Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Anal Bioanal Chem ; 409(28): 6625-6634, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28932887

RESUMO

Due to the constant search for reliable methods to investigate glycoproteins in complex biological samples, an alternative approach combining affinity enrichment with rapid and sensitive analysis on-a-chip is presented. Glycoproteins were specifically captured by lectin-coated magnetic beads, eluted by competitive sugars, and investigated with microchip capillary gel electrophoresis (MCGE), i.e., CGE-on-a-chip. We compared our results to sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) data, which turned out to be in very good agreement. While SDS-PAGE offers the possibility of subsequent mass spectrometric analysis of captured and separated analytes, MCGE scores with time savings, higher throughput, and lower sample consumption as well as quality control (QC) and process analytical technology (PAT) applicability. Due to these advantages, a lectin-based glycoprotein capture protocol can easily be optimized. In our case, two different types of magnetic beads were tested and compared regarding lectin binding. The selectivity of our strategy was demonstrated with a set of model glycoproteins, as well as with human serum and serum depleted from high-abundance proteins. The specificity of the capturing method was investigated revealing to a certain degree an unspecific binding between each sample and the beads themselves, which has to be considered for any specific enrichment and data interpretation. In addition, two glycoproteins from Trichoderma atroviride, a fungus with mycoparasitic activity and only barely studied glycoproteome, were enriched by means of a lectin and so identified for the first time. Graphical abstract Glycoproteins from biological samples were detected by microchip capillary gel electrophoresis after lectin affinity enrichment using magnetic beads and elution with respective competitive monosaccharides.


Assuntos
Eletroforese em Microchip/métodos , Glicoproteínas/análise , Lectinas/química , Imãs/química , Proteínas Sanguíneas/análise , Proteínas Sanguíneas/isolamento & purificação , Glicoproteínas/isolamento & purificação , Humanos , Proteínas Imobilizadas/química , Modelos Moleculares , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
2.
Anal Bioanal Chem ; 408(16): 4209-17, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27020928

RESUMO

Liquid-phase electrophoresis either in the classical capillary format or miniaturized (chip CE) is a valuable tool for quality control of virus preparations and for targeting questions related to conformational changes of viruses during infection. We present an in vitro assay to follow the release of the RNA genome from a human rhinovirus (common cold virus) by using a molecular beacon (MB) and chip CE. The MB, a probe that becomes fluorescent upon hybridization to a complementary sequence, was designed to bind close to the 3' end of the viral genome. Addition of Trolox (6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid), a well-known additive for reduction of bleaching and blinking of fluorophores in fluorescence microscopy, to the background electrolyte increased the sensitivity of our chip CE set-up. Hence, a fast, sensitive and straightforward method for the detection of viral RNA is introduced. Additionally, challenges of our assay will be discussed. In particular, we found that (i) desalting of virus preparations prior to analysis increased the recorded signal and (ii) the MB-RNA complex signal decreased with the time of virus storage at -70 °C. This suggests that 3'-proximal sequences of the viral RNA, if not the whole genome, underwent degradation during storage and/or freezing and thawing. In summary, we demonstrate, for two independent virus batches, that chip electrophoresis can be used to monitor MB hybridization to RNA released upon incubation of the native virus at 56 °C. Graphical Abstract Schematic of the study strategy: RNA released from HRV-A2 is detected by chip electrophoresis through the increase in fluorescence after genom complexation to a cognate molecular beacon.


Assuntos
Eletroforese Capilar/métodos , Infecções por Picornaviridae/virologia , RNA Viral/química , Rhinovirus/isolamento & purificação , Cromanos/química , Eletroforese Capilar/instrumentação , Fluorescência , Corantes Fluorescentes/química , Humanos , RNA Viral/genética , Rhinovirus/genética
3.
Electrophoresis ; 36(15): 1754-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25931050

RESUMO

Glycosylations severely influence a protein's biological and physicochemical properties. Five exemplary proteins with varying glycan moieties were chosen to establish molecular weight (MW) determination (sizing), quantitation, and sensitivity of detection for microchip capillary gel electrophoresis (MCGE). Although sizing showed increasing deviations from literature values (SDS-PAGE or MALDI-MS) with a concomitant higher degree of analyte glycosylation, the reproducibility of MW determination and accuracy of quantitation with high sensitivity and reliability were demonstrated. Additionally, speed of analysis together with the low level of analyte consumption render MCGE attractive as an alternative to conventional SDS-PAGE.


Assuntos
Eletroforese em Microchip/métodos , Glicoproteínas/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Electrophoresis ; 34(24): 3267-76, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24114950

RESUMO

Biodegradable nanoparticles (NPs) and hence e.g. NPs prepared from glutaraldehyde crosslinked gelatin (gelatin NPs) are lately receiving increased attention in various fields like pharmaceutical technology and nutraceutics as biocompatible carriers for hardly water soluble drugs, molecules intended for sustained release or targeted transport. However, in vivo application of such materials requires a thoroughly characterization of corresponding particles. In a previous manuscript we demonstrated the applicability of chip electrophoresis for the separation of gelatin NPs from NP building blocks. Following our previous results we intensified our efforts in the characterization of gelatin NPs by electrophoresis in the liquid (capillary and chip format) and the gas phase (gas phase electrophoretic mobility molecular analysis, GEMMA). In doing so, we demonstrated differences between nominally comparable (from the concentration of initially employed material for crosslinking) gelatin NP preparation batches concerning (i) the amount of obtained NPs, (ii) the degree of NP crosslinking, (iii) the amount of NP building blocks present within samples and (iv) the electrophoretic mobility diameter of NPs. Differences were even more pronounced when NP preparations from batches with different content of initially employed gelatin were compared. Additionally, we compared three setups for the removal of low molecular weight components from samples after fluorescence labeling of NPs. In overall, the combination of the three employed analytical methods for gelatin NP characterization - CE in the capillary and the chip format as well as GEMMA - allows a more thoroughly characterization of NP containing samples.


Assuntos
Eletroforese em Microchip , Gelatina/química , Nanopartículas/química , Reagentes de Ligações Cruzadas/química , Gases/química , Tamanho da Partícula
5.
Anal Chem ; 83(4): 1443-7, 2011 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-21265515

RESUMO

Bead assays are an important rapid microbial detection technology suitable for extremely low pathogen levels. We report a bead assay for rRNA extracted from Escherichia coli K12 that does not require amplification steps and has readout on an Agilent 2100 Bioanalyzer flow cytometry system. Our assay was able to detect 125 ng of RNA, which is 16 times less than reported earlier. The specificity was extremely high, with no binding to a negative control organism (Bacillus subtilis). We discuss challenges faced during optimization of the key assay components, such as varying amounts of RNA in the samples, number of beads, aggregation, and reproducibility.


Assuntos
Escherichia coli K12/isolamento & purificação , Citometria de Fluxo/métodos , Viabilidade Microbiana , Microesferas , Sequência de Bases , Escherichia coli K12/genética , Modelos Moleculares , Conformação de Ácido Nucleico , Sondas de Oligonucleotídeos/química , Sondas de Oligonucleotídeos/genética , Poliestirenos/química , RNA Ribossômico/análise , RNA Ribossômico/química , RNA Ribossômico/genética , Espectrometria de Fluorescência
7.
Electrophoresis ; 31(23-24): 3850-62, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21086437

RESUMO

The molecular weights (MW) of seven (glyco)proteins, of which five were plasma-derived, with MWs higher than 200 kDa were determined with three techniques: CGE-on-a-chip, SDS-PAGE and MALDI-TOF-MS. While the analysis of medium to high MW proteins with SDS-PAGE was an already well-established technique, the usefulness of MALDI-TOF-MS for the exact MW determination of high mass proteins was only partly described in literature so far. CGE-on-a-chip is the newest of all three applied techniques and was so far not applicable. Therefore, it was not evaluated for high MW (glyco)proteins. All proteins were analyzed under nonreducing as well as reducing conditions. In this work, it was demonstrated that all three described techniques were capable of determining the MW of all high molecular weight (glyco)proteins. The noncommercial CGE-on-a-chip assay allowed for the first time the electrophoretic separation of proteins in the MW range from 14 to 1000 kDa. MW assignment was limited to 500 kDa in the case of SDS-PAGE and 660 kDa in the case of the high MW CGE-on-a-chip assay. With the proper matrix and sample preparation, analysis with a standard MALDI-TOF-MS provided accurate MWs for all high MW proteins up to 1 MDa.


Assuntos
Proteínas Sanguíneas/química , Eletroforese Capilar/métodos , Eletroforese em Gel de Poliacrilamida/métodos , Glicoproteínas/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Animais , Bovinos , Gastrópodes , Glicoproteínas/sangue , Humanos , Peso Molecular
8.
Methods Mol Biol ; 875: 253-62, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22573445

RESUMO

Bead assays are an emerging microbial detection technology with the capability for rapid detection of extremely low levels of viable pathogens. Such technologies are of high value in clinical settings and in the food industry. Here, we perform a bead assay for extracted 16S rRNA from Escherichia coli (strain K12) with the flow cytometry readout on a 2100 Bioanalyzer, a highly accurate, small-scale flow cytometer system.


Assuntos
Bactérias/isolamento & purificação , Citometria de Fluxo , RNA Bacteriano/análise , Bactérias/classificação , Bactérias/genética , Escherichia coli/genética , Citometria de Fluxo/instrumentação , Corantes Fluorescentes/química , Microesferas , Hibridização de Ácido Nucleico , Oligonucleotídeos/química , RNA Bacteriano/isolamento & purificação , RNA Ribossômico 16S , Coloração e Rotulagem
9.
Clin Chem Lab Med ; 46(4): 490-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18605933

RESUMO

BACKGROUND: High-density lipoprotein (HDL) subfractions are among the new emerging risk factors for atherosclerosis. In particular, HDL 2b has been shown to be linked to cardiovascular risk. This study uses a novel microfluidics-based method to establish HDL 2b clinical utility using samples from the Prospective Cardiovascular Muenster (PROCAM) Study. METHODS: Method performance was established by measuring accuracy, precision, linearity and inter-site precision. Serum samples from 503 individuals collected in the context of the PROCAM study were analyzed by electrophoresis on a microfluidics system. Of these, 251 were male survivors of myocardial infarction (cases), while 252 individuals were matched healthy controls. HDL cholesterol, HDL 2b concentration and HDL 2b percentage were analyzed. RESULTS: This novel method showed satisfactory assay performance with an inter-site coefficient of variance of <10% for HDL 2b percentage. Parallel patient testing on 52 samples between two sites resulted in a correlation coefficient of r=0.95. Significant differences were observed in the HDL 2b subfraction between cases and controls independent of other risk factors. Including HDL 2b percentage in logistic regression reduced the number of false positives from 64 to 39 and the number of false negative cases from 48 to 45, in the context of this study. CONCLUSIONS: The novel method showed satisfactory assay performance in addition to drastically reduced analysis times and improved ease of use as compared to other methods. Clinical utility of HDL 2b was demonstrated supporting the findings of previous studies.


Assuntos
Análise Química do Sangue/métodos , HDL-Colesterol/sangue , Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Adolescente , Adulto , Idoso , Algoritmos , Estudos de Coortes , Humanos , Masculino , Técnicas Analíticas Microfluídicas , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Risco , Frações Subcelulares
10.
Biol Chem ; 388(2): 197-206, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17261083

RESUMO

Changes in chromatin structure, histone phosphorylation and cleavage of DNA into nucleosome-size fragments are characteristic features of apoptosis. Since H1 histones bind to the site of DNA cleavage between nucleosomal cores, the question arises as to whether the state of H1 phosphorylation influences the rate of internucleosomal cleavage. Here, we tested the relation between DNA fragmentation and H1 phosphorylation both in cultured cells and in vitro. In Jurkat cells, hyperosmotic mannitol concentration resulted in apoptosis, including nucleosomal fragmentation, whereas apoptosis induction by increased NaCl concentration was not accompanied by DNA fragmentation. However, both treatments induced dephosphorylation of H1 histones. In contrast, treatment of Raji cells with alkylphosphocholine led to induction of apoptosis with internucleosomal fragmentation, albeit without notable histone H1 dephosphorylation. These results demonstrate that dephosphorylation of H1 histones is neither a prerequisite for nor a consequence of internucleosomal cleavage. Moreover, we observed with an in vitro assay that the known enhancing effect of H1 histones on the activity of the apoptosis-induced endonuclease DFF40 is independent of the subtype or the phosphorylation state of the linker histone.


Assuntos
Apoptose/efeitos dos fármacos , Fragmentação do DNA/efeitos dos fármacos , Histonas/metabolismo , Linhagem Celular Tumoral , Desoxirribonucleases/efeitos dos fármacos , Desoxirribonucleases/metabolismo , Histonas/química , Histonas/isolamento & purificação , Humanos , Células Jurkat/efeitos dos fármacos , Pressão Osmótica , Fosforilação , Proteínas de Ligação a Poli-ADP-Ribose , Estaurosporina/farmacologia
11.
J Biomol Tech ; 13(3): 172-8, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19498980

RESUMO

The performance of the Agilent 2100 bioanalyzer, the first commercial lab-on-a-chip system, and the Protein 200 Plus LabChip kit is compared with conventional protein analysis techniques such as SDS-PAGE, Lowry, or Bradford. Lab-on-a-chip technology for protein analysis allows for the integration of electrophoretic separation, staining, destaining, and fluorescence detection into a single process, and for it to be combined with data analysis. The chip-based protein assay allows purity analysis, sizing, and relative quantitation based on internal standards or absolute quantitation based on user-defined standards. The chip-based protein analysis is comparable in sensitivity, sizing accuracy, and reproducibility to SDS-PAGE stained with standard Coomassie. Resolution and linear dynamic range are improved. Absolute quantitation accuracy and reproducibility is improved in comparison to SDS-PAGE and is comparable to batch-based quantitation methods such as Lowry and Bradford. The lab-on-a-chip system has several additional advantages over conventional SDS-PAGE including fast analysis times, reduced manual labor, automated data analysis, and good reproducibility. With such a system, the protein of interest can be tracked during the whole purification procedure, for example, from cell lysates through column fractions to purified proteins.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA