Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 94(1): 91-97, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30636371

RESUMO

BACKGROUND: Although bioresorbable polymer sirolimus-eluting Ultimaster stents (BP-SESs) are likely useful for percutaneous coronary interventions (PCIs), the clinical data from real-world cases are insufficient. Furthermore, the predictors of adverse clinical outcomes after BP-SES implantation have not been fully investigated. OBJECTIVES: This study evaluated the 1-year clinical outcomes after BP-SES implantation in real-world PCI cases and identified the predictors of adverse outcomes. METHODS: In this single-center, all-comers study, we consecutively implanted BP-SESs in all patients who required coronary stents between October 2015 and August 2016. We conducted a clinical follow-up assessment of these patients. RESULTS: The sample comprised 1,727 patients; 67% were men, the mean age was 72 years, and 37% had diabetes. Of the 2,085 lesions detected, 88% were type B2/C lesions, 4% were chronic total occlusions (CTOs), and 23% were bifurcations. The cumulative incidences of target lesion revascularization (TLR) and target lesion failure (TLF) at 1-year were 2.4% and 5.2%, respectively. A multivariate analysis revealed that hemodialysis (HD) (hazard ratio [HR] 8.40) and CTO (HR 4.21) were independent predictors of TLR. Stent sizes ≤2.5 mm were not associated with either TLR or TLF. CONCLUSIONS: The current study indicates that patients on HD and those with CTO were more likely to experience adverse clinical outcomes after BP-SES implantation. In contrast, small vessel diameter was not significantly related to adverse outcomes. The 1-year clinical outcomes after BP-SES implantation were found to be favorable among all-comer PCI cases, including patients receiving HD and those with in-stent restenosis.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Oclusão Coronária/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Fármacos Cardiovasculares/efeitos adversos , Doença Crônica , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/mortalidade , Feminino , Humanos , Japão , Nefropatias/mortalidade , Nefropatias/terapia , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Diálise Renal , Medição de Risco , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
2.
Heart Vessels ; 31(4): 465-73, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25630713

RESUMO

Even in the drug-eluting stent era, diabetes mellitus (DM) patients have high incidences of restenosis and repeat revascularization after percutaneous coronary intervention. The aim of this study was to compare vascular response after stent implantation between sirolimus-eluting stent (SES) and paclitaxel-eluting stent (PES) by using optical coherence tomography (OCT) in DM patients as well as in non-DM patients. In the Japan-Drug Eluting Stents Evaluation; a Randomized Trial (J-DESsERT), the OCT sub-study enrolled 75 patients who underwent 8 months follow-up imaging after SES or PES implantation. Mean neointimal hyperplasia (NIH) thickness was significantly thinner in SES than PES in the DM group (77 ± 47 vs. 201 ± 114 µm, p < 0.001) and in the non-DM group (84 ± 37 vs. 212 ± 128 µm, p < 0.001). Unevenness of NIH thickness in longitudinal axis was significantly smaller in SES than PES in the DM group (348 ± 191 vs. 726 ± 385 µm, p < 0.001) and in the non-DM group (344 ± 174 vs. 679 ± 314 µm, p < 0.001). The percentage of uncovered struts was significantly greater in SES than PES in the DM group (24 ± 4 vs. 9 ± 14 %, p < 0.001) and in the non-DM group (16 ± 16 vs. 3 ± 4 %, p = 0.002). Compared with PES, SES showed more potent NIH inhibition in DM patients as well as in non-DM patients.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Tomografia de Coerência Óptica/métodos , Grau de Desobstrução Vascular/fisiologia , Idoso , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Vasos Coronários/cirurgia , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Neointima/patologia , Estudos Prospectivos , Fatores de Tempo
3.
Heart Vessels ; 30(2): 270-3, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24408671

RESUMO

We report an autopsy case of a coronary aneurysm with massive adventitial inflammation post-percutaneous coronary intervention with sirolimus-eluting stent (SES) insertion in the left circumflex (LCX) coronary artery for ischemic heart disease 3 years prior to death. The internal elastic membrane was disrupted opposite the site of the eccentric LCX plaque due to injury during stenting, and the adventitia showed massive inflammatory cell infiltration, mainly consisting of eosinophils. The LCX showed aneurysmal dilatation with inflammatory cell infiltration. Inappropriate SES implantation attracted chronic inflammation. Chronic inflammation can lead to the development of coronary artery aneurysms.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Aneurisma Coronário/etiologia , Doença da Artéria Coronariana/terapia , Vasos Coronários/lesões , Stents Farmacológicos , Everolimo/administração & dosagem , Traumatismos Cardíacos/etiologia , Inflamação/etiologia , Intervenção Coronária Percutânea/instrumentação , Lesões do Sistema Vascular/etiologia , Idoso de 80 Anos ou mais , Autopsia , Aneurisma Coronário/diagnóstico , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Evolução Fatal , Feminino , Traumatismos Cardíacos/diagnóstico , Humanos , Inflamação/diagnóstico , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Resultado do Tratamento , Ultrassonografia de Intervenção , Lesões do Sistema Vascular/diagnóstico
4.
Circ J ; 78(1): 110-21, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24189503

RESUMO

BACKGROUND: The advantages of the final kissing balloon technique (FKB) in a provisional 1-stent approach are under debate. Long-term clinical outcomes remain unclear due to limited data. METHODS AND RESULTS: Of 2,132 patients (2,502 lesions) enrolled in the TAXUS Japan Postmarket Surveillance Study at 56 centers between July 2007 and December 2008, patients having coronary bifurcation treated with a single cross-over stenting with FKB (FKB-group: 132 patients/137 lesions) were compared to those treated without FKB (no-FKB-group: 121 patients/124 lesions). The no-FKB-group was also compared with non-bifurcation patients who had a single-stent implantation (814 patients/937 lesions). The primary outcome was MACE (major adverse clinical events), defined as cardiac death, myocardial infarction and target vessel revascularization (TVR) at 3 years. Higher late loss and binary restenosis were found in the main vessel (MV) of the FKB-group at the 9-month angiogram compared to the no-FKB-group. At 3 years, MACE was numerically higher (14.6% vs. 6.9%, P=0.07) and TVR was significantly higher (14.6% vs. 5.9%, P<0.05) in the FKB-group compared with the no-FKB-group. The rate of MACE (6.9% vs. 10.4%, P=0.34) and TVR (5.9% vs. 7.7%, P=0.57) were similar between the no-FKB and non-bifurcation patients. CONCLUSIONS: In a 1-stent approach, FKB was associated with worse angiographic outcomes in the MV, and did not demonstrate any clinical benefit over the long-term follow-up period. Cross-over stenting without FKB showed similar clinical outcomes to patients without bifurcation.


Assuntos
Angiografia Coronária , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/mortalidade , Vigilância de Produtos Comercializados , Stents , Idoso , Morte , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Taxa de Sobrevida , Fatores de Tempo
5.
Pathol Int ; 64(7): 325-35, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25047503

RESUMO

It is of importance to clarify pathophysiology of diabetic heart diseases such as heart failure and coronary artery disease. We reported a novel clinical phenotype called triglyceride deposit cardiomyovasculopathy (TGCV), showing aberrant TG accumulation in both coronary arteries and myocardium, in a cardiac transplant recipient. Here, we examined autopsied diabetics for TG deposition in cardiovasculature. Consecutive series of hearts from advanced diabetes mellitus (DM) subjects (DM group: DMG, n = 20) and those from age- and sex-matched non-diabetic controls (non DM group: NDMG, n = 20) were examined. The diagnostic criteria of 'advanced DM' was made based on 2014 Clinical Practice Recommendations proposed by the American Diabetes Association. The mean duration of DM was 15.8 years. All DMG suffered from heart diseases including coronary artery diseases and 14 subjects had multi-vessel disease. Tissue TG contents were measured biochemically. Coronary arterial TG contents was significantly higher in DMG compared with NDMG. Spatial distribution of TG in transverse sections of coronary arteries showed TG deposition mainly in smooth muscle cells by Imaging Mass Spectrometry. Abundant TG deposition in coronary artery might be associated with advanced DM.


Assuntos
Doença das Coronárias/metabolismo , Vasos Coronários/metabolismo , Complicações do Diabetes/metabolismo , Diabetes Mellitus/metabolismo , Triglicerídeos/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença das Coronárias/complicações , Doença das Coronárias/patologia , Doença das Coronárias/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Músculo Liso/patologia
6.
Heart Vessels ; 29(2): 273-7, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23595778

RESUMO

A 60-year-old man who had received repeated angioplasty for silent ischemia was suspected to have restenosis based on radioisotope imaging (exercise-RI) findings 6 months after everolimus-eluting stent (EES) implantation (3.5 × 28, 3.5 × 28, 3.0 × 18 mm). The stents had been implanted for chronic total occlusion of the right coronary artery (RCA), and the patient was on continuous dual antiplatelet therapy. Diagnostic angiography demonstrated in-stent restenosis in the proximal RCA, which was treated by optical coherence tomography (OCT)-guided cutting balloon angioplasty with distal protection. OCT findings of the stenotic segment before angioplasty showed that the lesion had complex features. The lesion was successfully dilated, and whitish material obtained by a distal protection device was composed of fibrin thrombi with neutrophils and small pieces of mature fibrocellular neointima. The mechanisms and patterns of restenosis after EES placement have not been well clarified. This case may reflect a restenosis pattern (i.e., asymptomatic, focal, and thrombi-related) in the era of the newer generation of drug-eluting stents.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Reestenose Coronária/etiologia , Trombose Coronária/etiologia , Stents Farmacológicos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Angioplastia Coronária com Balão , Angiografia Coronária , Reestenose Coronária/diagnóstico , Reestenose Coronária/terapia , Trombose Coronária/diagnóstico , Trombose Coronária/terapia , Everolimo , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Índice de Gravidade de Doença , Sirolimo/administração & dosagem , Tomografia de Coerência Óptica , Resultado do Tratamento
7.
Am Heart J ; 166(3): 527-33, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24016503

RESUMO

BACKGROUND: The aim of this study was to investigate the efficacy and safety of paclitaxel-coated balloon (PCB) for the treatment of the bare-metal stent restenosis (BMS-ISR) and drug-eluting stent restenosis (DES-ISR). METHODS: This study was a prospective, multicenter, randomized (2:1) trial conducted in 208 patients with 213 in-stent restenosis lesions (BMS-ISR: 123 lesions, DES-ISR: 90 lesions) at 13 centers in Japan. Patients were randomly assigned to a PCB group (137 patients with 142 lesions) or a conventional balloon angioplasty (BA) group (71 patients with 71 lesions). The primary end point was target vessel failure at 6-month follow-up. RESULTS: Clinical and angiographic follow-up 6 months after intervention was performed in 207 patients (99.5%) with 208 lesions (97.7%). Target vessel failure was noted in 6.6% of the PCB group and 31.0% of the BA group (P < .001). Recurrent restenosis occurred in 4.3% of the PCB group and 31.9% of the BA group (P < .001). Late lumen loss was lower in the PCB group than in the BA group (0.11 ± 0.33 mm vs 0.49 ± 0.50 mm, P < .001). In PCB-treated lesions, recurrent restenosis occurred in 1.1% of patients with BMS-ISR and in 9.1% of patients with DES-ISR (P = .04). Late lumen loss was lower in patients with BMS-ISR than in patients with DES-ISR (0.05 ± 0.28 mm vs 0.18 ± 0.38 mm, P = .03). CONCLUSIONS: This randomized clinical study suggested that PCB provided much better clinical and angiographic outcomes than did conventional BA in patients with BMS-ISR and DES-ISR. Drug-eluting stent restenosis was associated with poorer outcomes compared with BMS-ISR after treatment with PCB.


Assuntos
Angioplastia Coronária com Balão/métodos , Reestenose Coronária/terapia , Stents Farmacológicos/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Paclitaxel/uso terapêutico , Stents/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Reestenose Coronária/etiologia , Feminino , Seguimentos , Oclusão de Enxerto Vascular/etiologia , Humanos , Japão , Masculino , Metais , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
8.
Circ J ; 77(6): 1430-5, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23428716

RESUMO

BACKGROUND: Although previous randomized and non-randomized studies have demonstrated the safety and efficacy of paclitaxel-eluting stents (PES), a higher revascularization rate has been reported in women than in men. A sub-analysis of the TAXUS Japan Post-market Surveillance Study (TAXUS-PMS) was done to assess the influence of gender on clinical outcome. METHODS AND RESULTS: A total of 2,132 PES-treated Japanese patients (women, n=551) from this registry were analyzed. Subjects were stratified by gender to compare 1-year clinical outcome. PES-treated women were older and more likely to have insulin-treated diabetes and hypertension. In contrast, PES-treated men were more likely to be smokers, have a previous history of myocardial infarction, and lower ejection fraction. While cardiac death, myocardial infarction and stent thrombosis were similar between men and women, major cardiac events tended to be lower in women than in men (6.4% vs. 8.8%, P=0.08). Although women had significantly smaller reference vessel size (2.46±0.53 mm vs. 2.59±0.60 mm, P<0.0001), the restenosis rate tended to be lower in women than in men (11.5% vs. 14.8%, P=0.11). Subsequently, the target lesion revascularization rate was significantly lower in women than in men (4.2% vs. 6.5%, P<0.05). CONCLUSIONS: Despite a higher risk profile, Japanese women treated with PES did not have a higher rate of repeat revascularization or major adverse clinical outcome than PES-treated men at 1 year.


Assuntos
Antineoplásicos Fitogênicos/farmacologia , Morte , Stents Farmacológicos , Infarto do Miocárdio , Paclitaxel/farmacologia , Sistema de Registros , Idoso , Idoso de 80 Anos ou mais , Povo Asiático , Feminino , Oclusão de Enxerto Vascular , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/fisiopatologia , Vigilância de Produtos Comercializados , Ensaios Clínicos Controlados Aleatórios como Assunto , Caracteres Sexuais , Fatores Sexuais , Fatores de Tempo
9.
Cardiovasc Revasc Med ; 51: 10-17, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36804303

RESUMO

BACKGROUND: When a catheter device is delivered during percutaneous coronary intervention, its passage can be disrupted by a deployed in a coronary artery. However, the condition and details of this phenomenon, that is impeded-by-stent phenomenon (ISP), remain unclear. METHODS: We designed a prospective, open-label, single-center, observational study to clarify the incidence, predictors, and clinical impact of ISP in drug-eluting stents (DESs). Two independent operators observed and judged the occurrence of ISP, which was defined as all disturbances to a device delivery by deployed DESs. We consecutively used the Ultimaster™ (Terumo, Tokyo, Japan) DES for one month (109 patients, October 2018), followed by the Synergy™ (Boston Scientific Corporation, Marlborough, MA, USA) DES the next month (119 patients, November 2018). RESULTS: DESs (2.5-4.0 mm in diameter) were implanted in 230 de novo coronary vessels. ISPs were observed in 17 of 239 stented segments (7.1 %). Multivariate analysis showed that bifurcation lesions (adjusted odds ratio [OR], 4.2; 95 % confidence interval [CI], 1.5-12.6; p = 0.008), predilatation balloon diameter (mm) (OR, 0.2; 95 % CI, 0.1-0.9; p = 0.03), and Ultimaster™ use (OR, 6.0; 95 % CI, 1.9-27.2; p = 0.002) were independent predictors of ISPs. During the 1.5-year follow-up period, no repeat revascularization or stent thrombosis occurred in patients with ISP. CONCLUSIONS: ISP itself does not trigger notable clinical outcomes, including repeat revascularization and stent thrombosis. However, caution should be considered regarding the latent risk of procedural complications.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Trombose , Humanos , Stents Farmacológicos/efeitos adversos , Infarto do Miocárdio/etiologia , Incidência , Estudos Prospectivos , Resultado do Tratamento , Stents/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Trombose/etiologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Desenho de Prótese
10.
Cardiovasc Revasc Med ; 37: 43-49, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34266771

RESUMO

BACKGROUND: This study aimed to clarify the factors for efficient procedures (EP) in superficial femoral artery (SFA) chronic total occlusion (CTO). METHODS: We retrospectively analyzed 200 consecutive limbs that underwent treatment for SFA CTO. The patients were divided into three groups according to the main strategies: subintimal angioplasty (SIA) (n = 123), Crosser use (n = 50), and 0.014″ CTO guidewire (CTO-GW) (n = 27). To determine the factors for an EP (EP; contrast volume <130 mL and procedure time <20 min; derived from non-CTO [control] procedures), the variables (P < 0.2) underwent multivariate analysis. RESULTS: SIA included more Trans-Atlantic Inter-Society Consensus C/D lesions and contralateral femoral approaches, and additional GW use (P < 0.05). CTO-GW presented a shorter occlusion length and elapsed time, and used less retrograde approach than the other strategies (P < 0.05). Crossers had a higher incidence of perforation (P = 0.002). The prompt retrograde approach had a similar actual retrograde procedure time, but a shorter total procedure time, compared to that of the delayed adoption (P < 0.001). EP was achieved in 14 limbs (7.0%). Multivariate analysis revealed that occlusion length (adjusted odds ratio [OR], 0.89; 95% CI, 0.81-0.96; P = 0.004) and SIA (OR, 8.71; 95% CI, 1.32-175.27; P = 0.02) were associated with EP. CONCLUSIONS: SIA contributed to EP. The timing of the retrograde approach was crucial because its delay resulted in an excessive procedure time.


Assuntos
Artéria Femoral , Doença Arterial Periférica , Angioplastia/métodos , Doença Crônica , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Humanos , Extremidade Inferior , Doença Arterial Periférica/cirurgia , Doença Arterial Periférica/terapia , Estudos Retrospectivos , Resultado do Tratamento
11.
J Heart Lung Transplant ; 41(7): 877-885, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35400587

RESUMO

BACKGROUND: Detailed morphological characteristics of de novo and donor-transmitted plaques and the association of serum T-lymphocyte cytokine levels with plaque progression of coronary allograft vasculopathy within 1 year after heart transplantation are unknown. METHODS: In this retrospective analysis of data in a prospectively maintained database, 40 heart transplant recipients were included. We performed serial 3 vessel optical coherence tomography and intravascular ultrasound analyses, at the 8 week (baseline) and 12 month post-transplantation follow-ups, and serum cytokine measurements (n = 23). The correlation between serum cytokines and Δplaque burden (between baseline and follow-up) was evaluated depending on plaque morphology. RESULTS: Thirteen de novo plaques (maximum intimal thickness ≥0.5 mm at the 12 month follow-up without plaques at baseline) were identified in 8 recipients, and 31 donor-transmitted plaques (maximum intimal thickness ≥0.5 mm at baseline) were detected in 17 recipients. Compared with donor-transmitted plaques, the Δplaque burden in the de novo plaques, with mainly fibrous morphology, was high (38.8% [29.6%-41.2%] vs 8.7% [1.33%-13.6%], p < 0.001). Stratification of the morphology of donor-transmitted plaques revealed that the Δplaque burden in fibrous plaques (10.6% [7.0%-18.0%]) was similar to that in fibroatheroma (10.3% [8.7%-23.8%]). Serum interleukin-31 levels at baseline correlated with fibrous plaque proliferation (r = 0.73, p = 0.007) even under immunosuppressive conditions, whereas other cytokines (interleukin-1ß, interleukin-17, and interferon-gamma) were mostly undetectable. CONCLUSIONS: Intimal fibrous proliferation contributed to the progression of donor-transmitted and de novo plaques. Serum interleukin-31 levels at baseline may contribute to intimal fibrous proliferation within 1 year after heart transplantation.


Assuntos
Doença da Artéria Coronariana , Transplante de Coração , Placa Aterosclerótica , Aloenxertos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/imunologia , Citocinas/imunologia , Transplante de Coração/efeitos adversos , Humanos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/etiologia , Placa Aterosclerótica/imunologia , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Ultrassonografia de Intervenção/métodos
12.
Circ J ; 75(11): 2573-80, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21821962

RESUMO

BACKGROUND: The TAXUS Japan Postmarket Surveillance Study (TAXUS-PMS) enrolled patients receiving percutaneous coronary intervention in real-world clinical practice. This analysis focuses on outcomes in the overall patient population and in a subgroup of diabetic patients. METHODS AND RESULTS: Between July 2007 and December 2008, 2,132 patients (with 2,504 lesions) were consecutively enrolled at 56 sites in Japan. One-year outcomes were analyzed. The prevalence of patients with diabetes was 44% (21% of diabetics were insulin-treated) and 5.5% of patients were receiving ongoing hemodialysis. The majority of patients received paclitaxel-eluting stents (PES) for `off-label' indications (68.2%). The rate of major adverse cardiovascular events (cardiac death, myocardial infarction, and target vessel revascularization (TVR)) at 1 year was 8.2%, driven mainly by TVR (6.9%). No differences in TVR, late loss or restenosis rates were found between diabetic and non-diabetic patients; outcomes in insulin- compared with oral hypoglycemic-treated diabetic patients, were similar. Multiple stent implantation and ostial lesion location were independent predictors for both major adverse cardiac events (MACE) and target lesion revascularization (TLR). Hemodialysis was an independent predictor for MACE but not TLR whereas in-stent restenosis was an independent predictor for TLR. CONCLUSIONS: TAXUS-PMS demonstrated a consistent, positive effect of PES in complex clinical cases. PES diminished the increased risk of clinical restenosis in diabetic patients, leading to a similar low risk of cardiac events in diabetic and non-diabetic patients.


Assuntos
Antineoplásicos Fitogênicos/farmacologia , Paclitaxel/farmacologia , Vigilância de Produtos Comercializados , Idoso , Angioplastia/efeitos adversos , Angioplastia/métodos , Antineoplásicos Fitogênicos/efeitos adversos , Morte , Complicações do Diabetes/mortalidade , Stents Farmacológicos , Feminino , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/mortalidade , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Paclitaxel/efeitos adversos , Prevalência , Diálise Renal , Estudos Retrospectivos , Fatores de Risco
14.
Circulation ; 116(8): 910-6, 2007 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-17684153

RESUMO

BACKGROUND: The time course of neointimal formation after stent implantation has not been studied extensively by angioscopy in the drug-eluting stent era. METHODS AND RESULTS: Serial angioscopic findings at first follow-up (3.6+/-1.1 months), second follow-up (10.5+/-1.6 months), and third follow-up (21.2+/-2.2 months) after stent implantation were compared between sirolimus-eluting stents (SES, n=17) and bare-metal stents (BMS, n=11). Neointimal coverage, thrombus, and presence of yellow plaques underneath the stents were assessed. Neointimal coverage was graded as follows: grade 0, stent struts were fully visible; grade 1, struts bulged into the lumen, although they were covered; grade 2, struts were embedded by the neointima but were seen translucently; or grade 3, struts were fully embedded and invisible. Neointimal coverage was remarkably different between SES and BMS at each follow-up point. Neointimal coverage grade was 1.1+/-0.5 in SES versus 2.9+/-0.3 in BMS at the first follow-up (P<0.0001), 1.1+/-0.5 in SES versus 3.0+/-0.0 in BMS (P<0.0001) at the second follow-up, and 1.3+/-0.5 in SES versus 3.0+/-0.0 in BMS at the third follow-up (P=0.0009). No significant serial changes in coverage grade were noted in the BMS group, whereas coverage grade slightly but significantly increased at the third follow-up in the SES group (P<0.05). Thrombi were detected in 4 SES: a red thrombus was seen from the first to the third follow-up in 2; another was detected only at the third follow-up; and the fourth was seen at the first follow-up but disappeared at the second follow-up, associated with a new white thrombus despite dual antiplatelet therapy. Yellow plaques had disappeared by the time of the second follow-up in BMS. In contrast, yellow plaques were exposed in 71% of SES at the first follow-up and remained exposed until the third follow-up. Neointimal coverage grades correlated with thrombi (P=0.002) and with yellow plaques (P<0.0001). CONCLUSIONS: Serial angioscopic findings up to 2 years after SES implantation were markedly different from those after BMS. Neointimal coverage was completed by 3 to 6 months in BMS. In contrast, SES demonstrated the presence of thrombi and yellow plaques even as much as 2 years after implantation.


Assuntos
Doença da Artéria Coronariana/terapia , Vasos Coronários/patologia , Imunossupressores/administração & dosagem , Sirolimo/administração & dosagem , Stents , Adulto , Idoso , Angioplastia Coronária com Balão , Estudos de Coortes , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/patologia , Reestenose Coronária/prevenção & controle , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/patologia , Trombose Coronária/prevenção & controle , Vasos Coronários/efeitos dos fármacos , Feminino , Seguimentos , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/administração & dosagem , Túnica Íntima/efeitos dos fármacos , Túnica Íntima/patologia
15.
Circulation ; 111(9): 1148-52, 2005 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-15723972

RESUMO

BACKGROUND: The pattern of saphenous vein graft (SVG) calcification before percutaneous intervention has not been studied. METHODS AND RESULTS: We used diagnostic and preintervention intravascular ultrasound (IVUS) to determine the incidence and magnitude of SVG calcification in 334 SVG lesions in 274 consecutive patients. Calcium was found in 133 SVGs (40%). Calcium was uniformly distributed among 48 lesion sites (14%), 43 proximal references (13%), and 42 distal references (13%). Calcium was superficial in 20 (40%) and deep in 28 (60%). Over the entire length of the SVGs, the maximum arc and length of calcium (in calcium-containing SVGs) averaged 174+/-107 degrees and 6.8+/-4.8 mm, respectively. In calcium-containing SVGs, lesion site arc and length of calcium measured 151+/-107 degrees and 4.1+/-3.7 mm, similar to the proximal and distal references (175+/-121 degrees and 4.0+/-2.3 mm and 177+/-121 degrees and 4.1+/-2.5 mm, respectively). Graft age (7.5+/-4.7 versus 10.5+/-4.7 years, P<0.0001), insulin-treated diabetes mellitus (40% versus 60%, P=0.02), and tobacco use (44% versus 55%, P=0.06) were clinical independent predictors of SVG calcification. CONCLUSIONS: Sixty-five percent of calcium-containing SVGs had reference calcium in the absence of lesion calcium. Calcium was located primarily in SVG wall and not at the plaque. These data suggest that SVG calcium is not just part of lesion formation and maturation. SVG calcium occurred more commonly in older grafts, in insulin-treated diabetic patients, and in smokers.


Assuntos
Calcinose/patologia , Angiografia Coronária , Ponte de Artéria Coronária , Reestenose Coronária/patologia , Complicações Pós-Operatórias/patologia , Veia Safena/patologia , Ultrassonografia de Intervenção , Idoso , Calcinose/diagnóstico por imagem , Calcinose/epidemiologia , Cálcio/análise , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/epidemiologia , Estenose Coronária/cirurgia , Diabetes Mellitus Tipo 2/epidemiologia , Feminino , Hemodinâmica , Humanos , Hipercolesterolemia/epidemiologia , Hipertensão/epidemiologia , Incidência , Nefropatias/epidemiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/epidemiologia , Período Pós-Operatório , Fatores de Risco , Veia Safena/química , Veia Safena/diagnóstico por imagem , Veia Safena/transplante , Fumar/epidemiologia
16.
Am J Cardiol ; 98(2): 272-4, 2006 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-16828607

RESUMO

Stent fracture has emerged as a new problem in the percutaneous transluminal angioplasty of the superficial femoral artery (SFA). The aim of our study was to delineate the factors influencing nitinol stent fracture in the SFA. Forty consecutive patients with peripheral artery disease who underwent rescue stenting with a nitinol stent (Luminexx, Bard) in the SFA were enrolled between May 2004 and January 2005. Follow-up angiography was performed 13.6+/-1.0 months later to detect stent fracture. Stent fracture occurred in 11 patients (28%). Lesion length>100 mm, the number of stents used, the lesion involving the distal SFA, chronic total occlusion, and walking>5,000 steps per day were more frequently observed in those with stent fracture than in those without fracture. Of these variables, walking>5,000 steps per day was the strongest independent determinant associated with stent fracture by discriminant analysis (p=0.0027). Vigorous exercise adversely affects stent fracture in patients implanted with a nitinol stent in the SFA.


Assuntos
Ligas , Arteriopatias Oclusivas/cirurgia , Implante de Prótese Vascular/instrumentação , Exercício Físico , Artéria Femoral , Oclusão de Enxerto Vascular/etiologia , Stents , Idoso , Angiografia , Arteriopatias Oclusivas/diagnóstico por imagem , Feminino , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Humanos , Masculino , Falha de Prótese , Estudos Retrospectivos , Fatores de Risco , Caminhada
18.
Eur Heart J Cardiovasc Imaging ; 17(1): 51-8, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25976347

RESUMO

AIMS: Neovascularization is closely associated with plaque progression in non-heart transplantation subjects; on the other hand, cardiac allograft vasculopathy causes unfavourable outcomes. Intravascular ultrasound (IVUS) and optical coherence tomography (OCT) can provide microscopic assessment in vivo. The aim of this study was to investigate the impact of neovascularization on intimal proliferation. METHODS AND RESULTS: Both IVUS and OCT were attempted in 45 consecutive patients during annual catheterization after heart transplantation. There were 115 vessels [28 vessels were catheterized within 8 weeks of heart transplantation (baseline)]. IVUS analysis assessed vessel, luminal, and intimal (vessel-lumen) volume using Simpson's method. Qualitative parameters including microchannel were assessed by OCT. A microchannel was defined as a no-signal tubuloluminal structure with a sharply delineated border considered to represent neovascularization. Microchannel was observed more often in patient who had their heart transplant more than a year prior to the imaging, compared with shorter periods (39.1 vs. 10.7%, P = 0.023). All microchannels were seen in thickness >0.5 mm, and intimal volume index (mm(3)/mm) correlated with frequency of microchannel (r = 0.54, P = 0.04). The risks for microchannels were donor age [odds ratio (OR) 1.11; 95% confidence interval (CI) 1.03-1.22; P = 0.007], cytomegalovirus infection (OR 16.21; 95% CI 1.79-220.09; P = 0.012), diabetes (OR 9.5; 95% CI 1.21-116.10; P = 0.032), LDL-cholesterol (OR 1.07; 95% CI 1.01-1.13; P = 0.010), and intimal volume (OR 2.47; 95% CI 1.13-6.36; P = 0.023). CONCLUSION: OCT-identified microchannels increased sharply within the first year and were correlated with intimal volume and coronary risks. This suggests that neovascularization may play an important role in the progression of cardiac allograft vasculopathy.


Assuntos
Rejeição de Enxerto/prevenção & controle , Cardiopatias/diagnóstico , Transplante de Coração , Imunossupressores/uso terapêutico , Neovascularização Patológica/diagnóstico , Tomografia de Coerência Óptica , Túnica Íntima/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Adulto , Aloenxertos , Doença das Coronárias/diagnóstico , Feminino , Seguimentos , Cardiopatias/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade , Resultado do Tratamento
19.
Circulation ; 108(1): 43-7, 2003 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-12821553

RESUMO

BACKGROUND: Factors leading to subacute stent thrombosis after percutaneous coronary intervention (PCI) have not been well established. We assessed the pre- and post-PCI intravascular ultrasound (IVUS) characteristics of subacute stent thrombosis. METHODS AND RESULTS: We analyzed 7484 consecutive patients without acute myocardial infarction who were treated with PCI and stenting and underwent IVUS imaging during the intervention. Twenty-seven (0.4%) had angiographically documented subacute closure <1 week after PCI (median time to subacute closure, 24 hours). Subacute closure lesions were compared with a control group (selected to be 3 times the abrupt closer group) matched by procedure date (within 6 months), age, gender, stable or unstable angina, lesion location, and additional treatment (balloon angioplasty or atherectomy). Postintervention IVUS did not identify a cause in 22% and did identify at least 1 cause for abrupt closure in 78% of patients (versus 33% in matched lesions, P=0.0002). In 48% of the patients, there were multiple causes in 48% (versus 3% in matched lesions, P<0.0001). Causes included dissection (17%), thrombus (4%), and tissue protrusion within the stent struts leading to lumen compromise lumen (4%). A total of 83% of patients with >1 of these abnormal morphologies also had reduced lumen dimensions post-PCI (final lumen <80% reference lumen). Preprocedural lesion characteristics were not different from matched lesions. CONCLUSIONS: Subacute stent thrombosis is infrequently related to the preintervention lesion characteristics. Inadequate postprocedure lumen dimensions, alone or in combination with other procedurally related abnormal lesion morphologies (dissection, thrombus, or tissue prolapse), contribute to this phenomenon.


Assuntos
Reestenose Coronária/diagnóstico por imagem , Trombose Coronária/diagnóstico por imagem , Stents/efeitos adversos , Ultrassonografia de Intervenção , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Doença das Coronárias/cirurgia , Reestenose Coronária/etiologia , Trombose Coronária/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Valor Preditivo dos Testes , Estudos Prospectivos , Taxa de Sobrevida , Grau de Desobstrução Vascular
20.
Circulation ; 106(13): 1672-7, 2002 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-12270861

RESUMO

BACKGROUND: No-reflow associated with direct angioplasty (PCI) of patients with acute coronary syndromes (ACS) is associated with unfavorable results. METHODS AND RESULTS: We used a new thrombectomy device to treat 51 lesions in 48 consecutive ACS patients (40 male and 8 female; mean age 63 years) and conducted a microscopic analysis of aspirates and blood samples retrieved from the culprit coronary artery. The first aspirate was collected before PCI and the second was collected separately after percutaneous transluminal coronary angioplasty or stenting, including samples from the no-reflow lumen. Light microscopy showed that the materials obtained from the pre-PCI aspiration consisted of thrombus in 37.5%, thrombus and atheroma in 35.0%, and atheromatous plaque in 27.5%. The materials collected from the post-PCI aspiration were thrombus in 8.3%, thrombus and atheroma in 41.7%, and atheromatous plaque in 50.0%. We then compared the 9 lesions (19.1%) with no-reflow to those without no-reflow. There was no difference in the pre-PCI aspirates. However, after PCI, there was more atheromatous plaque retrieved from patients with no-reflow (P<0.001) as well as significantly more platelet and fibrin complex, macrophages, and cholesterol crystals in the blood aspirated from no-reflow cases. Aspiration of these elements improved the no-reflow in 7 of 9 lesions to TIMI-3 flow. CONCLUSIONS: No-reflow after angioplasty may be caused by gruel that formed from an atheroma attributable to mechanical plaque disruption during intervention.


Assuntos
Arteriosclerose/fisiopatologia , Circulação Coronária , Doença das Coronárias/fisiopatologia , Vasos Coronários/fisiopatologia , Trombose/fisiopatologia , Doença Aguda , Angioplastia Coronária com Balão/efeitos adversos , Arteriosclerose/complicações , Arteriosclerose/patologia , Velocidade do Fluxo Sanguíneo , Implante de Prótese Vascular/efeitos adversos , Cateterismo/instrumentação , Angiografia Coronária , Doença das Coronárias/complicações , Doença das Coronárias/diagnóstico , Doença das Coronárias/cirurgia , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Stents , Trombectomia/instrumentação , Trombose/patologia , Trombose/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA