Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
AJR Am J Roentgenol ; 221(6): 788-804, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37377363

RESUMO

The first commercially available 7-T MRI scanner (Magnetom Terra) was approved by the FDA in 2017 for clinical imaging of the brain and knee. After initial protocol development and sequence optimization efforts in volunteers, the 7-T system, in combination with an FDA-approved 1-channel transmit/32-channel receive array head coil, can now be routinely used for clinical brain MRI examinations. The ultrahigh field strength of 7-T MRI has the advantages of improved spatial resolution, increased SNR, and increased CNR but also introduces an array of new technical challenges. The purpose of this article is to describe an institutional experience with the use of the commercially available 7-T MRI scanner for routine clinical brain imaging. Specific clinical indications for which 7-T MRI may be useful for brain imaging include brain tumor evaluation with possible perfusion imaging and/or spectroscopy, radiotherapy planning; evaluation of multiple sclerosis and other demyelinating diseases, evaluation of Parkinson disease and guidance of deep brain stimulator placement, high-detail intracranial MRA and vessel wall imaging, evaluation of pituitary pathology, and evaluation of epilepsy. Detailed protocols, including sequence parameters, for these various indications are presented, and implementation challenges (including artifacts, safety, and side effects) and potential solutions are explored.


Assuntos
Neoplasias Encefálicas , Epilepsia , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Neuroimagem/métodos , Neoplasias Encefálicas/diagnóstico por imagem
2.
Magn Reson Med ; 79(1): 511-514, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28342176

RESUMO

PURPOSE: In this work, we investigated the relative effects of static magnetic field exposure (10.5 Tesla [T]) on two physiological parameters; blood pressure (BP) and heart rate (HR). METHODS: In vivo, we recorded both BP and HR in 4 swine (3 female, 1 male) while they were positioned within a 10.5T magnet. All measurements were performed invasively within these anesthetized animals by the placement of pressure catheters into their carotid arteries. RESULTS: We measured average increases of 2.0 mm Hg (standard deviation [SD], 6.9) in systolic BP and an increase of 4.5 mm Hg (SD, 13.7) in the diastolic BPs: We also noted an average increase of 1.2 beats per minute (SD, 2.5) in the HRs during such. CONCLUSION: Data regarding changes in BP and HR in anesthetized swine attributed to whole-body 10.5T exposure are reported. Magn Reson Med 79:511-514, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Anestesia , Pressão Sanguínea , Frequência Cardíaca , Campos Magnéticos , Animais , Determinação da Pressão Arterial , Artérias Carótidas/diagnóstico por imagem , Diástole , Feminino , Imageamento por Ressonância Magnética , Masculino , Suínos , Sístole
3.
Magn Reson Med ; 66(1): 255-63, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21337423

RESUMO

Temperatures were measured in vivo in four pigs (mean animal weight = 110.75 kg and standard deviation = 6.13 kg) due to a continuous wave radiofrequency (RF) power irradiation with a 31.75 cm internal diameter and a 15.24 cm long, 7 T (296 MHz), eight channel, transverse electromagnetic head coil. The temperatures were measured in the subcutaneous layer of the scalp, 5, 10, 15, and 20 mm deep in the brain, and rectum using fluoroptic temperature probes. The RF power was delivered to the pig's head for ∼3 h (mean deposition time = 3.14 h and standard deviation = 0.06 h) at the whole head average specific absorption rate of ∼3 W kg(-1) (mean average specific absorption rate = 3.08 W kg(-1) and standard deviation = 0.09 W kg(-1)). Next, simple bioheat transfer models were used to simulate the RF power induced temperature changes. Results show that the RF power produced uniform temperature changes in the pigs' heads (mean temperature change = 1.68°C and standard deviation = 0.13°C) with no plateau achieved during the heating. No thermoregulatory alterations were detected due to the heating because the temperature responses of the pre-RF and post-RF epochs were not statistically significantly different. Simple, validated bioheat models may provide accurate temperature changes.


Assuntos
Encéfalo/efeitos da radiação , Temperatura Alta , Imageamento por Ressonância Magnética/instrumentação , Ondas de Rádio , Animais , Humanos , Modelos Animais , Segurança , Suínos
4.
Magn Reson Med ; 62(4): 888-95, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19572392

RESUMO

In vivo thermoregulatory temperature response to radio frequency (RF) heating at 9.4T was studied by measuring temperatures in nine anesthetized swine. Temperatures were measured in the scalp, brain, and rectum. The RF energy was deposited using a four-loop head coil tuned to 400.2 MHz. Sham RF was delivered to three swine to understand the thermal effects of anesthesia (animal weight = 54.16 kg, SD = 3.08 kg). Continuous wave (CW) RF energy was delivered to the other six animals for 2.5-3.4 h (animal weight = 74.01 +/- 26.0 kg, heating duration = 3.05 +/- 0.29 h). The whole-head specific absorption rate (SAR) varied between 2.71 W/kg and 3.20 W/kg (SAR = 2.93 +/- 0.18 W/kg). Anesthesia caused the brain and rectal temperatures to drop linearly. Altered thermoregulatory response was detected by comparing the difference in the temperature slopes before and after the RF delivery from zero. RF heating statistically significantly altered the rate of cooling down of the animal. The temperature slope changes correlated well with the RF energy per unit head weight and heating duration, and the maximum rectal temperature change during heating in heated animals. The temperature slope changes did not correlate well to the whole-head average SARs.


Assuntos
Regulação da Temperatura Corporal/fisiologia , Regulação da Temperatura Corporal/efeitos da radiação , Imageamento por Ressonância Magnética , Animais , Relação Dose-Resposta à Radiação , Doses de Radiação , Ondas de Rádio , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA