Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Arch Toxicol ; 98(1): 347-361, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37906319

RESUMO

The acyclic linear monoterpenes Linalool (Lin) and Linalyl acetate (LinAc) occur in nature as major constituents of various essential oils such as lavender oils. A potential endocrine activity of these compounds was discussed in literature including premature thelarche and prepubertal gynecomastia due to lavender product use. This study aims to follow-up on these critical findings reported by testing Lin and LinAc in several studies in line with current guidance and regulatory framework. No relevant anti-/ER and AR-mediated activity was observed in recombinant yeast cell-based screening tests and guideline reporter gene in vitro assays in mammalian cells. Findings in the screening test suggested an anti-androgenic activity, which could not be confirmed in the respective mammalian cell guideline assay. Mechanistic guideline in vivo studies (Uterotrophic and Hershberger assays) with Lin did not show significant dose related changes in estrogen or androgen sensitive organ weights and a guideline reproductive toxicity screening study did not reveal evident effects on sex steroid hormone sensitive organ weights, associated histopathological findings and altered sperm parameters. Estrous cycling and mating/fertility indices were not affected and no evident Lin-related steroid hormone dependent effects were found in the offspring. Overall, the initial concerns from literature were not confirmed. Findings in the yeast screening test were aberrant from follow-up guideline in vitro and in vivo studies, which underlines the need to apply careful interpretation of single in vitro test results to support a respective line of evidence and to establish a biologically plausible link to an adverse outcome.


Assuntos
Androgênios , Óleos Voláteis , Animais , Masculino , Alérgenos , Estrona , Mamíferos , Monoterpenos/farmacologia , Monoterpenos/toxicidade , Óleos Voláteis/farmacologia , Óleos Voláteis/toxicidade , Óleos de Plantas , Saccharomyces cerevisiae , Sementes
2.
Arch Toxicol ; 98(7): 2047-2063, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38689008

RESUMO

The ongoing transition from chemical hazard and risk assessment based on animal studies to assessment relying mostly on non-animal data, requires a multitude of novel experimental methods, and this means that guidance on the validation and standardisation of test methods intended for international applicability and acceptance, needs to be updated. These so-called new approach methodologies (NAMs) must be applicable to the chemical regulatory domain and provide reliable data which are relevant to hazard and risk assessment. Confidence in and use of NAMs will depend on their reliability and relevance, and both are thoroughly assessed by validation. Validation is, however, a time- and resource-demanding process. As updates on validation guidance are conducted, the valuable components must be kept: Reliable data are and will remain fundamental. In 2016, the scientific community was made aware of the general crisis in scientific reproducibility-validated methods must not fall into this. In this commentary, we emphasize the central importance of ring trials in the validation of experimental methods. Ring trials are sometimes considered to be a major hold-up with little value added to the validation. Here, we clarify that ring trials are indispensable to demonstrate the robustness and reproducibility of a new method. Further, that methods do fail in method transfer and ring trials due to different stumbling blocks, but these provide learnings to ensure the robustness of new methods. At the same time, we identify what it would take to perform ring trials more efficiently, and how ring trials fit into the much-needed update to the guidance on the validation of NAMs.


Assuntos
Toxicologia , Reprodutibilidade dos Testes , Medição de Risco/métodos , Animais , Toxicologia/métodos , Toxicologia/normas , Testes de Toxicidade/métodos , Humanos , Estudos de Validação como Assunto , Projetos de Pesquisa/normas , Alternativas aos Testes com Animais/métodos
3.
Regul Toxicol Pharmacol ; 146: 105543, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38081574

RESUMO

Multiple in vitro eye irritation methods have been developed and adopted as OECD health effects test guidelines. However, for predicting the ocular irritation/damage potential of agrochemical formulations there is an applicability domain knowledge gap for most of the methods. To overcome this gap, a retrospective evaluation of 192 agrochemical formulations with in vivo (OECD TG 405) and in vitro (OECD TG 437, 438, and/or 492) data was conducted to determine if the in vitro methods could accurately assign United Nations Globally Harmonized System for Classification and Labelling of Chemicals (GHS) eye irritation hazard classifications. In addition, for each formulation the eye irritation classification was derived from the classification of the contained hazardous ingredients and their respective concentration in the product using the GHS concentration threshold (CT) approach. The results herein suggest that the three in vitro methods and the GHS CT approach were highly predictive of formulations that would not require GHS classification for eye irritation. Given most agrochemical formulations fall into this category, methods that accurately identify non-classified agrochemical formulations could significantly reduce the use of animals for this endpoint.


Assuntos
Agroquímicos , Irritantes , Animais , Agroquímicos/toxicidade , Agroquímicos/química , Estudos Retrospectivos , Alternativas aos Testes com Animais , Olho
4.
Regul Toxicol Pharmacol ; 138: 105330, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36599391

RESUMO

Over the last decade, research into methodologies to identify skin sensitization hazards has led to the adoption of several non-animal methods as OECD test guidelines. However, predictive accuracy beyond the chemical domains of the individual validation studies remains largely untested. In the present study, skin sensitization test results from in vitro and in chemico methods for 12 plant extracts and 15 polymeric materials are reported and compared to available in vivo skin sensitization data. Eight plant extracts were tested in the DPRA and h-CLAT, with the 2 out of 3 approach resulting in a balanced accuracy of 50%. The balanced accuracy for the 11 plant extracts assessed in the SENS-IS was 88%. Excluding 5 polymers inconclusive in vitro, the remainder, assessed using the 2 out of 3 approach, resulted in 63% balanced accuracy. The SENS-IS method, excluding one polymeric material due to technical inapplicability, showed 68% balanced accuracy. Although based on limited numbers, the results presented here indicate that some substance subgroups may not be in the applicability domains of the method used and careful analysis is required before positive or negative results can be accepted.


Assuntos
Dermatite Alérgica de Contato , Animais , Alternativas aos Testes com Animais/métodos , Polímeros/toxicidade , Pele
5.
Risk Anal ; 42(2): 224-238, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33300210

RESUMO

For hazard classifications of chemicals, continuous data from animal- or nonanimal testing methods are often dichotomized into binary positive/negative outcomes by defining classification thresholds (CT). Experimental data are, however, subject to biological and technical variability. Each test method's precision is limited resulting in uncertainty of the positive/negative outcome if the experimental result is close to the CT. Borderline ranges (BR) around the CT were suggested, which represent ranges in which the study result is ambiguous, that is, positive or negative results are equally likely. The BR reflects a method's precision uncertainty. This article explores and compares different approaches to quantify the BR. Besides using the pooled standard deviation, we determine the BR by means of the median absolute deviation (MAD), with a sequential combination of both methods, and by using nonparametric bootstrapping. Furthermore, we quantify the BR for different hazardous effects, including nonanimal tests for skin corrosion, eye irritation, skin irritation, and skin sensitization as well as for an animal test on skin sensitization (the local lymph node assay, LLNA). Additionally, for one method (direct peptide reactivity assay) the BR was determined experimentally and compared to calculated BRs. Our results demonstrate that (i) the precision of the methods is determining the size of their BRs, (ii) there is no "perfect" method to derive a BR, alas, (iii) a consensus on BR is needed to account for the limited precision of testing methods.


Assuntos
Alternativas aos Testes com Animais , Ensaio Local de Linfonodo , Alternativas aos Testes com Animais/métodos , Animais , Pele , Incerteza
6.
Handb Exp Pharmacol ; 265: 3-27, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33136188

RESUMO

In regulatory toxicology, in vivo studies are still prevailing, and human-derived in vitro models are mostly used in testing for local toxicity to the skin and the eyes. A single in vitro model may be limited to address one or few molecular or cellular events leading to adverse outcomes. Hence, in many instances their regulatory use involves the combination of several in vitro models to assess the hazard potential of test substance. A so-called defined approach combines different testing methods and a 'data interpretation procedure' to obtain a comprehensive overall assessment which is used for the regulatory hazard classification of the test substance.Validation is a prerequisite of regulatory acceptance of new testing methods: This chapter provides an overview of the method development from an experimental method to a test guideline via application of GIVIMP (good in vitro method practice), standardization, validation to the regulatory adoption as an OECD test guidelines. Quandaries associated with the validation towards reference data from in vivo animal studies with limited accuracy and limited human relevance are discussed, as well as uncertainty and limitations arising from restricted applicability and technical and biological variance of the in vitro methods.This chapter provides an overview of human-derived in vitro models currently adopted as OECD test guidelines: From the first skin corrosion tests utilizing reconstructed human epidermis models (RhE), to models to test for skin irritation, phototoxicity, eye irritation, and skin sensitization. The latter is using a battery of different methods and defined approaches which are still under discussion for their regulatory adoption. They will be a vanguard of future applications of human-derived models in regulatory toxicology. RhEs for testing of genotoxicity and of dermal penetration and absorption, have been developed, underwent validation studies and may soon be adopted for regulatory use; these are included in this chapter.


Assuntos
Alternativas aos Testes com Animais , Testes de Irritação da Pele , Animais , Humanos , Irritantes/farmacologia , Pele , Testes de Toxicidade
7.
Regul Toxicol Pharmacol ; 115: 104713, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32562760

RESUMO

While single non-animal methods have been adopted in OECD test guidelines, combinations of methods (so called defined approaches, DA) are not. Hardly any animal study can be replaced by a single non-animal method, rather DA are needed. The OECD published the Adverse Outcome Pathway (AOP) on skin sensitization in 2012 and is currently discussing the implementation of DA into a guideline. Obviously, it takes thorough considerations and evaluations to validate such DA. Currently we see four preconditions for a proper and expedient implementation of DA in a guideline: (i) The reference data should be selected to allow meaningful evaluations and must not replicate the limitations of the murine local lymph node assay (LLNA) (ii) Methods and prediction models should be validated before they are used in an OECD-adopted DA, (iii) An OECD-adopted DA should follow the respective AOP and (iv) acknowledge regulatory needs and successful toxicological practice. These points still need to be considered in the current discussion at the OECD. A guideline for skin sensitization DA is setting the scene for regulatory acceptance of all new approaches (for any toxicological endpoint) in the future. In this commentary, we are expounding these preconditions to allow a scientifically valid and sustainable application of modern (no-animal) approaches in regulatory toxicology.


Assuntos
Rotas de Resultados Adversos , Dermatite Alérgica de Contato , Testes de Irritação da Pele , Alternativas aos Testes com Animais , Guias como Assunto , Humanos , Organização para a Cooperação e Desenvolvimento Econômico
9.
Regul Toxicol Pharmacol ; 106: 352-368, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31112722

RESUMO

There has been significant progress in recent years in the development and application of alternative methods for assessing the skin sensitization potential of chemicals. The pathways involved in skin sensitization have been described in an OECD adverse outcome pathway (AOP). To date, a single non-animal test method is not sufficient to address this AOP so numerous approaches involving the use of 2 or more assays are being evaluated for their performance. The 2 out of 3 approach is a simple approach that has demonstrated very good sensitivity, specificity and overall accuracy numbers for predicting the skin sensitization potential of chemicals. Chemicals with at least two positive results in tests addressing Key events 1-3 are predicted sensitizers, while chemicals with none or only one positive outcome are predicted non-sensitizers. In this report we have thoroughly reviewed the discordant results of 29 chemicals with 1 out of 3 positive results to understand better what led to the results observed and how this information might impact our hazard assessments of these chemicals. We initially categorized each chemical using a weight of evidence approach as positive, negative or indeterminate based on review of available human and animal data as well as what skin sensitization alerts were triggered using two versions of OECD Toolbox and DEREK Nexus. We determined that 4 of the 29 chemicals should be classified as indeterminate and not included in analysis of method performance based on insufficient, borderline and/or conflicting data to confidently categorized the chemicals as allergens or non-allergens. Of the 29 chemicals included in this analysis, 17 were classified as negative and would be correctly identified using a 2 out of 3 approach while 8 chemicals were classified as positive in vivo and would be false-negative with this approach. For some of these chemicals, the outcomes observed can be explained by in vitro borderline results (13 chemicals) or in some instances there is mechanistic understanding of why a chemical is positive or negative in a particular assay (9 chemicals). Thus, when comparing the performance of different defined approaches, one should attempt to only include chemicals which demonstrate clear evidence to be categorize as allergens or non-allergens. Finally, when interpreting the results obtained for an individual unknown chemical it is critical that the in vitro skin sensitization data is reviewed critically and there is a good understanding of the variance and applicability domain limitations for each assay being used.


Assuntos
Dermatite Alérgica de Contato , Compostos Orgânicos/efeitos adversos , Testes Cutâneos , Pele/efeitos dos fármacos , Animais , Humanos , Técnicas In Vitro , Testes Cutâneos/normas
10.
Regul Toxicol Pharmacol ; 89: 125-130, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28734851

RESUMO

Several in vitro methods have gained regulatory acceptance for the prediction of skin irritation and corrosion. However, the test guidelines for the majority of in vitro methods do not state whether they are applicable to agrochemical formulations. Hence, we would like to share the results from our routine skin corrosion and irritation testing of agrochemical formulations in which both in vitro (according to OECD TG 431 and OECD TG 439) and in vivo (according to OECD TG 404) tests were conducted as regulatory requirements. The in vitro skin irritation test did not correlate well with the CLP classification by in vivo results (44% sensitivity, 60% specificity, and 54% accuracy, based on 65 data pairs). This indicates a lack of applicability of the current protocol of the in vitro skin irritation test for agrochemical formulations. The data set did not contain formulations which were skin corrosive in vivo and hence its applicability could not be assessed. The correlation of in vitro skin corrosion testing to formulations which were not corrosive in vivo was, however, high (95% specificity based on 81 data pairs).


Assuntos
Agroquímicos/química , Agroquímicos/toxicidade , Testes de Irritação da Pele/métodos , Animais , Irritantes/toxicidade , Coelhos , Sensibilidade e Especificidade , Pele/efeitos dos fármacos
11.
Regul Toxicol Pharmacol ; 85: 33-47, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28163171

RESUMO

In vitro methods have gained regulatory acceptance for the prediction of serious eye damage (UN GHS Cat 1). However, the majority of in vitro methods do not state whether they are applicable to agrochemical formulations. This manuscript presents a study of up to 27 agrochemical formulations tested in three in vitro assays (three versions of the bovine corneal opacity and permeability test (BCOP, OECD TG 437) assay, the isolated chicken eye test (ICE, OECD TG 438) and the EpiOcular™ ET-50 assay). The results were compared with already-available in vivo data. In the BCOP only one of the four, one of five in the ICE and six of eleven tested formulations in the EpiOcular™ ET-50 Neat Protocol resulted in the correct UN GHS Cat 1 prediction. Overpredictions occurred in all assays. These data indicate a lack of applicability of the three in vitro methods to reliably predict UN GHS Cat 1 of agrochemical formulations. In order to ensure animal-free identification of seriously eye damaging agrochemical formulations testing protocols and/or prediction models need to be modified or classification rules should be tailored to in vitro testing rather than using in vivo Draize data as a standard.


Assuntos
Agroquímicos/classificação , Agroquímicos/toxicidade , Olho/efeitos dos fármacos , Irritantes/classificação , Irritantes/toxicidade , Agroquímicos/farmacocinética , Alternativas aos Testes com Animais , Animais , Bovinos , Galinhas , Opacidade da Córnea , Olho/metabolismo , Feminino , Humanos , Técnicas In Vitro , Irritantes/farmacocinética , Masculino , Permeabilidade , Coelhos , Testes de Toxicidade
12.
Part Fibre Toxicol ; 13: 18, 2016 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-27083156

RESUMO

BACKGROUND: Assessment of eye irritation hazard has long been a core requirement in any chemical legislation. Nevertheless, publications focussing on the eye damaging potential of nanomaterials are scarce. Traditionally, eye irritation testing was performed using rabbits. The OECD Test Guideline 437 Bovine Corneal Opacity and Permeability (BCOP) test method allows determining severely irritating substances without animals, and the recently adopted OECD Test Guideline 492 Reconstructed human cornea-like epithelium test method allows identifying chemicals that neither induce eye irritation nor serious eye damage. For substances applicable to these tests, huge progress has been made in replacing animal testing. METHODS: The in vitro eye irritation potential of 20 nanosized and 3 non-nanosized materials was investigated in a 2-tier EpiOcular™ Eye Irritation Test (EpiOcular™-EIT) and BCOP testing strategy including histopathology of the bovine corneas. Furthermore, applicability of the testing strategy for nanomaterials was assessed. Test materials encompassed OECD representative nanomaterials (metals (Ag), metal oxides (ZnO, TiO2, CeO2), amorphous SiO2 and MWCNTs), three organic pigments, quartz, and talc. RESULTS: None of the dry-powder nanomaterials elicited eye irritation in either the EpiOcular™-EIT or the BCOP assay. Likewise, an amorphous SiO2 nanomaterial that was supplied as suspension was tested negative in both assays. By contrast, in the EpiOcular™-EIT, the silver nanomaterial that was supplied as dispersion was tested positive, whereas its surfactant-containing dispersant was borderline to negative. In the BCOP assay, the silver nanomaterial elicited highly variable results and dark-brown patches remained on the corneal surface, whereas the results for its dispersant alone were borderline to positive, which was assessed as inconclusive due to high inter-assay variability. CONCLUSION: The present study points to the low eye irritation potential of a spectrum of nanomaterials, which is consistent with available in vivo data for the same test materials or for nanosized or bulk materials of the same composition.


Assuntos
Córnea/efeitos dos fármacos , Opacidade da Córnea/induzido quimicamente , Irritantes/toxicidade , Nanopartículas/toxicidade , Testes de Toxicidade/métodos , Alternativas aos Testes com Animais , Animais , Bioensaio , Bovinos , Córnea/metabolismo , Córnea/patologia , Opacidade da Córnea/metabolismo , Opacidade da Córnea/patologia , Humanos , Nanotecnologia , Permeabilidade , Medição de Risco , Técnicas de Cultura de Tecidos , Sobrevivência de Tecidos/efeitos dos fármacos
13.
Altern Lab Anim ; 44(3): 281-99, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27494627

RESUMO

In general, no single non-animal method can cover the complexity of any given animal test. Therefore, fixed sets of in vitro (and in chemico) methods have been combined into testing strategies for skin and eye irritation and skin sensitisation testing, with pre-defined prediction models for substance classification. Many of these methods have been adopted as OECD test guidelines. Various testing strategies have been successfully validated in extensive in-house and inter-laboratory studies, but they have not yet received formal acceptance for substance classification. Therefore, under the European REACH Regulation, data from testing strategies can, in general, only be used in so-called weight-of-evidence approaches. While animal testing data generated under the specific REACH information requirements are per se sufficient, the sufficiency of weight-of-evidence approaches can be questioned under the REACH system, and further animal testing can be required. This constitutes an imbalance between the regulatory acceptance of data from approved non-animal methods and animal tests that is not justified on scientific grounds. To ensure that testing strategies for local tolerance testing truly serve to replace animal testing for the REACH registration 2018 deadline (when the majority of existing chemicals have to be registered), clarity on their regulatory acceptance as complete replacements is urgently required.


Assuntos
Alternativas aos Testes com Animais , Dermatite de Contato , Substâncias Perigosas/toxicidade , Testes de Toxicidade/normas , Animais , União Europeia , Oftalmopatias/induzido quimicamente , Traumatismos Oculares/induzido quimicamente , Legislação de Medicamentos , Dermatopatias/induzido quimicamente
14.
J Appl Toxicol ; 35(4): 434-45, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25186098

RESUMO

The local lymph node assay (LLNA) is a regulatory accepted test for the identification of skin sensitizing substances by measuring radioactive thymidine incorporation into the lymph node. However, there is evidence that LLNA is overestimating the sensitization potential of certain substance classes in particular those exerting skin irritation. Some reports describe the additional use of flow cytometry-based immunophenotyping to better discriminate irritants from sensitizing irritants in LLNA. In the present study, the 22 performance standards plus 8 surfactants were assessed using the radioactive LLNA method. In addition, lymph node cells were immunophenotyped to evaluate the specificity of the lymph node response using cell surface markers such as B220 or CD19, CD3, CD4, CD8, I-A(κ) and CD69 with the aim to allow a better discrimination above all between irritants and sensitizers, but also non-irritating sensitizers and non-sensitizers. However, the markers assessed in this study do not sufficiently differentiate between irritants and irritant sensitizers and therefore did not improve the predictive capacity of the LLNA.


Assuntos
Haptenos/toxicidade , Irritantes/toxicidade , Linfonodos/efeitos dos fármacos , Linfócitos/efeitos dos fármacos , Modelos Biológicos , Animais , Antígenos de Superfície/metabolismo , Dermatite de Contato/imunologia , Dermatite de Contato/metabolismo , Feminino , Imunofenotipagem , Ensaio Local de Linfonodo , Linfonodos/imunologia , Linfonodos/metabolismo , Linfócitos/imunologia , Linfócitos/metabolismo , Camundongos Endogâmicos CBA , Tensoativos/química
15.
Altern Lab Anim ; 43(3): 181-98, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26256396

RESUMO

The Bovine Corneal Opacity and Permeability (BCOP) test is commonly used for the identification of severe ocular irritants (GHS Category 1), but it is not recommended for the identification of ocular irritants (GHS Category 2). The incorporation of human reconstructed tissue model-based tests into a tiered test strategy to identify ocular non-irritants and replace the Draize rabbit eye irritation test has been suggested (OECD TG 405). The value of the EpiOcular™ Eye Irritation Test (EIT) for the prediction of ocular non-irritants (GHS No Category) has been demonstrated, and an OECD Test Guideline (TG) was drafted in 2014. The purpose of this study was to evaluate whether the BCOP test, in conjunction with corneal histopathology (as suggested for the evaluation of the depth of the injury( and/or the EpiOcular-EIT, could be used to predict the eye irritation potential of agrochemical formulations according to the UN GHS, US EPA and Brazil ANVISA classification schemes. We have assessed opacity, permeability and histopathology in the BCOP assay, and relative tissue viability in the EpiOcular-EIT, for 97 agrochemical formulations with available in vivo eye irritation data. By using the OECD TG 437 protocol for liquids, the BCOP test did not result in sufficient correct predictions of severe ocular irritants for any of the three classification schemes. The lack of sensitivity could be improved somewhat by the inclusion of corneal histopathology, but the relative viability in the EpiOcular-EIT clearly outperformed the BCOP test for all three classification schemes. The predictive capacity of the EpiOcular-EIT for ocular non-irritants (UN GHS No Category) for the 97 agrochemical formulations tested (91% sensitivity, 72% specificity and 82% accuracy for UN GHS classification) was comparable to that obtained in the formal validation exercise underlying the OECD draft TG. We therefore conclude that the EpiOcular-EIT is currently the best in vitro method for the prediction of the eye irritation potential of liquid agrochemical formulations.


Assuntos
Agroquímicos/toxicidade , Alternativas aos Testes com Animais , Bioensaio , Irritantes/análise , Testes de Toxicidade/métodos , Animais , Brasil , Bovinos , Opacidade da Córnea/induzido quimicamente , Olho/efeitos dos fármacos , Humanos , Irritantes/toxicidade , Coelhos , Nações Unidas , Estados Unidos , United States Environmental Protection Agency
16.
Toxicol Appl Pharmacol ; 276(1): 1-20, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24382512

RESUMO

The applicability of rat precision-cut lung slices (PCLuS) in detecting nanomaterial (NM) toxicity to the respiratory tract was investigated evaluating sixteen OECD reference NMs (TiO2, ZnO, CeO2, SiO2, Ag, multi-walled carbon nanotubes (MWCNTs)). Upon 24-hour test substance exposure, the PCLuS system was able to detect early events of NM toxicity: total protein, reduction in mitochondrial activity, caspase-3/-7 activation, glutathione depletion/increase, cytokine induction, and histopathological evaluation. Ion shedding NMS (ZnO and Ag) induced severe tissue destruction detected by the loss of total protein. Two anatase TiO2 NMs, CeO2 NMs, and two MWCNT caused significant (determined by trend analysis) cytotoxicity in the WST-1 assay. At non-cytotoxic concentrations, different TiO2 NMs and one MWCNT increased GSH levels, presumably a defense response to reactive oxygen species, and these substances further induced a variety of cytokines. One of the SiO2 NMs increased caspase-3/-7 activities at non-cytotoxic levels, and one rutile TiO2 only induced cytokines. Investigating these effects is, however, not sufficient to predict apical effects found in vivo. Reproducibility of test substance measurements was not fully satisfactory, especially in the GSH and cytokine assays. Effects were frequently observed in negative controls pointing to tissue slice vulnerability even though prepared and handled with utmost care. Comparisons of the effects observed in the PCLuS to in vivo effects reveal some concordances for the metal oxide NMs, but less so for the MWCNT. The highest effective dosages, however, exceeded those reported for rat short-term inhalation studies. To become applicable for NM testing, the PCLuS system requires test protocol optimization.


Assuntos
Apoptose/efeitos dos fármacos , Pulmão/efeitos dos fármacos , Nanotubos/toxicidade , Estresse Oxidativo/efeitos dos fármacos , Alternativas ao Uso de Animais , Animais , Sobrevivência Celular , Fenômenos Químicos , Cruzamentos Genéticos , Citocinas/metabolismo , Emulsificantes/química , Feminino , Glutationa/agonistas , Glutationa/metabolismo , Técnicas In Vitro , Pulmão/citologia , Pulmão/imunologia , Pulmão/metabolismo , Teste de Materiais/métodos , Nanopartículas Metálicas/química , Nanopartículas Metálicas/toxicidade , Nanopartículas Metálicas/ultraestrutura , Nanotubos/química , Nanotubos/ultraestrutura , Nanotubos de Carbono/química , Nanotubos de Carbono/toxicidade , Nanotubos de Carbono/ultraestrutura , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Soroalbumina Bovina/química , Sonicação , Regulação para Cima/efeitos dos fármacos
17.
Toxics ; 12(8)2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39195718

RESUMO

Since 2020, the REACh regulation requires toxicological data on nanoforms of materials, including the assessment of their skin-sensitizing properties. Small molecules' skin sensitization potential can be assessed by new approach methodologies (NAMs) addressing three key events (KE: protein interaction, activation of dendritic cells, and activation of keratinocytes) combined in a defined approach (DA) described in the OECD guideline 497. In the present study, the applicability of three NAMs (DPRA, LuSens, and h-CLAT) to nine materials (eight inorganic nanomaterials (NM) consisting of CeO2, BaSO4, TiO2 or SiO2, and quartz) was evaluated. The NAMs were technically applicable to NM using a specific sample preparation (NANOGENOTOX dispersion protocol) and method modifications to reduce interaction of NM with the photometric and flowcytometric read-outs. The results of the three assays were combined according to the defined approach described in the OECD guideline No. 497; two of the inorganic NM were identified as skin sensitizers. However, data from animal studies (for ZnO, also human data) indicate no skin sensitization potential. The remaining seven test substances were assessed as "inconclusive" because all inorganic NM were outside the domain of the DPRA, and the achievable test concentrations were not sufficiently high according to the current test guidelines of all three NAMs. The use of these NAMs for (inorganic) NM and the relevance of the results in general are challenged in three ways: (i) NAMs need modification to be applicable to insoluble, inorganic matter; (ii) current test guidelines lack adequate concentration metrics and top concentrations achievable for NM; and (iii) NM may not cause skin sensitization by the same molecular and cellular key events as small organic molecules do; in fact, T-cell-mediated hypersensitivity may not be the most relevant reaction of the immune system to NM. We conclude that the NAMs adopted by OECD test guidelines are currently not a good fit for testing inorganic NM.

18.
Regul Toxicol Pharmacol ; 65(3): 366-78, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23646360

RESUMO

Skin corrosion or irritation refers to the production of irreversible or reversible damage to the skin following the application of a test substance, respectively. Traditionally, hazard assessments are conducted using the in vivo Draize skin test, but recently in vitro tests using reconstructed human epidermis (RhE) models have gained regulatory acceptance. In this study, skin corrosion (SCT) and irritation tests (SIT) using a RhE model were implemented to reduce the number of in vivo tests required by regulatory bodies. One hundred and thirty-four materials were tested from a wide range of substance classes included 46 agrochemical formulations. Results were assessed according to UN GHS, EU-CLP, ANVISA and US EPA classification schemes. There was high correlation between the two in vitro tests. Assessment of the SCT sensitivity was not possible due to the limited number of corrosives in the data set; SCT specificity and accuracy were 89% for all classification systems. Accuracy (63­76%) and sensitivity (53­67%) were low in the SIT. Specificity and concordance for agrochemical formulations alone in both the SCT and SIT were comparable to the values for the complete data set (SCT: 91% vs. 89% specificity, 91% vs. 89% accuracy and SIT: 64­88% vs. 70­85% specificity, 56­75% vs. 63­76% accuracy).


Assuntos
Irritantes/toxicidade
19.
Regul Toxicol Pharmacol ; 65(2): 278-85, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23279805

RESUMO

To encourage the development and validation of alternative toxicity test methods, the effort required for validation of test methods proposed for regulatory purposes should be minimized. Performance standards (PS) facilitate efficient validation by requiring limited testing. Based on the validated method, PS define accuracy and reliability values that must be met by the new similar test method. The OECD adopted internationally harmonized PS for evaluating new endpoint versions of the local lymph node assay (LLNA). However, in the process of evaluating a lymph node cell count alternative (LNCC), simultaneous conduct of the regulatory LLNA showed that this standard test may not always perform in perfect accord with its own PS. The LNCC results were similar to the concurrent LLNA. Discrepancies between PS, LLNA and LNCC were largely associated with "borderline" substances and the variability of both endpoints. Two key lessons were learned: firstly, the understandable focus on substances close to the hazard classification borderline are more likely to emphasise issues of biological variability, which should be taken into account during the evaluation of results; secondly, variability in the results for the standard assay should be considered when selecting reference chemicals for PS.


Assuntos
Alérgenos/toxicidade , Alternativas aos Testes com Animais/métodos , Dermatite de Contato/etiologia , Hipersensibilidade/etiologia , Testes de Toxicidade/métodos , Alérgenos/classificação , Alternativas aos Testes com Animais/normas , Animais , Dermatite de Contato/imunologia , Dermatite de Contato/patologia , Humanos , Hipersensibilidade/imunologia , Ensaio Local de Linfonodo , Reprodutibilidade dos Testes , Testes de Irritação da Pele , Testes de Toxicidade/normas
20.
Regul Toxicol Pharmacol ; 64(3): 402-14, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22939940

RESUMO

Skin corrosion or irritation refers to the production of irreversible or reversible damage to the skin following the application of a test substance, respectively. Traditionally, hazard assessments are conducted using the in vivo Draize skin test, but recently in vitro tests using reconstructed human epidermis (RhE) models have gained regulatory acceptance. In this study, skin corrosion (SCT) and irritation tests (SIT) using a RhE model were implemented to reduce the number of in vivo tests required by regulatory bodies. One hundred and thirty-four materials were tested from a wide range of substance classes included 46 agrochemical formulations. Results were assessed according to UN GHS, EU-CLP, ANVISA and US EPA classification schemes. There was high correlation between the two in vitro tests. Assessment of the SCT sensitivity was not possible due to the limited number of corrosives in the data set; SCT specificity and accuracy were 89% for all classification systems. Accuracy (63-76%) and sensitivity (53-67%) were low in the SIT. Specificity and concordance for agrochemical formulations alone in both the SCT and SIT were comparable to the values for the complete data set (SCT: 91% vs. 89% specificity, 91% vs. 89% accuracy and SIT: 64-88% vs. 70-85% specificity, 56-75% vs. 63-76% accuracy).


Assuntos
Agroquímicos/toxicidade , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Irritantes/toxicidade , Pele/efeitos dos fármacos , Animais , Humanos , Irritantes/classificação , Coelhos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Pele/metabolismo , Pele/patologia , Testes de Irritação da Pele/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA