RESUMO
BACKGROUND AND PURPOSE: Given recent evidence suggesting the clot composition may be associated with revascularization outcomes and stroke etiology, clot composition research has been a topic of growing interest. It is currently unclear what effect, if any, pre-thrombectomy thrombolysis has on clot composition. Understanding this association is important as it is a potential confounding variable in clot composition research. We retrospectively evaluated the composition of retrieved clots from ischemic stroke patients who did and did not receive pre-treatment tPA to study the effect of tPA on clot composition. MATERIALS AND METHODS: Consecutive patients enrolled in the Stroke Thromboembolism Registry of Imaging and Pathology (STRIP) were included in this study. All patients underwent mechanical thrombectomy and retrieved clots were sent to a central core lab for processing. Histological analysis was performed using Martius Scarlett Blue (MSB) staining and area of the clot was also measured on the gross photos. Student's t test was used for continuous variables and chi-squared test for categorical variables. RESULTS: A total of 1430 patients were included in this study. Mean age was 68.4±13.5 years. Overall rate of TICI 2c/3 was 67%. A total of 517 patients received tPA (36%) and 913 patients did not (64%). Mean RBC density for the tPA group was 42.97±22.62% compared to 42.80±23.18% for the non-tPA group (P=0.89). Mean WBC density for the tPA group was 3.74±2.60% compared to 3.42±2.21% for the non-tPA group (P=0.012). Mean fibrin density for the tPA group was 26.52±15.81% compared to 26.53±15.34% for the non-tPA group (P=0.98). Mean platelet density for the tPA group was 26.22±18.60% compared to 26.55±19.47% for the non-tPA group (P=0.75). tPA group also had significantly smaller clot area compared to non-tPA group. CONCLUSIONS: Our study 1430 retrieved emboli and ischemic stroke patients shows no interaction between tPA administration and clot composition. These findings suggest that tPA does not result in any histological changes in clot composition.
Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/tratamento farmacológico , Humanos , AVC Isquêmico/diagnóstico , AVC Isquêmico/tratamento farmacológico , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/tratamento farmacológico , Trombectomia/efeitos adversos , Ativador de Plasminogênio Tecidual/efeitos adversosRESUMO
Background and Purpose- Nearly 30% of large vessel occlusion acute ischemic stroke clots are from an unknown source. We assessed histological clot composition in a series of patients with large vessel occlusion and investigated correlations between clot composition and stroke pathogenesis. Methods- As part of the multi-institutional STRIP registry (Stroke Thromboembolism Registry of Imaging and Pathology), consecutive emboli retrieved during mechanical thrombectomy were stained using Martius Scarlett Blue and analyzed using machine learning software. We assessed proportions of red blood cells, fibrin, platelets, and white blood cells. Correlations between clot components and stroke pathogenesis (large artery atherosclerosis, cardioembolism, and stroke of undetermined pathogenesis) were assessed using SPSS22. Results- One hundred five patients were included. The proportion of platelet-rich clots (55.0% versus 21.2%; P=0.005) and percentage of platelet content (22.1±4.2% versus 13.9±14.2%; P=0.03) was significantly higher in the large artery atherosclerosis group compared with the cardioembolic group. The proportion of platelet-rich clots (50.0% versus 21.2%; P=0.024) was also significantly higher in the cryptogenic group compared with cardioembolic cases. Large artery atherosclerosis and cryptogenic cases had a similar proportion of platelet-rich clots (55.0% versus 50.0%; P=0.636). There was no significant difference between stroke pathogenesis and the other major clot components. Conclusions- High platelet content of emboli is associated with a large artery atherosclerosis etiology of large vessel occlusion.
Assuntos
Arteriopatias Oclusivas/sangue , Plaquetas/patologia , Doenças Arteriais Cerebrais/sangue , Arteriosclerose Intracraniana/sangue , Embolia Intracraniana/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Contagem de Células Sanguíneas , Retração do Coágulo , Trombose Coronária/sangue , Feminino , Humanos , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Acidente Vascular Cerebral/sangue , Trombectomia , Tromboembolia/sangue , Tromboembolia/patologiaRESUMO
Background and Purpose- Mechanical thrombectomy has been shown to improve clinical outcomes in patients with acute ischemic stroke. However, the impact of balloon guide catheter (BGC) use is not well established. Methods- STRATIS (Systematic Evaluation of Patients Treated With Neurothrombectomy Devices for Acute Ischemic Stroke) was a prospective, multicenter study of patients with large vessel occlusion treated with the Solitaire stent retriever as first-line therapy. In this study, an independent core laboratory, blinded to the clinical outcomes, reviewed all procedures and angiographic data to classify procedural technique, target clot location, recanalization after each pass, and determine the number of stent retriever passes. The primary clinical end point was functional independence (modified Rankin Scale, 0-2) at 3 months as determined on-site, and the angiographic end point was first-pass effect (FPE) success rate from a single device attempt (modified Thrombolysis in Cerebral Infarction, ≥2c) as determined by a core laboratory. Achieving modified FPE (modified Thrombolysis in Cerebral Infarction, ≥2b) was also assessed. Comparisons of clinical outcomes were made between groups and adjusted for baseline and procedural characteristics. All participating centers received institutional review board approval from their respective institutions. Results- Adjunctive technique groups included BGC (n=445), distal access catheter (n=238), and conventional guide catheter (n=62). The BGC group had a higher rate of FPE following first pass (212/443 [48%]) versus conventional guide catheter (16/62 [26%]; P=0.001) and distal access catheter (83/235 [35%]; P=0.002). Similarly, the BGC group had a higher rate of modified FPE (294/443 [66%]) versus conventional guide catheter (26/62 [42%]; P<0.001) and distal access catheter (129/234 [55%]; P=0.003). The BGC group achieved the highest rate of functional independence (253/415 [61%]) versus conventional guide catheter (23/55 [42%]; P=0.007) and distal access catheter (113/218 [52%]; P=0.027). Final revascularization and mortality rates did not differ across the groups. Conclusions- BGC use was an independent predictor of FPE, modified FPE, and functional independence, suggesting that its routine use may improve the rates of early revascularization success and good clinical outcomes. Clinical Trial Registration- URL: https://www.clinicaltrials.gov . Unique identifier: NCT02239640.
Assuntos
Cateterismo/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Trombectomia/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/terapia , Angiografia Cerebral , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Stents , Resultado do TratamentoRESUMO
BACKGROUND: Endovascular treatment with mechanical thrombectomy (MT) is beneficial for patients with acute stroke suffering a large-vessel occlusion, although treatment efficacy is highly time-dependent. We hypothesized that interhospital transfer to endovascular-capable centers would result in treatment delays and worse clinical outcomes compared with direct presentation. METHODS: STRATIS (Systematic Evaluation of Patients Treated With Neurothrombectomy Devices for Acute Ischemic Stroke) was a prospective, multicenter, observational, single-arm study of real-world MT for acute stroke because of anterior-circulation large-vessel occlusion performed at 55 sites over 2 years, including 1000 patients with severe stroke and treated within 8 hours. Patients underwent MT with or without intravenous tissue plasminogen activator and were admitted to endovascular-capable centers via either interhospital transfer or direct presentation. The primary clinical outcome was functional independence (modified Rankin Score 0-2) at 90 days. We assessed (1) real-world time metrics of stroke care delivery, (2) outcome differences between direct and transfer patients undergoing MT, and (3) the potential impact of local hospital bypass. RESULTS: A total of 984 patients were analyzed. Median onset-to-revascularization time was 202.0 minutes for direct versus 311.5 minutes for transfer patients (P<0.001). Clinical outcomes were better in the direct group, with 60.0% (299/498) achieving functional independence compared with 52.2% (213/408) in the transfer group (odds ratio, 1.38; 95% confidence interval, 1.06-1.79; P=0.02). Likewise, excellent outcome (modified Rankin Score 0-1) was achieved in 47.4% (236/498) of direct patients versus 38.0% (155/408) of transfer patients (odds ratio, 1.47; 95% confidence interval, 1.13-1.92; P=0.005). Mortality did not differ between the 2 groups (15.1% for direct, 13.7% for transfer; P=0.55). Intravenous tissue plasminogen activator did not impact outcomes. Hypothetical bypass modeling for all transferred patients suggested that intravenous tissue plasminogen activator would be delayed by 12 minutes, but MT would be performed 91 minutes sooner if patients were routed directly to endovascular-capable centers. If bypass is limited to a 20-mile radius from onset, then intravenous tissue plasminogen activator would be delayed by 7 minutes and MT performed 94 minutes earlier. CONCLUSIONS: In this large, real-world study, interhospital transfer was associated with significant treatment delays and lower chance of good outcome. Strategies to facilitate more rapid identification of large-vessel occlusion and direct routing to endovascular-capable centers for patients with severe stroke may improve outcomes. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02239640.
Assuntos
Procedimentos Endovasculares , Isquemia/epidemiologia , Transferência de Pacientes/estatística & dados numéricos , Acidente Vascular Cerebral/epidemiologia , Trombectomia , Hospitais , Humanos , Isquemia/mortalidade , Isquemia/cirurgia , Estudos Prospectivos , Sistema de Registros , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/cirurgia , Análise de Sobrevida , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND AND PURPOSE: Mechanical thrombectomy with stent retrievers has become standard of care for treatment of acute ischemic stroke patients because of large vessel occlusion. The STRATIS registry (Systematic Evaluation of Patients Treated With Neurothrombectomy Devices for Acute Ischemic Stroke) aimed to assess whether similar process timelines, technical, and functional outcomes could be achieved in a large real world cohort as in the randomized trials. METHODS: STRATIS was designed to prospectively enroll patients treated in the United States with a Solitaire Revascularization Device and Mindframe Capture Low Profile Revascularization Device within 8 hours from symptom onset. The STRATIS cohort was compared with the interventional cohort of a previously published SEER patient-level meta-analysis. RESULTS: A total of 984 patients treated at 55 sites were analyzed. The mean National Institutes of Health Stroke Scale score was 17.3. Intravenous tissue-type plasminogen activator was administered in 64.0%. The median time from onset to arrival in the enrolling hospital, door to puncture, and puncture to reperfusion were 138, 72, and 36 minutes, respectively. The Core lab-adjudicated modified Thrombolysis in Cerebral Infarction ≥2b was achieved in 87.9% of patients. At 90 days, 56.5% achieved a modified Rankin Scale score of 0 to 2, all-cause mortality was 14.4%, and 1.4% suffered a symptomatic intracranial hemorrhage. The median time from emergency medical services scene arrival to puncture was 152 minutes, and each hour delay in this interval was associated with a 5.5% absolute decline in the likelihood of achieving modified Rankin Scale score 0 to 2. CONCLUSIONS: This largest-to-date Solitaire registry documents that the results of the randomized trials can be reproduced in the community. The decrease of clinical benefit over time warrants optimization of the system of care. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02239640.
Assuntos
Isquemia Encefálica/diagnóstico , Isquemia Encefálica/terapia , Trombólise Mecânica/normas , Sistema de Registros/normas , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/terapia , Idoso , Isquemia Encefálica/epidemiologia , Estudos de Coortes , Feminino , Humanos , Masculino , Trombólise Mecânica/métodos , Pessoa de Meia-Idade , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto/normas , Acidente Vascular Cerebral/epidemiologia , Tempo para o Tratamento/normas , Ativador de Plasminogênio Tecidual/administração & dosagem , Resultado do TratamentoRESUMO
BACKGROUND: Mechanical thrombectomy (MT) has become standard for large vessel occlusions, but rates of complete recanalization are suboptimal. Previous reports correlated radiographic signs with clot composition and a better response to specific techniques. Therefore, understanding clot composition may allow improved outcomes. METHODS: Clinical, imaging, and clot data from patients enrolled in the STRIP Registry from September 2016 to September 2020 were analyzed. Samples were fixed in 10% phosphate-buffered formalin and stained with hematoxylin-eosin and Martius Scarlett Blue. Percent composition, richness, and gross appearance were evaluated. Outcome measures included the rate of first-pass effect (FPE, modified Thrombolysis in Cerebral Infarction 2c/3) and the number of passes. RESULTS: A total of 1430 patients of mean±SD age 68.4±13.5 years (median (IQR) baseline National Institutes of Health Stroke Scale score 17.2 (10.5-23), IV-tPA use 36%, stent-retrievers (SR) 27%, contact aspiration (CA) 27%, combined SR+CA 43%) were included. The median (IQR) number of passes was 1 (1-2). FPE was achieved in 39.3% of the cases. There was no association between percent histological composition or clot richness and FPE in the overall population. However, the combined technique resulted in lower FPE rates for red blood cell (RBC)-rich (P<0.0001), platelet-rich (P=0.003), and mixed (P<0.0001) clots. Fibrin-rich and platelet-rich clots required a higher number of passes than RBC-rich and mixed clots (median 2 and 1.5 vs 1, respectively; P=0.02). CA showed a trend towards a higher number of passes with fibrin-rich clots (2 vs 1; P=0.12). By gross appearance, mixed/heterogeneous clots had lower FPE rates than red and white clots. CONCLUSIONS: Despite the lack of correlation between clot histology and FPE, our study adds to the growing evidence supporting the notion that clot composition influences recanalization treatment strategy outcomes.
RESUMO
BACKGROUND: Platelets and von Willebrand factor (vWF) are key components of acute ischemic stroke (AIS) emboli. We aimed to investigate the CD42b (platelets)/vWF expression, its association with stroke etiology and the impact these components may have on the clinical/procedural parameters. METHODS: CD42b/vWF immunostaining was performed on 288 emboli collected as part of the multicenter STRIP Registry. CD42b/VWF expression and distribution were evaluated. Student's t-test and χ2 test were performed as appropriate. RESULTS: The mean CD42b and VWF content in clots was 44.3% and 21.9%, respectively. There was a positive correlation between platelets and vWF (r=0.64, p<0.001**). We found a significantly higher vWF level in the other determined etiology (p=0.016*) and cryptogenic (p=0.049*) groups compared with cardioembolic etiology. No significant difference in CD42b content was found across the etiology subtypes. CD42b/vWF patterns were significantly associated with stroke etiology (p=0.006*). The peripheral pattern was predominant in atherosclerotic clots (36.4%) while the clustering (patchy) pattern was significantly associated with cardioembolic and cryptogenic origin (66.7% and 49.8%, respectively). The clots corresponding to other determined etiology showed mainly a diffuse pattern (28.1%). Two types of platelets were distinguished within the CD42b-positive clusters in all emboli: vWF-positive platelets were observed at the center, surrounded by vWF-negative platelets. Thrombolysis correlated with a high platelet content (p=0.03*). vWF-poor and peripheral CD42b/vWF pattern correlated with first pass effect (p=0.03* and p=0.04*, respectively). CONCLUSIONS: The vWF level and CD42b/vWF distribution pattern in emboli were correlated with AIS etiology and revascularization outcome. Platelet content was associated with response to thrombolysis.
Assuntos
AVC Isquêmico , Acidente Vascular Cerebral , Trombose , Humanos , Fator de von Willebrand/metabolismo , Plaquetas/metabolismo , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/metabolismo , Trombose/metabolismoRESUMO
BACKGROUND: Compositional and structural features of retrieved clots by thrombectomy can provide insight into improving the endovascular treatment of ischemic stroke. Currently, histological analysis is limited to quantification of compositions and qualitative description of the clot structure. We hypothesized that heterogeneous clots would be prone to poorer recanalization rates and performed a quantitative analysis to test this hypothesis. METHODS: We collected and did histology on clots retrieved by mechanical thrombectomy from 157 stroke cases (107 achieved first-pass effect (FPE) and 50 did not). Using an in-house algorithm, the scanned images were divided into grids (with sizes of 0.2, 0.3, 0.4, 0.5, and 0.6 mm) and the extent of non-uniformity of RBC distribution was computed using the proposed spatial heterogeneity index (SHI). Finally, we validated the clinical significance of clot heterogeneity using the Mann-Whitney test and an artificial neural network (ANN) model. RESULTS: For cases with FPE, SHI values were smaller (0.033 vs 0.039 for grid size of 0.4 mm, P=0.028) compared with those without. In comparison, the clot composition was not statistically different between those two groups. From the ANN model, clot heterogeneity was the most important factor, followed by fibrin content, thrombectomy techniques, red blood cell content, clot area, platelet content, etiology, and admission of intravenous tissue plasminogen activator (IV-tPA). No statistical difference of clot heterogeneity was found for different etiologies, thrombectomy techniques, and IV-tPA administration. CONCLUSIONS: Clot heterogeneity can affect the clot response to thrombectomy devices and is associated with lower FPE. SHI can be a useful metric to quantify clot heterogeneity.
Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Trombose , Humanos , Ativador de Plasminogênio Tecidual , Trombectomia/métodos , Trombose/patologia , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Fibrina/análise , Isquemia Encefálica/complicaçõesRESUMO
BACKGROUND: Several animal studies have demonstrated that mechanical thrombectomy (MT) for acute ischemic stroke (AIS) may cause vessel wall injury (VWI). However, the histological changes in human cerebral arteries following MT are difficult to determine. OBJECTIVE: To investigate the occurrence of VWI during MT by histological and immunohistochemical evaluation of AIS clots. METHODS: As part of the multicenter STRIP registry, 277 clots from 237 patients were analyzed using Martius Scarlett Blue stain and immunohistochemistry for CD34 (endothelial cells) and smooth muscle actin (smooth muscle cells). RESULTS: MT devices used were aspiration catheters (100 cases), stentriever (101 cases), and both (36 cases). VWI was found in 33/277 clots (12%). There was no significant correlation between VWI and MT device. The degree of damage varied from grade I (mild intimal damage, 24 clots), to grade II (relevant intimal and subintimal damage, 3 clots), and III (severe injury, 6 clots). VWI clots contained significantly more erythrocytes (p=0.006*) and less platelets/other (p=0.005*) than non-VWI clots suggesting soft thrombus material.Thrombolysis correlated with a lower rate of VWI (p=0.04*). VWI cases showed a significantly higher number of passes (2 [1-4] vs 1 [1-3], p=0.028*) and poorer recanalization outcome (p=0.01*) than cases without VWI. CONCLUSIONS: Histological markers of VWI were present in 12% of AIS thrombi, suggesting that VWI might be related to MT. VWI was associated with soft thrombus consistency, higher number of passes and poorer revascularization outcome. There was no significant correlation between VWI and MT device.
Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Trombose , Isquemia Encefálica/cirurgia , Células Endoteliais , Humanos , Acidente Vascular Cerebral/cirurgia , Trombectomia/efeitos adversos , Trombose/patologia , Resultado do TratamentoRESUMO
BACKGROUND: Catheter retention and difficulty in retrieval have been observed during embolization of brain arteriovenous malformations (bAVMs) with the Onyx liquid embolic system (Onyx). The Apollo Onyx delivery microcatheter (Apollo) is a single lumen catheter designed for controlled delivery of Onyx into the neurovasculature, with a detachable distal tip to aid catheter retrieval. This study evaluates the safety of the Apollo for delivery of Onyx during embolization of bAVMs. METHODS: This was a prospective, non-randomized, single-arm, multicenter, post-market study of patients with a bAVM who underwent Onyx embolization with the Apollo between May 2015 and February 2018. The primary endpoint was any catheter-related adverse event (AE) at 30 days, such as unintentional tip detachment or malfunction with clinical sequelae, or retained catheter. Procedure-related AEs (untoward medical occurrence, disease, injury, or clinical signs) and serious AEs (life threatening illness or injury, permanent physiological impairment, hospitalization, or requiring intervention) were also recorded. RESULTS: A total of 112 patients were enrolled (mean age 44.1±17.6 years, 56.3% men), and 201 Apollo devices were used in 142 embolization procedures. The mean Spetzler-Martin grade was 2.38. The primary endpoint was not observed (0/112, 0%). The catheter tip detached during 83 (58.5%) procedures, of which 2 (2.4%) were unintentional and did not result in clinical sequelae. At 30 days, procedure related AEs occurred in 26 (23.2%) patients, and procedure-related serious AEs in 12 (10.7%). At 12 months, there were 3 (2.7%) mortalities, including 2 (1.8%) neurological deaths, none of which were device-related. CONCLUSION: This study demonstrates the safety of Apollo for Onyx embolization of bAVMs. CLINICAL TRIAL REGISTRATION: CNCT02378883.
Assuntos
Embolização Terapêutica , Malformações Arteriovenosas Intracranianas , Adulto , Encéfalo , Dimetil Sulfóxido/efeitos adversos , Embolização Terapêutica/efeitos adversos , Feminino , Humanos , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Malformações Arteriovenosas Intracranianas/terapia , Masculino , Pessoa de Meia-Idade , Polivinil/efeitos adversos , Estudos Prospectivos , Resultado do TratamentoRESUMO
BACKGROUND AND AIM: Mechanical thrombectomy (MT) for large vessel occlusion often requires multiple passes to retrieve the entire thrombus load. In this multi-institutional study we sought to examine the composition of thrombus fragments retrieved with each pass during MT. METHODS: Patients who required multiple passes during thrombectomy were included. Histopathological evaluation of thrombus fragments retrieved from each pass was performed using Martius Scarlet Blue staining and the composition of each thrombus component including RBC, fibrin and platelet was determined using image analysis software. RESULTS: 154 patients underwent MT and 868 passes was performed which resulted in 263 thrombus fragments retrieval. The analysis of thrombus components per pass showed higher RBC, lower fibrin and platelet composition in the pass 1 and 2 when compared to pass 3 and passes 4 or more combined (P values <0.05). There were no significant differences between thrombus fragments retrieved in pass 1 and pass 2 in terms of RBC, WBC, fibrin, and platelet composition (P values >0.05). Similarly, when each composition of thrombus fragments retrieved in pass 3 and passes 4 or more combined were compared with each other, no significant difference was noted (P values >0.05). CONCLUSION: Our findings confirm that thrombus fragments retrieved with each pass differed significantly in histological content. Fragments in the first passes were associated with lower fibrin and platelet composition compared to fragments retrieved in passes three and four or higher. Also, thrombus fragments retrieved after failed pass were associated with higher fibrin and platelet components.
Assuntos
Acidente Vascular Cerebral , Trombose , Plaquetas , Fibrina , Humanos , Trombectomia , Trombose/diagnóstico por imagemRESUMO
BACKGROUND: We retrospectively evaluated the composition of retrieved clots from ischemic stroke patients to study the association between histological composition and stroke etiology METHODS: Consecutive patients enrolled in the Stroke Thromboembolism Registry of Imaging and Pathology (STRIP) were included in this study. All patients underwent mechanical thrombectomy and retrieved clots were sent to a central core lab for processing. Histological analysis was performed using martius scarlet blue (MSB) staining, and quantification for red blood cells (RBCs), white blood cells (WBCs), fibrin and platelets was performed using Orbit Image Software. A Wilcoxon test was used for continuous variables and χ2 test for categorical variables. RESULTS: 1350 patients were included in this study. The overall rate of Thrombolysis In Cerebral Infarction (TICI) 2c/3 was 68%. 501 patients received tissue plasminogen activator (tPA) (37%). 267 patients (20%) had a large artery atherosclerosis (LAA) source, 662 (49%) a cardioembolic (CE) source, 301 (22%) were cryptogenic, and the remainder had other identifiable sources including hypercoagulable state or dissection. LAA thrombi had a higher mean RBC density (46±23% vs 42±22%, p=0.01) and a lower platelet density (24±18% vs 27±18%, p=0.03) than CE thrombi. Clots from dissection patients had the highest mean RBC density (50±24%) while clots from patients with a hypercoagulable state had the lowest mean RBC density (26±21%). CONCLUSIONS: Our study found statistically significant but clinically insignificant differences between clots of CE and LAA etiologies. Future studies should emphasize molecular, proteomic and immunohistochemical characteristics to determine links between clot composition and etiology.
Assuntos
Eritrócitos , Sistema de Registros , Acidente Vascular Cerebral/cirurgia , Trombectomia/métodos , Tromboembolia/cirurgia , Trombose/cirurgia , Idoso , Idoso de 80 Anos ou mais , Eritrócitos/química , Feminino , Fibrina/análise , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/sangue , Acidente Vascular Cerebral/diagnóstico por imagem , Tromboembolia/sangue , Tromboembolia/diagnóstico por imagem , Trombose/sangue , Trombose/diagnóstico por imagem , Ativador de Plasminogênio Tecidual/administração & dosagem , Ativador de Plasminogênio Tecidual/análise , Ativador de Plasminogênio Tecidual/sangueRESUMO
BACKGROUND: Current studies on clot characterization in acute ischemic stroke focus on fibrin and red blood cell composition. Few studies have examined platelet composition in acute ischemic stroke clots. We characterize clot composition using the Martius Scarlet Blue stain and assess associations between platelet density and CT density. MATERIALS AND METHOD: Histopathological analysis of the clots collected as part of the multi-institutional STRIP registry was performed using Martius Scarlet Blue stain and the composition of the clots was quantified using Orbit Image Analysis (www.orbit.bio) machine learning software. Prior to endovascular treatment, each patient underwent non-contrast CT (NCCT) and the CT density of each clot was measured. Correlations between clot components and clinical information were assessed using the χ2 test. RESULTS: Eighty-five patients were included in the study. The mean platelet density of the clots was 15.7% (2.5-72.5%). There was a significant correlation between platelet-rich clots and the absence of hyperdensity on NCCT, (ρ=0.321, p=0.003*, n=85). Similarly, there was a significant inverse correlation between the percentage of platelets and the mean Hounsfield Units on NCCT (ρ=-0.243, p=0.025*, n=85). CONCLUSION: Martius Scarlet Blue stain can identify patients who have platelet-rich clots. Platelet-rich clots are isodense on NCCT.
Assuntos
Plaquetas/química , Isquemia Encefálica/diagnóstico por imagem , Coloração e Rotulagem/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Trombose/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Plaquetas/metabolismo , Isquemia Encefálica/sangue , Isquemia Encefálica/patologia , Eritrócitos/química , Feminino , Fibrina/análise , Fibrina/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Acidente Vascular Cerebral/sangue , Acidente Vascular Cerebral/patologia , Trombose/sangue , Trombose/patologia , Adulto JovemRESUMO
INTRODUCTION: The AXERA 2 low-angle vascular access device utilizes a dual arteriotomy mechanism in which the standard access tract is compressed by a vascular sheath inserted over the second, low-angle tract. It is unknown whether this device could be effectively used with 21-gauge micropuncture access, as the micropuncture introducer makes a larger arteriotomy than the 19-gauge needle provided with the AXERA 2 system. MATERIALS AND METHODS: A retrospective review was performed on 189 patients who underwent common femoral artery access for diagnostic cerebrovascular angiography using either combined micropuncture and AXERA 2 access or standard access with manual pressure hemostasis. Demographic and procedural data were reviewed along with complications related to vascular access and times to bed elevation, ambulation and discharge. RESULTS: Combined micropuncture and AXERA 2 access was performed on 110 patients and 79 patients had standard access. The AXERA device was successfully used in 91.8% of the cases. Demographic data, anticoagulant use and sheath sizes were similar between both subsets. Use of the AXERA 2 was associated with two bleeding complications (1.8%) compared with 10 (12.7%) with manual pressure hemostasis alone. Institution-specific protocol allowed shorter mean manual compression time, as well as shorter times to ambulation and discharge with the AXERA 2. CONCLUSIONS: Use of the AXERA 2 device with micropuncture access did not infer increased bleeding risk than standard arterial access in this patient series. The considerable incidence of device use failures suggests a learning curve associated with its use.
Assuntos
Angiografia Cerebral/métodos , Artéria Femoral , Angiografia Cerebral/efeitos adversos , Angiografia Cerebral/instrumentação , Competência Clínica , Desenho de Equipamento , Falha de Equipamento , Artéria Femoral/diagnóstico por imagem , Hemorragia/etiologia , Hemorragia/prevenção & controle , Técnicas Hemostáticas , Humanos , Curva de Aprendizado , Punções , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Dispositivos de Acesso VascularRESUMO
RATIONALE AND OBJECTIVES: To compare a new 7 Fr. Helix thrombectomy catheter with Amplatz thrombectomy devices (ATD) with respect to clot fragmentation efficiency, hemolytic potential, and risk for vascular trauma. MATERIALS AND METHODS: Particle size was evaluated following the maceration of 8-to-10-day-old clots, each weighing 6 +/- 0.01 g. The clots were macerated using devices of various sizes, including the 7-Fr. Helix thrombectomy catheter, the 7-Fr. over-the-wire (OTW), 8-Fr. ATD and the 6-Fr. ATD. The number of particles by weight was quantified. The 7-Fr. Helix and the 8-Fr. ATD were tested in the native iliac vein of six dogs without presence of clots. Blood samples were obtained before, during, and at 1, 3, 6, 24, and 48 hours after the procedure, to monitor the hemolytic effects. The treated iliac veins were examined histologically. RESULTS: Most of the clot was fragmented into particles <10 microm. The mean percentage by weight of the original clot that remained as particles larger than 10 microm was 1.59% in the 7-Fr. Helix group. This was significantly less than 3.10% with the 6-Fr. ATD, 2.57% with 7-Fr. OTW and 2.44% in the 8-Fr. ATD group (<0.01). In vivo results showed a higher plasma free hemoglobin (PFH) level starting 5 minutes after initiating the ATD activation, reaching its peak after completion of the activation, and declining afterward, with return to the baseline at 24 hours. The haptoglobin level tended to decline slightly at 10 minutes, reaching its lowest level at 24 hours, and starting to recover at 48 hours. A similar pattern of PFH and haptoglobin changes was found in both groups. There were no significant differences regarding hemolytic effect of the two tested devices. No significant changes of creatinine were observed for up to 48 hours after procedures. Focal microthrombosis was seen in two sites of two vessels treated with the 7-Fr. Helix and a focal injury of a venous valve was noted in the 8-Fr. ATD group. The media and internal elastic lamina (IEL) were intact in all cases. CONCLUSION: The newly designed 7-Fr. Helix is more effective in fragmentation in vitro clots than the 6 Fr. ATD, 7-Fr. OTW and the 8-Fr. ATD. The 7-Fr. Helix and the 8-Fr. ATD produced hemolytic effects, but they appeared to be tolerated by the animals. The in vivo results indicated that the 7-Fr. Helix appears to be as safe as the 8-Fr. ATD.