Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Monit Comput ; 37(5): 1193-1205, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36745316

RESUMO

Acute kidney injury (AKI) is frequently seen in patients with hemorrhagic shock due to hypotension, tissue hypoxia, and inflammation despite adequate resuscitation. There is a lack of information concerning the alteration of renal microcirculation and perfusion during shock and resuscitation. The aim of this study was to investigate the possible role of renal microcirculatory alterations on development of renal dysfunction in a pig model of non-traumatic hemorrhagic shock (HS) induced AKI.Fully instrumented female pigs were divided into the two groups as Control (n = 6) and HS (n = 11). HS was achieved by withdrawing blood until mean arterial pressure (MAP) reached around 50 mmHg. After an hour cessation period, fluid resuscitation with balanced crystalloid was started for the duration of 1 h. The systemic and renal hemodynamics, renal microcirculatory perfusion (contrast-enhanced ultrasound (CEUS)) and the sublingual microcirculation were measured.CEUS peak enhancement was significantly increased in HS during shock, early-, and late resuscitation indicating perfusion defects in the renal cortex (p < 0.05 vs. baseline, BL) despite a stable renal blood flow (RBF) and urine output. Following normalization of systemic hemodynamics, we observed persistent hypoxia (high lactate) and high red blood cell (RBC) velocity just after initiation of resuscitation resulting in further endothelial and renal damage as shown by increased plasma sialic acid (p < 0.05 vs. BL) and NGAL levels. We also showed that total vessel density (TVD) and functional capillary density (FCD) were depleted during resuscitation (p < 0.05).In this study, we showed that the correction of systemic hemodynamic variables may not be accompanied with the improvement of renal cortical perfusion, intra-renal blood volume and renal damage following fluid resuscitation. We suggest that the measurement of renal injury biomarkers, systemic and renal microcirculation can be used for guiding to the optimization of fluid therapies.


Assuntos
Injúria Renal Aguda , Choque Hemorrágico , Humanos , Feminino , Animais , Suínos , Choque Hemorrágico/terapia , Microcirculação , Rim , Hidratação/métodos , Hipóxia , Ressuscitação/métodos , Hemodinâmica
2.
Langmuir ; 36(12): 3221-3233, 2020 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-32109064

RESUMO

Phospholipid-coated targeted microbubbles are ultrasound contrast agents that can be used for molecular imaging and enhanced drug delivery. However, a better understanding is needed of their targeting capabilities and how they relate to microstructures in the microbubble coating. Here, we investigated the ligand distribution, lipid phase behavior, and their correlation in targeted microbubbles of clinically relevant sizes, coated with a ternary mixture of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) or 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC), with PEG40-stearate and DSPE-PEG2000. To investigate the effect of lipid handling prior to microbubble production in DSPC-based microbubbles, the components were either dispersed in aqueous medium (direct method) or first dissolved and mixed in an organic solvent (indirect method). To determine the lipid-phase behavior of all components, experiments were conducted on monolayers at the air/water interface. In comparison to pure DSPC and DPPC, the ternary mixtures had an additional transition plateau around 10-12 mN/m. As confirmed by infrared reflection absorption spectroscopy (IRRAS), this plateau was due to a transition in the conformation of the PEGylated components (mushroom to brush). While the condensed phase domains had a different morphology in the ternary DPPC and DSPC monolayers on the Langmuir trough, the domain morphology was similar in the coating of both ternary DPPC and DSPC microbubbles (1.5-8 µm diameter). The ternary DPPC microbubbles had a homogenous ligand distribution and significantly less liquid condensed (LC) phase area in their coating than the DSPC-based microbubbles. For ternary DSPC microbubbles, the ligand distribution and LC phase area in the coating depended on the lipid handling. The direct method resulted in a heterogeneous ligand distribution, less LC phase area than the indirect method, and the ligand colocalizing with the liquid expanded (LE) phase area. The indirect method resulted in a homogenous ligand distribution with the largest LC phase area. In conclusion, lipid handling prior to microbubble production is of importance for a ternary mixture of DSPC, PEG40-stearate, and DSPE-PEG2000.

3.
Crit Care Med ; 46(8): 1284-1292, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29771701

RESUMO

OBJECTIVES: We developed quantitative methods to analyze microbubble kinetics based on renal contrast-enhanced ultrasound imaging combined with measurements of sublingual microcirculation on a fixed area to quantify early microvascular alterations in sepsis-induced acute kidney injury. DESIGN: Prospective controlled animal experiment study. SETTING: Hospital-affiliated animal research institution. SUBJECTS: Fifteen female pigs. INTERVENTIONS: The animals were instrumented with a renal artery flow probe after surgically exposing the kidney. Nine animals were given IV infusion of lipopolysaccharide to induce septic shock, and six were used as controls. MEASUREMENTS AND MAIN RESULTS: Contrast-enhanced ultrasound imaging was performed on the kidney before, during, and after having induced shock. Sublingual microcirculation was measured continuously using the Cytocam on the same spot. Contrast-enhanced ultrasound effectively allowed us to develop new analytical methods to measure dynamic variations in renal microvascular perfusion during shock and resuscitation. Renal microvascular hypoperfusion was quantified by decreased peak enhancement and an increased ratio of the final plateau intensity to peak enhancement. Reduced intrarenal blood flow could be estimated by measuring the microbubble transit times between the interlobar arteries and capillary vessels in the renal cortex. Sublingual microcirculation measured using the Cytocam in a fixed area showed decreased functional capillary density associated with plugged sublingual capillary vessels that persisted during and after fluid resuscitation. CONCLUSIONS: In our lipopolysaccharide model, with resuscitation targeted at blood pressure, contrast-enhanced ultrasound imaging can identify renal microvascular alterations by showing prolonged contrast enhancement in microcirculation during shock, worsened by resuscitation with fluids. Concomitant analysis of sublingual microcirculation mirrored those observed in the renal microcirculation.


Assuntos
Injúria Renal Aguda/diagnóstico por imagem , Injúria Renal Aguda/etiologia , Microcirculação/fisiologia , Sepse/complicações , Ultrassonografia/métodos , Animais , Modelos Animais de Doenças , Feminino , Hemodinâmica , Humanos , Rim/irrigação sanguínea , Rim/diagnóstico por imagem , Lipopolissacarídeos/farmacologia , Estudos Prospectivos , Sepse/induzido quimicamente , Suínos
4.
Biophys J ; 112(9): 1894-1907, 2017 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-28494960

RESUMO

Polymeric microcapsules with a light-absorbing dye incorporated in their shell can generate vapor microbubbles that can be spatiotemporally controlled by pulsed laser irradiation. These contrast agents of 6-8 µm in diameter can circulate through the vasculature, offering possibilities for ultrasound (molecular) imaging and targeted therapies. Here, we study the impact of such vapor bubbles on human endothelial cells in terms of cell poration and cell viability to establish the imaging and therapeutic windows. Two capsule formulations were used: the first one consisted of a high boiling point oil (hexadecane), whereas the second was loaded with a low boiling point oil (perfluoropentane). Poration probability was already 40% for the smallest bubbles that were formed (<7.5 µm diameter), and reached 100% for the larger bubbles. The hexadecane-loaded capsules also produced bubbles while their shell remained intact. These encapsulated bubbles could therefore be used for noninvasive ultrasound imaging after laser activation without inducing any cell damage. The controlled and localized cell destruction achieved by activation of both capsule formulations may provide an innovative approach for specifically inducing cell death in vivo, e.g., for cancer therapy.


Assuntos
Meios de Contraste , Lasers , Microbolhas , Imagem Molecular , Ultrassonografia , Alcanos , Cápsulas , Permeabilidade da Membrana Celular , Sobrevivência Celular , Células Endoteliais/citologia , Células Endoteliais/metabolismo , Estudos de Viabilidade , Fluorocarbonos , Células Endoteliais da Veia Umbilical Humana , Humanos , Ácido Láctico , Ácido Poliglicólico , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Polímeros , Polimetil Metacrilato , Volatilização
6.
Eur J Nucl Med Mol Imaging ; 42(4): 579-96, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25673052

RESUMO

In view of the trend towards personalized treatment strategies for (cancer) patients, there is an increasing need to noninvasively determine individual patient characteristics. Such information enables physicians to administer to patients accurate therapy with appropriate timing. For the noninvasive visualization of disease-related features, imaging biomarkers are expected to play a crucial role. Next to the chemical development of imaging probes, this requires preclinical studies in animal tumour models. These studies provide proof-of-concept of imaging biomarkers and help determine the pharmacokinetics and target specificity of relevant imaging probes, features that provide the fundamentals for translation to the clinic. In this review we describe biological processes derived from the "hallmarks of cancer" that may serve as imaging biomarkers for diagnostic, prognostic and treatment response monitoring that are currently being studied in the preclinical setting. A number of these biomarkers are also being used for the initial preclinical assessment of new intervention strategies. Uniquely, noninvasive imaging approaches allow longitudinal assessment of changes in biological processes, providing information on the safety, pharmacokinetic profiles and target specificity of new drugs, and on the antitumour effectiveness of therapeutic interventions. Preclinical biomarker imaging can help guide translation to optimize clinical biomarker imaging and personalize (combination) therapies.


Assuntos
Biomarcadores Tumorais/metabolismo , Diagnóstico por Imagem , Neoplasias/diagnóstico , Animais , Neoplasias/diagnóstico por imagem , Radiografia , Cintilografia , Compostos Radiofarmacêuticos/farmacocinética
7.
Int J Hyperthermia ; 31(2): 90-106, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25707815

RESUMO

Ultrasound contrast agents (UCAs) are used routinely in the clinic to enhance contrast in ultrasonography. More recently, UCAs have been functionalised by conjugating ligands to their surface to target specific biomarkers of a disease or a disease process. These targeted UCAs (tUCAs) are used for a wide range of pre-clinical applications including diagnosis, monitoring of drug treatment, and therapy. In this review, recent achievements with tUCAs in the field of molecular imaging, evaluation of therapy, drug delivery, and therapeutic applications are discussed. We present the different coating materials and aspects that have to be considered when manufacturing tUCAs. Next to tUCA design and the choice of ligands for specific biomarkers, additional techniques are discussed that are applied to improve binding of the tUCAs to their target and to quantify the strength of this bond. As imaging techniques rely on the specific behaviour of tUCAs in an ultrasound field, it is crucial to understand the characteristics of both free and adhered tUCAs. To image and quantify the adhered tUCAs, the state-of-the-art techniques used for ultrasound molecular imaging and quantification are presented. This review concludes with the potential of tUCAs for drug delivery and therapeutic applications.


Assuntos
Meios de Contraste/administração & dosagem , Aumento da Imagem/métodos , Imagem Molecular/métodos , Terapia por Ultrassom , Ultrassonografia , Sistemas de Liberação de Medicamentos , Humanos , Microbolhas
8.
J Acoust Soc Am ; 137(4): 1693-703, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25920822

RESUMO

An optical characterization method is presented based on the use of the impulse response to characterize the damping imparted by the shell of an air-filled ultrasound contrast agent (UCA). The interfacial shell viscosity was estimated based on the unforced decaying response of individual echogenic liposomes (ELIP) exposed to a broadband acoustic impulse excitation. Radius versus time response was measured optically based on recordings acquired using an ultra-high-speed camera. The method provided an efficient approach that enabled statistical measurements on 106 individual ELIP. A decrease in shell viscosity, from 2.1 × 10(-8) to 2.5 × 10(-9) kg/s, was observed with increasing dilatation rate, from 0.5 × 10(6) to 1 × 10(7) s(-1). This nonlinear behavior has been reported in other studies of lipid-shelled UCAs and is consistent with rheological shear-thinning. The measured shell viscosity for the ELIP formulation used in this study [κs = (2.1 ± 1.0) × 10(-8) kg/s] was in quantitative agreement with previously reported values on a population of ELIP and is consistent with other lipid-shelled UCAs. The acoustic response of ELIP therefore is similar to other lipid-shelled UCAs despite loading with air instead of perfluorocarbon gas. The methods described here can provide an accurate estimate of the shell viscosity and damping for individual UCA microbubbles.


Assuntos
Lipossomos/química , Ondas Ultrassônicas , Acústica , Meios de Contraste , Microbolhas , Viscosidade
9.
Artigo em Inglês | MEDLINE | ID: mdl-37027575

RESUMO

Understanding and controlling the ultrasound contrast agent (UCA)'s response to an applied ultrasound pressure field are crucial when investigating ultrasound imaging sequences and therapeutic applications. The magnitude and frequency of the applied ultrasonic pressure waves affect the oscillatory response of the UCA. Therefore, it is important to have an ultrasound compatible and optically transparent chamber in which the acoustic response of the UCA can be studied. The aim of our study was to determine the in situ ultrasound pressure amplitude in the ibidi µ -slide I Luer channel, an optically transparent chamber suitable for cell culture, including culture under flow, for all microchannel heights (200, 400, 600, and [Formula: see text]). First, the in situ pressure field in the 800- [Formula: see text] high channel was experimentally characterized using Brandaris 128 ultrahigh-speed camera recordings of microbubbles (MBs) and a subsequent iterative processing method, upon insonification at 2 MHz, 45° incident angle, and 50-kPa peak negative pressure (PNP). Control studies in another cell culture chamber, the CLINIcell, were compared with the obtained results. The pressure amplitude was -3.7 dB with respect to the pressure field without the ibidi µ -slide. Second, using finite-element analysis, we determined the in situ pressure amplitude in the ibidi with the 800- [Formula: see text] channel (33.1 kPa), which was comparable to the experimental value (34 kPa). The simulations were extended to the other ibidi channel heights (200, 400, and [Formula: see text]) with either 35° or 45° incident angle, and at 1 and 2 MHz. The predicted in situ ultrasound pressure fields were between -8.7 and -1.1 dB of the incident pressure field depending on the listed configurations of ibidi slides with different channel heights, applied ultrasound frequencies, and incident angles. In conclusion, the determined ultrasound in situ pressures demonstrate the acoustic compatibility of the ibidi µ -slide I Luer for different channel heights, thereby showing its potential for studying the acoustic behavior of UCAs for imaging and therapy.


Assuntos
Meios de Contraste , Ultrassom , Ultrassonografia/métodos , Ondas Ultrassônicas , Acústica , Microbolhas
10.
Ultrasound Med Biol ; 49(1): 388-397, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36241587

RESUMO

Ultrasound contrast-mediated medical imaging and therapy both rely on the dynamics of micron- and nanometer-sized ultrasound cavitation nuclei, such as phospholipid-coated microbubbles and phase-change droplets. Ultrasound cavitation nuclei respond non-linearly to ultrasound on a nanosecond time scale that necessitates the use of ultra-high-speed imaging to fully visualize these dynamics in detail. In this study, we developed an ultra-high-speed optical imaging system that can record up to 20 million frames per second (Mfps) by coupling two small-sized, commercially available, 10-Mfps cameras. The timing and reliability of the interleaved cameras needed to achieve 20 Mfps was validated using two synchronized light-emitting diode strobe lights. Once verified, ultrasound-activated microbubble responses were recorded and analyzed. A unique characteristic of this coupled system is its ability to be reconfigured to provide orthogonal observations at 10 Mfps. Acoustic droplet vaporization was imaged from two orthogonal views, by which the 3-D dynamics of the phase transition could be visualized. This optical imaging system provides the temporal resolution and experimental flexibility needed to further elucidate the dynamics of ultrasound cavitation nuclei to potentiate the clinical translation of ultrasound-mediated imaging and therapy developments.


Assuntos
Meios de Contraste , Microbolhas , Reprodutibilidade dos Testes , Ultrassonografia , Volatilização
11.
Shock ; 57(3): 457-466, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34559745

RESUMO

ABSTRACT: Acute normovolemic hemodilution (ANH) is associated with low oxygen carrying capacity of blood and purposed to cause renal injury in perioperative setting. It is best accomplished in a perioperative setting by a colloid such as hydroxyl ethyl starch (HES) due its capacity to fill the vascular compartment and maintain colloidal pressure. However, alterations of intra renal microvascular perfusion, flow and its effects on renal function and damage during ANH has not been sufficiently clarified. Based on the extensive use of HES in the perioperative setting we tested the hypothesis that the use of HES during ANH is able to perfuse the kidney microcirculation adequately without causing renal dysfunction and injury in pigs. Hemodilution (n = 8) was performed by stepwise replacing blood with HES to hematocrit (Hct) levels of 20% (T1), 15% (T2), and 10% (T3). Seven control animals were investigated. Systemic and renal hemodynamics were monitored. Renal microcirculatory perfusion was visualized and quantified using contrast-enhanced ultrasound (CEUS) and laser speckle imaging (LSI). In addition, sublingual microcirculation was measured by handheld vital microscopy (HVM). Intrarenal mean transit time of ultrasound contrast agent (IRMTT-CEUS) was reduced in the renal cortex at Hct 10% in comparison to control at T3 (1.4 ±â€Š0.6 vs. 2.2 ±â€Š0.7 seconds, respectively, P < 0.05). Although renal function was preserved, the serum neutrophil gelatinase-associated lipocalin (NGAL) levels was higher at Hct 10% (0.033 ±â€Š0.004 pg/µg protein) in comparison to control at T3 (0.021 ±â€Š0.002 pg/µg protein. A mild correlation between CO and IRMTT (renal RBC velocity) (r -0.53; P = 0.001) and CO and NGAL levels (r 0.66; P = 0.001) was also found. Our results show that HES induced ANH is associated with a preserved intra renal blood volume, perfusion, and function in the clinical range of Hct (<15%). However, at severely low Hct (10%) ANH was associated with renal injury as indicated by increased NGAL levels. Changes in renal microcirculatory flow (CEUS and LSI) followed those seen in the sublingual microcirculation measured with HVM.


Assuntos
Injúria Renal Aguda/prevenção & controle , Hemodiluição/efeitos adversos , Derivados de Hidroxietil Amido/uso terapêutico , Rim/irrigação sanguínea , Microcirculação/efeitos dos fármacos , Substitutos do Plasma/uso terapêutico , Injúria Renal Aguda/etiologia , Animais , Meios de Contraste , Modelos Animais de Doenças , Feminino , Hematócrito , Rim/diagnóstico por imagem , Imagem de Contraste de Manchas a Laser , Lipocalina-2/sangue , Suínos , Ultrassonografia
12.
Pharmaceutics ; 14(2)2022 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-35214044

RESUMO

Phospholipid-coated targeted microbubbles are used for ultrasound molecular imaging and locally enhanced drug delivery, with the binding efficacy being an important trait. The use of organic solvent in microbubble production makes the difference between a heterogeneous or homogeneous ligand distribution. This study demonstrates the effect of ligand distribution on the binding efficacy of phospholipid-coated ανß3-targeted microbubbles in vitro using a monolayer of human umbilical-vein endothelial cells and in vivo using chicken embryos. Microbubbles with a homogeneous ligand distribution had a higher binding efficacy than those with a heterogeneous ligand distribution both in vitro and in vivo. In vitro, 1.55× more microbubbles with a homogeneous ligand distribution bound under static conditions, while this was 1.49× more under flow with 1.25 dyn/cm2, 1.56× more under flow with 2.22 dyn/cm2, and 1.25× more in vivo. The in vitro dissociation rate of bound microbubbles with homogeneous ligand distribution was lower at low shear stresses (1-5 dyn/cm2). The internalized depth of bound microbubbles was influenced by microbubble size, not by ligand distribution. In conclusion, for optimal binding the use of organic solvent in targeted microbubble production is preferable over directly dispersing phospholipids in aqueous medium.

13.
J Control Release ; 347: 460-475, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35545132

RESUMO

Ultrasound insonification of microbubbles can locally enhance drug delivery by increasing the cell membrane permeability. To aid development of a safe and effective therapeutic microbubble, more insight into the microbubble-cell interaction is needed. In this in vitro study we aimed to investigate the initial 3D morphology of the endothelial cell membrane adjacent to individual microbubbles (n = 301), determine whether this morphology was affected upon binding and by the type of ligand on the microbubble, and study its influence on microbubble oscillation and the drug delivery outcome. High-resolution 3D confocal microscopy revealed that targeted microbubbles were internalized by endothelial cells, while this was not the case for non-targeted or IgG1-κ control microbubbles. The extent of internalization was ligand-dependent, since αvß3-targeted microbubbles were significantly more internalized than CD31-targeted microbubbles. Ultra-high-speed imaging (~17 Mfps) in combination with high-resolution confocal microscopy (n = 246) showed that microbubble internalization resulted in a damped microbubble oscillation upon ultrasound insonification (2 MHz, 200 kPa peak negative pressure, 10 cycles). Despite damped oscillation, the cell's susceptibility to sonoporation (as indicated by PI uptake) was increased for internalized microbubbles. Monitoring cell membrane integrity (n = 230) showed the formation of either a pore, for intracellular delivery, or a tunnel (i.e. transcellular perforation), for transcellular delivery. Internalized microbubbles caused fewer transcellular perforations and smaller pore areas than non-internalized microbubbles. In conclusion, studying microbubble-mediated drug delivery using a state-of-the-art imaging system revealed receptor-mediated microbubble internalization and its effect on microbubble oscillation and resulting membrane perforation by pores and tunnels.


Assuntos
Células Endoteliais , Microbolhas , Permeabilidade da Membrana Celular , Sistemas de Liberação de Medicamentos/métodos , Células Endoteliais/metabolismo , Ligantes
14.
Pharmaceutics ; 14(6)2022 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-35745739

RESUMO

Bacteria encased in a biofilm poses significant challenges to successful treatment, since both the immune system and antibiotics are ineffective. Sonobactericide, which uses ultrasound and microbubbles, is a potential new strategy for increasing antimicrobial effectiveness or directly killing bacteria. Several studies suggest that sonobactericide can lead to bacterial dispersion or sonoporation (i.e., cell membrane permeabilization); however, real-time observations distinguishing individual bacteria during and directly after insonification are missing. Therefore, in this study, we investigated, in real-time and at high-resolution, the effects of ultrasound-induced microbubble oscillation on Staphylococcus aureus biofilms, without or with an antibiotic (oxacillin, 1 µg/mL). Biofilms were exposed to ultrasound (2 MHz, 100-400 kPa, 100-1000 cycles, every second for 30 s) during time-lapse confocal microscopy recordings of 10 min. Bacterial responses were quantified using post hoc image analysis with particle counting. Bacterial dispersion was observed as the dominant effect over sonoporation, resulting from oscillating microbubbles. Increasing pressure and cycles both led to significantly more dispersion, with the highest pressure leading to the most biofilm removal (up to 83.7%). Antibiotic presence led to more variable treatment responses, yet did not significantly impact the therapeutic efficacy of sonobactericide, suggesting synergism is not an immediate effect. These findings elucidate the direct effects induced by sonobactericide to best utilize its potential as a biofilm treatment strategy.

15.
Circ Res ; 104(5): 679-87, 2009 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-19168443

RESUMO

Contrast microbubbles in combination with ultrasound (US) are promising vehicles for local drug and gene delivery. However, the exact mechanisms behind intracellular delivery of therapeutic compounds remain to be resolved. We hypothesized that endocytosis and pore formation are involved during US and microbubble targeted delivery (UMTD) of therapeutic compounds. Therefore, primary endothelial cells were subjected to UMTD of fluorescent dextrans (4.4 to 500 kDa) using 1 MHz pulsed US with 0.22-MPa peak-negative pressure, during 30 seconds. Fluorescence microscopy showed homogeneous distribution of 4.4- and 70-kDa dextrans through the cytosol, and localization of 155- and 500-kDa dextrans in distinct vesicles after UMTD. After ATP depletion, reduced uptake of 4.4-kDa dextran and no uptake of 500-kDa dextran was observed after UMTD. Independently inhibiting clathrin- and caveolae-mediated endocytosis, as well as macropinocytosis significantly decreased intracellular delivery of 4.4- to 500-kDa dextrans. Furthermore, 3D fluorescence microscopy demonstrated dextran vesicles (500 kDa) to colocalize with caveolin-1 and especially clathrin. Finally, after UMTD of dextran (500 kDa) into rat femoral artery endothelium in vivo, dextran molecules were again localized in vesicles that partially colocalized with caveolin-1 and clathrin. Together, these data indicated uptake of molecules via endocytosis after UMTD. In addition to triggering endocytosis, UMTD also evoked transient pore formation, as demonstrated by the influx of calcium ions and cellular release of preloaded dextrans after US and microbubble exposure. In conclusion, these data demonstrate that endocytosis is a key mechanism in UMTD besides transient pore formation, with the contribution of endocytosis being dependent on molecular size.


Assuntos
Cavéolas/metabolismo , Dextranos/metabolismo , Sistemas de Liberação de Medicamentos , Endocitose , Células Endoteliais/metabolismo , Corantes Fluorescentes/metabolismo , Microbolhas , Ultrassom , Trifosfato de Adenosina/metabolismo , Androstadienos/farmacologia , Animais , Transporte Biológico , Bovinos , Caveolina 1/metabolismo , Células Cultivadas , Clorpromazina/farmacologia , Clatrina/metabolismo , Meios de Contraste/administração & dosagem , Citosol/metabolismo , Dextranos/administração & dosagem , Dextranos/química , Endocitose/efeitos dos fármacos , Células Endoteliais/efeitos dos fármacos , Artéria Femoral/metabolismo , Filipina/farmacologia , Corantes Fluorescentes/administração & dosagem , Corantes Fluorescentes/química , Imageamento Tridimensional , Infusões Intravenosas , Microscopia de Fluorescência , Peso Molecular , Fosfolipídeos/administração & dosagem , Pinocitose , Pressão , Ratos , Ratos Wistar , Hexafluoreto de Enxofre/administração & dosagem , Fatores de Tempo , Vesículas Transportadoras/metabolismo , Wortmanina
16.
Curr Opin Chem Biol ; 63: 171-179, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34102582

RESUMO

Phospholipid-coated microbubbles are ultrasound contrast agents that, when functionalized, adhere to specific biomarkers on cells. In this concise review, we highlight recent developments in strategies for targeting the microbubbles and their use for ultrasound molecular imaging (UMI) and therapy. Recently developed novel targeting strategies include magnetic functionalization, triple targeting, and the use of several new ligands. UMI is a powerful technique for studying disease progression, diagnostic imaging, and monitoring of therapeutic responses. Targeted microbubbles (tMBs) have been used for the treatment of cardiovascular diseases and cancer, with therapeutics either coadministered or loaded onto the tMBs. Regardless of which disease was treated, the use of tMBs always resulted in a better therapeutic outcome than non-tMBs when compared in vitro or in vivo.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/tratamento farmacológico , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Fosfolipídeos/química , Animais , Meios de Contraste/química , Portadores de Fármacos/administração & dosagem , Portadores de Fármacos/química , Quimioterapia Combinada , Humanos , Microbolhas , Imagem Molecular/métodos , Terapia de Alvo Molecular , Resultado do Tratamento , Ultrassonografia
17.
J Vis Exp ; (168)2021 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-33645558

RESUMO

The chicken embryo and the blood-vessel rich chorioallantoic membrane (CAM) is a valuable in vivo model to investigate biomedical processes, new ultrasound pulsing schemes, or novel transducers for contrast-enhanced ultrasound imaging and microbubble-mediated drug delivery. The reasons for this are the accessibility of the embryo and vessel network of the CAM as well as the low costs of the model. An important step to get access to the embryo and CAM vessels is to take the egg content out of the eggshell. In this protocol, three methods for taking the content out of the eggshell between day 5 and 8 of incubation are described thus allowing the embryos to develop inside the eggshell up to these days. The described methods only require simple tools and equipment and yield a higher survival success rate of 90% for 5-day, 75% for 6-day, 50% for 7-day, and 60% for 8-day old incubated eggs in comparison to ex ovo cultured embryos (~50%). The protocol also describes how to inject cavitation nuclei, such as microbubbles, into the CAM vascular system, how to separate the membrane containing the embryo and CAM from the rest of the egg content for optically transparent studies, and how to use the chicken embryo and CAM in a variety of short-term ultrasound experiments. The in vivo chicken embryo and CAM model is extremely relevant to investigate novel imaging protocols, ultrasound contrast agents, and ultrasound pulsing schemes for contrast-enhanced ultrasound imaging, and to unravel the mechanisms of ultrasound-mediated drug delivery.


Assuntos
Membrana Corioalantoide/química , Meios de Contraste , Sistemas de Liberação de Medicamentos , Endotélio Vascular/diagnóstico por imagem , Microbolhas , Propídio/administração & dosagem , Ultrassonografia/métodos , Animais , Embrião de Galinha , Galinhas , Corantes/administração & dosagem , Casca de Ovo/química , Endotélio Vascular/efeitos dos fármacos
18.
Artigo em Inglês | MEDLINE | ID: mdl-33687842

RESUMO

In the above article [1], the authors regret that there was a mistake in calculating the mol% of the microbubble coating composition. For all experiments, the unit in mg/mL was utilized and the conversion mistake only came when converting to mol% in order to define the ratio between the coating formulation components. The correct molecular weight of PEG-40 stearate is 2046.54 g/mol [2], [3], not 328.53 g/mol. On page 1661, paragraph II-A, it should read "The coating was composed of DSPC (84.8 mol%; P 6517; Sigma-Aldrich, Zwijndrecht, The Netherlands);PEG-40 stearate (8.2 mol%; P 3440; Sigma-Aldrich); DSPE-PEG(2000) (5.9 mol%; 880125 P; Avanti Polar Lipids, Alabaster, AL, USA); and DSPE-PEG(2000)-biotin (1.1 mol%; 880129 C; Avanti Polar Lipids)".

19.
Artigo em Inglês | MEDLINE | ID: mdl-33687841

RESUMO

In the above article [1], the authors regret that there was a mistake in calculating the mol% of the microbubble coating composition. For all experiments, the unit in mg/mL was utilized and the conversion mistake only came when converting to mol% in order to define the ratio between the coating formulation components. The correct molecular weight of PEG-40 stearate is 2046.54 g/mol [2], [3], not 328.53 g/mol. On page 786, paragraph II-A, it should read "The coating was composed of 84.8 mol% DSPC (P6517, Sigma-Aldrich, Zwijndrecht, The Netherlands) or DPPC (850355, Avanti Polar Lipids, Alabaster, AL, USA); 8.2 mol% polyoxyethylene-40-stearate (PEG-40 stearate, P3440, Sigma-Aldrich); 5.9 mol% 1,2-distearoyl-sn-glycero-3-phosphoethanolamine-N-[carboxy(polyethylene glycol)-2000] (DSPE-PEG(2000), 880125, Avanti Polar Lipids); and 1.1 mol% 1,2-distearoyl-sn-glycero-3-phosphoethanolamine-N-[biotinyl(polyethylene glycol)-2000] (DSPE-PEG(2000)-biotin, 880129, Avanti Polar Lipids)."

20.
Pharmaceutics ; 13(1)2021 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-33477843

RESUMO

Phospholipid-coated microbubbles are ultrasound contrast agents that can be employed for ultrasound molecular imaging and drug delivery. For safe and effective implementation, microbubbles must respond uniformly and predictably to ultrasound. Therefore, we investigated how lipid handling and phase distribution affected the variability in the acoustic behavior of microbubbles. Cholesterol was used to modify the lateral molecular packing of 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC)-based microbubbles. To assess the effect of lipid handling, microbubbles were produced by a direct method, i.e., lipids directly dispersed in an aqueous medium or indirect method, i.e., lipids first dissolved in an organic solvent. The lipid phase and ligand distribution in the microbubble coating were investigated using confocal microscopy, and the acoustic response was recorded with the Brandaris 128 ultra-high-speed camera. In microbubbles with 12 mol% cholesterol, the lipids were miscible and all in the same phase, which resulted in more buckle formation, lower shell elasticity and higher shell viscosity. Indirect DSPC microbubbles had a more uniform response to ultrasound than direct DSPC and indirect DSPC-cholesterol microbubbles. The difference in lipid handling between direct and indirect DSPC microbubbles significantly affected the acoustic behavior. Indirect DSPC microbubbles are the most promising candidate for ultrasound molecular imaging and drug delivery applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA