Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Sensors (Basel) ; 18(2)2018 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-29462870

RESUMO

Polydiacetylene (PDA) inserted in films or in vesicles has received increasing attention due to its property to undergo a blue-to-red colorimetric transition along with a change from non-fluorescent to fluorescent upon application of various stimuli. In this review paper, the principle for the detection of various microorganisms (bacteria, directly detected or detected through the emitted toxins or through their DNA, and viruses) and of antibacterial and antiviral peptides based on these responsive PDA vesicles are detailed. The analytical performances obtained, when vesicles are in suspension or immobilized, are given and compared to those of the responsive vesicles mainly based on the vesicle encapsulation method. Many future challenges are then discussed.


Assuntos
Técnicas Biossensoriais , Colorimetria , Polímero Poliacetilênico , Polímeros , Poli-Inos
2.
Sensors (Basel) ; 17(8)2017 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-28813013

RESUMO

Electrospinning has emerged as a very powerful method combining efficiency, versatility and low cost to elaborate scalable ordered and complex nanofibrous assemblies from a rich variety of polymers. Electrospun nanofibers have demonstrated high potential for a wide spectrum of applications, including drug delivery, tissue engineering, energy conversion and storage, or physical and chemical sensors. The number of works related to biosensing devices integrating electrospun nanofibers has also increased substantially over the last decade. This review provides an overview of the current research activities and new trends in the field. Retaining the bioreceptor functionality is one of the main challenges associated with the production of nanofiber-based biosensing interfaces. The bioreceptors can be immobilized using various strategies, depending on the physical and chemical characteristics of both bioreceptors and nanofiber scaffolds, and on their interfacial interactions. The production of nanobiocomposites constituted by carbon, metal oxide or polymer electrospun nanofibers integrating bioreceptors and conductive nanomaterials (e.g., carbon nanotubes, metal nanoparticles) has been one of the major trends in the last few years. The use of electrospun nanofibers in ELISA-type bioassays, lab-on-a-chip and paper-based point-of-care devices is also highly promising. After a short and general description of electrospinning process, the different strategies to produce electrospun nanofiber biosensing interfaces are discussed.


Assuntos
Nanofibras , Sistemas de Liberação de Medicamentos , Nanotubos de Carbono , Polímeros , Engenharia Tecidual
4.
Anal Bioanal Chem ; 406(4): 1039-48, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23907681

RESUMO

A new conductometric enzyme-based biosensor was developed for the determination of formaldehyde (FA) in aqueous solutions. The biosensor was prepared by cross-linking formaldehyde dehydrogenase from Pseudomonas putida with bovine serum albumin in saturated glutaraldehyde vapours (GA) at the surface of interdigitated gold microelectrodes. Nicotinamide adenine dinucleotide cofactor (NAD(+)) was added in solution at each measurement to maintain enzyme activity. Addition of a Nafion layer over the enzyme modified electrode resulted in a significant increase of biosensor signal due to enhanced accumulation of protons generated by enzymatic reaction at the electrode surface. Different parameters affecting enzyme activity or playing a role in ionic transfer through the Nafion membrane were optimised. In optimal conditions (0.045 mg enzyme, 30 min exposure to GA, 0.3 µL of a 1% (v/v) Nafion solution deposit, measurement in 5 mM phosphate buffer pH 7 containing 20 µM NAD(+)), the biosensor signal was linear up to 10 mM FA, and the detection limit was 18 µM. Relative standard deviations calculated from five consecutive replicates of FA solutions were lower than 5% in the 1-10 mM range. The biosensor was successfully applied to the determination of FA in spiked water samples (tap water and Rhone river water), with recoveries in the 95-110% range.


Assuntos
Aldeído Oxirredutases/química , Proteínas de Bactérias/química , Técnicas Biossensoriais/métodos , Condutometria/métodos , Formaldeído/análise , Pseudomonas putida/enzimologia , Poluentes Químicos da Água/análise , Técnicas Biossensoriais/instrumentação , Condutometria/instrumentação , Eletrodos , Enzimas Imobilizadas/química , Polímeros de Fluorcarboneto/química , Limite de Detecção , Pseudomonas putida/química
5.
ACS Appl Mater Interfaces ; 16(23): 29645-29656, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38809175

RESUMO

The cell-SELEX method enables efficient selection of aptamers that bind whole bacterial cells. However, after selection, it is difficult to determine their binding affinities using common screening methods because of the large size of the bacteria. Here we propose a simple surface plasmon resonance imaging method (SPRi) for aptamer characterization using bacterial membrane vesicles, called nanosomes, instead of whole cells. Nanosomes were obtained from membrane fragments after mechanical cell disruption in order to preserve the external surface epitopes of the bacterium used for their production. The study was conducted on Bacillus cereus (B. cereus), a Gram-positive bacterium commonly found in soil, rice, vegetables, and dairy products. Four aptamers and one negative control were initially grafted onto a biochip. The binding of B. cereus cells and nanosomes to immobilized aptamers was then compared. The use of nanosomes instead of cells provided a 30-fold amplification of the SPRi signal, thus allowing the selection of aptamers with higher affinities. Aptamer SP15 was found to be the most sensitive and selective for B. cereus ATCC14579 nanosomes. It was then truncated into three new sequences (SP15M, SP15S1, and SP15S2) to reduce its size while preserving the binding site. Fitting the results of the SPRi signal for B. cereus nanosomes showed a similar trend for SP15 and SP15M, and a slightly higher apparent association rate constant kon for SP15S2, which is the truncation with a high probability of a G-quadruplex structure. These observations were confirmed on nanosomes from B. cereus ATCC14579 grown in milk and from the clinical strain B. cereus J066. The developed method was validated using fluorescence microscopy on whole B. cereus cells and the SP15M aptamer labeled with a rhodamine. This study showed that nanosomes can successfully mimic the bacterial membrane with great potential for facilitating the screening of specific ligands for bacteria.


Assuntos
Aptâmeros de Nucleotídeos , Bacillus cereus , Ressonância de Plasmônio de Superfície , Ressonância de Plasmônio de Superfície/métodos , Aptâmeros de Nucleotídeos/química , Aptâmeros de Nucleotídeos/metabolismo , Bacillus cereus/metabolismo , Bacillus cereus/química , Técnica de Seleção de Aptâmeros
6.
Micromachines (Basel) ; 14(7)2023 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-37512723

RESUMO

The rapid and sensitive detection of food contaminants is becoming increasingly important for timely prevention and treatment of foodborne disease. In this review, we discuss recent developments of electrochemical biosensors as facile, rapid, sensitive, and user-friendly analytical devices and their applications in food safety analysis, owing to the analytical characteristics of electrochemical detection and to advances in the design and production of bioreceptors (antibodies, DNA, aptamers, peptides, molecular imprinted polymers, enzymes, bacteriophages, etc.). They can offer a low limit of detection required for food contaminants such as allergens, pesticides, antibiotic traces, toxins, bacteria, etc. We provide an overview of a broad range of electrochemical biosensing designs and consider future opportunities for this technology in food control.

7.
J Bacteriol ; 193(15): 3785-93, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21665978

RESUMO

Nickel and cobalt are both essential trace elements that are toxic when present in excess. The main resistance mechanism that bacteria use to overcome this toxicity is the efflux of these cations out of the cytoplasm. RND (resistance-nodulation-cell division)- and MFS (major facilitator superfamily)-type efflux systems are known to export either nickel or cobalt. The RcnA efflux pump, which belongs to a unique family, is responsible for the detoxification of Ni and Co in Escherichia coli. In this work, the role of the gene yohN, which is located downstream of rcnA, is investigated. yohN is cotranscribed with rcnA, and its expression is induced by Ni and Co. Surprisingly, in contrast to the effect of deleting rcnA, deletion of yohN conferred enhanced resistance to Ni and Co in E. coli, accompanied by decreased metal accumulation. We show that YohN is localized to the periplasm and does not bind Ni or Co ions directly. Physiological and genetic experiments demonstrate that YohN is not involved in Ni import. YohN is conserved among proteobacteria and belongs to a new family of proteins; consequently, yohN has been renamed rcnB. We show that the enhanced resistance of rcnB mutants to Ni and Co and their decreased Ni and Co intracellular accumulation are linked to the greater efflux of these ions in the absence of rcnB. Taken together, these results suggest that RcnB is required to maintain metal ion homeostasis, in conjunction with the efflux pump RcnA, presumably by modulating RcnA-mediated export of Ni and Co to avoid excess efflux of Ni and Co ions via an unknown novel mechanism.


Assuntos
Proteínas de Transporte de Cátions/metabolismo , Cobalto/metabolismo , Proteínas de Escherichia coli/metabolismo , Escherichia coli/metabolismo , Níquel/metabolismo , Proteínas Periplásmicas/metabolismo , Transporte Biológico , Proteínas de Transporte de Cátions/genética , Proteínas de Transporte de Cobre , Escherichia coli/genética , Proteínas de Escherichia coli/genética , Proteínas Periplásmicas/genética
8.
Anal Bioanal Chem ; 400(4): 947-64, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21424523

RESUMO

During recent decades, extensive industrialisation and farming associated with improper waste management policies have led to the release of a wide range of toxic compounds into aquatic ecosystems, causing a rapid decrease of world freshwater resources and thus requiring urgent implementation of suitable legislation to define water remediation and protection strategies. In Europe, the Water Framework Directive aims to restore good qualitative and quantitative status to all water bodies by 2015. To achieve that, extensive monitoring programmes will be required, calling for rapid, reliable and cost-effective analytical methods for monitoring and toxicological impact assessment of water pollutants. In this context, whole cell biosensors appear as excellent alternatives to or techniques complementary to conventional chemical methods. Cells are easy to cultivate and manipulate, host many enzymes able to catalyse a wide range of biological reactions and can be coupled to various types of transducers. In addition, they are able to provide information about the bioavailability and the toxicity of the pollutants towards eukaryotic or prokaryotic cells. In this article, we present an overview of the use of whole cells, mainly bacteria, yeasts and algae, as sensing elements in electrochemical biosensors with respect to their practical applications in water quality monitoring, with particular emphasis on new trends and future perspectives. In contrast to optical detection, electrochemical transduction is not sensitive to light, can be used for analysis of turbid samples and does not require labelling. In some cases, it is also possible to achieve higher selectivities, even without cell modification, by operating at specific potentials where interferences are limited.


Assuntos
Técnicas Biossensoriais/métodos , Células/metabolismo , Poluentes da Água/análise , Bactérias/metabolismo , Técnicas Eletroquímicas , Poluentes da Água/toxicidade , Abastecimento de Água/normas
9.
Anal Bioanal Chem ; 400(4): 1083-92, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21052645

RESUMO

Trichloroethylene (TCE), a suspected human carcinogen, is one of the most common volatile groundwater contaminants. Many different methodologies have already been developed for the determination of TCE and its degradation products in water, but most of them are costly, time-consuming and require well-trained operators. In this work, a fast, sensitive and miniaturised whole cell conductometric biosensor was developed for the determination of trichloroethylene. The biosensor assembly was prepared by immobilising Pseudomonas putida F1 bacteria (PpF1) at the surface of gold interdigitated microelectrodes through a three-dimensional alkanethiol self-assembly monolayer/carbon nanotube architecture functionalised with Pseudomonas antibodies. The biosensor response was linear from 0.07 to 100 µM of TCE (9-13,100 µg L(-1)). No significant loss of the enzymatic activity was observed after 5 weeks of storage at 4 °C in the M457 pH 7 defined medium (two or three measurements per week). Ninety-two per cent of the initial signal still remained after 7 weeks. The biosensor response to TCE was not significantly affected by cis-1,2-dichloroethylene and vinyl chloride and, in a limited way, by phenol. Toluene was the major interference found. The bacterial biosensor was successfully applied to the determination of TCE in spiked groundwater samples and in six water samples collected in an urban industrial site contaminated with TCE. Gas chromatography-mass spectrometric analysis of these samples confirmed the biosensor measurements.


Assuntos
Bactérias/metabolismo , Técnicas Biossensoriais/métodos , Nanotubos de Carbono , Tricloroetileno/análise , Anticorpos Antibacterianos , Técnicas Biossensoriais/instrumentação , Células Imobilizadas/enzimologia , Resíduos Industriais/análise , Resíduos Industriais/prevenção & controle , Pseudomonas putida/enzimologia , Poluentes Químicos da Água/análise
10.
Nanotechnology ; 21(39): 395103, 2010 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-20820094

RESUMO

The unique magnetic properties of iron oxide nanoparticles have paved the way for various biomedical applications, such as magnetic resonance cellular imaging or magnetically induced therapeutic hyperthermia. Living cells interact with nanoparticles by internalizing them within intracellular acidic compartments. Although no acute toxicity of iron oxide nanoparticles has been reported up to now, the mechanisms of nanoparticle degradation by the cellular environment are still unknown. In the organism, the long term integrity and physical state of iron-based nanoparticles are challenged by iron homeostasis. In this study, we monitored the degradation of 7 nm sized maghemite nanoparticles in a medium mimicking the intracellular environment. Magnetic nanoparticles with three distinct surface coatings, currently evaluated as MRI contrast agents, were shown to exhibit different kinetics of dissolution at an acidic pH in the presence of a citrate chelating agent. Our assessment of the physical state of the nanoparticles during degradation revealed that the magnetic properties, size distribution and structure of the remaining nanocrystals were identical to those of the initial suspension. This result suggests a model for nanoparticle degradation with rapidly dissolved nanocrystals and a reservoir of intact nanoparticles.


Assuntos
Meios de Contraste/metabolismo , Lisossomos/metabolismo , Nanopartículas de Magnetita/ultraestrutura , Modelos Biológicos , Modelos Químicos , Citratos , Meios de Contraste/química , Compostos Férricos , Concentração de Íons de Hidrogênio , Lisossomos/química , Imageamento por Ressonância Magnética , Nanopartículas de Magnetita/química , Tamanho da Partícula , Citrato de Sódio , Propriedades de Superfície , Temperatura , Fatores de Tempo
11.
Front Chem ; 8: 678, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32850678

RESUMO

In this work, polyacrylonitrile (PAN) nanofiber mats coated with conductive polypyrrole layers were produced at the surface of gold electrodes by a two-step approach combining electrospinning and vapor phase polymerization. In the first step, smooth and uniform PAN fibers exhibiting an average diameter of 650 ± 10 nm were generated through electrospinning of 12 wt% PAN solutions. The electrospun PAN fibers were impregnated with iron(III)tosylate (FeTos), annealed at 70°C and used as a robust and stable template for the growth of a thin layer of conductive polymer by co-polymerizing pyrrole (Py) and pyrrole-3-carboyxylic acid (Py3COOH) vapors under nitrogen atmosphere. The carboxyl groups introduced in polypyrrole coatings enabled further covalent binding of a model enzyme, glucose oxidase. The effect of different parameters (concentration of FeTos into the immersion solution, time of polymerization, Py/Py3COOH molar ratio) on the PAN/PPy/PPy3COOH/GOx impedimetric biosensor response was investigated. In the best conditions tested (immersion of the PAN fibers into 20 wt% FeTos solution, polymerization time: 30 min, 1:2 Py/Py3COOH ratio), the biosensor response was linear in a wide range of glucose concentration (20 nM-2µM) and selective toward ascorbic and uric acids. A very low limit of detection (2 nM) compared to those already reported in the literature was achieved. This value enables the determination of glucose in human serum after a large dilution of the sample (normal concentrations: 3.6 mM-6.1 mM range).

12.
J Agric Food Chem ; 54(20): 7450-9, 2006 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-17002407

RESUMO

An analytical method has been developed for the quantification of two herbicides (ethidimuron and methabenzthiazuron) and their two main soil derivatives. This method involves fluidized-bed extraction (FBE) prior to cleanup and analysis by reverse-phase liquid chromatography with UV detection at 282 nm. FBE conditions were established to provide efficient extraction without degradation of the four analytes. (14)C-labeled compounds were used for the optimization of extraction and purification steps and for the determination of related efficiencies. Extraction was optimal using a fexIKA extractor operating at 110 degrees C for three cycles (total time = 95 min) with 75 g of soil and 150 mL of a 60:40 v/v acetone/water mixture. Extracts were further purified on a 500 mg silica SPE cartridge. Separation was performed on a C18 Purosphere column (250 mm x 4 mm i.d.), at 0.8 mL min(-1) and 30 degrees C with an elution gradient made up of phosphoric acid aqueous solution (pH 2.2) and acetonitrile. Calibration curves were found to be linear in the 0.5-50 mg L(-1) concentration range. Besides freshly spiked soil samples, method validation included the analysis of samples with aged residues. Recovery values, determined from spiked samples, were close to 100%. Limits of detection ranged between 2 and 3 microg kg(-1) of dry soil and limits of quantification between 8 and 10 microg kg(-1) of dry soil. An attempt to improve these performances by using fluorescence detection following postcolumn derivatization by orthophthalaldehyde-mercaptoethanol reagent was unsuccessful.


Assuntos
Benzotiazóis/análise , Herbicidas/análise , Compostos de Metilureia/análise , Solo/análise , Benzotiazóis/química , Cromatografia Líquida de Alta Pressão/métodos , Compostos de Metilureia/química , Fotólise , Sensibilidade e Especificidade , Soluções
13.
ACS Appl Mater Interfaces ; 8(2): 1424-33, 2016 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-26710829

RESUMO

Improving graphene-based electrode fabrication processes and developing robust methods for its functionalization are two key research routes to develop new high-performance electrodes for electrochemical applications. Here, a self-organized three-dimensional (3D) graphene electrode processed by pulsed laser deposition with thermal annealing is reported. This substrate shows great performance in electron transfer kinetics regarding ferrocene redox probes in solution. A robust electrografting strategy for covalently attaching a redox probe onto these graphene electrodes is also reported. The modification protocol consists of a combination of diazonium salt electrografting and click chemistry. An alkyne-terminated phenyl ring is first electrografted onto the self-organized 3D graphene electrode by in situ electrochemical reduction of 4-ethynylphenyl diazonium. Then the ethynylphenyl-modified surface efficiently reacts with the redox probe bearing a terminal azide moiety (2-azidoethyl ferrocene) by means of Cu(I)-catalyzed alkyne-azide cycloaddition. Our modification strategy applied to 3D graphene electrodes was analyzed by means of atomic force microscopy, scanning electron microscopy, Raman spectroscopy, cyclic voltammetry, and X-ray photoelectron spectroscopy (XPS). For XPS chemical surface analysis, special attention was paid to the distribution and chemical state of iron and nitrogen in order to highlight the functionalization of the graphene-based substrate by electrochemically grafting a ferrocene derivative. Dense grafting was observed, offering 4.9 × 10(-10) mol cm(-2) surface coverage and showing a stable signal over 22 days. The electrografting was performed in the form of multilayers, which offers higher ferrocene loading than a dense monolayer on a flat surface. This work opens highly promising perspectives for the development of self-organized 3D graphene electrodes with various sensing functionalities.

14.
Nanoscale Res Lett ; 10: 149, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25873843

RESUMO

The application of silicalite for improvement of working characteristics of conductometric enzyme biosensors for determination of sucrose was studied in this research. Biosensors based on different types of silicalite-modified electrodes were studied and compared according to their analytical characteristics. Polyethylenimine/glutaraldehyde/silicalite-modified biosensors showed higher sensitivity compared with others type of biosensors. Moreover, the polyethylenimine/glutaraldehyde/silicalite sucrose biosensors were characterized by high selectivity and signal reproducibility (relative standard deviation (RSD) = 2.78% for glucose measurements and RSD = 3.2% for sucrose measurements). Proposed biosensors were used for determination of sucrose in different samples of beverages. The obtained results had good correlation with results obtained by HPLC. Thus, polyethylenimine/glutaraldehyde/silicalite-modified biosensors have shown perspective characteristics for the development of effective conductometric enzyme biosensors.

15.
Nanoscale Res Lett ; 10: 209, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25991913

RESUMO

In this work, the method of enzyme adsorption on different zeolites and mesoporous silica spheres (MSS) was investigated for the creation of conductometric biosensors. The conductometric transducers consisted of gold interdigitated electrodes were placed on the ceramic support. The transducers were modified with zeolites and MSS, and then the enzymes were adsorbed on the transducer surface. Different methods of zeolite attachment to the transducer surface were used; drop coating with heating to 200°C turned out to be the best one. Nanozeolites beta and L, zeolite L, MSS, and silicalite-1 (80 to 450 nm) were tested as the adsorbents for enzyme urease. The biosensors with all tested particles except zeolite L had good analytical characteristics. Silicalite-1 (450 nm) was also used for adsorption of glucose oxidase, acetylcholinesterase, and butyrylcholinesterase. The glucose and acetylcholine biosensors were successfully created, whereas butyrylcholinesterase was not adsorbed on silicalite-1. The enzyme adsorption on zeolites and MSS is simple, quick, well reproducible, does not require use of toxic compounds, and therefore can be recommended for the development of biosensors when these advantages are especially important.

16.
Food Chem ; 184: 1-6, 2015 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-25872419

RESUMO

We report a dose-dependent detection of androstenone in solution, as one of the boar taint compounds, based on related OR7D4 olfactory receptors immobilized on a gold electrode through their 6-His tag and NTA-copper complex, as visualized through fluorescence microscopy. Square wave voltammetry (SWV) is for the first time, the method used to monitor the olfactory receptor/odorant recognition process. The relative variation of the Cu(I)-Cu(II) current peak increases linearly versus log (concentration of androstenone) from 10(-14)M to 10(-4)M, in buffer solution. Negative tests were performed, using an unrelated odorant, helional, itself a ligand of OR 1740. Cross-selectivity was also tested after immobilization of OR 1740.


Assuntos
Androstenos/análise , Técnicas Eletroquímicas , Histidina/química , Proteínas Imobilizadas/química , Receptores Odorantes/química , Animais , Ouro , Masculino , Microscopia de Fluorescência , Suínos
17.
Nanoscale Res Lett ; 10: 59, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25852356

RESUMO

A number of potentiometric biosensors based on coimmobilization of enzymes with different types of zeolite on pH-ion-sensitive field-effect transistor (ISFET) have been developed. Their working characteristics have been determined and compared. It was shown that clinoptilolite and zeolite Beta polymorph A (BEA) are more promising for creating biosensors than zeolite A. Changing the concentration of zeolite BEA in membranes, it is possible to extend the biosensor linear measurement range. The two-layer method of deposition of the enzyme with clinoptilolite was found to provide a significant increase in the biosensor sensitivity to substrates, whereas thermal modification of the zeolite BEA crystals can improve analytical characteristics of potentiometric biosensors for detection of toxic substances. These results show that it is possible to regulate the ISFET characteristics for different enzyme-based biosensors by tailoring the electrode surfaces via different zeolites. This makes zeolites strong candidates for integration into biosensors as ISFET modifiers.

18.
FEMS Microbiol Lett ; 237(2): 249-53, 2004 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-15321669

RESUMO

An efficient, inexpensive microplate colorimetric assay for screening of bacteria which can be used in bioremediation of arsenic was developed. The assay is based on the colorimetric analysis of the precipitates formed upon reaction of silver nitrate with arsenic. The method proved reliable and sensitive for the detection of As[III] oxidizers and As[V] reducers and can be used over a large pH range (5.8-8.4). Seventy-eight bacterial strains isolated from different environments were tested by this method. It also showed agreement with results obtained by high-performance liquid chromatography coupled with inductively coupled plasma atomic emission spectrometry.


Assuntos
Arseniatos/metabolismo , Arsenitos/metabolismo , Bactérias/metabolismo , Técnicas Bacteriológicas , Colorimetria/métodos , Arsênio/metabolismo , Biodegradação Ambiental , Soluções Tampão , Oxirredução , Nitrato de Prata/química
19.
Bioelectrochemistry ; 90: 24-9, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23174485

RESUMO

This study is based on the conductometric measurement of alkaline phosphatase activity (APA) from the cyanobacterium, Arthrospira platensis, called Spirulina. Cyanobacterium cells were directly immobilized, by physical adsorption, on the ceramic part of gold interdigitated transducers. This activity was inhibited in the presence of heavy metals and a variation of the local conductivity was measured after addition of the substrate. The Michaelis-Menten constant (Km) was evaluated to be 0.75 mM through a calibration curve of the substrate, disodium 4-nitrophenylphosphate p-nitrophenyl phosphate (pNPP). Inhibition of APA was observed with cadmium and mercury with a detection limit of 10(-20) M. The half maximal inhibitory concentration (IC50) was determined at 10(-19) M for Cd(2+) and 10(-17) M for Hg(2+), and the binding affinity of heavy metal (Ki) was equal to the IC50. On the sensor surface, scanning electron microscopy (SEM) images revealed a remarkable evolution of the cyanobacterium's external surface that was attributable to the first defense mechanism against toxic heavy metals in trace. This effect was also confirmed through the important increase of response time τ(90%) recorded for APA response towards the substrate pNPP after cell exposure to metallic cations. Lifetime of the Spirulina-based biosensor was estimated to be more than 25 days.


Assuntos
Fosfatase Alcalina/metabolismo , Técnicas Biossensoriais/métodos , Cádmio/análise , Condutometria/métodos , Mercúrio/análise , Spirulina/enzimologia , Células Imobilizadas/enzimologia , Limite de Detecção
20.
Environ Pollut ; 178: 182-8, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23583674

RESUMO

Enzymatic conductometric biosensor, using immobilized Arthrospira platensis cells on gold interdigitated electrodes, for the detection of pesticides in water, was elaborated. Cholinesterase activity (AChE) was inhibited by pesticides and a variation of the local conductivity was measured after addition of the substrate acetylthiocholine chloride (AChCl). The Michaelis-Menten constant (Km) was evaluated to be 1.8 mM through a calibration curve of AChCl. Inhibition of AChE was observed with paraoxon-methyl, parathion-methyl, triazine and diuron with a detection limit of 10(-18) M, 10(-20) M, 10(-20) M and 10(-12) M, respectively and the half maximal inhibitory concentration (IC50) was determined at 10(-16) M, 10(-20) M, 10(-18) M and 10(-06) M, respectively. An important decrease of response time τ90% was recorded for AChE response towards AChCl after 30 min cell exposure to pesticides. Scanning electron microscopy images revealed a degradation of the cell surface in presence of pesticides at 10(-06) M.


Assuntos
Acetilcolinesterase/metabolismo , Inibidores da Colinesterase/análise , Condutometria/métodos , Cianobactérias/efeitos dos fármacos , Praguicidas/análise , Inibidores da Colinesterase/toxicidade , Cianobactérias/metabolismo , Monitoramento Ambiental/métodos , Limite de Detecção , Praguicidas/toxicidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA