Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 85(3): 440-7, 2015 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-24975883

RESUMO

OBJECTIVES: We aimed at identifying predictors of renal impairment and its impact on long-term outcome after transcatheter aortic valve implantation (TAVI). BACKGROUND: Renal impairment is common in mostly elderly, multimorbid patients undergoing TAVI. The risk of periprocedural renal function impairment and its association with outcome is incompletely understood. METHODS: In 458 consecutive patients (mean age, 80.6 ± 7.0 years, 52.2% women) who underwent routine TAVI procedures, we assessed estimated glomerular filtration rate (eGFR) at baseline, during 72-hr postprocedure and at discharge. Over a median follow-up of 0.96 years, we observed 142 deaths. RESULTS: In multivariable-adjusted models, predictors of renal function deterioration within 72 hr were baseline eGFR (ß = 0.83, 95% confidence interval [CI] = 0.76/0.91; P < 0.0001), body mass index (ß = -1.20, 95% CI = 1.77/-0.62; P < 0.0001), and major access site complications (ß = -14.82, 95% CI = -26.52/-3.11; P = 0.013) including bleeding (ß = -11.97, 95% CI = -21.05/-2.89; P = 0.0099). Strongest renal function predictor of 1-year mortality in risk factor adjusted analyses was the change of eGFR within 72 hr (odds ratio, 0.97; 95% CI = 0.96/0.98; P < 0.0001). The addition of information on the change of eGFR increased the C-statistic of the logistic EuroSCORE (P = 0.021). CONCLUSIONS: In our routine TAVI sample, baseline eGFR, body mass index, and major access site complications mainly owing to bleeding were correlates of acute kidney injury after TAVI. Acute renal impairment was a risk factor for mortality and adverse cardiovascular events which provided risk information beyond the EuroSCORE.


Assuntos
Injúria Renal Aguda/mortalidade , Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/mortalidade , Implante de Prótese de Valva Cardíaca/mortalidade , Nefropatias/mortalidade , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Índice de Massa Corporal , Cateterismo Cardíaco/efeitos adversos , Feminino , Taxa de Filtração Glomerular , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemorragia/mortalidade , Humanos , Estimativa de Kaplan-Meier , Rim/fisiopatologia , Nefropatias/diagnóstico , Nefropatias/fisiopatologia , Modelos Lineares , Masculino , Análise Multivariada , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 85(3): 460-7, 2015 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-25292388

RESUMO

OBJECTIVES: We sought to evaluate the relationship of blood transfusion after transcatheter aortic valve implantation (TAVI) and mid-term outcome to improve patient selection and periprocedural treatment. BACKGROUND: Increasing evidence suggests a negative influence of blood transfusion on outcomes of patients with cardiovascular diseases. While the adverse impact of bleeding events on survival has been documented after TAVI, data on the impact of postoperative blood transfusions are scarce. METHODS: TAVI was performed in 700 consecutive patients; 14.7% of TAVI patients suffered from bleeding or access site complications and were excluded from analysis to minimize confounding. Outcomes were analyzed with emphasis on blood transfusions and according to the Valve Academic Research Consortium definitions. Median follow-up duration was 364 days. Multivariable analyses were performed to identify predictors for transfusion and 1-year mortality. RESULTS: 33.0% of patients received blood transfusions after TAVI, irrespective of access choice. Blood transfusions were associated with a higher baseline risk profile (median logistic EuroSCORE 21.0 vs. 17.0%), increased rates of postoperative complications and impaired survival (21.2 vs. 36.1% all-cause 1-year mortality). Transfusion was an independent predictor of mortality at 1 year (OR 2.78 [CI 1.59-4.86]). Low body mass index (OR 0.94 [0.89-1.0]), low baseline hemoglobin (OR 0.39 [0.33-0.47]) and combined anticoagulation/antiplatelet therapy were identified as independent predictors of blood transfusion after TAVI. CONCLUSIONS: Blood transfusions were frequently required after TAVI even in the absence of overt bleeding or access site complications and were identified as an independent predictor of impaired mid-term outcome. Optimization of baseline factors, strict blood conservation strategies, and individualized antiplatelet or anticoagulant regimens may improve outcome after TAVI.


Assuntos
Valva Aórtica , Cateterismo Cardíaco/efeitos adversos , Doenças das Valvas Cardíacas/terapia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemorragia/terapia , Reação Transfusional , Idoso , Idoso de 80 Anos ou mais , Transfusão de Sangue/mortalidade , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidade , Feminino , Alemanha , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/mortalidade , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemorragia/diagnóstico , Hemorragia/etiologia , Hemorragia/mortalidade , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Seleção de Pacientes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 84(3): 486-93, 2014 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-24753352

RESUMO

BACKGROUND: Transcatheter valve-in-valve (VIV) implantation has emerged as a novel treatment option in patients with degenerated aortic bioprostheses and high surgical risk. However, VIV implantation in small aortic bioprostheses using first generation TAVI devices has frequently resulted in high postprocedural gradients and small effective orifice areas. Recently, an updated version of the self-expandable Medtronic CoreValve prosthesis, which is particularly suitable for small aortic annuli, has become available. We report on the feasibility and early results of VIV implantation using this novel device in a series of patients with degenerated small aortic bioprostheses. METHODS AND RESULTS: 16 patients from two Hamburg hospitals (age range 72-92 years) underwent implantation of a 23-mm CoreValve Evolut (Medtronic, Minneapolis, MN, USA) transcatheter heart valve into failing aortic bioprostheses with internal diameters below 21 mm. All patients were considered high risk for surgical aortic valve replacement after evaluation by an interdisciplinary heart team mean (logistic EuroSCORE range 9.0-88%). Implantation was successful without relevant remaining aortic regurgitation or signs of stenosis and a marked reduction in postprocedural gradientswas observed in 14 out of 16 patients. The mean gradient was reduced from from 34 mm Hg (SEM 10 mm Hg) to 14 mm Hg (SEM 6 mm Hg). No major device- or procedure-related adverse events occurred during 30-day follow up and clinical improvement was observed. CONCLUSIONS: Failing aortic bioprostheses with small internal diameters continue to be a challenging pathology for TAVI due to the risk of high residual gradients and small aortic orifice areas. This report provides first evidence that the 23-mm CoreValve Evolut, a novel self-expanding prosthesis, provides an improved treatment option in these specific patients due to its low profile which resulted in promising early results. © 2013 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 82(4): 640-52, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-23172652

RESUMO

OBJECTIVES: We report the results of a large single-center study evaluating predictors and outcomes after transcatheter aortic valve implantation (TAVI) with different devices and access routes according to the Valve Academic Research Consortium (VARC). BACKGROUND: The widespread adoption of TAVI warrants a systematic analysis of outcomes. Only few comprehensive data exist comparing different approaches as selected by a heart team. METHODS: TAVI was performed in 326 consecutive patients (mean age 80.6 ± 7.1 years, 55.5% female) at high risk for surgery with balloon-expandable and self-expanding devices through transfemoral or transapical access. Data were analyzed according to VARC endpoints; predictors of mortality were identified. RESULTS: All-cause mortality was 10.1% (30 days) and 29.9% (1 year) overall and comparable with regard to valve or access choice (P = 0.295) despite different risk profiles at baseline. Device success and 30-day safety endpoints were achieved in 87.1 and 21.2%. Myocardial infarction [hazard ratio (HR) 6.52], stage-2 and -3 acute kidney injury (HR 2.52 and 6.80) and major access site complications (HR 1.96) were independent predictors of 1-year all-cause mortality. Device success had a protective effect (HR 0.58). Baseline predictors included body mass index <20 kg/m(2) (HR 3.20), NYHA class IV (HR 1.87), left ventricular ejection-fraction <30% (HR 2.30), higher STS-PROM scores (HR 1.05 per percent), and age (group 75-85 years, HR 0.47). CONCLUSIONS: Comparable results were achieved with different devices and access routes in a heart team approach. Baseline and perioperative predictors of all-cause mortality were identified, contributing to the refinement of patient and device selection criteria for TAVI.


Assuntos
Valva Aórtica , Cateterismo Cardíaco , Doenças das Valvas Cardíacas/terapia , Implante de Prótese de Valva Cardíaca/métodos , Injúria Renal Aguda/mortalidade , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Competência Clínica , Feminino , Alemanha , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Curva de Aprendizado , Masculino , Análise Multivariada , Infarto do Miocárdio/mortalidade , Seleção de Pacientes , Modelos de Riscos Proporcionais , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
5.
J Heart Valve Dis ; 22(6): 789-93, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24597399

RESUMO

BACKGROUND AND AIM OF THE STUDY: Female gender has recently been suggested to predict a beneficial outcome and lower mortality following transcatheter aortic valve implantation (TAVI). The study aim was to address gender differences in outcome following TAVI and potentially to replicate these findings. METHODS: The present single-center prospective registry of 326 patients with severe aortic stenosis treated by TAVI between 2008 and 2011 consisted of 181 women and 145 men. RESULTS: The procedural risk was not significantly different between men and women at baseline. For all-cause mortality no difference was observed at 30 days and at 12 months after TAVI. CONCLUSION: While several baseline characteristics between men and women treated by TAVI were shown to be different among the study population, no difference was observed in survival between both genders.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Feminino , Alemanha , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Resultado do Tratamento
6.
Eur Heart J ; 31(11): 1373-81, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20219746

RESUMO

AIMS: We sought to assess the feasibility of catheter-based mitral valve repair using the MitraClip system in high-surgical-risk patients with mitral regurgitation (MR) > or =grade 3+. METHODS AND RESULTS: MitraClip therapy was performed in 51 consecutive patients [73 +/- 10 years; 34 (67%) men] with symptomatic functional [n = 35 (69%)] or organic MR [n = 16 (31%)]. Mean logistic EuroSCORE was 29 +/- 22%; Society of Thoracic Surgeons score was 15 +/- 11. Left ventricular (LV) ejection fraction was 36 +/- 17%. In 35 patients (69%), adverse mitral valve morphology and/or severe LV dysfunction were present. MitraClip implantation was successful in 49 patients (96%). Most patients [n = 34/49 (69%)] were treated with a single clip, whereas 14 patients (29%) received two clips and one patient received three clips. Mean device and fluoroscopy times were 105 +/- 65 min and 44 +/- 28 min, respectively. Procedure-related reduction in MR severity was one grade in 16 patients (31%), two grades in 24 patients (47%), and three grades in 9 patients (18%). Forty-four of the 49 successfully treated patients (90%) showed clinical improvement at discharge [NYHA functional class > or =III in 48 patients (98%) before and 16 patients (33%) after the procedure (P < 0.0001)]. There were no procedure-related major adverse events and no in-hospital mortality. CONCLUSION: Mitral valve repair using the MitraClip system was shown to be feasible in patients at high surgical risk primarily determined by an adverse mitral valve morphology and/or severe LV dysfunction.


Assuntos
Anuloplastia da Valva Mitral/instrumentação , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Complicações Pós-Operatórias/etiologia , Instrumentos Cirúrgicos , Disfunção Ventricular Esquerda/cirurgia , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/patologia , Insuficiência da Valva Mitral/patologia , Insuficiência da Valva Mitral/fisiopatologia , Fatores de Risco , Disfunção Ventricular Esquerda/patologia , Disfunção Ventricular Esquerda/fisiopatologia
7.
Catheter Cardiovasc Interv ; 71(4): 553-8, 2008 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-18307231

RESUMO

BACKGROUND: Air embolism in patients undergoing percutaneous interventions requiring access to the left atrium (LA) represents a potentially fatal complication. Here we tested if a decline in LA pressures following sedation represents an important mechanistic link underlying air intrusion into the LA. METHODS AND RESULTS: Left atrial pressures were measured in 26 consecutive patients (49 +/- 14 years; 27% male), who underwent percutaneous atrial septal occlusion for persistent foramen ovale or secundum atrial septal defects. Patients either received sedation by propofol allowing for guidance by transesophageal echocardiography (n = 13) or underwent occluder implantation without sedation and under fluoroscopic control only (n = 13). Whereas mean expiratory LA pressures remained unchanged in either group, sedation provoked a marked decline in the mean inspiratory LA pressure as compared to non-sedated patients (Delta p 6.9 +/- 8.6 mm Hg vs. 0.1 +/- 1.2 mm Hg in nonsedated patients, P < 0.001). Ex vivo experiments evaluating the air-tightness of different sheaths in response to negative pressures revealed air aspiration at -13.4 +/- 1.2 mm Hg of suction in all cases, once a guide wire was inserted. CONCLUSIONS: Negative LA pressures in conjunction with air-leaking sheaths are identified as potentially important factors for air intrusion into the LA with the patient's sedation being a primary risk factor to lower LA pressure levels. The results advocate close monitoring of LA pressures during intervention, prevention of airway collapse and protection of LA sheaths from communication with the atmosphere, during procedures under sedation.


Assuntos
Função do Átrio Esquerdo/efeitos dos fármacos , Cateterismo Cardíaco/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Embolia Aérea/etiologia , Forame Oval Patente/cirurgia , Comunicação Interatrial/cirurgia , Hipnóticos e Sedativos/efeitos adversos , Propofol/efeitos adversos , Adulto , Cateterismo Cardíaco/instrumentação , Procedimentos Cirúrgicos Cardíacos/instrumentação , Eletrocardiografia , Embolia Aérea/fisiopatologia , Desenho de Equipamento , Feminino , Átrios do Coração/fisiopatologia , Humanos , Inalação/efeitos dos fármacos , Masculino , Pessoa de Meia-Idade , Pressão , Fatores de Risco
8.
Clin Cardiol ; 30(1): 19-24, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17262773

RESUMO

BACKGROUND: Successful prevention of aortic complications has lead to improved survival of Marfan syndrome (MFS). With increasing age, however, ventricular arrhythmia and heart failure are emerging as life-threatening manifestations of myocardial dysfunction. HYPOTHESIS: We sought to investigate whether echocardiography with tissue Doppler imaging (TDI) identifies myocardial dysfunction in adults with MFS. METHODS: We performed two-dimensional (2-D) and Doppler echocardiography with TDI in 141 individuals with suspected MFS and competent heart valves, including 28 persons with MFS who had not undergone surgery and 86 healthy controls without inherited connective tissue disorders. RESULTS: Demographic profile, 2-D, mitral and pulmonary venous flow indices, and left ventricular ejection fractions were similar in both groups. Conversely, isovolumic relaxation time (p < 0.001) and deceleration time of E velocity (p = 0.005) were longer, and atrial reversal velocities (p = 0.02), and systolic and early diastolic TD velocities were slower in MFS than in controls (p = 0.01). Multiple linear regression analysis excluded association of reduced systolic and early diastolic TD velocities with mitral valve prolapse or other clinical or echocardiographic features of MFS. CONCLUSIONS: Our study identifies reduced systolic and early diastolic TD velocities in adults with MFS. Further studies are mandatory to elucidate whether TD velocities predict arrhythmia and heart failure in MFS.


Assuntos
Cardiopatias/complicações , Cardiopatias/diagnóstico por imagem , Síndrome de Marfan/complicações , Adulto , Velocidade do Fluxo Sanguíneo , Diástole/fisiologia , Ecocardiografia Doppler , Feminino , Cardiopatias/fisiopatologia , Humanos , Masculino , Síndrome de Marfan/fisiopatologia , Pessoa de Meia-Idade , Sístole/fisiologia
9.
Cardiovasc Diagn Ther ; 7(4): 367-379, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28890873

RESUMO

BACKGROUND: Transthoracic echocardiography (TTE) is the standard procedure to distinguish tricuspid aortic valve (TAV) from bicuspid aortic valve (BAV). Published studies assessed the accuracy of TTE for BAV under ideal conditions. Conversely, we aimed at assessing accuracy of TTE for BAV under routine conditions. METHODS: This retrospective, cross-sectional study of 216 adults included 132 men aged 62±14 years. Of these, 108 had BAV and 108 were age-matched individuals with TAV. All diagnoses were confirmed at surgery. We assessed TTE in two patient groups. First, in the (I) group of all 216 individuals, where we assessed accuracy for BAV according to the original diagnoses as documented by the primary investigators during original TTE examination. Second, we assessed accuracy for BAV according to expert re-evaluation in (II) all 158 TTE with availability of original recordings. Third, we performed a meta-analysis of published results on the accuracy of TTE for BAV according to PRISMA standards. RESULTS: Sensitivity, specificity and accuracy of (I) primary investigators was 46.3%, 97.2, and 71.8% as compared to (II) expert re-evaluation with 59.7%, 93%, and 77.8%, respectively. Sensitivity was significantly higher at re-evaluation (P<0.001). TTE at a non-tertiary care center (P=0.012), presence of aortic aneurysm (P=0.001) and presence of severe aortic valve calcification (P=0.003) predicted an inaccurate diagnosis of BAV. Conversely, meta-analysis of published TTE studies identified a pooled sensitivity of 87.7% and a pooled specificity of 88.3% for BAV. CONCLUSIONS: The current study shows that TTE yields almost ideal diagnostic accuracy when ideal investigators examine ideal patients. However, the study also shows that TTE yields suboptimal diagnostic accuracy under routine conditions. TTE in non-tertiary care settings, concomitant aortic aneurysm, and presence of severe aortic valve calcification predict an inaccurate diagnosis of BAV.

10.
Circulation ; 112(9 Suppl): I260-4, 2005 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-16159828

RESUMO

BACKGROUND: Despite growing interest in stent-graft implantation for type-B aortic dissection, there are no established recommendations to prepare and perform an implantation procedure. METHODS AND RESULTS: We directly compared angiography (ANGIO), transesophageal echocardiography (TEE), and intravascular ultrasound (IVUS) intraprocedually before and after placement of 48 stent grafts in 42 consecutive patients (12 women, 61+/-11 years of age) with acute and chronic type-B aortic dissection for both usefulness and capability to guide aortic stent-graft implantation. Both IVUS and TEE are superior to ANGIO to identify multiple entries (52 and 43 versus 34; P<0.005 each), to diagnose false-lumen slow flow after stent-graft implantation (32 and 31 versus 24; P<0.005 each) and to detect incomplete stent apposition (18 and 16 versus 8; P<0.005 each). In comparison with ANGIO, guide wire position over the entire length of the aorta was documented more frequently by TEE and IVUS (40 and 42 versus 25; P<0.001 each). In 4 patients with abdominal extension of the dissection, only IVUS was able to accurately identify the false lumen over the entire length of the diseased aorta. TEE was superior to IVUS and ANGIO in the detection of endoleaks (5 versus 0 and 1; P<0.05 each). Intraprocedural ANGIO, TEE, and IVUS had been performed without complications in all patients. CONCLUSIONS: TEE in conjunction with ANGIO appears to be advantageous and adds incremental information to safely guide stent-graft placement in type-B aortic dissection. Additional use of IVUS was found to be helpful in patients with complex anatomy and abdominal extension of the dissection.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Aortografia , Implante de Prótese Vascular/métodos , Ecocardiografia Transesofagiana , Radiografia Intervencionista , Stents , Ultrassonografia de Intervenção , Idoso , Dissecção Aórtica/classificação , Dissecção Aórtica/diagnóstico por imagem , Aneurisma Aórtico/classificação , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma da Aorta Abdominal/classificação , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/classificação , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Cateterismo Cardíaco , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polietilenotereftalatos , Estudos Retrospectivos
11.
Int J Cardiol Heart Vasc ; 10: 39-46, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28616514

RESUMO

BACKGROUND: Mitral valve prolapse syndrome (MVPS) and MASS phenotype (MASS) are Marfan-like syndromes that exhibit aortic dilatation and mitral valve prolapse. Unlike in Marfan syndrome (MFS), the presence of ectopia lentis and aortic aneurysm preclude diagnosis of MVPS and MASS. However, it is unclear whether aortic dilatation and mitral valve prolapse remain stable in MVPS or MASS or whether they progress like in MFS. METHODS: This retrospective longitudinal observational study examines clinical characteristics and long-term prognosis of 44 adults with MVPS or MASS (18 men, 26 women aged 38 ± 17 years) as compared with 81 adults with Marfan syndrome (MFS) with similar age and sex distribution. The age at final contact was 42 ± 15 years with mean follow-up of 66 ± 49 months. RESULTS: At baseline, ectopia lentis and aortic sinus aneurysm were absent in MVPS and MASS, and systemic scores defined by the revised Ghent nosology were lower than in MFS (all P < .001). Unlike in MFS, no individual with MVPS and MASS developed aortic complications (P < .001). In contrast, the incidence of endocarditis (P = .292), heart failure (P = .644), and mitral valve surgery (P = .140) was similar in all syndromes. Cox regression analysis identified increased LV end-diastolic (P = .013), moderate MVR (P = .019) and flail MV leaflet (P = .017) as independent predictors of mitral valve surgery. CONCLUSIONS: The study provides evidence that MVPS and MASS are Marfan-like syndromes with stability of aortic dilatation but with progression of mitral valve prolapse. Echocardiographic characteristics of mitral valve disease rather than the type of syndrome, predict clinical progression of mitral valve prolapse.

12.
13.
J Am Coll Cardiol ; 39(4): 617-24, 2002 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-11849860

RESUMO

OBJECTIVES: We sought to identify the predictors of aneurysmal formation after surgical correction of aortic coarctation. BACKGROUND: In 9% of patients, aneurysms develop late after corrective surgery of coarctation of the aorta, with a 36% mortality rate if left untreated. However, the predictors of postsurgical aneurysmal formation are unknown. METHODS: Of 25 aortic aneurysms requiring corrective surgery 152 +/- 78 months after the initial coarctation repair, 8 were located in the ascending aorta (type A) and 17 at the site of previous repair (local type). Seventy-four patients without progression of the aortic diameter within 189 +/- 71 months after coarctation repair were used for categorical data analysis in an attempt to identify the predictors of postsurgical aneurysmal formation. RESULTS: Advanced age at coarctation repair (p = 0.004) and patch graft technique (p < 0.0005) independently predicted local aneurysmal formation. Type A aneurysm was univariately associated with the presence of a bicuspid aortic valve (p = 0.02), advanced age at coarctation repair (p = 0.044) and a high preoperative peak systolic pressure gradient of 74 +/- 21 mm Hg (p = 0.041). Conversely, multivariate analysis confirmed only the presence of a bicuspid aortic valve (p = 0.015) as an independent predictor of type A aneurysm. Receiver operating characteristic curve analysis revealed that 72% of patients with a postsurgical aneurysm had an operation at age 13.5 years or more, whereas 69% with no postsurgical aneurysm had an operation at a younger age. CONCLUSIONS: Use of the patch graft technique and late correction of coarctation can predict aneurysmal formation at the site of coarctation repair, although patients with a bicuspid aortic valve may be at risk for an aneurysm developing in the ascending aorta, particularly after late repair of aortic coarctation with high preoperative pressure gradients.


Assuntos
Aneurisma Aórtico/etiologia , Coartação Aórtica/complicações , Coartação Aórtica/cirurgia , Modelos Estatísticos , Complicações Pós-Operatórias , Adolescente , Adulto , Aorta/anormalidades , Aorta/cirurgia , Aorta Torácica/anormalidades , Aorta Torácica/cirurgia , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
14.
EuroIntervention ; 11(7): 785-92, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25983028

RESUMO

AIMS: Transcatheter aortic valve therapy has become an established procedure for patients at high risk for surgical valve replacement. The BIOVALVE-I study aims to assess the safety and performance of a novel self-expanding transcatheter heart valve. METHODS AND RESULTS: In this prospective, single-centre, first-in-human study, 13 patients with severe aortic stenosis suitable for transfemoral transcatheter aortic valve implantation were enrolled. Mean logistic EuroSCORE was 14.4±3.7% and mean STS PROM score was 4.3±1.6%. The primary endpoint, 30-day early safety composite per VARC-2, was observed in two patients (15.4%, one life-threatening bleeding and one valve-in-valve procedure). The implant was aborted in two patients due to unsuitable aortic anatomy. Overall, device success was obtained in nine patients (69.2%, two aborted implants, one valve-in-valve procedure and one patient with moderate aortic regurgitation). As determined by an independent core laboratory, all but one patient had less than moderate total aortic regurgitation at 30-day follow-up, mean aortic gradient was 6.7±2.3 mmHg and effective orifice area 1.8±0.3 cm. Pacemakers were implanted in three patients (23.1%), and no death, stroke, myocardial infarction or acute kidney failure was observed. CONCLUSIONS: In this first-in-human study, the feasibility of implantation of the BIOVALVE system and its re-sheathing functionality was demonstrated, and short-term safety data were encouraging. Larger studies are required to confirm the performance of the device.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/métodos , Angiografia Coronária , Estudos de Viabilidade , Feminino , Alemanha , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
15.
Eur J Cardiothorac Surg ; 47(1): 39-45; discussion 45, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24578405

RESUMO

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) has become an established procedure in patients with aortic stenosis and high surgical risk. Experience with first-generation transcatheter heart valves (THVs) is broad but limitations, e.g. paravalvular regurgitation, have been demonstrated. Much hope rests on the recently Conformité Européenne mark approved next-generation devices to improve results in these patients. However, apart from the initial approval studies, clinical data with these new devices are still scarce. We aimed to assess short-term outcomes of 200 consecutive patients who underwent transapical TAVI with next-generation THV at our institution. METHODS: Transapical TAVI was performed in 200 consecutive patients 80.5±6.7 years old (38.5% female) at high surgical risk (log EuroSCORE 20.2±16.5%). Devices implanted were the Engager (Medtronic, Inc., Minneapolis, MN, USA; n=50), JenaValve (JenaValve Technology, Munich, Germany; n=88) and Symetis Acurate (Symetis SA, Ecublens, Switzerland; n=62) THV that were selected by the heart team on an individual basis. Data at baseline, during the procedure and follow-up were analysed according to standardized Valve Academic Research Consortium end points. Median follow-up was 219 days. RESULTS: Implantation was successful in 96.5% of cases. Valve function improved significantly with an increase in effective orifice area from 0.8±0.4 to 1.8±0.3 cm2 and a reduction in mean transvalvalvular gradients from 34.0±17.0 to 11.2±5.4 mmHg. Paravalvular regurgitation was none or trace in 70.3% of patients, Grade 1 in 26.1%, and Grade 2 in 3.5%. No patients developed aortic regurgitation>Grade 2. Major access site complications occurred in 6.5%, major stroke in 1.5% and stage-3 kidney injury in 2.5% of patients. A permanent pacemaker was implanted in 20.5% of patients overall and in 8.0% for a complete heart block. At 30-day follow-up 72.8% of patients were in New York Heart Association class I or II (10.5% at baseline). Overall survival was 91.5% at 30 days and 73.9% at 1 year. CONCLUSIONS: In a real-world clinical setting, next-generation transapical THV yielded positive haemodynamic results. The incidence of relevant paravalvular regurgitation was scarce in this group and clinical outcomes were encouraging during short-term follow-up. Long-term follow-up is required to investigate the durability of these new devices.


Assuntos
Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
16.
J Am Soc Echocardiogr ; 17(11): 1173-8, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15502792

RESUMO

Background Three-dimensional color Doppler echocardiography has been used to assess cardiac blood flow in experimental settings. We tested whether this technique can be applied to assess transatrial shunt flow in patients with atrial septal defect in a clinical setting. Methods In 46 consecutive patients with atrial septal defects, shunt flow was assessed during cardiac catheterization using the Fick method and by conventional 2-D quantitative transesophageal Doppler echocardiography. The averaged values for shunt flow obtained by both methods were used as a reference. Transesophageal 3-D color Doppler echocardiography was performed for analysis of the 3-D flow velocity field of transatrial shunt flow. Shunt volume was calculated by application of the Gauss theorem. Results We found a close correlation between shunt volume (L/min) obtained by either 3-D color Doppler echocardiography or the reference methods ( r = 0.981, P < .001). Using 3-D color Doppler data to predict the reference values, 95% confidence limits were -11.5 to +11.6%. Conclusions Shunt flow in patients with atrial septal defects can be assessed in a clinical setting by transesophageal 3-D color Doppler echocardiography.


Assuntos
Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Comunicação Interatrial/diagnóstico por imagem , Adolescente , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Ecocardiografia Tridimensional , Feminino , Comunicação Interatrial/fisiopatologia , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade
17.
Eur J Cardiothorac Surg ; 46(1): 61-6, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24335266

RESUMO

OBJECTIVES: Currently, preimplant balloon aortic valvuloplasty (BAV) is considered a prerequisite for successful subsequent transapical transcatheter aortic valve implantation (TA-TAVI) using balloon-expandable devices. However, cerebral embolization has been shown to originate at least in part from BAV procedures. Omitting BAV may therefore reduce neurological events after TAVI and facilitate the procedure while yielding non-inferior haemodynamic and clinical outcomes. METHODS: From May 2011 through December 2012, a total of 50 consecutive patients were treated by TA-TAVI without preimplant BAV (TA-TAVI(-BAV), study group) using the Edwards Sapien XT device (54% male, age 78 ± 8 years, logistic European System for Cardiac Operative Risk Evaluation I 21 ± 14%). Data were prospectively entered into a dedicated database, retrospectively analysed and compared with a consecutive series of conventional TA-TAVI using the same device (control group, n = 50). Reporting of data followed Valve Academic Research Consortium definitions. RESULTS: Overall device success rate was 94% (47/50) and 86% (43/50) in study and control groups, respectively (P = 0.32). Procedure time was similar in the study group compared with the control group (88 ± 31 vs 91 ± 25 min, P = 0.60), while significantly less contrast was used (138 ± 68 vs 183 ± 78 ml, P < 0.001). Post-procedural peak and mean transvalvular gradients were 16 ± 7 and 8 ± 3 mmHg, respectively, in the study group with similar values in the control group (19 ± 9 and 9 ± 5 mmHg, P = 0.08 and P = 0.09, respectively). Residual paravalvular leakage (PVL) grade 2 was present in 2 and 8% in study and control groups, respectively (P = 0.36), with no PVL >grade 2 in any patient. Rates of 30-day mortality and periprocedural stroke were 4 and 10% (P = 0.44) and 2 and 6% (P = 0.62), respectively. CONCLUSIONS: TA-TAVI(-BAV) is feasible and safe and has become ur default technique for patients allocated to TA-TAVI with balloon-expandable devices. This approach resulted in less contrast agent used and facilitated the procedure without compromising valve performance. Possible beneficial effects of this approach on the incidence of cerebrovascular events, other periprocedural complications or haemodynamic valve performance need to be verified in larger patient numbers before general recommendations can be made.


Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão , Estudos de Casos e Controles , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Duração da Cirurgia , Cuidados Pré-Operatórios , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Ultrassonografia
18.
EuroIntervention ; 10(8): 990-4, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24647151

RESUMO

AIMS: Recently, the feasibility of valve-in-valve procedures using current first-generation transcatheter heart valves (THV) in cases of structural valve degeneration has been reported as an alternative to conventional open repeat valve replacement. By design, certain biological valve xenografts carry a high risk of coronary ostia occlusion due to lateral displacement of leaflets after valve-in-valve procedures. In the present report we aimed to prove feasibility and safety of transapical valve-in-valve implantation of the JenaValve THV in two cases of degenerated Mitroflow bioprostheses. METHODS AND RESULTS: We herein report two cases of successful transapical valve-in-valve procedures using a JenaValve THV implanted in Sorin Mitroflow bioprostheses for structural valve degeneration. Both patients were alive and in good clinical condition at 30 days from the procedure. However, increased transvalvular gradients were noted in both cases. CONCLUSIONS: Transcatheter valve-in-valve implantation of a JenaValve THV is a valid alternative for patients with degenerated Mitroflow bioprostheses of sufficient size and in the presence of short distances to the coronary ostia who are too ill for conventional repeat open heart surgery. Increased pressure gradients have to be expected and weighed against the disadvantages of other treatment options when planning such a procedure.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Desenho de Prótese , Falha de Prótese , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Estudos de Viabilidade , Humanos , Masculino
19.
Clin Res Cardiol ; 103(8): 631-40, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24643728

RESUMO

AIMS: Transcatheter aortic valve implantation (TAVI) is an increasingly common procedure in elderly and multimorbid patients with aortic stenosis. We aimed at developing a pre-procedural risk evaluation scheme beyond current surgical risk scores. METHODS: We developed a risk algorithm for 1-year mortality in two cohorts consisting of 845 patients undergoing routine TAVI procedures by commercially available devices, mean age 80.9 ± 6.5, 51 % women. Clinical variables were determined at baseline. Multivariable Cox regression related clinical data to mortality (n = 207 deaths). RESULTS: To account for variability related to age and sex and by enrolment site we forced age, sex, and cohort into the score model. Body mass index, estimated glomerular filtration rate, hemoglobin, pulmonary hypertension, mean transvalvular gradient and left ventricular ejection fraction at baseline were most strongly associated with mortality and entered the risk prediction algorithm [C-statistic 0.66, 95 % confidence interval (CI) 0.61-0.70, calibration χ (2)-statistic = 6.51; P = 0.69]. Net reclassification improvement compared to existing surgical risk predication schemes was positive. The score showed reasonable model fit and calibration in external validation in 333 patients, N = 55 deaths (C-statistic 0.60, 95 % CI 0.52-0.68; calibration χ (2)-statistic = 16.2; P = 0.06). Additional measurement of B-type natriuretic peptide and troponin I did not improve the C-statistic. Frailty increased the C-statistic to 0.71, 95 % CI 0.65-0.76. CONCLUSIONS: We present a new risk evaluation tool derived and validated in routine TAVI cohorts that predicts 1-year mortality. Biomarkers only marginally improved risk prediction. Frailty increased the discriminatory ability of the score and needs to be considered. Risk algorithms specific for TAVI may help to guide decision-making when patients are evaluated for TAVI.


Assuntos
Algoritmos , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/metabolismo , Estudos de Coortes , Feminino , Seguimentos , Idoso Fragilizado , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Avaliação de Resultados em Cuidados de Saúde , Modelos de Riscos Proporcionais , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco
20.
Orphanet J Rare Dis ; 9: 203, 2014 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-25491897

RESUMO

BACKGROUND: Echocardiographic upper normal limits of both main pulmonary artery (MPA) diameters (MPA-d) and ratio of MPA to aortic root diameter (MPA-r) are not defined in healthy adults. Accordingly, frequency of MPA dilatation based on echocardiography remains to be assessed in adults with Marfan syndrome (MFS). METHODS: We enrolled 123 normal adults (72 men, 52 women aged 42 ± 14 years) and 98 patients with MFS (42 men, 56 women aged 39 ± 14 years) in a retrospective cross-sectional observational controlled study in four tertiary care centers. We defined outcome measures including upper normal limits of MPA-d and MPA-r as 95 quantile of normal persons, MPA dilatation as diameters > upper normal limits, MPA aneurysm as diameters >4 cm, and indication for surgery as MPA diameters >6 cm. RESULTS: MPA diameters revealed normal distribution without correlation to age, sex, body weight, body height, body mass index and body surface area. The upper normal limit was 2.6 cm (95% confidence interval (CI) =2.44-2.76 cm) for MPA-d, and 1.05 (95% CI = .86-1.24) for MPA-r. MPA dilatation presented in 6 normal persons (4.9%) and in 68 MFS patients (69.4%; P < .001), MPA aneurysm presented only in MFS (15 patients; 15.3%; P < .001), and no patient required surgery. Mean MPA-r were increased in MFS (P < .001), but ratios >1.05 were equally frequent in 7 normal persons (5%) and in 8 MFS patients (10.5%; P = .161). MPA-r related to aortic root diameters (P = .042), reduced left ventricular ejection fraction (P = .006), and increased pulmonary artery systolic pressures (P = .040). No clinical manifestations of MFS and no FBN1 mutation characteristics related to MPA diameters. CONCLUSIONS: We established 2.6 cm for MPA-d and 1.05 for MPA-r as upper normal limits. MFS exhibits a high prevalence of MPA dilatation and aneurysm. However, patients may require MPA surgery only in scarce circumstances, most likely because formation of marked MPA aneurysm may require LV dysfunction and increased PASP.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Síndrome de Marfan/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Vasodilatação , Adolescente , Adulto , Idoso , Aneurisma Aórtico/fisiopatologia , Estudos Transversais , Ecocardiografia/normas , Feminino , Humanos , Masculino , Síndrome de Marfan/fisiopatologia , Pessoa de Meia-Idade , Artéria Pulmonar/fisiopatologia , Valores de Referência , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA