1.
Endosc Int Open ; 12(5): E666-E675, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38707594

RESUMO

Background and study aims To develop a pancreatobiliary endoscopic guidewire with good clinical performance, an understanding of its structure is necessary. This study aimed to investigate the structural factors influencing the clinical performance of pancreatobiliary endoscopic guidewires. Methods Eight types of 0.025-inch guidewires were evaluated. The following structural properties were measured: tip length, tip deflection height, tip weight (TW), ratio of tip core weight to TW, shaft coating type (flat or uneven), outer diameter, and core wire diameter (CWD). Four performance tests were conducted to evaluate shaft stiffness as bending force (BF), shaft lubricity as friction force (FF), torque response as torque response rate (TRR), and seeking ability as total insertion success (TIS) in a technical test using a 3D bile duct model. The correlation coefficients of each variable were analyzed. Results The BF and CWDs were strongly correlated, as well as the FF and CWDs and BF. Among the guidewires with similar CWDs, the guidewires with uneven coating had significantly lower FF than those with flat coating. The TRR was strongly correlated with the CWDs; furthermore, guidewires with lower FF had better TRR. TIS was strongly correlated with the TRR, TWs, and ratio of the tip core weight to TW. Conclusions CWD affects shaft stiffness; CWD and coating type affect shaft lubricity and torque response. Because TRR and TW are correlated with seeking ability, an appropriate combination of core wire thickness, TW, and coating design is required to develop a guidewire with good seeking ability.

2.
Artigo em Inglês | MEDLINE | ID: mdl-39075945

RESUMO

BACKGROUND: Self-expandable metal stent (SEMS) migration after endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is a severe complication. The migration risk could be related to the surface friction of SEMS, assumed to be affected by the wire structure and mechanical properties, including radial force (RF); however, their relevance remains unclear. This experimental study aimed to assess the mechanical properties of SEMS involved in the onset of stent migration by measuring the sliding-resistance force (SF) as the SEMS moves through the stomach wall. METHODS: The SF of seven types of 8-mm diameter SEMS (four braided and three laser-cut types) and porcine stomach wall was measured with a universal testing machine. The SF of each SEMS was measured three times, and the average maximum SF (SFmax) was used for analysis. The correlation between SFmax and RF of each SEMS was evaluated. RESULTS: SFmax and RF showed a very strong positive correlation (r = 0.92). Compared to the regression line predictions in the scatter plots of SFmax and RF, the SFmax of laser-cut and braided type SEMSs had positive and negative residuals, respectively. CONCLUSIONS: Selecting a laser-cut type SEMS with a higher RF may more effectively prevent the onset of stent migration against the stomach wall in EUS-HGS.

3.
J Gen Fam Med ; 23(5): 356-357, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36093224

RESUMO

A 66-year-old Japanese woman presented with upper abdominal pain and nausea after having eaten several rice cakes. An abdominal CT scan showed retained rice cakes in the stomach, which led to intestinal obstruction three days later.