Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Neuroimage ; 209: 116516, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-31904490

RESUMO

The temporal monocular crescent (TMC) is the most peripheral portion of the visual field whose perception relies solely on input from the ipsilateral eye. According to a handful of post-mortem histological studies in humans and non-human primates, the TMC is represented visuotopically within the most anterior portion of the primary visual cortical area (V1). However, functional evidence of the TMC visuotopic representation in human visual cortex is rare, mostly due to the small size of the TMC representation (~6% of V1) and due to the technical challenges of stimulating the most peripheral portion of the visual field inside the MRI scanner. In this study, by taking advantage of custom-built MRI-compatible visual stimulation goggles with curved displays, we successfully stimulated the TMC region of the visual field in eight human subjects, half of them right-eye dominant, inside a 3 â€‹T MRI scanner. This enabled us to localize the representation of TMC, along with the blind spot representation (another visuotopic landmark in V1), in all volunteers, which match the expected spatial pattern based on prior anatomical studies. In all hemispheres, the TMC visuotopic representation was localized along the peripheral border of V1, within the most anterior portion of the calcarine sulcus, without any apparent extension into the second visual area (V2). We further demonstrate the reliability of this localization within/across experimental sessions, and consistency in the spatial location of TMC across individuals after accounting for inter-subject structural differences.


Assuntos
Mapeamento Encefálico/métodos , Imageamento por Ressonância Magnética/métodos , Disco Óptico/fisiologia , Córtex Visual/fisiologia , Campos Visuais/fisiologia , Adulto , Mapeamento Encefálico/instrumentação , Dispositivos de Proteção dos Olhos , Feminino , Humanos , Masculino , Disco Óptico/anatomia & histologia , Disco Óptico/diagnóstico por imagem , Estimulação Luminosa , Córtex Visual/anatomia & histologia , Córtex Visual/diagnóstico por imagem , Adulto Jovem
2.
IEEE Trans Magn ; 54(1)2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29749974

RESUMO

Permanent magnet arrays offer several attributes attractive for the development of a low-cost portable MRI scanner for brain imaging. They offer the potential for a relatively lightweight, low to mid-field system with no cryogenics, a small fringe field, and no electrical power requirements or heat dissipation needs. The cylindrical Halbach array, however, requires external shimming or mechanical adjustments to produce B0 fields with standard MRI homogeneity levels (e.g., 0.1 ppm over FOV), particularly when constrained or truncated geometries are needed, such as a head-only magnet where the magnet length is constrained by the shoulders. For portable scanners using rotation of the magnet for spatial encoding with generalized projections, the spatial pattern of the field is important since it acts as the encoding field. In either a static or rotating magnet, it will be important to be able to optimize the field pattern of cylindrical Halbach arrays in a way that retains construction simplicity. To achieve this, we present a method for designing an optimized cylindrical Halbach magnet using the genetic algorithm to achieve either homogeneity (for standard MRI applications) or a favorable spatial encoding field pattern (for rotational spatial encoding applications). We compare the chosen designs against a standard, fully populated sparse Halbach design, and evaluate optimized spatial encoding fields using point-spread-function and image simulations. We validate the calculations by comparing to the measured field of a constructed magnet. The experimentally implemented design produced fields in good agreement with the predicted fields, and the genetic algorithm was successful in improving the chosen metrics. For the uniform target field, an order of magnitude homogeneity improvement was achieved compared to the un-optimized, fully populated design. For the rotational encoding design the resolution uniformity is improved by 95% compared to a uniformly populated design.

3.
Neuroimage ; 147: 577-588, 2017 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-28011252

RESUMO

Post-operative MRI of patients with deep brain simulation (DBS) implants is useful to assess complications and diagnose comorbidities, however more than one third of medical centers do not perform MRIs on this patient population due to stringent safety restrictions and liability risks. A new system of reconfigurable magnetic resonance imaging head coil composed of a rotatable linearly-polarized birdcage transmitter and a close-fitting 32-channel receive array is presented for low-SAR imaging of patients with DBS implants. The novel system works by generating a region with low electric field magnitude and steering it to coincide with the DBS lead trajectory. We demonstrate that the new coil system substantially reduces the SAR amplification around DBS electrodes compared to commercially available circularly polarized coils in a cohort of 9 patient-derived realistic DBS lead trajectories. We also show that the optimal coil configuration can be reliably identified from the image artifact on B1+ field maps. Our preliminary results suggest that such a system may provide a viable solution for high-resolution imaging of DBS patients in the future. More data is needed to quantify safety limits and recommend imaging protocols before the novel coil system can be used on patients with DBS implants.


Assuntos
Encéfalo/diagnóstico por imagem , Estimulação Encefálica Profunda , Neuroestimuladores Implantáveis , Imageamento por Ressonância Magnética , Simulação por Computador , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas
4.
Magn Reson Med ; 75(1): 441-51, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25689977

RESUMO

PURPOSE: We add user-controllable direct currents (DC) to the individual elements of a 32-channel radio-frequency (RF) receive array to provide B0 shimming ability while preserving the array's reception sensitivity and parallel imaging performance. METHODS: Shim performance using constrained DC current (± 2.5A) is simulated for brain arrays ranging from 8 to 128 elements. A 32-channel 3-tesla brain array is realized using inductive chokes to bridge the tuning capacitors on each RF loop. The RF and B0 shimming performance is assessed in bench and imaging measurements. RESULTS: The addition of DC currents to the 32-channel RF array is achieved with minimal disruption of the RF performance and/or negative side effects such as conductor heating or mechanical torques. The shimming results agree well with simulations and show performance superior to third-order spherical harmonic (SH) shimming. Imaging tests show the ability to reduce the standard frontal lobe susceptibility-induced fields and improve echo planar imaging geometric distortion. The simulation of 64- and 128-channel brain arrays suggest that even further shimming improvement is possible (equivalent to up to 6th-order SH shim coils). CONCLUSION: Including user-controlled shim currents on the loops of a conventional highly parallel brain array coil is feasible with modest current levels and produces improved B0 shimming performance over standard second-order SH shimming.


Assuntos
Encéfalo/anatomia & histologia , Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Transdutores , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Anesth Analg ; 123(1): 82-92, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27140684

RESUMO

BACKGROUND: An unanticipated difficult airway during induction of anesthesia can be a vexing problem. In the setting of can't intubate, can't ventilate (CICV), rapid recovery of spontaneous ventilation is a reasonable goal. The urgency of restoring ventilation is a function of how quickly a patient's hemoglobin oxygen saturation decreases versus how much time is required for the effects of induction drugs to dissipate, namely the duration of unresponsiveness, ventilatory depression, and neuromuscular blockade. It has been suggested that prompt reversal of rocuronium-induced neuromuscular blockade with sugammadex will allow respiratory activity to recover before significant arterial desaturation. Using pharmacologic simulation, we compared the duration of unresponsiveness, ventilatory depression, and neuromuscular blockade in normal, obese, and morbidly obese body sizes in this life-threatening CICV scenario. We hypothesized that although neuromuscular function could be rapidly restored with sugammadex, significant arterial desaturation will occur before the recovery from unresponsiveness and/or central ventilatory depression in obese and morbidly obese body sizes. METHODS: We used published models to simulate the duration of unresponsiveness and ventilatory depression using a common induction technique with predicted rates of oxygen desaturation in various size patients and explored to what degree rapid reversal of rocuronium-induced neuromuscular blockade with sugammadex might improve the return of spontaneous ventilation in CICV situations. RESULTS: Our simulations showed that the duration of neuromuscular blockade was longer with 1.0 mg/kg succinylcholine than with 1.2 mg/kg rocuronium followed 3 minutes later by 16 mg/kg sugammadex (10.0 vs 4.5 minutes). Once rocuronium neuromuscular blockade was completely reversed with sugammadex, the duration of hemoglobin oxygen saturation >90%, loss of responsiveness, and intolerable ventilatory depression (a respiratory rate of ≤4 breaths/min) were dependent on the body habitus and duration of oxygen administration. There is a high probability of intolerable ventilatory depression that extends well beyond the time when oxygen saturation decreases <90%, especially in obese and morbidly obese patients. If ventilatory rescue is inadequate, oxygen desaturation will persist in the latter groups, despite full reversal of neuromuscular blockade. Depending on body habitus, the duration of intolerable ventilatory depression after sugammadex reversal may be as long as 15 minutes in 5% of individuals. CONCLUSIONS: The clinical management of CICV should focus primarily on restoration of airway patency, oxygenation, and ventilation consistent with the American Society of Anesthesiologist's practice guidelines for management of the difficult airway. Pharmacologic intervention cannot be relied upon to rescue patients in a CICV crisis.


Assuntos
Androstanóis/administração & dosagem , Anestesia Geral , Intubação Intratraqueal/efeitos adversos , Pulmão/inervação , Bloqueio Neuromuscular/métodos , Junção Neuromuscular/efeitos dos fármacos , Fármacos Neuromusculares não Despolarizantes/administração & dosagem , Obesidade/complicações , Ventilação Pulmonar/efeitos dos fármacos , Respiração Artificial , Succinilcolina/administração & dosagem , gama-Ciclodextrinas/administração & dosagem , Adulto , Androstanóis/efeitos adversos , Período de Recuperação da Anestesia , Biomarcadores/sangue , Índice de Massa Corporal , Simulação por Computador , Humanos , Masculino , Modelos Teóricos , Fármacos Neuromusculares não Despolarizantes/efeitos adversos , Obesidade/diagnóstico , Obesidade Mórbida/complicações , Obesidade Mórbida/diagnóstico , Oxiemoglobinas/metabolismo , Recuperação de Função Fisiológica , Centro Respiratório/efeitos dos fármacos , Fatores de Risco , Rocurônio , Succinilcolina/efeitos adversos , Sugammadex , Fatores de Tempo , gama-Ciclodextrinas/efeitos adversos
6.
J Am Chem Soc ; 136(4): 1636-42, 2014 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-24400919

RESUMO

Three-dimensional printing with high-temperature plastic is used to enable spin exchange optical pumping (SEOP) and hyperpolarization of xenon-129 gas. The use of 3D printed structures increases the simplicity of integration of the following key components with a variable temperature SEOP probe: (i) in situ NMR circuit operating at 84 kHz (Larmor frequencies of (129)Xe and (1)H nuclear spins), (ii) <0.3 nm narrowed 200 W laser source, (iii) in situ high-resolution near-IR spectroscopy, (iv) thermoelectric temperature control, (v) retroreflection optics, and (vi) optomechanical alignment system. The rapid prototyping endowed by 3D printing dramatically reduces production time and expenses while allowing reproducibility and integration of "off-the-shelf" components and enables the concept of printing on demand. The utility of this SEOP setup is demonstrated here to obtain near-unity (129)Xe polarization values in a 0.5 L optical pumping cell, including ∼74 ± 7% at 1000 Torr xenon partial pressure, a record value at such high Xe density. Values for the (129)Xe polarization exponential build-up rate [(3.63 ± 0.15) × 10(-2) min(-1)] and in-cell (129)Xe spin-lattice relaxation time (T1 = 2.19 ± 0.06 h) for 1000 Torr Xe were in excellent agreement with the ratio of the gas-phase polarizations for (129)Xe and Rb (PRb ∼ 96%). Hyperpolarization-enhanced (129)Xe gas imaging was demonstrated with a spherical phantom following automated gas transfer from the polarizer. Taken together, these results support the development of a wide range of chemical, biochemical, material science, and biomedical applications.


Assuntos
Imageamento Tridimensional/instrumentação , Espectroscopia de Ressonância Magnética/instrumentação , Desenho de Equipamento , Temperatura , Isótopos de Xenônio
7.
Sci Rep ; 5: 15177, 2015 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-26469756

RESUMO

Magnetic Resonance Imaging (MRI) is unparalleled in its ability to visualize anatomical structure and function non-invasively with high spatial and temporal resolution. Yet to overcome the low sensitivity inherent in inductive detection of weakly polarized nuclear spins, the vast majority of clinical MRI scanners employ superconducting magnets producing very high magnetic fields. Commonly found at 1.5-3 tesla (T), these powerful magnets are massive and have very strict infrastructure demands that preclude operation in many environments. MRI scanners are costly to purchase, site, and maintain, with the purchase price approaching $1 M per tesla (T) of magnetic field. We present here a remarkably simple, non-cryogenic approach to high-performance human MRI at ultra-low magnetic field, whereby modern under-sampling strategies are combined with fully-refocused dynamic spin control using steady-state free precession techniques. At 6.5 mT (more than 450 times lower than clinical MRI scanners) we demonstrate (2.5 × 3.5 × 8.5) mm(3) imaging resolution in the living human brain using a simple, open-geometry electromagnet, with 3D image acquisition over the entire brain in 6 minutes. We contend that these practical ultra-low magnetic field implementations of MRI (<10 mT) will complement traditional MRI, providing clinically relevant images and setting new standards for affordable (<$50,000) and robust portable devices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA