Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Pathol ; 254(2): 147-158, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33904171

RESUMO

Artificial intelligence (AI)-based systems applied to histopathology whole-slide images have the potential to improve patient care through mitigation of challenges posed by diagnostic variability, histopathology caseload, and shortage of pathologists. We sought to define the performance of an AI-based automated prostate cancer detection system, Paige Prostate, when applied to independent real-world data. The algorithm was employed to classify slides into two categories: benign (no further review needed) or suspicious (additional histologic and/or immunohistochemical analysis required). We assessed the sensitivity, specificity, positive predictive values (PPVs), and negative predictive values (NPVs) of a local pathologist, two central pathologists, and Paige Prostate in the diagnosis of 600 transrectal ultrasound-guided prostate needle core biopsy regions ('part-specimens') from 100 consecutive patients, and to ascertain the impact of Paige Prostate on diagnostic accuracy and efficiency. Paige Prostate displayed high sensitivity (0.99; CI 0.96-1.0), NPV (1.0; CI 0.98-1.0), and specificity (0.93; CI 0.90-0.96) at the part-specimen level. At the patient level, Paige Prostate displayed optimal sensitivity (1.0; CI 0.93-1.0) and NPV (1.0; CI 0.91-1.0) at a specificity of 0.78 (CI 0.64-0.89). The 27 part-specimens considered by Paige Prostate as suspicious, whose final diagnosis was benign, were found to comprise atrophy (n = 14), atrophy and apical prostate tissue (n = 1), apical/benign prostate tissue (n = 9), adenosis (n = 2), and post-atrophic hyperplasia (n = 1). Paige Prostate resulted in the identification of four additional patients whose diagnoses were upgraded from benign/suspicious to malignant. Additionally, this AI-based test provided an estimated 65.5% reduction of the diagnostic time for the material analyzed. Given its optimal sensitivity and NPV, Paige Prostate has the potential to be employed for the automated identification of patients whose histologic slides could forgo full histopathologic review. In addition to providing incremental improvements in diagnostic accuracy and efficiency, this AI-based system identified patients whose prostate cancers were not initially diagnosed by three experienced histopathologists. © 2021 The Authors. The Journal of Pathology published by John Wiley & Sons, Ltd. on behalf of The Pathological Society of Great Britain and Ireland.


Assuntos
Inteligência Artificial , Neoplasias da Próstata/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Biópsia , Biópsia com Agulha de Grande Calibre , Humanos , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Patologistas , Próstata/patologia , Neoplasias da Próstata/patologia
2.
Mod Pathol ; 33(10): 2058-2066, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32393768

RESUMO

Prostate cancer (PrCa) is the second most common cancer among men in the United States. The gold standard for detecting PrCa is the examination of prostate needle core biopsies. Diagnosis can be challenging, especially for small, well-differentiated cancers. Recently, machine learning algorithms have been developed for detecting PrCa in whole slide images (WSIs) with high test accuracy. However, the impact of these artificial intelligence systems on pathologic diagnosis is not known. To address this, we investigated how pathologists interact with Paige Prostate Alpha, a state-of-the-art PrCa detection system, in WSIs of prostate needle core biopsies stained with hematoxylin and eosin. Three AP-board certified pathologists assessed 304 anonymized prostate needle core biopsy WSIs in 8 hours. The pathologists classified each WSI as benign or cancerous. After ~4 weeks, pathologists were tasked with re-reviewing each WSI with the aid of Paige Prostate Alpha. For each WSI, Paige Prostate Alpha was used to perform cancer detection and, for WSIs where cancer was detected, the system marked the area where cancer was detected with the highest probability. The original diagnosis for each slide was rendered by genitourinary pathologists and incorporated any ancillary studies requested during the original diagnostic assessment. Against this ground truth, the pathologists and Paige Prostate Alpha were measured. Without Paige Prostate Alpha, pathologists had an average sensitivity of 74% and an average specificity of 97%. With Paige Prostate Alpha, the average sensitivity for pathologists significantly increased to 90% with no statistically significant change in specificity. With Paige Prostate Alpha, pathologists more often correctly classified smaller, lower grade tumors, and spent less time analyzing each WSI. Future studies will investigate if similar benefit is yielded when such a system is used to detect other forms of cancer in a setting that more closely emulates real practice.


Assuntos
Aprendizado Profundo , Diagnóstico por Computador/métodos , Interpretação de Imagem Assistida por Computador/métodos , Patologia Clínica/métodos , Neoplasias da Próstata/diagnóstico , Biópsia com Agulha de Grande Calibre , Humanos , Masculino
3.
Nat Med ; 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39039250

RESUMO

The analysis of histopathology images with artificial intelligence aims to enable clinical decision support systems and precision medicine. The success of such applications depends on the ability to model the diverse patterns observed in pathology images. To this end, we present Virchow, the largest foundation model for computational pathology to date. In addition to the evaluation of biomarker prediction and cell identification, we demonstrate that a large foundation model enables pan-cancer detection, achieving 0.95 specimen-level area under the (receiver operating characteristic) curve across nine common and seven rare cancers. Furthermore, we show that with less training data, the pan-cancer detector built on Virchow can achieve similar performance to tissue-specific clinical-grade models in production and outperform them on some rare variants of cancer. Virchow's performance gains highlight the value of a foundation model and open possibilities for many high-impact applications with limited amounts of labeled training data.

4.
Cancer Res ; 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39106449

RESUMO

Artificial intelligence (AI)-systems can improve cancer diagnosis, yet their development often relies on subjective histological features as ground truth for training. Here, we developed an AI-model applied to histological whole-slide images (WSIs) using CDH1 bi-allelic mutations, pathognomonic for invasive lobular carcinoma (ILC) in breast neoplasms, as ground truth. The model accurately predicted CDH1 bi-allelic mutations (accuracy=0.95) and diagnosed ILC (accuracy=0.96). A total of 74% of samples classified by the AI-model as having CDH1 bi-allelic mutations but lacking these alterations displayed alternative CDH1 inactivating mechanisms, including a deleterious CDH1 fusion gene and non-coding CDH1 genetic alterations. Analysis of internal and external validation cohorts demonstrated 0.95 and 0.89 accuracy for ILC diagnosis, respectively. The latent features of the AI-model correlated with human-explainable histopathologic features. Taken together, this study reports the construction of an AI-algorithm trained using a genetic rather than histologic ground truth that can robustly classify ILCs and uncover CDH1 inactivating mechanisms, providing the basis for orthogonal ground truth utilization for development of diagnostic AI-models applied to WSI.

5.
Arch Pathol Lab Med ; 147(10): 1178-1185, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-36538386

RESUMO

CONTEXT.­: Prostate cancer diagnosis rests on accurate assessment of tissue by a pathologist. The application of artificial intelligence (AI) to digitized whole slide images (WSIs) can aid pathologists in cancer diagnosis, but robust, diverse evidence in a simulated clinical setting is lacking. OBJECTIVE.­: To compare the diagnostic accuracy of pathologists reading WSIs of prostatic biopsy specimens with and without AI assistance. DESIGN.­: Eighteen pathologists, 2 of whom were genitourinary subspecialists, evaluated 610 prostate needle core biopsy WSIs prepared at 218 institutions, with the option for deferral. Two evaluations were performed sequentially for each WSI: initially without assistance, and immediately thereafter aided by Paige Prostate (PaPr), a deep learning-based system that provides a WSI-level binary classification of suspicious for cancer or benign and pinpoints the location that has the greatest probability of harboring cancer on suspicious WSIs. Pathologists' changes in sensitivity and specificity between the assisted and unassisted modalities were assessed, together with the impact of PaPr output on the assisted reads. RESULTS.­: Using PaPr, pathologists improved their sensitivity and specificity across all histologic grades and tumor sizes. Accuracy gains on both benign and cancerous WSIs could be attributed to PaPr, which correctly classified 100% of the WSIs showing corrected diagnoses in the PaPr-assisted phase. CONCLUSIONS.­: This study demonstrates the effectiveness and safety of an AI tool for pathologists in simulated diagnostic practice, bridging the gap between computational pathology research and its clinical application, and resulted in the first US Food and Drug Administration authorization of an AI system in pathology.


Assuntos
Inteligência Artificial , Neoplasias da Próstata , Masculino , Humanos , Próstata/patologia , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Biópsia por Agulha
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA