Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 95(2): 319-328, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31696642

RESUMO

BACKGROUND: The diameter of balloons or stents is selected according to the estimated reference vessel diameter and do not adapt to the vessel anatomy. The aim of the present preclinical studies was to investigate a novel, vessel anatomy adjusting hypercompliant drug-coated balloon catheter (HCDCB). METHODS: Hypercompliant balloon membranes were coated in a constricted state with high drug density. Drug adherence was investigated in vitro, transfer to the porcine peripheral arteries and longitudinal distribution in vivo. In young domestic swine, neointimal proliferation was induced by vessel overstretch and continuous irritation by permanent stents. Uncoated hypercompliant balloons (HCB), and standard uncoated balloons and drug-coated balloons (DCB) served as controls. Efficacy was assessed by angiography, optical coherence tomography (OCT), and histomorphometry. RESULTS: HCDCB lost 18.0 ± 3.9% of dose during in vitro simulated delivery to the lesion. Drug transfer to the vessel wall was 13.9 ± 6.4% and drug concentration was 1,044 ± 529 ng/mg tissue. Four weeks after treatment, the histomorphometric neointimal area was smaller with HCDCB versus uncoated HCB (2.39 ± 0.55 mm2 vs. 3.26 ± 0.72 mm2 , p = .038) and area stenosis (OCT) was less (11.6 ± 6.9% vs. 24.7 ± 9.7%, p = .022). No premature death occurred and no in-life clinical symptoms or treatment-associated thrombi were observed. CONCLUSIONS: HCDCB were found to inhibit excessive neointimal proliferation. Balloon adaption to different vessel diameters and shapes may provide drug-delivery in irregular lumen and facilitate balloon selection.


Assuntos
Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Artéria Ilíaca , Paclitaxel/administração & dosagem , Dispositivos de Acesso Vascular , Angiografia , Angioplastia com Balão/efeitos adversos , Animais , Fármacos Cardiovasculares/toxicidade , Proliferação de Células , Desenho de Equipamento , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/patologia , Neointima , Paclitaxel/toxicidade , Sus scrofa , Fatores de Tempo , Tomografia de Coerência Óptica
2.
PLoS One ; 18(1): e0280206, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36706120

RESUMO

BACKGROUND: Long diseased vessel segments of peripheral arteries may display irregular shapes with different diameters. The aim of this study was to investigate inhibition of neointimal proliferation in porcine peripheral vessels with different diameters covered by one single hyper-compliant drug-coated balloon (HCDCB), compared to conventional drug-coated balloons (DCB), each selected according to the respective vessel diameter. METHODS AND RESULTS: Neointimal proliferation was stimulated in proximal and distal segments of the peripheral arteries by balloon overstretch and stent implantation. Inhibition of neointimal proliferation by one single HCDCB was compared to two vessel diameter-adjusted DCB per artery and to one single uncoated hyper-compliant balloon (HCB). Sixteen HCB, 16 HCDCB, and 32 DCB were used in 16 arteries each. Quantitative angiography (QA), optical coherence tomography (OCT) and histology showed a similar anti-restenotic effect for one HCDCB compared to two vessel diameter-adjusted DCB in narrow distal and wider proximal segments (QA diameter stenosis: 18.7±12.3% vs. 22.8±15.5%, p = 0.535; OCT area stenosis: 21.4±11.6% vs. 23.6±12.3%, p = 0.850; histomorphometry diameter stenosis: 27.5±7.1% vs. 26.9±8.0%, p = 0.952) and indicated significant inhibition of neointimal proliferation by HCDCB vs. uncoated HCB (QA diameter stenosis: 18.7±12.3% vs. 30.3±16.7%, p = 0.008; OCT area stenosis: 21.4±11.6% vs. 34.7±16.0%, p = 0.004; histomorphometry diameter stenosis: 27.5±7.1% vs. 32.5±8.5%, p = 0.038). CONCLUSIONS: HCDCB were found to be similar effective as DCB in inhibiting neointimal proliferation in vessel segments with different diameters. One single long HCDCB may allow for treatment of segments with variable diameters, and thus, replace the use of several vessel diameter-adjusted DCB.


Assuntos
Angioplastia com Balão , Paclitaxel , Suínos , Animais , Constrição Patológica/patologia , Paclitaxel/farmacologia , Vasos Coronários/patologia , Neointima/patologia , Proliferação de Células , Materiais Revestidos Biocompatíveis/farmacologia , Stents
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA