1.
Chemistry ; 30(19): e202304169, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38270385

RESUMO

Helical nanographenes have garnered substantial attention owing to their finely adjustable optical and semiconducting properties. The strategic integration of both helicity and heteroatoms into the nanographene structure, facilitated by a boron-oxygen-based multiple resonance (MR) thermally activated delayed fluorescence (TADF), elevates its photophysical and chiroptical features. This signifies the introduction of an elegant category of helical nanographene that combines optical (TADF) and chiroptical (CPL) features. In this direction, we report the synthesis, optical, and chiroptical properties of boron, oxygen-doped Π-extended helical nanographene. The π-extension induces distortion in the DOBNA-incorporated nanographene, endowing a pair of helicenes, (P)-B2NG, and (M)-B2NG exhibiting circularly polarized luminescence with glum of -2.3×10-3 and +2.5×10-3, respectively. B2NG exhibited MR-TADF with a lifetime below 5 µs, and a reasonably high fluorescence quantum yield (50 %). Our molecular design enriches the optical and chiroptical properties of nanographenes and opens up new opportunities in multidisciplinary fields.

2.
Radiology ; 309(2): e223146, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37934095

RESUMO

Nonalcoholic fatty liver disease (NAFLD) is a common cause of morbidity and mortality. Nonfocal liver biopsy is the historical reference standard for evaluating NAFLD, but it is limited by invasiveness, high cost, and sampling error. Imaging methods are ideally situated to provide quantifiable results and rule out other anatomic diseases of the liver. MRI and US have shown great promise for the noninvasive evaluation of NAFLD. US is particularly well suited to address the population-level problem of NAFLD because it is lower-cost, more available, and more tolerable to a broader range of patients than MRI. Noninvasive US methods to evaluate liver fibrosis are widely available, and US-based tools to evaluate steatosis and inflammation are gaining traction. US techniques including shear-wave elastography, Doppler spectral imaging, attenuation coefficient, hepatorenal index, speed of sound, and backscatter-based estimation have regulatory clearance and are in clinical use. New methods based on channel and radiofrequency data analysis approaches have shown promise but are mostly experimental. This review discusses the advantages and limitations of clinically available and experimental approaches to sonographic liver tissue characterization for NAFLD diagnosis as well as future applications and strategies to overcome current limitations.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Humanos , Biópsia , Inflamação
3.
J Ultrasound Med ; 42(10): 2247-2255, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37159490

RESUMO

OBJECTIVES: The primary aim was to estimate the influence of various depths on ultrasound attenuation coefficient (AC) of multiple vendors in the liver. The secondary aim was to evaluate the impact of region of interest (ROI) size on AC measurements in a subset of participants. METHODS: This Institutional Review Board (IRB)-approved Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study was carried out in two centers using AC-Canon and AC-Philips algorithms and extracting AC-Siemens values from ultrasound-derived fat fraction algorithm. Measurements were performed positioning ROI upper edge (3 cm size) at 2, 3, 4, 5 cm from the liver capsule with AC-Canon and AC-Philips and at 1.5, 2, 3 cm with Siemens algorithm. In a subset of participants, measurements were obtained with 1 and 3 cm ROI size. Univariate and multivariate linear regression models and Lin's concordance correlation coefficient (CCC) were used for statistical analysis as appropriate. RESULTS: Three different cohorts were studied. Sixty-three participants (34 females; mean age: 51 ± 14 years) were studied with AC-Canon, 60 (46 females; mean age: 57 ± 11 years) with AC-Philips, and 50 (25 females; 61 ± 13 years) with AC-Siemens. There was a decrease in AC values per 1 cm increase in depth in all. In multivariable analysis, the coefficient was -0.049 (-0.060; -0.038 P < .001) with AC-Canon, -0.058 (-0.066; -0.049 P < .001) with AC-Philips and -0.081 (-0.112; -0.050 P < .001) with AC-Siemens. AC values with 1 cm ROI were significantly higher than those obtained with 3 cm ROI at all depths (P < .001) but the agreement between AC values obtained with different ROI size was excellent (CCC 0.82 [0.77-0.88]). CONCLUSIONS: There is depth dependence in AC measurement that affects results. A standardized protocol with fixed ROI's depth and size is needed.


Assuntos
Algoritmos , Fígado , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Reprodutibilidade dos Testes , Fígado/diagnóstico por imagem , Ultrassonografia/métodos
4.
Angew Chem Int Ed Engl ; 62(34): e202307381, 2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37384373

RESUMO

The high demand for light-emitting and display devices made luminescent organic materials as attractive candidates. Solvent-free organic liquids are one of the promising emitters among them due to the salient features. However, the inherent limitations of forming sticky and noncurable surfaces must be addressed to become an alternate emitter for large-area device applications. Herein, we functionalized solvent-free organic liquids having monomeric emission in bulk with polymerizable groups to improve the processability. The polymerizable group on carbazole, naphthalene monoimide, and diketopyrrolopyrrole-based solvent-free liquid emitters enabled on-surface polymerization. These emitters alone and in combinations can be directly coated on a glass substrate without the help of solvents. Subsequent photo or thermal polymerization leads to stable, non-sticky, flexible, foldable, and free-standing large-area films with reasonably high quantum yield. Our demonstration of the tunable and white light-emitting films using polymerizable solvent-free liquids might be a potential candidate in flexible/foldable/stretchable electronics. The new concept of polymerizable liquid can be extended to other functional features suitable for futuristic applications.

5.
Angew Chem Int Ed Engl ; 62(47): e202311657, 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37782466

RESUMO

Recently, chiral and nonplanar cutouts of graphene have been the favorites due to their unique optical, electronic, and redox properties and high solubility compared with their planar counterparts. Despite the remarkable progress in helicenes, π-extended heterohelicenes have not been widely explored. As an anode in a lithium-ion battery, the racemic mixture of π-extended double heterohelical nanographene containing thienothiophene core exhibited a high lithium storage capability, attaining a specific capacity of 424 mAh g-1 at 0.1 A g-1 with excellent rate capability and superior long-term cycling performance over 6000 cycles with negligible fade. As a first report, the π-extended helicene isomer (PP and MM), with the more interlayer distance that helps faster diffusion of ions, has exhibited a high capacity of 300 mAh g-1 at 2 A g-1 with long-term cycling performance over 1500 cycles compared to the less performing MP and PM isomer and racemic mixture (150 mAh g-1 at 2 A g-1 ). As supported by single-crystal X-ray analysis, a unique molecular design of nanographenes with a fixed (helical) molecular geometry, avoiding restacking of the layers, renders better performance as an anode in lithium-ion batteries. Interestingly, the recycled nanographene anode material displayed comparable performance.

6.
Radiology ; 302(3): 495-506, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35076304

RESUMO

Nonalcoholic fatty liver disease (NAFLD) is the most common chronic liver disease worldwide, with an estimated prevalence of up to 30% in the general population and higher in people with type 2 diabetes. The assessment of liver fat content is essential to help identify patients with or who are at risk for NAFLD and to follow their disease over time. The American Institute of Ultrasound in Medicine-RSNA Quantitative Imaging Biomarkers Alliance Pulse-Echo Quantitative Ultrasound Initiative was formed to help develop and standardize acquisition protocols and to better understand confounding factors of US-based fat quantification. The three quantitative US parameters explored by the initiative are attenuation, backscatter coefficient, and speed of sound. The purpose of this review is to present the current state of attenuation imaging for fat quantification and to provide expert opinion on examination performance and interpretation. US attenuation methods that need further study are outlined.


Assuntos
Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Ultrassonografia/métodos , Humanos , Padrões de Referência
7.
J Hepatol ; 73(1): 161-169, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32145257

RESUMO

BACKGROUND & AIMS: The vitronectin receptor integrin αvß3 drives fibrogenic activation of hepatic stellate cells (HSCs). Molecular imaging targeting the integrin αvß3 could provide a non-invasive method for evaluating the expression and the function of the integrin αvß3 on activated HSCs (aHSCs) in the injured liver. In this study, we sought to compare differences in the uptake of [18F]-Alfatide between normal and injured liver to evaluate its utility for assessment of hepatic fibrogenesis. METHODS: PET with [18F]-Alfatide, non-enhanced CT, histopathology, immunofluorescence staining, immunoblotting and gene analysis were performed to evaluate and quantify hepatic integrin αvß3 levels and liver fibrosis progression in mouse models of fibrosis (carbon tetrachloride [CCl4] and bile duct ligation [BDL]). The liver AUC divided by the blood AUC over 30 min was used as an integrin αvß3-PET index to quantify fibrosis progression. Ex vivo analysis of frozen liver tissue from patients with fibrosis and cirrhosis verified the animal findings. RESULTS: Fibrotic mouse livers showed enhanced [18F]-Alfatide uptake and retention compared to control livers. The radiotracer was demonstrated to bind specifically with integrin αvß3, which is mainly expressed on aHSCs. Autoradiography and histopathology confirmed the PET imaging results. Further, the mRNA and protein level of integrin αvß3 and its signaling complex were higher in CCl4 and BDL models than controls. The results obtained from analyses on human fibrotic liver sections supported the animal findings. CONCLUSIONS: Imaging hepatic integrin αvß3 with PET and [18F]-Alfatide offers a potential non-invasive method for monitoring the progression of liver fibrosis. LAY SUMMARY: Integrin αvß3 expression on activated hepatic stellate cells (aHSCs) is associated with HSC proliferation during hepatic fibrogenesis. Herein, we show that a radioactive tracer, [18F]-Alfatide, binds to integrin αvß3 with high affinity and specificity. [18F]-Alfatide could thus be used as a non-invasive imaging biomarker to track hepatic fibrosis progression.


Assuntos
Células Estreladas do Fígado/metabolismo , Integrina alfaVbeta3/metabolismo , Cirrose Hepática , Peptídeos Cíclicos/farmacologia , Tomografia por Emissão de Pósitrons/métodos , Animais , Progressão da Doença , Imunofluorescência/métodos , Radioisótopos de Flúor/farmacologia , Perfilação da Expressão Gênica/métodos , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/metabolismo , Cirrose Hepática/patologia , Camundongos , Imagem Molecular/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
J Ultrasound Med ; 38(7): 1875-1885, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30419612

RESUMO

B-mode ultrasound imaging guidance of cannulas can be compromised by noise, artifacts, and echogenicity that is not distinctive from that of surrounding anatomy. We have modified a venovenous extracorporeal membrane oxygenation cannula by embedding piezoelectric crystals into each of its 3 blood flow ports. Each vibrating crystal acoustically interacts with a Doppler imaging signal and produces an instantaneous color marker. The aim of this study was to compare identification of the extracorporeal membrane oxygenation cannula ports by B-mode imaging versus the color Doppler marker. Unlike B-mode imaging, the color Doppler marker identified the corresponding port even in highly challenging closed-chest scans in anesthetized pigs. The method could improve guidance accuracy of cannulas by ultrasound scans.


Assuntos
Oxigenação por Membrana Extracorpórea/instrumentação , Ultrassonografia Doppler em Cores , Ultrassonografia de Intervenção/métodos , Animais , Desenho de Equipamento , Suínos
9.
J Acoust Soc Am ; 145(3): EL236, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-31067972

RESUMO

Sparse array (SA) is an approach to reduce the number of system channels. However, SA suffers from grating lobe (GL) artefacts due to the sparsity of array aperture resulting in degradation of the ultrasound image quality. Based on a given or known data sets of radio frequency (RF) echo acquired from active elements of an array, RF echo data in unknown and/or inactive elements of array can be created virtually and used to suppress the GL artefact in SA. This letter presents gap-filling (GF) approaches to generate channel data, which are not physically acquired. It is demonstrated that the proposed GF technique can reduce the artefacts of SA by filling the gaps in the array aperture. Simulation results show that the GF technique can suppress the GL level of SA by up to 16 dB. Also, the GF technique can improve the image quality of fully sampled arrays with small number of active elements.


Assuntos
Ondas Ultrassônicas , Ultrassonografia/métodos , Acústica , Algoritmos , Modelos Teóricos , Ultrassonografia/normas
10.
Sensors (Basel) ; 19(4)2019 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-30813465

RESUMO

Vibrational characteristics of bone are directly dependent on its physical properties. In this study, a vibrational method for bone evaluation is introduced. We propose a new type of quantitative vibro-acoustic method based on the acoustic radiation force of ultrasound for bone characterization in persons with fracture. Using this method, we excited the clavicle or ulna by an ultrasound radiation force pulse which induces vibrations in the bone, resulting in an acoustic wave that is measured by a hydrophone placed on the skin. The acoustic signals were used for wave velocity estimation based on a cross-correlation technique. To further separate different vibration characteristics, we adopted a variational mode decomposition technique to decompose the received signal into an ensemble of band-limited intrinsic mode functions, allowing analysis of the acoustic signals by their constitutive components. This prospective study included 15 patients: 12 with clavicle fractures and three with ulna fractures. Contralateral intact bones were used as controls. Statistical analysis demonstrated that fractured bones can be differentiated from intact ones with a detection probability of 80%. Additionally, we introduce a "healing factor" to quantify the bone healing progress which successfully tracked the progress of healing in 80% of the clavicle fractures in the study.


Assuntos
Consolidação da Fratura/fisiologia , Ultrassonografia/métodos , Adolescente , Criança , Feminino , Fraturas Ósseas/diagnóstico por imagem , Humanos , Masculino , Projetos Piloto
11.
J Ultrasound Med ; 34(8): 1351-61, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26206821

RESUMO

OBJECTIVES: High-intensity focused ultrasound (HIFU) has been used noninvasively for therapeutic applications. Before HIFU can be used therapeutically on a human fetus, the bioeffects related to HIFU must be studied, and the mechanism causing the bioeffects should be understood. Previous studies have shown that HIFU, when targeted on fetal rat and mice bones. resulted in hemorrhage. However, the mechanism responsible has not been identified. In this study, we looked at ultrasound parameters related to hemorrhage in an effort to better understand the mechanism. METHODS: Brazilian opossum pups (7-8 postnatal days) were exposed to a 1.1-MHz f/1 spherically focused transducer (6.3 cm focal length). Four treatment groups of n = 14 and a control group of n = 14 were exposed to rarefactional pressures of 3.6 to 6 MPa with spatial-peak temporal average intensity values of 5.4 to 10.8 W/cm(2). The pulse repetition frequency was varied from 500 to 1000 Hz with exposure durations of 1 to 4 minutes. RESULTS: Four groups with sample sizes of 14 had hemorrhage percentages of 43%, 36%, 29%, and 36%, respectively. Hemorrhage occurrence and size were found to correlate strongly with the nonlinear product of energy density and number of pulses, with correlation values of 0.92 and 0.97, respectively. CONCLUSIONS: The dependence of hemorrhage on energy density and the number of pulses suggests that the hemorrhage may be due to high-stress, low-cycle mechanical fatigue damage. Hence, for therapeutic applications, the product of energy density and number of pulses should not exceed a certain predetermined limit.


Assuntos
Hemorragia Cerebral/etiologia , Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos , Exposição à Radiação/análise , Lesões por Radiação/etiologia , Crânio/cirurgia , Ondas Ultrassônicas/efeitos adversos , Animais , Hemorragia Cerebral/patologia , Relação Dose-Resposta à Radiação , Gambás , Osteotomia/efeitos adversos , Doses de Radiação , Lesões por Radiação/patologia , Crânio/efeitos da radiação , Estatística como Assunto
12.
Sci Rep ; 13(1): 16450, 2023 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-37777523

RESUMO

Post-operative urinary retention is a medical condition where patients cannot urinate despite having a full bladder. Ultrasound imaging of the bladder is used to estimate urine volume for early diagnosis and management of urine retention. Moreover, the use of bladder ultrasound can reduce the need for an indwelling urinary catheter and the risk of catheter-associated urinary tract infection. Wearable ultrasound devices combined with machine-learning based bladder volume estimation algorithms reduce the burdens of nurses in hospital settings and improve outpatient care. However, existing algorithms are memory and computation intensive, thereby demanding the use of expensive GPUs. In this paper, we develop and validate a low-compute memory-efficient deep learning model for accurate bladder region segmentation and urine volume calculation. B-mode ultrasound bladder images of 360 patients were divided into training and validation sets; another 74 patients were used as the test dataset. Our 1-bit quantized models with 4-bits and 6-bits skip connections achieved an accuracy within [Formula: see text] and [Formula: see text], respectively, of a full precision state-of-the-art neural network (NN) without any floating-point operations and with an [Formula: see text] and [Formula: see text] reduction in memory requirements to fit under 150 kB. The means and standard deviations of the volume estimation errors, relative to estimates from ground-truth clinician annotations, were [Formula: see text] ml and [Formula: see text] ml, respectively. This lightweight NN can be easily integrated on the wearable ultrasound device for automated and continuous monitoring of urine volume. Our approach can potentially be extended to other clinical applications, such as monitoring blood pressure and fetal heart rate.


Assuntos
Bexiga Urinária , Retenção Urinária , Humanos , Bexiga Urinária/diagnóstico por imagem , Algoritmos , Redes Neurais de Computação , Ultrassonografia/métodos , Retenção Urinária/diagnóstico por imagem
13.
Sci Adv ; 9(44): eadi6129, 2023 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-37910613

RESUMO

Acoustic beam shaping with high degrees of freedom is critical for applications such as ultrasound imaging, acoustic manipulation, and stimulation. However, the ability to fully control the acoustic pressure profile over its propagation path has not yet been achieved. Here, we demonstrate an acoustic diffraction-resistant adaptive profile technology (ADAPT) that can generate a propagation-invariant beam with an arbitrarily desired profile. By leveraging wave number modulation and beam multiplexing, we develop a general framework for creating a highly flexible acoustic beam with a linear array ultrasonic transducer. The designed acoustic beam can also maintain the beam profile in lossy material by compensating for attenuation. We show that shear wave elasticity imaging is an important modality that can benefit from ADAPT for evaluating tissue mechanical properties. Together, ADAPT overcomes the existing limitation of acoustic beam shaping and can be applied to various fields, such as medicine, biology, and material science.


Assuntos
Acústica , Transdutores , Ultrassonografia/métodos , Elasticidade , Ciência dos Materiais
14.
J Neural Eng ; 20(4)2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-37279730

RESUMO

Peripheral neuroregeneration research and therapeutic options are expanding exponentially. With this expansion comes an increasing need to reliably evaluate and quantify nerve health. Valid and responsive measures that can serve as biomarkers of the nerve status are essential for both clinical and research purposes for diagnosis, longitudinal follow-up, and monitoring the impact of any intervention. Furthermore, such biomarkers can elucidate regeneration mechanisms and open new avenues for research. Without these measures, clinical decision-making falls short, and research becomes more costly, time-consuming, and sometimes infeasible. As a companion to Part 2, which is focused on non-invasive imaging, Part 1 of this two-part scoping review systematically identifies and critically examines many current and emerging neurophysiological techniques that have the potential to evaluate peripheral nerve health, particularly from the perspective of regenerative therapies and research.


Assuntos
Tecido Nervoso , Neurofisiologia , Neurofisiologia/métodos , Nervos Periféricos , Regeneração Nervosa
15.
J Neural Eng ; 20(4)2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-37369193

RESUMO

Peripheral neuroregenerative research and therapeutic options are expanding exponentially. With this expansion comes an increasing need to reliably evaluate and quantify nerve health. Valid and responsive measures of the nerve status are essential for both clinical and research purposes for diagnosis, longitudinal follow-up, and monitoring the impact of any intervention. Furthermore, novel biomarkers can elucidate regenerative mechanisms and open new avenues for research. Without such measures, clinical decision-making is impaired, and research becomes more costly, time-consuming, and sometimes infeasible. Part 1 of this two-part scoping review focused on neurophysiology. In part 2, we identify and critically examine many current and emerging non-invasive imaging techniques that have the potential to evaluate peripheral nerve health, particularly from the perspective of regenerative therapies and research.


Assuntos
Regeneração Nervosa , Nervos Periféricos , Nervos Periféricos/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
16.
J Acoust Soc Am ; 132(3): 1319-24, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22978860

RESUMO

A key step toward implementing quantitative ultrasound techniques in a clinical setting is demonstrating that parameters such as the ultrasonic backscatter coefficient (BSC) can be accurately estimated independent of the clinical imaging system used. In previous studies, agreement in BSC estimates for well characterized phantoms was demonstrated across different laboratory systems. The goal of this study was to compare the BSC estimates of a tissue mimicking sample measured using four clinical scanners, each providing RF echo data in the 1-15 MHz frequency range. The sample was previously described and characterized with single-element transducer systems. Using a reference phantom for analysis, excellent quantitative agreement was observed across the four array-based imaging systems for BSC estimates. Additionally, the estimates from data acquired with the clinical systems agreed with theoretical predictions and with estimates from laboratory measurements using single-element transducers.


Assuntos
Imagens de Fantasmas , Ultrassom/instrumentação , Ultrassonografia/instrumentação , Ágar , Desenho de Equipamento , Géis , Vidro , Modelos Teóricos , Espalhamento de Radiação , Processamento de Sinais Assistido por Computador , Transdutores
17.
Ultrasound Med Biol ; 48(8): 1547-1554, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35660106

RESUMO

To develop an ultrasound-based machine learning classifier to diagnose benignity within indeterminate thyroid nodules (ITNs) by fine-needle aspiration, 180 patients with 194 ITNs (Bethesda classes III, IV and V) undergoing surgery over a 5-y study period were analyzed. The data set was randomly divided into training and testing data sets with 155 and 39 ITNs, respectively. All nodules were evaluated by ultrasound using the American College of Radiology Thyroid Imaging Reporting and Data System by manually scoring composition, echogenicity, shape, margin and echogenic foci. Nodule size, participant age and patient sex were recorded. A support vector machine (SVM) model with a cost-sensitive approach was developed using the aforementioned eight parameters with surgical histopathology as the reference standard. Surgical pathology determined 90 (46.4%) ITNs were malignant and 104 (53.6%) were benign. The SVM model classified 14 nodules as benign in the testing data set, of which 13 were correct (sensitivity = 93.8%, specificity = 56.5%). Considering malignancy prevalence by Bethesda group, the negative predictive values of this model for Bethesda III and IV categories were 93.9% and 93. 8%, respectively. The high negative predictive value of the SVM ultrasound-based model suggests a pathway by which surgical excision of Bethesda III and IV ITNs classified as benign may be avoided.


Assuntos
Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Biópsia por Agulha Fina , Humanos , Aprendizado de Máquina , Estudos Retrospectivos , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/patologia
18.
Comput Biol Med ; 148: 105891, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35932729

RESUMO

Deep learning has been widely utilized for medical image segmentation. The most commonly used U-Net and its variants often share two common characteristics but lack solid evidence for the effectiveness. First, each block (i.e., consecutive convolutions of feature maps of the same resolution) outputs feature maps from the last convolution, limiting the variety of the receptive fields. Second, the network has a symmetric structure where the encoder and the decoder paths have similar numbers of channels. We explored two novel revisions: a stacked dilated operation that outputs feature maps from multi-scale receptive fields to replace the consecutive convolutions; an asymmetric architecture with fewer channels in the decoder path. Two novel models were developed: U-Net using the stacked dilated operation (SDU-Net) and asymmetric SDU-Net (ASDU-Net). We used both publicly available and private datasets to assess the efficacy of the proposed models. Extensive experiments confirmed SDU-Net outperformed or achieved performance similar to the state-of-the-art while using fewer parameters (40% of U-Net). ASDU-Net further reduced the model parameters to 20% of U-Net with performance comparable to SDU-Net. In conclusion, the stacked dilated operation and the asymmetric structure are promising for improving the performance of U-Net and its variants.


Assuntos
Processamento de Imagem Assistida por Computador , Redes Neurais de Computação
19.
Diagnostics (Basel) ; 12(12)2022 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-36553220

RESUMO

Antral follicle Count (AFC) is a non-invasive biomarker used to assess ovarian reserves through transvaginal ultrasound (TVUS) imaging. Antral follicles' diameter is usually in the range of 2-10 mm. The primary aim of ovarian reserve monitoring is to measure the size of ovarian follicles and the number of antral follicles. Manual follicle measurement is inhibited by operator time, expertise and the subjectivity of delineating the two axes of the follicles. This necessitates an automated framework capable of quantifying follicle size and count in a clinical setting. This paper proposes a novel Harmonic Attention-based U-Net network, HaTU-Net, to precisely segment the ovary and follicles in ultrasound images. We replace the standard convolution operation with a harmonic block that convolves the features with a window-based discrete cosine transform (DCT). Additionally, we proposed a harmonic attention mechanism that helps to promote the extraction of rich features. The suggested technique allows for capturing the most relevant features, such as boundaries, shape, and textural patterns, in the presence of various noise sources (i.e., shadows, poor contrast between tissues, and speckle noise). We evaluated the proposed model on our in-house private dataset of 197 patients undergoing TransVaginal UltraSound (TVUS) exam. The experimental results on an independent test set confirm that HaTU-Net achieved a Dice coefficient score of 90% for ovaries and 81% for antral follicles, an improvement of 2% and 10%, respectively, when compared to a standard U-Net. Further, we accurately measure the follicle size, yielding the recall, and precision rates of 91.01% and 76.49%, respectively.

20.
IEEE Access ; 8: 76276-76286, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32612897

RESUMO

Sparse arrays reduce the number of active channels that effectively increases the inter-element spacing. Large inter-element spacing results in grating lobe artifacts degrading the ultrasound image quality and reducing the contrast-to-noise ratio. A deep learning-based custom algorithm is proposed to estimate inactive channel data in periodic sparse arrays. The algorithm uses data from multiple active channels to estimate inactive channels. The estimated inactive channel data effectively reduces the inter-element spacing for beamforming, thus suppressing the grating lobes. Estimated inactive element channel data was combined with active element channel data resulting in a pseudo fully sampled array. The channel data was beamformed using a simple delay-and-sum method and compared with the sparse array and fully sampled array. The performance of the algorithm was validated using a wire target in a water tank, multi-purpose tissue-mimicking phantom, and in-vivo carotid data. Grating lobes suppression up to 15.25 dB was observed with an increase in contrast-to-noise (CNR) for the pseudo fully sampled array. Hypoechoic regions showed more improvement in CNR than hyperechoic regions. Root-mean-square error for unwrapped phase between fully sampled array and the pseudo fully sampled array was low, making the estimated data suitable for Doppler and elastography applications. Speckle pattern was also preserved; thus, the estimated data can also be used for quantitative ultrasound applications. The algorithm can improve the quality of sparse array images and has applications in small scale ultrasound devices and 2D arrays.