria from a large PCI registry, the high-risk inclusion criteria of the TWILIGHT trial were met by the majority of patients and were associated with an increased risk of mortality and MI and a moderately elevated risk of bleeding.


Assuntos
Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária , Humanos , Ticagrelor/uso terapêutico , Inibidores da Agregação Plaquetária/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Seleção de Pacientes , Quimioterapia Combinada , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Sistema de Registros , Resultado do Tratamento
7.
Heart Fail Rev ; 28(2): 465-483, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35900680

RESUMO

Conventional echocardiographic assessment may overestimate the left ventricular (LV) function in mitral regurgitation (MR). LV global longitudinal strain (GLS) is more sensitive marker to detect subclinical LV dysfunction. Multiple studies have investigated the prognostic value of LV-GLS in MR to examine its potential to determine the timing and indication of intervention. This systematic review aimed to assess the prognostic value of LV-GLS in patients with mitral regurgitation (MR) to define its clinical applicability. PUBMED and EMBASE were queried through July 2021 to identify studies investigating the prognostic value of LV-GLS in MR. A total of 24 observational studies with 5267 patients were identified. Sixteen studies investigated for primary MR, 7 studies for secondary MR, and 1 study for both. Most studies included patients who underwent intervention. There was significant heterogeneity in patient population, intervention status, follow-up period, LV-GLS cutoff value, outcomes, and statistical methods among the studies. Meta-analysis was not performed considering the significant variability. With exception to 1 study, all studies demonstrated significant association between impaired LV-GLS and worse clinical and echocardiographic outcomes in primary MR. Prognostic value of LV-GLS in secondary MR was less certain due to inconsistent findings and limited reporting. LV-GLS is a promising parameter of prognostication in primary MR and can be considered as alternative to determine the timing of intervention. However, the optimal cutoff value remains unclear. The prognostic value of LV-GLS in secondary MR is less clear. Further large-scale prospective study is warranted before its routine clinical application.


Assuntos
Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Humanos , Prognóstico , Deformação Longitudinal Global , Estudos Prospectivos , Volume Sistólico , Estudos Retrospectivos , Função Ventricular Esquerda
8.
Catheter Cardiovasc Interv ; 101(3): 511-519, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36691863

RESUMO

BACKGROUND: Patients with chronic kidney disease (CKD) are at higher risk of ischemic and bleeding events after percutaneous coronary intervention (PCI). Complex PCI (CPCI) is associated with higher rates of ischemic complications. Whether CPCI confers an additive risk of adverse events in CKD patients is unclear. METHODS: Patients who underwent PCI at a single tertiary-care-center between 2012 and 2019 were stratified by CKD status and CPCI. The primary outcome was major adverse cardiac events (MACE), a composite of all-cause death, myocardial infarction (MI), and target-vessel revascularization (TVR) at 1-year follow-up. Secondary outcomes included the individual components of the primary outcome and major bleeding. RESULTS: Out of 15,071 patients, 4537 (30.1%) had CKD and 10,534 (69.9%) had no CKD. Patients undergoing CPCI were 1151 (25.4%) and 2983 (28.3%) in the two cohorts, respectively. At one year, CPCI compared with no CPCI was associated with higher risk of MACE in both CKD (Adj. HR 1.72, 95% confidence interval [CI] 1.45-2.06, p < 0.001) and no-CKD patients (Adj. hazard ratios [HR] 2.19, 95% CI 1.91-2.51, p < 0.001; p of interaction 0.057), determined by an excess of death, MI and TVR in CKD patients and of TVR and MI only in no-CKD. CPCI was related with a consistent increase of major bleeding in the CKD (Adj. HR 1.49, 95% CI 1.18-1.87, p < 0.001) and no-CKD group (Adj. HR 1.23, 95% CI 0.98-1.54, p = 0.071, p of interaction 0.206). CONCLUSION: At 1-year follow-up, CPCI was associated with higher risk of MACE and major bleeding irrespective of concomitant CKD. CPCI predicted mortality in CKD patients only.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Insuficiência Renal Crônica , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/epidemiologia , Infarto do Miocárdio/etiologia , Hemorragia/etiologia , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia
9.
J Endovasc Ther ; : 15266028231182226, 2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-37350335

RESUMO

BACKGROUND: Nitinol interwoven bare metal stents represent an advancement in stent technology; however, nominal deployment remains an area of focus. Intravascular ultrasound (IVUS) has been shown to improve outcomes in both the coronary and peripheral vasculature by providing the operator with greater vessel detail; however, the use of adjunctive IVUS with nitinol bare metal stents has not been widely studied. This studies aims to determine the effect of IVUS when used adjunctively with nitinol interwoven bare metal stents in the management of femoropopliteal lesions. DESIGN: Retrospective study. METHODS: This study included a cohort of 200 consecutive patients with peripheral artery disease. All patients were treated with ≥1 Supera bare metal stent, and 91 received adjunctive IVUS imaging prior to stent deployment. Deployment conditions of nominal, compressed, and elongated were measured, and the primary clinical outcomes included target lesion reintervention, amputation, and mortality. This study also showed that 8.3 number needed to treat (NNT) patients must be treated with IVUS to avoid an additional revascularization event. RESULTS: The patients who received IVUS had a significantly greater number of nominally deployed stents (p<0.001). Patients who had IVUS imaging also had significantly lower reintervention rates compared with those who did not receive IVUS imaging (p=0.047). CONCLUSION: The IVUS and angiography decreases clinically-driven target lesion reintervention and increases nominal deployment compared with angiography alone in femoropopliteal lesions treated with interwoven bare metal nitinol stents. CLINICAL IMPACT: Endovascular surgones may conisder the adjuctive use of IVUS when using the Supera stent for the treatment of infra inguinal superficial femoral artery lesions. The adjunct use of IVUS may lead to improved sizing, vessel prep, deployment, and ultiamtely reduction in CD-TLR.

10.
Lancet ; 398(10315): 1974-1983, 2021 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-34793743

RESUMO

BACKGROUND: Contrast-associated acute kidney injury can occur after percutaneous coronary intervention (PCI). Prediction of the contrast-associated acute kidney injury risk is important for a tailored prevention and mitigation strategy. We sought to develop a simple risk score to estimate contrast-associated acute kidney injury risk based on a large contemporary PCI cohort. METHODS: Consecutive patients undergoing PCI at a large tertiary care centre between Jan 1, 2012, and Dec 31, 2020, with available creatinine measurements both before and within 48 h after the procedure, were included; only patients on chronic dialysis were excluded. Patients treated between 2012 and 2017 comprised the derivation cohort and those treated between 2018 and 2020 formed the validation cohort. The primary endpoint was contrast-associated acute kidney injury, defined according to the Acute Kidney Injury Network. Independent predictors of contrast-associated acute kidney injury were derived from multivariate logistic regression analysis. Model 1 included only pre-procedural variables, whereas Model 2 also included procedural variables. A weighted integer score based on the effect estimate of each independent variable was used to calculate the final risk score for each patient. The impact of contrast-associated acute kidney injury on 1-year deaths was also evaluated. FINDINGS: 32 378 PCI procedures were performed and screened for inclusion in the present analysis. After the exclusion of patients without paired creatinine measurements, patients on chronic dialysis, and multiple procedures, 14 616 patients were included in the derivation cohort (mean age 66·2 years, 29·2% female) and 5606 were included in the validation cohort (mean age 67·0 years, 26·4% female). Contrast-associated acute kidney injury occurred in 860 (4·3%) patients. Independent predictors of contrast-associated acute kidney injury included in Model 1 were: clinical presentation, estimated glomerular filtration rate, left ventricular ejection fraction, diabetes, haemoglobin, basal glucose, congestive heart failure, and age. Additional independent predictors in Model 2 were: contrast volume, peri-procedural bleeding, no flow or slow flow post procedure, and complex PCI anatomy. The occurrence of contrast-associated acute kidney injury in the derivation cohort increased gradually from the lowest to the highest of the four risk score groups in both models (2·3% to 34·9% in Model 1, and 2·0% to 38·8% in Model 2). Inclusion of procedural variables in the model only slightly improved the discrimination of the risk score (C-statistic in the derivation cohort: 0·72 for Model 1 and 0·74 for model 2; in the validation cohort: 0·84 for Model 1 and 0·86 for Model 2). The risk of 1-year deaths significantly increased in patients with contrast-associated acute kidney injury (10·2% vs 2·5%; adjusted hazard ratio 1·76, 95% CI 1·31-2·36; p=0·0002), which was mainly due to excess 30-day deaths. INTERPRETATION: A contemporary simple risk score based on readily available variables from patients undergoing PCI can accurately discriminate the risk of contrast-associated acute kidney injury, the occurrence of which is strongly associated with subsequent death. FUNDING: None.


Assuntos
Injúria Renal Aguda/induzido quimicamente , Meios de Contraste/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Medição de Risco/métodos , Injúria Renal Aguda/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Creatinina/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Centros de Atenção Terciária
11.
Am Heart J ; 253: 30-38, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35779584

RESUMO

BACKGROUND: ST-segment elevation myocardial infarction (STEMI) is a high-risk patient medical emergency. We developed a secure mobile application, STEMIcathAID, to optimize care for STEMI patients by providing a digital platform for communication between the STEMI care team members, EKG transmission, cardiac catherization laboratory (cath lab) activation and ambulance tracking. The aim of this report is to describe the implementation of the app into the current STEMI workflow in preparation for a pilot project employing the app for inter-hospital STEMI transfer. APPROACH: App deployment involved key leadership stakeholders from all multidisciplinary teams taking care of STEMI patients. The team developed a transition plan addressing all aspects of the health system improvement process including the workflow analysis and redesign, app installation, personnel training including user account access to the app, and development of a quality assurance program for progress evaluation. The pilot will go live in the Emergency Department (ED) of one of the hospitals within the Mount Sinai Hospital System (MSHS) during the daytime weekday hours at the beginning and extending to 24/7 schedule over 4-6 weeks. For the duration of the pilot, ED personnel will combine the STEMIcathAID app activation with previous established STEMI activation processes through the MSHS Clinical Command Center (CCC) to ensure efficient and reliable response to a STEMI alert. More than 250 people were provisioned app accounts including ED Physicians and frontline nurses, and trained on their user-specific roles and responsibilities and scheduled in the app. The team will be provided with a feedback form that is discipline specific to complete after every STEMI case in order to collect information on user experience with the STEMIcathAID app functionality. The form will also provide quantitative metrics for the key time sensitive steps in STEMI care. CONCLUSIONS: We developed a uniform approach for deployment of a mobile application for STEMI activation and transfer in a large urban healthcare system to optimize the clinical workflow in STEMI care. The results of the pilot will demonstrate whether the app has a significant impact on the quality of care for transfer of STEMI patients.


Assuntos
Aplicativos Móveis , Infarto do Miocárdio , Infarto do Miocárdio com Supradesnível do Segmento ST , Atenção à Saúde , Humanos , Projetos Piloto , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Fluxo de Trabalho
12.
Catheter Cardiovasc Interv ; 99(6): 1935-1944, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35312218

RESUMO

OBJECTIVES: To compare outcomes in Sapien 3 Ultra (S3U) transcatheter aortic valve replacement (TAVR) with extreme annular undersizing (EAU) versus nominal annular sizing (NAS). BACKGROUND: The Edwards S3U valve has reduced paravalvular leak (PVL) in TAVR but outcomes remain unknown in extremely undersized anatomy. Implanting a smaller S3U valve may facilitate future redo-TAVR but risk compromising hemodynamics. METHODS: From December 2019 to July 2021, 366 patients with native aortic stenosis underwent S3U TAVR. Patients with EAU (annular areas >430 mm2 for 23 mm or >546 mm2 for 26 mm) were compared to NAS (338-430 mm2 for 23 mm or 430-546 mm2 for 26 mm). In-hospital and 30-day outcomes, and redo-TAVR feasibility were determined. RESULTS: There were 79 (21.6%) EAU patients, with more bicuspid (p = 0.0014) and ≥moderate annular/left ventricular outflow tract calcification (p < 0.001). The EAU group had less annular oversizing than NAS group (23 mm: -8.2 ± 2.6% vs. 4.0 ± 7.0%, p < 0.001; 26 mm: -8.9 ± 2.2% vs. 6.7 ± 6.9%, p < 0.001), more balloon overfilling (71.3% vs. 11.6%, p < 0.001), and postdilatation (15.0% vs. 5.8%, p = 0.016). No differences were found in in-hospital or 30-day mortality and stroke (p > 0.05). Mild PVL (13.4% EAU vs. 11.5% NAS, p = 0.56) and mean gradients (23 mm: 13.0 ± 4.5 vs. 14.1 ± 5.4 mmHg, p = 0.40; 26 mm: 11.4 ± 4.1 vs. 11.5 ± 3.9 mmHg, p = 1.0) were similar at 30 days. Had the EAU group undergone NAS with the larger Sapien 3/S3U, by computed tomography analysis simulating 80:20 or 90:10 target implant depth, 33.3%-60.9% (vs. 4.3%-23.2%) would not be feasible for redo-TAVR due to high risk of coronary obstruction. CONCLUSIONS: In this first report of EAU with S3U TAVR, similar excellent short-term outcomes can be achieved compared to NAS, and may preserve future redo-TAVR option.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Humanos , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 99(3): 924-931, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34626449

RESUMO

OBJECTIVES: We assessed the impact of conventional delivery system (DS) insertion technique on "Hat-marker" orientation/commissural alignment in patients who underwent transcatheter aortic valve replacement (TAVR) in the Evolut Low Risk Trial CT substudy versus a modified technique. BACKGROUND: Unlike surgical aortic valve replacement, where alignment of the surgical valve commissures with native commissures can be achieved virtually 100% of the time, commissural alignment during TAVR is not achieved consistently. This may subsequently impact the feasibility of both coronary access and reintervention after TAVR. METHODS: "Hat-marker" orientations during deployment were characterized as outer curve (OC), center front (CF), inner curve, and center back. Severe commissure-to-CA overlap was 0-20°. "Hat-marker" orientations and CA overlap were compared to 240 patients from a single center using the modified 3-o'clock flush port DS technique. RESULTS: In the CT substudy in which conventional DS insertion was performed (flush port at 12 o'clock); 154/249 had both analyzable CT and procedural fluoroscopy to validate "Hat-marker" to C-tab/commissural orientation. On post-TAVR CT, Evolut valve commissural orientation and coronary artery (CA) ostia were identified. Compared to conventional DS technique in the CT substudy, the modified technique had higher rates of "Hat-marker" at OC/CF orientation, improved commissural alignment and reduced severe CA overlap; (left main, 14.2 vs. 27.9%; right coronary artery, 11.7 vs. 27.3% both, 5.0 vs. 13.6%; 1 or both CA, 20.8 vs. 41.6%, all p < 0.01). CONCLUSIONS: The modified technique improved initial "Hat-marker" orientation during Evolut deployment and resulted in better commissural alignment and reduced CA overlap.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
Catheter Cardiovasc Interv ; 100(4): 636-645, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36040717

RESUMO

BACKGROUND: Midterm data comparing clinical outcomes after successful implantation of self-expanding and balloon-expandable transcatheter heart valves (THV) are limited. We aimed to compare 2-year outcomes after successful transcatheter aortic valve implantation (TAVI) with the Edwards balloon-expandable or the Medtronic self-expanding THV. METHODS: Two-year outcomes were analyzed according to the implanted THV in the GALILEO trial. Major adverse cardiac and cerebrovascular events (MACCE) was a composite of all-cause death or thromboembolic events including stroke, myocardial infarction, symptomatic valve thrombosis, systemic embolism, deep-vein thrombosis, or pulmonary embolism. RESULTS: Among 1644 patients recruited in 136 centers across 16 countries between 2015 and 2018, 499 received a self-expanding and 757 patients received a balloon-expandable THV. Patients treated with a self-expanding THV were more likely to be female, and had higher surgical risk, lower hemoglobin levels, and more frequent valve-in-valve procedures than those with a balloon-expandable THV. After multivariable adjustment, there were no significant differences in major clinical outcomes between self-expanding versus balloon-expandable THV: MACCE (17.0% vs. 13.4%, adjusted-hazard ratios [HR] 1.18, 95% confidence intervals [CI]: 0.82-1.69); all-cause death (11.4% vs. 9.3%, adjusted-HR 1.26; 95% CI: 0.78-2.05); cardiovascular death (8.5% vs. 4.0%, adjusted-HR 1.53; 95% CI: 0.82-2.86), any stroke (5.1% vs. 3.7%, adjusted-HR 0.86; 95% CI: 0.43-1.73); major or life-threatening bleeding (5.9% vs. 6.8%, adjusted-HR 0.93; 95% CI: 0.53-1.63). CLINICAL TRIAL REGISTRATION: https://www. CLINICALTRIALS: gov. NCT02556203. CONCLUSIONS: Two-year follow-up data from the GALILEO trial indicate that successful TAVI either with self-expanding or balloon-expandable THVs according to physician discretion did not show difference in rates of MACCE.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Hemoglobinas , Humanos , Masculino , Desenho de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
15.
J Thromb Thrombolysis ; 53(1): 20-29, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34347202

RESUMO

Patients undergoing percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI) are at increased risk for thrombotic and bleeding complications compared to patients with chronic coronary syndrome (CCS). The academic research consortium (ARC) recently suggested a set of criteria to identify patients at high bleeding risk (HBR). We sought to evaluate the performance of the ARC-HBR criteria among patients undergoing PCI according to clinical presentation. We included all consecutive patients undergoing PCI at a tertiary-care center. Patients were deemed at HBR if they fulfilled ≥ 1 major or ≥ 2 minor ARC-HBR criteria. The primary bleeding endpoint was a composite of in-hospital or post-discharge bleeding at 1-year follow-up. Secondary outcomes included all-cause death and myocardial infarction. Out of 6068 patients, 1391 (22.9 %) presented with AMI and were more often at HBR than those with CCS (46.9 % vs. 43.0 %, p = 0.01). HBR patients had a higher risk for the primary bleeding endpoint than non-HBR, irrespective of the clinical indication for PCI (AMI: 19.5 % vs. 5.5 %; HR 3.86, 95 % CI 2.63-5.69; CCS: 6.8 % vs. 2.6 %; HR 2.65, 95 % CI 1.92-3.68; p-interaction = 0.11). Secondary outcomes followed a similar trend. After multivariable adjustment, AMI presentation remained significantly associated with increased risk for bleeding at 1 year (HR 1.64, 95 % CI 1.13-2.38, p = 0.01). The ARC-HBR criterion associated with the highest bleeding risk was severe/end-stage chronic kidney disease in AMI and moderate/severe anemia in CCS. The ARC-HBR framework successfully identified AMI and CCS patients with increased risk for bleeding complications at 1 year post-PCI. Figure prepared with BioRender.


Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Assistência ao Convalescente , Humanos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/cirurgia , Alta do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Fatores de Risco , Resultado do Tratamento
16.
J Thromb Thrombolysis ; 53(2): 380-389, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34386899

RESUMO

Perioperative cardiovascular complications are important causes of morbidity and mortality associated with non-cardiac surgery, especially in patients with recent percutaneous coronary intervention (PCI). We aimed to illustrate the types and timing of different surgeries occurring after PCI, and to evaluate the risk of thrombotic and bleeding events according to the perioperative antiplatelet management. Patients undergoing urgent or elective non-cardiac surgery within 1 year of PCI at a tertiary-care center between 2011 and 2018 were included. The primary outcome was major adverse cardiac events (MACE; composite of death, myocardial infarction, or stent thrombosis) at 30 days. Perioperative bleeding was defined as ≥ 2 units of blood transfusion. A total of 1092 surgeries corresponding to 747 patients were classified by surgical risk (low: 50.9%, intermediate: 38.4%, high: 10.7%) and priority (elective: 88.5%, urgent/emergent: 11.5%). High-risk and urgent/emergent surgeries tended to occur earlier post-PCI compared to low-risk and elective ones, and were associated with an increased risk of both MACE and bleeding. Preoperative interruption of antiplatelet therapy (of any kind) occurred in 44.6% of all NCS and was more likely for procedures occurring later post-PCI and at intermediate risk. There was no significant association between interruption of antiplatelet therapy and adverse cardiac events. Among patients undergoing NCS within 1 year of PCI, perioperative ischemic and bleeding events primarily depend on the estimated surgical risk and urgency of the procedure, which are increased early after PCI. Preoperative antiplatelet interruption was not associated with an increased risk of cardiac events.


Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Procedimentos Cirúrgicos Eletivos/efeitos adversos , Hemorragia/induzido quimicamente , Humanos , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Inibidores da Agregação Plaquetária/efeitos adversos , Resultado do Tratamento
17.
Catheter Cardiovasc Interv ; 97(7): 1407-1416, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32776696

RESUMO

Calcified coronary artery bifurcation lesions (CBL) remain a challenge for the interventional cardiologist. Evidence regarding treatment of CBL is minimal. Optimal plaque modification is the most important step prior to stent deployment. Provisional stenting is the preferred strategy for most bifurcation lesions. However, two-stent strategy should be considered for BL with compromised large SB (>2.5 mm) supplying a large territory, >70% SB stenosis and lesions more than 5 mm long. In this contemporary review article, we present a simplified approach to treating CBL and demonstrate the approach to specific case examples using our newly developed mobile application, BifurcAID.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Intervenção Coronária Percutânea , Placa Aterosclerótica , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Stents , Resultado do Tratamento
18.
Catheter Cardiovasc Interv ; 97(3): E280-E287, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32558218

RESUMO

OBJECTIVES: We evaluated the procedural and 1-year clinical outcomes of orbital atherectomy (OA) for treatment of coronary in-stent restenosis (ISR). BACKGROUND: The optimal treatment for ISR remains uncertain. While rotational and laser atherectomy have been used as neointimal debulking techniques for ISR, there have been few reports on OA for ISR. METHODS: This is a retrospective observational study of consecutive patients who underwent percutaneous coronary intervention (PCI) for ISR with OA in Mount Sinai catheterization laboratory between November 2013 and January 2018. Procedural success was defined as angiographic success without in-hospital major adverse cardiac events (MACE; the composite of all-cause death, myocardial infarction [MI], or target vessel revascularization). Clinical outcomes were assessed at 1 month and 12 months postprocedure. RESULTS: A total of 87 patients were included in the study. All 87 patients were treated with OA, after which 49 (56.3%) patients also received new drug-eluting stents. Angiographic success was achieved in 87 (100%) patients and procedural success was achieved in 79 (90.8%) patients. In-hospital MACE occurred in 8 (9.2%) patients, all due to periprocedural non-Q-wave MI. Acute lumen gain was 1.19 ± 0.57 mm after OA plus balloon angioplasty and 1.75 ± 0.50 mm after stent placement. MACE within 1 year occurred in 17 (19.5%) patients. CONCLUSIONS: OA for ISR was performed with favorable procedural and 1-year clinical outcomes. Randomized trials are warranted to determine whether OA improves the poor prognosis of patients with ISR treated without debulking.


Assuntos
Aterectomia Coronária , Reestenose Coronária , Intervenção Coronária Percutânea , Aterectomia , Aterectomia Coronária/efeitos adversos , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , Stents , Resultado do Tratamento
19.
Catheter Cardiovasc Interv ; 97(7): 1341-1351, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32478459

RESUMO

OBJECTIVES: We aimed to evaluate the 1-year outcomes of three everolimus-eluting stents (EES) for complex percutaneous coronary intervention (PCI). BACKGROUND: It is controversial whether contemporary bioresorbable-polymer drug-eluting stents (BP-DES) are associated with better outcomes compared with durable-polymer DES (DP-DES). METHODS: Patients undergoing PCI with cobalt-chromium (CoCr)-DP-EES (Xience), platinum-chromium (PtCr)-DP-EES (Promus), or PtCr-BP-EES (Synergy) at one high-volume institution between 2015 and 2017 were included. The primary endpoint was 1-year major adverse cardiac events (MACE), a composite of death, myocardial infarction, and target-vessel revascularization. Associations were also examined in patients undergoing complex PCI. Multivariable analysis was conducted to adjust for baseline differences across groups. RESULTS: We included n = 5,446 patients (CoCr-DP-EES, n = 3,177; PtCr-DP-EES, n = 1,555; PtCr-BP-EES, n = 714). Patients treated with PtCr-BP-EES had higher comorbidity burden and procedural complexity. At 1 year, MACE rates were 8.9% for CoCr-DP-EES versus 8.9% for PtCr-DP-EES versus 8.6% for PtCr-BP-EES (p = .97). The incidence of definite/probable stent thrombosis (ST) was also similar (0.6 vs. 0.4 vs. 0.3%, p = .69). Complex PCI was performed in n = 2,894/5,446 (53.1%). At 1 year, MACE rates were 11.5 versus 10.7 versus 10.3%, respectively (p = .83). The incidence of definite/probable ST was also similar (0.9 vs. 0.3 vs. 0.3%, p = .22). On multivariable analysis, stent type was not an independent predictor of MACE either in the overall or in the complex PCI population. CONCLUSIONS: We observed comparable 1-year rates of MACE and definite/probable ST in patients undergoing PCI with CoCr-DP-EES, PtCr-DP-EES, and PtCr-BP-EES. Results were unchanged among patients undergoing complex PCI. Future multicenter randomized studies should confirm and extend our findings.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Everolimo/efeitos adversos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Resultado do Tratamento
20.
Catheter Cardiovasc Interv ; 98(4): 658-668, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33034419

RESUMO

OBJECTIVES: We examined the incidence of side branch (SB) compromise after provisional stenting of calcified bifurcation lesions treated with rotational atherectomy (RA) or cutting balloon angioplasty (CBA) and the utility of optical coherence tomography (OCT) to detect functionally significant SB stenoses. BACKGROUND: The comparative impact of RA versus CBA on SB compromise and functional significance remains poorly characterized. METHODS: Seventy-one consecutive patients with 71 calcified bifurcation lesions with angiographically intermediate SB stenoses were randomized to RA (n = 35) or CBA (n = 36). The primary endpoint was SB compromise defined as SB diameter stenosis ≥70%, SB dissection or thrombolysis in myocardial infarction flow grade < 3 after provisional stenting. Secondary endpoints included SB FFR in noncompromised SBs and its correlation with SB ostium area (SBOA) assessed by three-dimensional OCT. RESULTS: SB compromise after provisional stenting was observed in 7 (20.0%) lesions that underwent RA and in 9 (25.0%) lesions treated with CBA (p = .62). Mean SB FFR was 0.83 ± 0.08 and was similar between the study arms. Functionally significant SB stenosis (FFR ≤ 0.80) was detected in 17(30.9%) angiographically noncompromised SBs. SBOA after stenting was an independent predictor of FFR ≤ 0.80 (OR 0.002, 95% CI: 0.00-0.15, p = .002). The optimal cutoff value for SBOA to predict functionally significant SB stenosis was 0.76 mm2 (sensitivity 82%, specificity 89% and area under the curve 0.92, 95% CI: 0.84-0.99). CONCLUSIONS: The rates of SB compromise and functionally significant stenosis after provisional stenting of calcified bifurcation lesions were similar between two lesion preparation strategies. OCT SBOA can detect SB branches with FFR ≤ 0.80 with high sensitivity and specificity.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA