Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Q J Nucl Med Mol Imaging ; 62(4): 420-428, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29869485

RESUMO

BACKGROUND: In patients with advanced stage cancer of the uterine cervix who undergo irradiation with curative intent, there is the necessity to treat all suspicious nodes on imaging. Our hypothesis was that adding fluorodeoxyglucose positron emission computer tomography/computer tomography (FDG-PET/CT) to the imaging workup would alter the external beam radiotherapy (EBRT) treatment plan, either resulting in an extended external beam radiotherapy (EBRT) field to the para-aortal region or an additional boost to suspicious nodes. Since extended field radiotherapy or additional boost can cause toxicity, our secondary aim was to assess the incidence of severe late bowel toxicity in patients treated with extended para-aortal EBRT-field and boost compared to elective pelvic radiotherapy. METHODS: Eighty-eight patients were enrolled. First, the optimal radiation treatment plan (EBRT and boost) was retrospectively determined based on magnetic resonance imaging (MRI) or FDG-PET/CT. Second, the severe bowel toxicity caused by the extended para-aortal field was assessed, based on the executed radiotherapy. RESULTS: Based on MRI 8/88 patients would receive EBRT with para-aortic extension, this was 21/88 for FDG-PET/CT. Based on MRI 47/704 lymph node regions would receive additional boost, while based on PET/CT 91/704. Late severe bowel toxicity was seen in 12/84 patients, 6/65 in the group who received elective pelvic irradiation and 6/19 with para-aortal EBRT and boost at common iliac and/or para-aortal lymph nodes. Significant worse overall survival was seen of patients who needed para-aortal irradiation. CONCLUSIONS: Addition of FDG-PET/CT leads to an extension of the elective EBRT volume and more suspicious lymph nodes receive a boost. However, when deciding to intensify radiation therapy, late severe bowel toxicity has to be taken into account.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Radioterapia Guiada por Imagem , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Metástase Linfática , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Retrospectivos , Análise de Sobrevida , Neoplasias do Colo do Útero/patologia , Neoplasias do Colo do Útero/cirurgia
2.
Curr Oncol ; 30(4): 4275-4288, 2023 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-37185439

RESUMO

(1) Background: Over the past two decades use of new imaging modalities and the adaptation of applicators have allowed for advances in volumetric (3D) imaging-based brachytherapy practices for patients with locally advanced cervical cancer. The aim of this study was to compare the oncological outcome and toxicity for three consecutively introduced brachytherapy practices in a large single-center cohort; (2) Methods: Patients treated for cervical cancer with primary radiotherapy and curative intent were consecutively included in this retrospective, single-center cohort study from 2006 to 2019. This cohort was divided into three groups (CT, MRI, and MRI+needles) based on the timing of the introduction of a novel brachytherapy practice; 3D brachytherapy planning using CT- and MRI-guided adaptive brachytherapy and the use of parametrial interstitial needles, respectively. Actuarial estimates were compared between groups. Multivariable Cox regression analyses were performed to correct for other risk factors. Crude rates of severe (≥grade 3) late toxicity were reported; (3) Results: A total of 397 patients were included in this cohort. At a median follow-up of 40 months (interquartile range (IQR) 22-62), actuarial 3-year local control, pelvic control, disease-free survival, and overall survival for the entire cohort were 91% (95% (Confidence Interval (CI)) 88-94), 88% (95% CI 84-91), 69% (95% CI 64-74), and 75% (95% CI 70-79), respectively). Local control, disease-free survival, and overall survival were significantly improved in the MRI+needles group compared to the CT group (p = 0.040, p = 0.004, and p < 0.001, respectively). Independent risk factors for overall survival were treatment in either the CT or MRI group (vs. MRI+needles), older age at diagnosis, adeno (squamous) carcinoma, FIGO stage III/IV, and lymph node metastases. The crude rate of severe late toxicity was 27% in the CT, 26% in the MRI, and 20% in the MRI+needles group; (4) Conclusions: Prognosis in women with locally advanced cervical cancer treated with state-of-the-art MRI-guided adaptive brachytherapy combined with parametrial interstitial needles compares favorably to patients treated with more traditional CT only based brachytherapy.


Assuntos
Braquiterapia , Neoplasias do Colo do Útero , Humanos , Feminino , Neoplasias do Colo do Útero/radioterapia , Neoplasias do Colo do Útero/patologia , Estudos Retrospectivos , Estudos de Coortes , Prognóstico
3.
Med Phys ; 48(6): 3109-3119, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33738805

RESUMO

PURPOSE: Magnetic resonance imaging (MRI) is increasingly used in radiation oncology for target delineation and radiotherapy treatment planning, for example, in patients with gynecological cancers. As a consequence of pelvic radiotherapy, a part of the bowel is irradiated, yielding risk of bowel toxicity. Existing dose-effect models predicting bowel toxicity are inconclusive and bowel motion might be an important confounding factor. The exact motion of the bowel and dosimetric effects of its motion are yet uncharted territories in radiotherapy. In diagnostic radiology methods on the acquisition of dynamic MRI sequences were developed for bowel motility visualization and quantification. Our study aim was to develop an imaging technique based on three-dimensional (3D) cine-MRI to visualize and quantify bowel motion and demonstrate it in a cohort of gynecological cancer patients. METHODS: We developed an MRI acquisition suitable for 3D bowel motion quantification, namely a balanced turbo field echo sequence (TE = 1.39 ms, TR = 2.8 ms), acquiring images in 3.7 s (dynamic) with a 1.25 × 1.25 × 2.5 mm3 resolution, yielding a field of view of 200 × 200 × 125 mm3 . These MRI bowel motion sequences were acquired in 22 gynecological patients. During a 10-min scan, 160 dynamics were acquired. Subsequent dynamics were deformably registered using a B-spline transformation model, resulting in 159 3D deformation vector fields (DVFs) per MRI set. From the 159 DVFs, the average vector length was calculated per voxel to generate bowel motion maps. Quality assurance was performed on all 159 DVFs per MRI, using the Jacobian Determinant and the Harmonic Energy as deformable image registration error metrics. In order to quantify bowel motion, we introduced the concept of cumulative motion-volume histogram (MVH) of the bowel bag volume. Finally, interpatient variation of bowel motion was analyzed using the MVH parameters M10%, M50%, and M90%. The M10%/M50%/M90% represents the minimum bowel motion per frame of 10%/50%/90% of the bowel bag volume. RESULTS: The motion maps resulted in a visualization of areas with small and large movements within the bowel bag. After applying quality assurance, the M10%, M50%, and M90% were 4.4 (range 2.2-7.6) mm, 2.2 (range 0.9-4.1) mm, and 0.5 (range 0.2-1.4) mm per frame, on average over all patients, respectively. CONCLUSION: We have developed a method to visualize and quantify 3D bowel motion with the use of bowel motion specific MRI sequences in 22 gynecological cancer patients. This 3D cine-MRI-based quantification tool and the concept of MVHs can be used in further studies to determine the effect of radiotherapy on bowel motion and to find the relation with dose effects to the small bowel. In addition, the developed technique can be a very interesting application for bowel motility assessment in diagnostic radiology.


Assuntos
Neoplasias , Respiração , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética
4.
Ned Tijdschr Geneeskd ; 159: A9237, 2015.
Artigo em Holandês | MEDLINE | ID: mdl-26507064

RESUMO

A 29-year-old man presented with a painless soft mass that was hanging on a string of skin on his upper leg. Physical examination revealed a 5 cm broad, elastic, stalked skin toned mass. On microscopic examination the diagnosis fibrolipoma was objectified.


Assuntos
Lipoma/diagnóstico , Neoplasias de Tecidos Moles/diagnóstico , Adulto , Diagnóstico Diferencial , Humanos , Perna (Membro)/patologia , Lipoma/patologia , Lipoma/cirurgia , Masculino , Neoplasias de Tecidos Moles/patologia , Neoplasias de Tecidos Moles/cirurgia , Tela Subcutânea/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA