BACKGROUND: To assess the risk of aspiration, nutrient tolerance, and gastric emptying of patients in ICUs, gastric ultrasound can provide information about the gastric contents. Using established formulas, the gastric residual volume (GRV) can be calculated in a standardized way by measuring the gastric antrum. The purpose of this study was to determine the GRV in a cohort of enterally fed patients using a miniaturized ultrasound device to achieve knowledge about feasibility and the GRV over time during the ICU stay. The findings could contribute to the optimization of enteral nutrition (EN) therapy. METHODS: A total of 217 ultrasound examinations with 3 measurements each (651 measurements in total) were performed twice daily (morning and evening) in a longitudinal observational study on 18 patients with EN in the interdisciplinary surgical ICU of Saarland University Medical Center. The measured values of the GRV were analyzed in relation to the clinical course, the nutrition, and other parameters. RESULTS: Measurements could be performed without interrupting the flow of clinical care and without pausing EN. The GRV was significantly larger with sparsely auscultated bowel sounds than with normal and excited bowel sounds (p < 0.01). Furthermore, a significantly larger GRV was present when using a high-caloric/low-protein nutritional product compared to an isocaloric product (p = 0.02). The GRV at the morning and evening measurements showed no circadian rhythm. When comparing the first and last ultrasound examination of each patient, there was a tendency towards an increased GRV (p = 0.07). CONCLUSION: The GRV measured by miniaturized ultrasound devices can provide important information about ICU patients without restricting treatment procedures in the ICU. Measurements are possible while EN therapy is ongoing. Further studies are needed to establish gastric ultrasound as a management tool in nutrition therapy.

2.
J Clin Med ; 10(16)2021 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-34441846

RESUMO

(1) Background: Reliable ultrasonographic measurements of optic nerve sheath diameter (ONSD) to detect increased intracerebral pressure (ICP) has not been established in awake patients with continuous invasive ICP monitoring. Therefore, in this study, we included fully awake patients with and without raised ICP and correlated ONSD with continuously measured ICP values. (2) Methods: In a prospective study, intracranial pressure (ICP) was continuously measured in 25 patients with an intraparenchymatic P-tel probe. Ultrasonic measurements were carried out three times for each optic nerve in vertical and horizontal directions. ONSD measurements and ICP were correlated. Patients with ICP of 2.0-10.0 mmHg were compared with patients suffering from an ICP of 10.1-24.2 mmHg. (3) Results: In all patients, the ONSD vertical and horizontal measurement for both eyes correlated well with the ICP (Pearson R = 0.68-0.80). Both measurements yielded similar results (Bland-Altman: vertical bias: -0.09 mm, accuracy: ±0.66 mm; horizontal bias: -0.06 mm, accuracy: ±0.48 mm). For patients with an ICP of 2.0-10.0 mmHg compared to an ICP of 10.1-24.2, ROC (receiver operating characteristic) analyses showed that ONSD measurement accurately predicts elevated ICP (optimal cut-off value 5.05 mm, AUC of 0.91, sensitivity 92% and specificity 90%, p < 0.001). (4) Conclusions: Ultrasonographic measurement of ONSD in awake, spontaneously breathing patients provides a valuable method to evaluate patients with suspected increased ICP. Additionally, it provides a potential tool for rapid assessment of ICP at the bedside and to identify patients at risk for a poor neurological outcome.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA