Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Stroke ; 54(4): 947-954, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36866671

RESUMO

BACKGROUND: Percutaneous endocardial left atrial appendage occlusion (LAAO) is an alternative therapy for stroke prevention in patients with atrial fibrillation who are poor candidates for oral anticoagulants. Oral anticoagulation is generally discontinued 45 days following successful LAAO. Real-world data on early stroke and mortality following LAAO are lacking. METHODS: Using International Classification of Diseases, Tenth Revision, Clinical-Modification codes, we performed a retrospective observational registry analysis to examine the rates and predictors of stroke, mortality, and procedural complications during index hospitalization and 90-day readmission among 42 114 admissions in the Nationwide Readmissions Database for LAAO between 2016 and 2019. Early stroke and mortality were defined as events occurring during index admission or 90-day readmission. Data on timing of early strokes post-LAAO were collected. Multivariable logistic regression modeling was used to ascertain predictors of early stroke and major adverse events. RESULTS: LAAO was associated with low rates of early stroke (0.63%), early mortality (0.53%), and procedural complications (2.59%). Among patients who had readmissions with strokes after LAAO, the median time from implant to readmission was 35 days (interquartile range, 9-57 days); 67% of readmissions with strokes occurred <45 days postimplant. Between 2016 and 2019, the rates of early stroke after LAAO significantly decreased (0.64% versus 0.46% P-for-trend <0.001), while early mortality and major adverse event rates were unchanged. Peripheral vascular disease and a history of prior stroke were independently associated with early stroke after LAAO. Early post-LAAO stroke rates were similar between low, medium, and high LAAO volume tertile centers. CONCLUSIONS: In this contemporary real-world analysis, the early stroke rate after LAAO was low, with the majority occurring within 45 days of device implantation. Despite an increase in LAAO procedures between 2016 and 2019, there with a significant decline in early strokes after LAAO during that period.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Anticoagulantes , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/complicações , Resultado do Tratamento
2.
J Am Coll Cardiol ; 81(17): 1714-1725, 2023 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-37100488

RESUMO

BACKGROUND: Cardiac implantable electronic device (CIED)-associated infections are associated with substantial morbidity, mortality, and costs. Guidelines have cited endocarditis as a Class I indication for transvenous lead removal/extraction (TLE) among patients with CIEDs. OBJECTIVES: The authors sought to study utilization of TLE among hospital admissions with infective endocarditis using a nationally representative database. METHODS: Using the Nationwide Readmissions Database (NRD), 25,303 admissions for patients with CIEDs and endocarditis between 2016 and 2019 were evaluated on the basis of International Classification of Diseases-10th Revision, Clinical-Modification (ICD-10-CM) codes. RESULTS: Among admissions for patients with CIEDs and endocarditis, 11.5% were managed with TLE. The proportion undergoing TLE increased significantly from 2016 to 2019 (7.6% vs 14.9%; P trend < 0.001). Procedural complications were identified in 2.7%. Index mortality was significantly lower among patients managed with TLE (6.0% vs 9.5%; P < 0.001). Presence of Staphylococcus aureus infection, implantable cardioverter-defibrillator, and large hospital size were independently associated with TLE management. TLE management was less likely with older age, female sex, dementia, and kidney disease. After adjustment for comorbidities, TLE was independently associated with significantly lower odds of mortality (adjusted OR: 0.47; 95% CI: 0.37-0.60 by multivariable logistic regression, and adjusted OR: 0.51; 95% CI: 0.40-0.66 by propensity score matching). CONCLUSIONS: Utilization of lead extraction among patients with CIEDs and endocarditis is low, even in the presence of low rates of procedural complications. Lead extraction management is associated with significantly lower mortality, and its use has trended upward between 2016 and 2019. Barriers to TLE for patients with CIEDs and endocarditis require investigation.


Assuntos
Desfibriladores Implantáveis , Endocardite Bacteriana , Endocardite , Cardiopatias , Marca-Passo Artificial , Humanos , Feminino , Remoção de Dispositivo/efeitos adversos , Endocardite/epidemiologia , Endocardite/cirurgia , Endocardite/etiologia , Desfibriladores Implantáveis/efeitos adversos , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/cirurgia , Endocardite Bacteriana/complicações , Cardiopatias/complicações , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos
3.
Heart Rhythm ; 17(5 Pt A): 721-727, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31978595

RESUMO

BACKGROUND: Increased peak luminal esophageal temperature (LET) is associated with increased risk of esophageal injury after left atrial posterior wall (LAPW) ablation. The magnitude, distribution, and risk factors of LET increase with high-power short-duration (HPSD) LAPW ablation are not well understood. OBJECTIVE: The purpose of this study was to describe the spatial and temporal characteristics of LET changes associated with HPSD LAPW radiofrequency (RF) ablation. METHODS: LET was sampled at 20 Hz using a 12-point esophageal temperature monitor (CIRCA S-CATH; Circa Scientific, Inc) in 16 patients undergoing LAPW ablation. Esophageal temperature sensor position and lesion locations were recorded using an electroanatomic mapping system with fluoroscopic integration (CARTO 3, CARTOUNIVU; Biosense Webster, Inc). Point-by-point LAPW ablation was performed at 50 W for 6 seconds. The first 20 LAPW lesions were individually analyzed in each patient. RESULTS: LET increase ≥4°C (8 lesions: max LET 5.8°C), 2°-4°C (34 lesions), and 1°-2°C (58 lesions) occurred at 9 ± 2 mm, 8 ± 2 mm, and 13 ± 2 mm from sensors, respectively. Lesions placed >20 mm from a temperature sensor did not result in an LET increase ≥2°C. Temperature resolution to within 1°C of baseline occurred ∼60 seconds after cessation of RF application. Consecutive lesions resulting in additive heating of at least 1°C occurred in 17 lesion pairs with an interlesion distance of 9 ± 4 mm and interlesion time of 21 ± 4 seconds. CONCLUSION: HPSD LAPW ablation can result in severe esophageal temperature increases. Significant LET increase will be undetected when lesions are >20 mm away from a temperature sensor. Additive LET increase was observed with consecutive lesions placed <20 mm apart within 60 seconds.


Assuntos
Fibrilação Atrial/cirurgia , Temperatura Corporal/fisiologia , Esôfago/fisiopatologia , Monitorização Intraoperatória/métodos , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA