Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38696701

RESUMO

AIMS: Women have been historically underrepresented in implantable cardioverter-defibrillator (ICD) trials. No data on sex differences regarding subcutaneous ICDs (S-ICD) carriers have been described. Aim of our study was to investigate sex-related differences among unselected S-ICD recipients. METHODS AND RESULTS: Consecutive patients enrolled in the multicentre, international i-SUSI registry were analysed. Comparisons between sexes were performed using a 1:1 propensity matching adjusted analysis for age, body mass index (BMI), left ventricular function, and substrate. The primary outcome was the rate of appropriate shocks during follow-up. Inappropriate shocks and other device-related complications were deemed secondary outcomes. A total of 1698 patients were extracted from the i-SUSI registry; 399 (23.5%) were females. After propensity matching, two cohorts of 374 patients presenting similar baseline characteristics were analysed. Despite similar periprocedural characteristics and a matched BMI, women resulted at lower risk of conversion failure as per PRAETORIAN score (73.4% vs. 81.3%, P = 0.049). Over a median follow-up time of 26.5 [12.7-42.5] months, appropriate shocks were more common in the male cohort (rate/year 3.4% vs. 1.7%; log-rank P = 0.049), while no significant differences in device-related complications (rate/year: 6.3% vs. 5.8%; log-rank P = 0.595) and inappropriate shocks (rate/year: 4.3% vs. 3.1%; log-rank P = 0.375) were observed. After controlling for confounders, sex remained significantly associated with the primary outcome (aHR 1.648; CI 0.999-2.655, P = 0.048), while not resulting predictor of inappropriate shocks and device-related complications. CONCLUSION: In a propensity-matched cohort of S-ICD recipients, women are less likely to experience appropriate ICD therapy, while not showing higher risk of device-related complications. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT0473876.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Pontuação de Propensão , Sistema de Registros , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Fatores Sexuais , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Arritmias Cardíacas/terapia , Medição de Risco , Europa (Continente) , Fatores de Tempo , Morte Súbita Cardíaca/prevenção & controle
2.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584394

RESUMO

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cardioversão Elétrica/efeitos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
3.
Herz ; 49(3): 233-246, 2024 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-38709278

RESUMO

Cardiac device therapy provides not only treatment options for bradyarrhythmia but also advanced treatment for heart failure and preventive measures against sudden cardiac death. In heart failure treatment it enables synergistic reverse remodelling and reduces pharmacological side effects. Cardiac resynchronization therapy (CRT) has revolutionized the treatment of reduced left ventricular ejection fraction (LVEF) and left bundle branch block by decreasing the mortality and morbidity with improvement of the quality of life and resilience. Conduction system pacing (CSP) as an alternative method of physiological stimulation can improve heart function and reduce the risk of pacemaker-induced cardiomyopathy. Leadless pacers and subcutaneous/extravascular defibrillators offer less invasive options with lower complication rates. The prevention of infections through preoperative and postoperative strategies enhances the safety of these therapies.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Morte Súbita Cardíaca/prevenção & controle , Medicina Baseada em Evidências , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/prevenção & controle , Marca-Passo Artificial , Resultado do Tratamento
4.
N Engl J Med ; 383(6): 526-536, 2020 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-32757521

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies. METHODS: We conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD. The primary end point was the composite of device-related complications and inappropriate shocks; the noninferiority margin for the upper boundary of the 95% confidence interval for the hazard ratio (subcutaneous ICD vs. transvenous ICD) was 1.45. A superiority analysis was prespecified if noninferiority was established. Secondary end points included death and appropriate shocks. RESULTS: A total of 849 patients (426 in the subcutaneous ICD group and 423 in the transvenous ICD group) were included in the analyses. At a median follow-up of 49.1 months, a primary end-point event occurred in 68 patients in the subcutaneous ICD group and in 68 patients in the transvenous ICD group (48-month Kaplan-Meier estimated cumulative incidence, 15.1% and 15.7%, respectively; hazard ratio, 0.99; 95% confidence interval [CI], 0.71 to 1.39; P = 0.01 for noninferiority; P = 0.95 for superiority). Device-related complications occurred in 31 patients in the subcutaneous ICD group and in 44 in the transvenous ICD group (hazard ratio, 0.69; 95% CI, 0.44 to 1.09); inappropriate shocks occurred in 41 and 29 patients, respectively (hazard ratio, 1.43; 95% CI, 0.89 to 2.30). Death occurred in 83 patients in the subcutaneous ICD group and in 68 in the transvenous ICD group (hazard ratio, 1.23; 95% CI, 0.89 to 1.70); appropriate shocks occurred in 83 and 57 patients, respectively (hazard ratio, 1.52; 95% CI, 1.08 to 2.12). CONCLUSIONS: In patients with an indication for an ICD but no indication for pacing, the subcutaneous ICD was noninferior to the transvenous ICD with respect to device-related complications and inappropriate shocks. (Funded by Boston Scientific; PRAETORIAN ClinicalTrials.gov number, NCT01296022.).


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Idoso , Cardiomiopatias/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Eletrodos Implantados/efeitos adversos , Falha de Equipamento , Feminino , Seguimentos , Cardiopatias/terapia , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Desenho de Prótese
5.
Pacing Clin Electrophysiol ; 45(5): 639-648, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35262210

RESUMO

BACKGROUND: Cardiac contractility modulation (CCM), being reserved for patients with symptomatic chronic heart failure (HF) and narrow QRS complex under guideline directed medical therapy, can recover initially reduced left ventricular ejection fraction (LVEF); however, the influence of pre-implantation LVEF on long-term outcomes is not fully understood. This study aimed to compare the effects of lower and higher preimplantation LVEF on long-term outcomes in CCM-therapy. METHODS: One-hundred seventy-two patients from our single-centre registry were retrospectively included (2002-2019). Follow-up data were collected up to 5 years after implantation. Patients were divided into Group 1 (baseline LVEF≤ 30%) and Group 2 (≥ 31%). Both groups were compared based on differences in survival, echocardiographic- and clinical parameters including LVEF, tricuspid annular plane systolic excursion (TAPSE), NYHA class or Minnesota living with heart failure questionnaire-score (MLWHFQ). RESULTS: 11% of the patients did have a LVEF ≥31%. Mean LVEF ± SD for both groups were 21.98 ± 5.4 versus 35.2 ± 3.7%, respectively. MLWHFQ (47 ± 21.2 vs. 42±21.4) and mean peak oxygen consumption (VO2, 13.6 ± 4.1 vs. 12.7 ± 2.8 ml/kg/min) were comparable between both groups. LVEF-grouping did not influence survival. Lower baseline LVEF resulted in significantly better recovery of echocardiographic parameters such as LVEF and TAPSE. Irrespective from baseline LVEF, both groups showed nearly comparable improvements for clinical parameters like NYHA-class and MLWHFQ. CONCLUSION: Long-term biventricular systolic recovery potential in CCM-therapy might be better for preimplantation LVEF values ≤30%, whereas clinical parameters such as NYHA-class can improve irrespective from baseline LVEF.


Assuntos
Insuficiência Cardíaca , Função Ventricular Esquerda , Antiarrítmicos , Insuficiência Cardíaca/terapia , Humanos , Contração Miocárdica , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento
6.
Europace ; 22(5): 761-768, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32106296

RESUMO

AIMS: Inappropriate shocks (IAS) remain a challenge for patients and physicians after implantation of the subcutaneous implantable cardioverter-defibrillator (S-ICD). The aims were to assess and characterize different patterns of IAS. METHODS AND RESULTS: Two hundred and thirty-nine patients were implanted with an S-ICD between 2010 and 2018 for primary and secondary prevention. Follow-up data of at least 6 months were analysed. During a mean follow-up of 34.9 ± 16.0 months, a total of 73 shocks occurred in 38 patients (6%). Forty-three (59%) shocks were considered appropriate due to ventricular tachycardia/ventricular fibrillation, while 30 (41%) were inappropriate and occurred in 19 patients (8%). Myopotentials/noise was the most frequent cause of inappropriate shocks (n = 8), followed by T-wave oversensing (n = 6) and undersensing of the QRS, resulting in adaptation of the automatic gain control and inappropriate shock (n = 5). Seventy-four percent of all IAS occurred on the primary vector, while no IAS occurred on the alternate vector. In seven of eight patients (88%), IAS related to myopotentials have occurred on the primary sensing vector. Multivariate analysis identified taller patients, primary sensing vector and first-generation S-ICD device as predictors for IAS. SMART pass effectively reduced the occurrence of IAS in the second-generation S-ICD system. CONCLUSION: Inappropriate therapies are less frequently observed on the alternate vector. The primary vector seems to be unfavourable with regard to oversensing caused by myopotentials. Inappropriate shocks were associated with an increased rate of rehospitalization but not mortality. These observations have implications for the prevention of inappropriate S-ICD shocks.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Arritmias Cardíacas , Desfibriladores Implantáveis/efeitos adversos , Humanos , Incidência , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/prevenção & controle , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/terapia
7.
J Vasc Res ; 56(2): 92-96, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31079118

RESUMO

PURPOSE: Dronedarone is a multichannel-blocking antiarrhythmic drug for the treatment of atrial fibrillation. Observational data hypothesized a cardioprotective effect. In an in vitro endothelial cell-platelet model, we evaluated the molecular atheroprotective effects of dronedarone. METHODS: Following a 24-h incubation of human umbilical vein endothelial cells (HUVECs) with dronedarone (concentration 50, 100, and 150 ng/mL), they were then stimulated for 1 h with lipopolysaccharide (LPS) and were subsequently incubated in direct contact with thrombin-activated platelets. After incubation, the expression of CD40L and CD62P on platelets, and the expression of ICAM-1, VCAM-1, urokinase-type plasminogen activator receptor (uPAR), and membrane type 1 matrix metalloproteinase (MT1-MMP) on endothelial cells were measured by flow cytometry. RESULTS: Preincubation with 150 ng/mL of dronedarone reduced the expression of uPAR on endothelial cells after proinflammatory stimulation with LPS and also by direct endothelial contact with activated platelets (p = 0.0038). In contrast, the expression of CD40L and CD62P on platelets after proinflammatory stimulation with thrombin was significantly increased through direct preincubation with 50/100/150 ng/mL of dronedarone. However, dronedarone had no effects on the expression of MT1-MMP and ICAM-1 in HUVECs. CONCLUSION: In this in vitro analysis, dronedarone directly increased platelet activation but showed significant direct effects on endothelial cells and indirect effects on platelets on selected markers of atherosclerosis.


Assuntos
Aterosclerose/tratamento farmacológico , Plaquetas/efeitos dos fármacos , Fármacos Cardiovasculares/farmacologia , Dronedarona/farmacologia , Células Endoteliais da Veia Umbilical Humana/efeitos dos fármacos , Ativação Plaquetária/efeitos dos fármacos , Receptores de Ativador de Plasminogênio Tipo Uroquinase/metabolismo , Aterosclerose/metabolismo , Plaquetas/metabolismo , Ligante de CD40/metabolismo , Células Cultivadas , Citoproteção , Células Endoteliais da Veia Umbilical Humana/metabolismo , Humanos , Lipopolissacarídeos/farmacologia , Selectina-P/metabolismo , Transdução de Sinais
8.
BMC Cardiovasc Disord ; 18(1): 52, 2018 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-29544442

RESUMO

BACKGROUND: The wearable cardioverter-defibrillator (WCD) has emerged as a valuable tool to temporarily protect patients at risk for sudden cardiac death (SCD). The aim of this study was to determine the value of the WCD for therapy optimization of heart failure patients. METHODS: One hundred five consecutive patients that received WCD between 4/2012 and 9/2016 were included in the study. All patients were followed for clinical outcome and echocardiographic parameters during WCD therapy and had continued follow-up after WCD therapy, irrespective of subsequent implantable cardioverter-defibrillator (ICD) implantation. RESULTS: The most common indication for WCD were newly diagnosed ischemic (ICM) or non-ischemic cardiomyopathy (NICM) with left ventricular ejection fraction (LVEF) ≤35%. Mean WCD wear time was 68.8 ± 50.4 days with a mean daily use of 21.5 ± 3.5 h. Five patients (4.8%) received a total of five appropriate WCD shocks. During WCD wear, patients with ICM and NICM showed significant improvement in LVEF, reducing the proportion of patients with a need for primary preventive ICD implantation to 54.8% (ICM) and 48.8% (NICM). An ICD was finally implanted in 51.4% of the study patients (24 trans-venous ICDs, 30 subcutaneous ICDs). After discontinuation of WCD therapy, all patients were followed for a mean of 18.6 ± 12.3 months. 5.6% of patients with implanted ICDs received appropriate therapies. No patient with subcutaneous ICD needed change to a trans-venous device. None of the patients without an implanted ICD suffered from ventricular tachyarrhythmias and no patient died suddenly. In patients with NICM a significant LVEF improvement was observed during long-term follow-up (from 34.8 ± 11.1% to 41.0 ± 10.2%). CONCLUSIONS: WCD therapy successfully bridged all patients to either LVEF recovery or ICD implantation. Following WCD, ICD implantation could be avoided in almost half of the patients. In selected patients, prolongation of WCD therapy beyond 3 months might further prevent unnecessary ICD implantation. The WCD as an external monitoring system contributed important information to optimize device selection in patients that needed ICD implantation.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Adulto , Idoso , Tomada de Decisão Clínica , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Estudos Prospectivos , Implantação de Prótese/instrumentação , Recuperação de Função Fisiológica , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Procedimentos Desnecessários , Função Ventricular Esquerda
9.
Eur J Clin Invest ; 47(7): 477-485, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28517022

RESUMO

BACKGROUND: Early research has proposed that patients with Takotsubo syndrome (TTS) could have a higher mortality rate than the general population. Our study was conducted to determine the short- and long-term outcome of TTS patients associated with a significantly compromised left ventricular function on hospital admission. MATERIALS AND METHODS: Our institutional database constituted a collective of 112 patients diagnosed with TTS between 2003 and 2015. The patients were classified into two groups based on the left ventricular ejection fraction (LVEF), with those presenting with a LVEF > 35% on admission categorized into one group (n = 65, 58%) and those presenting with LVEF ≤ 35% (n=47, 42%) categorized into another group. The endpoint was the all-cause of mortality over a mean follow-up of 1529 ± 1121 days. RESULTS: Preliminary results indicated that patients with an EF ≤ 35% had a significantly greater risk of developing life-threatening arrhythmias, and were much more likely to suffer from cardiogenic shock. Patients often required varying forms of mechanical respiratory support. The in-hospital mortality, 30-day mortality, 1-year mortality and ongoing long-term mortality was significantly higher in TTS patients with an EF ≤ 35%. In a multivariate Cox regression analysis, an EF ≤ 35% (HR 3·3, 95% CI: 1·2-9·2, P < 0·05) was identified as a strong independent predictor of the primary endpoint. CONCLUSIONS: In-hospital events as well as short- and long-term mortality rates among TTS patients diagnosed with a significantly reduced LVEF on admission were significantly higher. There is an urgent need for randomized trials, which could help define uniform clinical management strategies for high risk TTS patients.


Assuntos
Cardiomiopatia de Takotsubo/terapia , Disfunção Ventricular Esquerda/terapia , Idoso , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Estimativa de Kaplan-Meier , Masculino , Prognóstico , Estudos Retrospectivos , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Volume Sistólico/fisiologia , Cardiomiopatia de Takotsubo/mortalidade , Disfunção Ventricular Esquerda/mortalidade
10.
Rev Cardiovasc Med ; 18(1): 1-13, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28509888

RESUMO

This article provides a technical description of common implant practice for delivery of cardiac contractility modulation (CCM) therapy to heart failure patients. As of September 2016, the authors of this article collectively have been involved with more than 400 system implantations in five medical centers, beginning with the advent of CCM therapy approximately 12 years ago. CCM therapy has been evaluated in a variety of studies, and was shown to be safe and effective and of benefit to patient quality of life and exercise capacity. As the use of CCM therapy continuously expands among medical centers in Europe, this article describes the technical and practical aspects of the implant procedure, and additional special technical cases based on our cumulative experience.


Assuntos
Terapia por Estimulação Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Contração Miocárdica , Terapia por Estimulação Elétrica/efeitos adversos , Desenho de Equipamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Recuperação de Função Fisiológica , Resultado do Tratamento
11.
Heart Vessels ; 32(5): 520-530, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27803954

RESUMO

This study aims to compare prospectively the differences of clinical outcomes being associated with a specific femoral closure (FC) compared to a radial compression (RC) device following percutaneous coronary interventions (PCI). This single-center, prospective observational study included consecutively 400 patients either treated by a specific FC (Angio-Seal™, St. Jude Medical, Inc., St. Paul, MN) or RC (TR Band®, Terumo Corporation, Tokyo, Japan) device following PCI. The primary outcome was to evaluate overall, access site and non-access site bleedings, the secondary outcome was major adverse cardiac events (MACE) occurring within 30 days of follow-up. 200 patients in each group (FC and RC group) were enrolled following PCI. The prevalence of overall bleedings was 56% in FC and 37% in RC group (p = 0.001). Access site bleedings were significantly higher in the FC (50%) compared to the RC (30%) group (p = 0.001). Most common type of access site bleeding consisted of hematomas (FC 45% vs. RC 27%, p = 0.001). Of these, intermediate and large hematomas were significantly higher in the FC group (p < 0.05). Surgical interventions following device-related bleedings were uncommon in both groups. No significant differences of MACE were observed in both treatment groups. Despite the use of a vascular closure device, the femoral arterial access is still associated with a higher rate of access site bleedings, consisting mostly of intermediate to large hematomas. No differences of MACE were found between FC versus RC following PCI at 30 days. TRIAL REGISTRY: ClinicalTrials.gov ( https://clinicaltrials.gov/ct2/show/NCT02455661 ).


Assuntos
Técnicas Hemostáticas/instrumentação , Isquemia Miocárdica/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Hemorragia Pós-Operatória/terapia , Idoso , Desenho de Equipamento , Feminino , Artéria Femoral , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Artéria Radial , Fatores de Risco , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 25(1): 29-35, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24118311

RESUMO

INTRODUCTION: A purely subcutaneous implantable cardioverter defibrillator (ICD) requires higher energy but may be an effective alternative to transvenous ICDs to deliver lifesaving therapies. OBJECTIVE: To identify combinations of anteroposterior subcutaneous shock pathways and waveforms with defibrillation efficacy comparable to transvenous ICDs. METHODS: Defibrillation testing was performed in 141 patients temporarily implanted with an active can emulator and subcutaneous coil electrodes. The patients were subdivided into 5 groups within 2 study phases. In all groups, a posterior electrode was positioned with its tip close to the spine. In the first study phase, 2 different can locations were evaluated: (1) an inframammary pocket (IM-1-750), or (2) a conventional infraclavicular pocket (IC-1-750). In both cases, a 70 J biphasic shock was used (peak voltage 750 V; 270 µF capacitance). In the second phase, configuration IC-1-750 was enhanced by the addition of a second (parasternal) subcutaneous electrode (IC-2-750). Furthermore, the effects of a different 70 J shock waveform (1,000 V, 160 µF) were evaluated for configurations IM-1-750 and IC-2-750 (becoming IM-1-1000 and IC-2-1000). RESULTS: The proportion of patients satisfying a defibrillation safety margin test of 2 consecutive successes at ≤50 J was 74%, 11%, and 44%, respectively, for the IM-1-750, IC-1-750, and IC-2-750 configurations, and 93% and 86% for the IM-1-1000 and IC-2-1000 configurations. CONCLUSIONS: Defibrillation efficacy comparable to that of a transvenous system was achieved with an anteroposterior subcutaneous ICD configuration, with 160 µF capacitance, 1,000 V, and 70 J output. An infraclavicular pocket location becomes feasible if a parasternal subcutaneous coil is added.


Assuntos
Desfibriladores Implantáveis/normas , Cardioversão Elétrica/métodos , Cardioversão Elétrica/normas , Tela Subcutânea , Idoso , Cardioversão Elétrica/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tela Subcutânea/fisiologia
13.
Europace ; 16(8): 1205-9, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24706089

RESUMO

AIMS: Cardiac contractility modulation (CCM) is an electrical therapy for heart failure (HF) with reduced ejection fraction. Sinus rhythm is deemed necessary for effective treatment because the current CCM signal delivery algorithm requires sequential sensing of a p wave, followed by depolarizations at each ventricular lead. In case of atrial fibrillation (AF) CCM is inhibited. This study demonstrates the feasibility of CCM therapy in patients with permanent AF by circumventing the requirement for sensing of a natural p wave. METHODS AND RESULTS: Five CCM patients with AF received a pacemaker or implantable cardioverter/defibrillator (ICD) upgrade to cardiac resynchronization therapy (CRT) with low atrial sensitivity, which resulted in compulsory atrial stimulation followed by biventricular pacing. The CCM system recognized the atrial stimuli as p waves, which led to CCM signal delivery. Three patients developed permanent AF after a mean follow-up of 40 months of CCM therapy. Two patients had permanent AF at the time of CCM device implantation. All pacemaker or ICD devices were successfully upgraded to CRT. Cardiac resynchronization therapy stimulation rates of ≥96% and CCM stimulation rates between 60% and 95% were achieved. Clinical condition of the patients improved (mean NYHA class -0.7, left ventricular ejection fraction +2%, Minnesota living with HF questionnaire -15.6 points). CONCLUSION: CCM signal delivery is feasible in HF patients with permanent AF by sequential atrial-ventricular pacing, so that the atrial pacing spike is interpreted as a p wave by the CCM signal delivery algorithm. This experimental approach can be considered in individual cases. A new CCM algorithm, which does not require an atrial electrode, is desirable.


Assuntos
Fibrilação Atrial/complicações , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Contração Miocárdica , Volume Sistólico , Função Ventricular Esquerda , Idoso , Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Dispositivos de Terapia de Ressincronização Cardíaca , Eletrocardiografia , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
14.
J Electrocardiol ; 47(6): 936-40, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25201417

RESUMO

BACKGROUND AND PURPOSE: Cardiac contractility modulation (CCM) is an implantable device treatment for heart failure with reduced ejection fraction. CCM therapy improves patient functional status but its effect on intra-ventricular conduction remains unknown. METHODS: 70 patients treated with CCM between 12/2002 and 5/2013 had 12-vector-ECG recordings made at baseline and final follow-up visits. QRS complex duration was measured at each time point. RESULTS: Mean follow-up was 2.8 years. Mean QRS duration was unchanged from baseline (112.0 ms) to last follow up (112.9 ms, p=n.s.). These results are strikingly different from comparative published data of several studies with heart failure patients without CCM, consistently indicating an increase in QRS duration (6.0-23.4 ms) over a similar time period. CONCLUSIONS: CCM prevents chronic ventricular depolarization delay that occurs in heart failure and that is associated with poorer outcomes. This supports the safety of long-term CCM therapy and suggests a possible long-term benefit in maintaining QRS duration.


Assuntos
Estimulação Cardíaca Artificial/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/prevenção & controle , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Insuficiência Cardíaca/complicações , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicações
15.
Heart Rhythm ; 21(4): 410-418, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38246594

RESUMO

BACKGROUND: Outcome comparisons among subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients with nonischemic cardiomyopathies are scarce. OBJECTIVE: The aim of this study was to evaluate differences in device-related outcomes among S-ICD recipients with different structural substrates. METHODS: Patients enrolled in the i-SUSI (International SUbcutaneouS Implantable cardioverter defibrillator registry) project were grouped according to the underlying substrate (ischemic vs nonischemic) and subgrouped into dilated cardiomyopathy, hypertrophic cardiomyopathy, Brugada syndrome (BrS), arrhythmogenic right ventricular cardiomyopathy (ARVC). The main outcome of our study was to compare the rates of appropriate and inappropriate shocks and device-related complications. RESULTS: Among 1698 patients, the most common underlying substrate was ischemic (31.7%), followed by dilated cardiomyopathy (20.5%), BrS (10.8%), hypertrophic cardiomyopathy (8.5%), and ARVC (4.4%). S-ICD for primary prevention was more common in the nonischemic cohort (70.9% vs 65.4%; P = .037). Over a median (interquartile range) follow-up of 26.5 (12.6-42.8) months, no differences were observed in appropriate shocks between ischemic and nonischemic patients (4.8%/y vs 3.9%/y; log-rank, P = .282). ARVC (9.0%/y; hazard ratio [HR] 2.492; P = .001) and BrS (1.8%/y; HR 0.396; P = .008) constituted the groups with the highest and lowest rates of appropriate shocks, respectively. Device-related complications did not differ between groups (ischemic: 6.4%/y vs nonischemic: 6.1%/y; log-rank, P = .666), nor among underlying substrates (log-rank, P = .089). Nonischemic patients experienced higher rates of inappropriate shocks than did ischemic S-ICD recipients (4.4%/y vs 3.0%/y; log-rank, P = .043), with patients with ARVC (9.9%/y; P = .001) having the highest risk, even after controlling for confounders (adjusted HR 2.243; confidence interval 1.338-4.267; P = .002). CONCLUSION: Most S-ICD recipients were primary prevention nonischemic cardiomyopathy patients. Among those, patients with ARVC tend to receive the most frequent appropriate and inappropriate shocks and patients with BrS the least frequent appropriate shocks.


Assuntos
Displasia Arritmogênica Ventricular Direita , Cardiomiopatias , Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/terapia , Sistema de Registros , Resultado do Tratamento
16.
Int J Cardiol ; 400: 131807, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38272130

RESUMO

BACKGROUND: Left ventricular assist devices (LVADs) are an increasingly used strategy for the management of patients with advanced heart failure (HF). Subcutaneous implantable cardioverter defibrillator (S-ICD) might be a viable alternative to conventional ICDs with a lower risk of short- and long-term of device-related complications and infections.The aim of this multicenter study was to evaluate the outcomes and management of S-ICD recipients who underwent LVAD implantation. METHODS: The study population included patients with a preexisting S-ICD who underwent LVAD implantation for advanced HF despite optimal medical therapy. RESULTS: The study population included 30 patients (25 male; median age 45 [38-52] years).The HeartMate III was the most common LVAD type. Median follow-up in the setting of concomitant use of S-ICDs and LVADs was 7 months (1-20).There were no reports of inability to interrogate S-ICD systems in this population. Electromagnetic interference (EMI) occurred in 21 (70%) patients. The primary sensing vector was the one most significantly involved in determining EMI. Twenty-seven patients (90%) remained eligible for S-ICD implantation with at least one optimal sensing vector. The remaining 3 patients (10%) were ineligible for S-ICD after attempts of reprogramming of sensing vectors. Six patients (20%) experienced inappropriate shocks (IS) due to EMI. Six patients (20%) experienced appropriate shocks. No S-ICD extraction because of need for antitachycardia pacing, ineffective therapy or infection was reported. CONCLUSIONS: Concomitant use of LVAD and S-ICD is feasible in most patients. However, the potential risk of EMI oversensing, IS and undersensing in the post-operative period following LVAD implantation should be considered. Careful screening for EMI should be performed in all sensing vectors after LVAD implantation.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Marca-Passo Artificial , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Coração Auxiliar/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento
17.
Heart Rhythm ; 21(6): 836-844, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38336193

RESUMO

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Valor Preditivo dos Testes , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Cardioversão Elétrica/métodos , Estudos Prospectivos , Idoso , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Medição de Risco/métodos , Taquicardia Ventricular/terapia , Taquicardia Ventricular/fisiopatologia , Fibrilação Ventricular/terapia
19.
Sci Rep ; 12(1): 3203, 2022 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-35217697

RESUMO

Patients at high risk for sudden cardiac death (SCD) may benefit from wearable cardioverter defibrillators (WCD) by avoiding immediate implantable cardioverter defibrillator (ICD) implantation. Different factors play an important role including patient selection, compliance and optimal drug treatment. We aimed to present real world data from 4 centers from Germany and Switzerland. Between 04/2012 and 03/2019, 708 patients were included in this registry. Patients were followed up over a mean time of 28 ± 35.5 months. Outcome data including gender differences and different etiologies of cardiomyopathy were analyzed. Out of 708 patients (81.8% males, mean age 61.0 ± 14.6), 44.6% of patients had non-ischemic cardiomyopathy, 39.8% ischemic cardiomyopathy, 7.9% myocarditis, 5.4% prior need for ICD explantation and 2.1% channelopathy. The mean wear time of WCD was 21.2 ± 4.3 h per day. In 46% of patients, left ventricular ejection fraction (LVEF) was > 35% during follow-up. The younger the patient was, the higher the LVEF and the lower the wear hours per day were. The total shock rate during follow-up was 2.7%. Whereas an appropriate WCD shock was documented in 16 patients (2.2%), 3 patients received an inappropriate ICD shock (0.5%). During follow-up, implantation of a cardiac implantable electronic device was carried out in 34.5% of patients. When comparing German patients (n = 516) to Swiss patients (n = 192), Swiss patients presented with longer wear days (70.72 ± 49.47 days versus 58.06 ± 40.45 days; p = 0.001) and a higher ICD implantation rate compared to German patients (48.4% versus 29.3%; p = 0.001), although LVEF at follow-up was similar between both groups. Young age is a negative independent predictor for the compliance in this large registry. The most common indication for WCD was non-ischemic cardiomyopathy followed by ischemic cardiomyopathy. The compliance rate was generally high with a decrease of wear hours per day at younger age. Slight differences were found between Swiss and German patients, which might be related to differences in mentality for ICD implantation.


Assuntos
Cardiomiopatias , Desfibriladores Implantáveis , Isquemia Miocárdica , Dispositivos Eletrônicos Vestíveis , Idoso , Cardiomiopatias/complicações , Cardiomiopatias/terapia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Sistema de Registros , Volume Sistólico , Função Ventricular Esquerda , Dispositivos Eletrônicos Vestíveis/efeitos adversos
20.
Sci Rep ; 12(1): 20504, 2022 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-36443407

RESUMO

We hypothesized that myocardial septal scarring, assessed by cardiac magnetic resonance (CMR) using late gadolinium enhancement (LGE), at the site of cardiac contractility modulation (CCM) lead placement may predict treatment response. Eligible heart failure (HF) patients underwent LGE CMR imaging before CCM device implantation. The response to CCM therapy at follow-up was determined by a change in NYHA class and echocardiographic left ventricular ejection fraction (LVEF) assessment. Patients were classified as responders, if they showed an improvement in either NYHA class or improvement of LVEF by ≥ 5%. 58 patients were included. 67% of patients were classified as responders according to improved NYHA; 55% according to LVEF improvement. 74% of patients were responders if either NYHA class or LVEF improvement was observed. 90% of responders (according to NYHA class) showed septal LGE < 25% at septal position of the leads, while 44% of non-responders showed septal LGE > 25% (p < 0.01). In patients treated with CCM, an improvement of NYHA class was observed when leads were placed at myocardial segments with a CMR- LGE burden less than 25%.


Assuntos
Cicatriz , Insuficiência Cardíaca , Humanos , Cicatriz/diagnóstico por imagem , Volume Sistólico , Meios de Contraste , Função Ventricular Esquerda , Gadolínio , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA