Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Bone Joint Res ; 11(7): 494-502, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35818859

RESUMO

AIMS: A functional anterior cruciate ligament (ACL) or posterior cruciate ligament (PCL) has been assumed to be required for patients undergoing unicompartmental knee arthroplasty (UKA). However, this assumption has not been thoroughly tested. Therefore, this study aimed to assess the biomechanical effects exerted by cruciate ligament-deficient knees with medial UKAs regarding different posterior tibial slopes. METHODS: ACL- or PCL-deficient models with posterior tibial slopes of 1°, 3°, 5°, 7°, and 9° were developed and compared to intact models. The kinematics and contact stresses on the tibiofemoral joint were evaluated under gait cycle loading conditions. RESULTS: Anterior translation increased in ACL-deficient UKA cases compared with intact models. In contrast, posterior translation increased in PCL-deficient UKA cases compared with intact models. As the posterior tibial slope increased, anterior translation of ACL-deficient UKA increased significantly in the stance phase, and posterior translation of PCL-deficient UKA increased significantly in the swing phase. Furthermore, as the posterior tibial slope increased, contact stress on the other compartment increased in cruciate ligament-deficient UKAs compared with intact UKAs. CONCLUSION: Fixed-bearing medial UKA is a viable treatment option for patients with cruciate ligament deficiency, providing a less invasive procedure and allowing patient-specific kinematics to adjust posterior tibial slope. Patient selection is important, and while AP kinematics can be compensated for by posterior tibial slope adjustment, rotational stability is a prerequisite for this approach. ACL- or PCL-deficient UKA that adjusts the posterior tibial slope might be an alternative treatment option for a skilled surgeon. Cite this article: Bone Joint Res 2022;11(7):494-502.

2.
Bone Joint Res ; 11(5): 252-259, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35491552

RESUMO

AIMS: This study aimed to identify the effect of anatomical tibial component (ATC) design on load distribution in the periprosthetic tibial bone of Koreans using finite element analysis (FEA). METHODS: 3D finite element models of 30 tibiae in Korean women were created. A symmetric tibial component (STC, NexGen LPS-Flex) and an ATC (Persona) were used in surgical simulation. We compared the FEA measurements (von Mises stress and principal strains) around the stem tip and in the medial half of the proximal tibial bone, as well as the distance from the distal stem tip to the shortest anteromedial cortical bone. Correlations between this distance and FEA measurements were then analyzed. RESULTS: The distance from the distal stem tip to the shortest cortical bone showed no statistically significant difference between implants. However, the peak von Mises stress around the distal stem tip was higher with STC than with ATC. In the medial half of the proximal tibial bone: 1) the mean von Mises stress, maximum principal strain, and minimum principal strain were higher with ATC; 2) ATC showed a positive correlation between the distance and mean von Mises stress; 3) ATC showed a negative correlation between the distance and mean minimum principal strain; and 4) STC showed no correlation between the distance and mean measurements. CONCLUSION: Implant design affects the load distribution on the periprosthetic tibial bone, and ATC can be more advantageous in preventing stress-shielding than STC. However, under certain circumstances with short distances, the advantage of ATC may be offset. Cite this article: Bone Joint Res 2022;11(5):252-259.

3.
Am Heart J ; 160(5): 987-94, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21095290

RESUMO

AIMS: There is a growing concern about the occurrence of coronary artery aneurysms (CAAs) after drug-eluting stent (DES) implantation and their long-term course. We assessed the occurrence and the factors affecting the long-term outcome of DES-associated CAA. METHODS AND RESULTS: We analyzed 3,612 consecutive patients (4,419 lesions) who underwent follow-up angiography after DES implantation. All 34 CAAs (0.76% per lesion) in 29 patients (0.8% per patient) were detected at follow-up, and the mean elapsed time from DES implantation to CAA diagnosis was 414 ± 213 days. Angiographically, CAAs developed almost exclusively in complex (type B2/C) de novo lesions (30 [88.2%] of 34 lesions), and lesion length was significantly greater in patients with CAA than without CAA (26.9 ± 9.03 vs 23.1 ± 7.14 mm; P = .004). Myocardial infarction with stent thrombosis occurred in 5 patients with CAA (17.2%), 4 of whom were on aspirin only without clopidogrel. CONCLUSION: Although CAAs rarely develop after DES implantation and show mostly favorable clinical courses, long-term maintenance of clopidogrel therapy might be required to minimize occurrence of adverse clinical events resulting from stent thrombosis.


Assuntos
Aneurisma Coronário/epidemiologia , Estenose Coronária/cirurgia , Stents Farmacológicos/efeitos adversos , Aneurisma Coronário/diagnóstico , Aneurisma Coronário/etiologia , Angiografia Coronária , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , República da Coreia/epidemiologia , Fatores de Risco , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA