Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Nano Lett ; 16(9): 5373-7, 2016 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-27490749

RESUMO

According to the American skin cancer foundation, there are more new cases of skin cancer than the combined incidence of cancers of the breast, prostate, lung, and colon each year, and malignant melanoma represents its deadliest form. About 50% of all cases are characterized by a particular mutation BRAF(V600E) in the BRAF (Rapid Acceleration of Fibrosarcoma gene B) gene. Recently developed highly specific drugs are able to fight BRAF(V600E) mutated tumors but require diagnostic tools for fast and reliable mutation detection to warrant treatment efficiency. We completed a preliminary clinical trial applying cantilever array sensors to demonstrate identification of a BRAF(V600E) single-point mutation using total RNA obtained from biopsies of metastatic melanoma of diverse sources (surgical material either frozen or fixated with formalin and embedded in paraffin). The method is faster than the standard Sanger or pyrosequencing methods and comparably sensitive as next-generation sequencing. Processing time from biopsy to diagnosis is below 1 day and does not require PCR amplification, sequencing, and labels.


Assuntos
Análise Mutacional de DNA , Melanoma/genética , Proteínas Proto-Oncogênicas B-raf/genética , Neoplasias Cutâneas/genética , Biópsia , Humanos , Mutação
2.
Sensors (Basel) ; 16(7)2016 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-27455276

RESUMO

For many diseases, where a particular organ is affected, chemical by-products can be found in the patient's exhaled breath. Breath analysis is often done using gas chromatography and mass spectrometry, but interpretation of results is difficult and time-consuming. We performed characterization of patients' exhaled breath samples by an electronic nose technique based on an array of nanomechanical membrane sensors. Each membrane is coated with a different thin polymer layer. By pumping the exhaled breath into a measurement chamber, volatile organic compounds present in patients' breath diffuse into the polymer layers and deform the membranes by changes in surface stress. The bending of the membranes is measured piezoresistively and the signals are converted into voltages. The sensor deflection pattern allows one to characterize the condition of the patient. In a clinical pilot study, we investigated breath samples from head and neck cancer patients and healthy control persons. Evaluation using principal component analysis (PCA) allowed a clear distinction between the two groups. As head and neck cancer can be completely removed by surgery, the breath of cured patients was investigated after surgery again and the results were similar to those of the healthy control group, indicating that surgery was successful.


Assuntos
Técnicas Biossensoriais/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Testes Respiratórios , Feminino , Neoplasias de Cabeça e Pescoço/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Análise de Componente Principal
3.
Anal Chem ; 85(18): 8676-83, 2013 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-23905589

RESUMO

A microcantilever based method for fluid viscosity and mass density measurements with high temporal resolution and microliter sample consumption is presented. Nanomechanical cantilever vibration is driven by photothermal excitation and detected by an optical beam deflection system using two laser beams of different wavelengths. The theoretical framework relating cantilever response to the viscosity and mass density of the surrounding fluid was extended to consider higher flexural modes vibrating at high Reynolds numbers. The performance of the developed sensor and extended theory was validated over a viscosity range of 1-20 mPa·s and a corresponding mass density range of 998-1176 kg/m(3) using reference fluids. Separating sample plugs from the carrier fluid by a two-phase configuration in combination with a microfluidic flow cell, allowed samples of 5 µL to be sequentially measured under continuous flow, opening the method to fast and reliable screening applications. To demonstrate the study of dynamic processes, the viscosity and mass density changes occurring during the free radical polymerization of acrylamide were monitored and compared to published data. Shear-thinning was observed in the viscosity data at higher flexural modes, which vibrate at elevated frequencies. Rheokinetic models allowed the monomer-to-polymer conversion to be tracked in spite of the shear-thinning behavior, and could be applied to study the kinetics of unknown processes.


Assuntos
Sistemas Computacionais , Glicerol/análise , Técnicas Analíticas Microfluídicas/métodos , Nanopartículas/química , Vibração , Glicerol/química , Viscosidade
4.
Sensors (Basel) ; 13(4): 5273-85, 2013 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-23604028

RESUMO

A cantilever-based protein biosensor has been developed providing a customizable multilayer platform for the detection of antibodies. It consists of a biotin-terminated PEG layer pre-functionalized on the gold-coated cantilever surface, onto which NeutrAvidin is adsorbed through biotin/NeutrAvidin specific binding. NeutrAvidin is used as a bridge layer between the biotin-coated surface and the biotinylated biomolecules, such as biotinylated bovine serum albumin (biotinylated BSA), forming a multilayer sensor for direct antibody capture. The cantilever biosensor has been successfully applied to the detection of mouse anti-BSA (m-IgG) and sheep anti-BSA(s-IgG) antibodies. As expected, the average differential surface stress signals of about 5.7 ± 0.8 × 10(-3) N/m are very similar for BSA/m-IgG and BSA/s-IgG binding, i.e., they are independent of the origin of the antibody. A statistic evaluation of 112 response curves confirms that the multilayer protein cantilever biosensor shows high reproducibility. As a control test, a biotinylated maltose binding protein was used for detecting specificity of IgG, the result shows a signal of bBSA layer in response to antibody is 5.8 × 10(-3) N/m compared to bMBP. The pre-functionalized biotin/PEG cantilever surface is found to show a long shelf-life of at least 40 days and retains its responsivity of above 70% of the signal when stored in PBS buffer at 4 °C. The protein cantilever biosensor represents a rapid, label-free, sensitive and reliable detection technique for a real-time protein assay.


Assuntos
Anticorpos/análise , Avidina/metabolismo , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/normas , Biotina/metabolismo , Animais , Antígenos/metabolismo , Biotinilação , Bovinos , Imunoglobulina G/análise , Camundongos , Padrões de Referência , Reprodutibilidade dos Testes , Soroalbumina Bovina/metabolismo
5.
Langmuir ; 28(15): 6494-501, 2012 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-22439593

RESUMO

The accessibility and binding affinity of DNA are two key parameters affecting the hybridization efficiency in surface-based biosensor technologies. Better accessibility will result in a higher hybridization efficiency. Often, mixed ssDNA and mercaptohexanol monolayers are used to increase the hybridization efficiency and accessibility of surface-bound oligonucleotides to complementary target DNA. Here, no mercaptohexanol monolayer was used. We demonstrate by differential microcantilever deflection measurements at different pH that the hybridization efficiency peaks between pH 7.5 and 8.5. At low pH 4.5, hydration and electrostatic forces led to tensile surface stress, implying the reduced accessibility of the bound ssDNA probe for hybridization. In contrast, at high pH 8.5, the steric interaction between neighboring ssDNA strands was decreased by higher electrostatic repulsive forces, bending the microcantilever away from the gold surface to provide more space for the target DNA. Cantilever deflection scales with pH-dependent surface hybridization efficiency because of high target DNA accessibility. Hence, by changing the pH, the hybridization efficiency is adjusted.


Assuntos
DNA/química , Fenômenos Mecânicos , Nanotecnologia/métodos , Hibridização de Ácido Nucleico/métodos , Sequência de Bases , DNA/genética , DNA de Cadeia Simples/química , DNA de Cadeia Simples/genética , Concentração de Íons de Hidrogênio , Modelos Moleculares , Conformação de Ácido Nucleico , Propriedades de Superfície
6.
Biosensors (Basel) ; 12(11)2022 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-36354504

RESUMO

Sepsis is a life-threatening condition mostly caused by a bacterial infection resulting in inflammatory reaction and organ dysfunction if not treated effectively. Rapid identification of the causing bacterial pathogen already in the early stage of bacteremia is therefore vital. Current technologies still rely on time-consuming procedures including bacterial culturing up to 72 h. Our approach is based on ultra-rapid and highly sensitive nanomechanical sensor arrays. In measurements we observe two clearly distinguishable distributions consisting of samples with bacteria and without bacteria respectively. Compressive surface stress indicates the presence of bacteria. For this proof-of-concept, we extracted total RNA from EDTA whole blood samples from patients with blood-culture-confirmed bacteremia, which is the reference standard in diagnostics. We determined the presence or absence of bacterial RNA in the sample through 16S-rRNA hybridization and species-specific probes using nanomechanical sensor arrays. Via both probes, we identified two clinically highly-relevant bacterial species i.e., Escherichia coli and Staphylococcus aureus down to an equivalent of 20 CFU per milliliter EDTA whole blood. The dynamic range of three orders of magnitude covers most clinical cases. We correctly identified all patient samples regarding the presence or absence of bacteria. We envision our technology as an important contribution to early and sensitive sepsis diagnosis directly from blood without requirement for cultivation. This would be a game changer in diagnostics, as no commercial PCR or POCT device currently exists who can do this.


Assuntos
Bacteriemia , Sepse , Humanos , Ácido Edético , RNA Ribossômico 16S/análise , RNA Ribossômico 16S/genética , Bactérias/genética , Bacteriemia/diagnóstico , Bacteriemia/microbiologia , Sepse/diagnóstico , Escherichia coli/genética
7.
Glob Chall ; 5(2): 2000066, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33552553

RESUMO

The worldwide emergence of multidrug-resistant (MDR) bacteria is associated with significant morbidity, mortality, and healthcare costs. Rapid and accurate diagnostic methods to detect antibiotic resistance are critical for antibiotic stewardship and infection control measurements. Here a cantilever nanosensor-based diagnostic assay is shown to detect single nucleotide polymorphisms (SNPs) and genes associated with antibiotic resistance in Gram negative (Pseudomonas aeruginosa) and positive (Enterococcus faecium) bacteria, representing frequent causes for MDR infections. Highly specific RNA capture probes for SNPs (ampRD135G or ampRG154R ) or resistance genes (vanA, vanB, and vanD) allow to detect the binding of bacterial RNA within less than 5 min. Serial dilutions of bacterial RNA indicate an unprecedented sensitivity of 10 fg µL-1 total RNA corresponding to less than ten bacterial cells for SNPs and 1 fg µL-1 total RNA for vanD detection equivalent to single bacterial cell sensitivity.

8.
Nanotechnology ; 20(1): 015501, 2009 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-19417252

RESUMO

The performance of microfabricated piezoresistive cantilever array sensors has been evaluated using various vapors of volatile organic compounds including alkanes with different chain length from 5 (n-pentane) to 14 (n-tetradecane). We demonstrate that piezoresistive microcantilever array sensors have the selectivity of discriminating individual alkanes in a homologous series as well as common volatile organic compounds according to principal component analysis. We developed a new method to evaluate the sensitivity, taking advantage of the low vapor pressures of alkanes with longer chains, such as n-dodecane, n-tridecane and n-tetradecane, under saturated vapor conditions. This method reveals sub-ppm sensitivity and the cantilever response is found to follow the mass of evaporated analytes as calculated using a quantitative model based on the Langmuir evaporation model.

9.
Top Curr Chem ; 285: 1-27, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-23636674

RESUMO

Microfabricated cantilevers have been used in atomic force microscopy for the topography imagingof non-conductive surfaces for more than 20 years. Cantilever beams without tips have proved theirapplicability in recent years as miniaturized, ultrasensitive, and fast-responding sensors for applicationsin chemistry, physics, biochemistry, and medicine. Microcantilever sensors respond by bending dueto the absorption of molecules. A shift in resonance frequency also occurs. They can be operatedin different environments such as gaseous environment, liquids, or vacuum. In gas, microcantileversensors can be operated as an artificial nose, whereby the bending pattern of a microfabricatedarray of eight polymer-coated silicon cantilevers is characteristic of the different vapors from solvents,flavors, and beverages. When operated in a liquid, microcantilever sensors are able to detectbiochemical reactions. Each cantilever is functionalized with a specific biochemical probe receptor,sensitive for detection of the corresponding target molecule. Applications lie in the fields of label-and amplification-free detection of DNA hybridization, the detection of proteins as well as antigen-antibodyreactions, and the detection of larger entities, such as bacteria and fungi.

10.
Biosens Bioelectron ; 21(8): 1599-605, 2006 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-16137876

RESUMO

We report the measurement of protein interaction with double-stranded DNA oligonucleotides using cantilever microarray technology. We investigated two different DNA-binding proteins, the transcription factors SP1 and NF-kappaB, using cantilever arrays as they allow label-free measurement of different biomolecular interactions in parallel. Double-stranded DNA oligonucleotides containing a specific binding site for a transcription factor were sensitized on gold-coated cantilevers. The binding of the transcription factor creates a surface stress, resulting in a bending of the cantilevers. Both transcription factors could be detected independently at concentrations of 80-100 nM. A concentration dependence of the bending signal was measured using concentrations from 100 to 400 nM of NF-kappaB. The experiments show that the recognition sequence of one transcription factor can serve as a reference for the other, highlighting the sequence specificity of transcription factor binding.


Assuntos
Proteínas de Ligação a DNA/análise , DNA/análise , Análise Serial de Proteínas/instrumentação , Refratometria/instrumentação , Fatores de Transcrição/análise , DNA/química , Proteínas de Ligação a DNA/química , Desenho de Equipamento , Análise de Falha de Equipamento , Análise Serial de Proteínas/métodos , Refratometria/métodos , Coloração e Rotulagem , Fatores de Transcrição/química
11.
Biosens Bioelectron ; 21(6): 849-56, 2005 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-16257652

RESUMO

We demonstrate the use of micromechanical cantilever arrays for selective immobilization and fast quantitative detection of vital fungal spores. Micro-fabricated uncoated as well as gold-coated silicon cantilevers were functionalized with concanavalin A, fibronectin or immunoglobulin G. In our experiments two major morphological fungal forms were used--the mycelial form Aspergillus niger and the unicellular yeast form Saccharomyces cerevisiae, as models to explore a new method for growth detection of eukaryotic organisms using cantilever arrays. We exploited the specific biomolecular interactions of surface grafted proteins with the molecular structures on the fungal cell surface. It was found that these proteins have different affinities and efficiencies to bind the spores. Maximum spore immobilization, germination and mycelium growth was observed on the immunoglobulin G functionalized cantilever surfaces. We show that spore immobilization and germination of the mycelial fungus A. niger and yeast S. cerevisiae led to shifts in resonance frequency within a few hours as measured by dynamically operated cantilever arrays, whereas conventional techniques would require several days. The biosensor could detect the target fungi in a range of 10(3) - 10(6) CFUml(-1). The measured shift is proportional to the mass of single fungal spores and can be used to evaluate spore contamination levels. Applications lie in the field of medical and agricultural diagnostics, food- and water-quality monitoring.


Assuntos
Aspergillus niger/crescimento & desenvolvimento , Aspergillus niger/isolamento & purificação , Técnicas Biossensoriais/instrumentação , Contagem de Colônia Microbiana/instrumentação , Eletroquímica/instrumentação , Saccharomyces cerevisiae/crescimento & desenvolvimento , Saccharomyces cerevisiae/isolamento & purificação , Aderência Bacteriana/fisiologia , Técnicas Biossensoriais/métodos , Técnicas de Cultura de Células/métodos , Proliferação de Células , Contagem de Colônia Microbiana/métodos , Sistemas Computacionais , Eletroquímica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Mecânica , Miniaturização , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Esporos Fúngicos/crescimento & desenvolvimento , Esporos Fúngicos/isolamento & purificação , Transdutores
12.
Phys Rev E Stat Nonlin Soft Matter Phys ; 72(3 Pt 1): 031907, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16241482

RESUMO

Micromechanical cantilever arrays are used to measure time-resolved adsorption of tiny masses based on protein-ligand interactions. Here, streptavidin-biotin interactions are investigated in a physiological environment. A measurement method is introduced using higher flexural modes of a silicon cantilever in order to enhance the sensitivity of mass detection. Modeling the cantilever vibration in liquid allows the measurement of absolute mass changes. We show time-resolved mass adsorption of final 7+/-0.7 ng biotinylated latex beads. The sensitivity obtained is about 2.5 pg/Hz measuring at a center frequency of 750 kHz.


Assuntos
Fenômenos Biomecânicos/instrumentação , Biopolímeros/análise , Técnicas Biossensoriais/instrumentação , Desenho Assistido por Computador , Imunoensaio/instrumentação , Mapeamento de Interação de Proteínas/instrumentação , Transdutores , Fenômenos Biomecânicos/métodos , Técnicas Biossensoriais/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Imunoensaio/métodos , Peso Molecular , Mapeamento de Interação de Proteínas/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Vibração
13.
Swiss Med Wkly ; 145: w14092, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25664868

RESUMO

Cancer is a major burden in today's society and one of the leading causes of death in industrialised countries. Various avenues for the detection of cancer exist, most of which rely on standard methods, such as histology, ELISA, and PCR. Here we put the focus on nanomechanical biosensors derived from atomic force microscopy cantilevers. The versatility of this novel technology has been demonstrated in different applications and in some ways surpasses current technologies, such as microarray, quartz crystal microbalance and surface plasmon resonance. The technology enables label free biomarker detection without the necessity of target amplification in a total cellular background, such as BRAF mutation analysis in malignant melanoma. A unique application of the cantilever array format is the analysis of conformational dynamics of membrane proteins associated to surface stress changes. Another development is characterisation of exhaled breath which allows assessment of a patient's condition in a non-invasive manner.


Assuntos
Técnicas Biossensoriais/métodos , Detecção Precoce de Câncer/métodos , Nanotecnologia/métodos , Biomarcadores Tumorais/análise , Humanos , Microscopia de Força Atômica
14.
Beilstein J Nanotechnol ; 1: 3-13, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21977390

RESUMO

Polymers are often used to modify surface properties to control interfacial processes. Their sensitivity to solvent conditions and ability to undergo conformational transitions makes polymers attractive in tailoring surface properties with specific functionalities leading to applications in diverse areas ranging from tribology to colloidal stability and medicine. A key example is polyethylene glycol (PEG), which is widely used as a protein-resistant coating given its low toxicity and biocompatibility. We report here a microcantilever-based sensor for the in situ characterization of PEG monolayer formation on Au using the "grafting to" approach. Moreover, we demonstrate how microcantilevers can be used to monitor conformational changes in the grafted PEG layer in different solvent conditions. This is supported by atomic force microscope (AFM) images and force-distance curve measurements of the microcantilever chip surface, which show that the grafted PEG undergoes a reversible collapse when switching between good and poor solvent conditions, respectively.

15.
Nat Nanotechnol ; 4(3): 179-85, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19265848

RESUMO

Membrane proteins are central to many biological processes, and the interactions between transmembrane protein receptors and their ligands are of fundamental importance in medical research. However, measuring and characterizing these interactions is challenging. Here we report that sensors based on arrays of resonating microcantilevers can measure such interactions under physiological conditions. A protein receptor--the FhuA receptor of Escherichia coli--is crystallized in liposomes, and the proteoliposomes then immobilized on the chemically activated gold-coated surface of the sensor by ink-jet spotting in a humid environment, thus keeping the receptors functional. Quantitative mass-binding measurements of the bacterial virus T5 at subpicomolar concentrations are performed. These experiments demonstrate the potential of resonating microcantilevers for the specific, label-free and time-resolved detection of membrane protein-ligand interactions in a micro-array format.


Assuntos
Técnicas Biossensoriais/instrumentação , Proteínas de Membrana/metabolismo , Proteínas da Membrana Bacteriana Externa/metabolismo , Bacteriófagos , Proteínas de Escherichia coli/metabolismo , Ligantes , Ligação Proteica , Estabilidade Proteica , Proteolipídeos/metabolismo , Receptores de Superfície Celular/metabolismo , Fatores de Tempo
16.
Rev Sci Instrum ; 79(8): 086110, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19044391

RESUMO

A new microcantilever array design is investigated comprising eight flexible microcantilevers introducing two solid bars, enabling to subtract contributions from differences in refractive index in an optical laser read out system. Changes in the refractive index do not contribute undesirably to bending signals at picomolar to micromolar DNA or protein concentrations. However, measurements of samples with high salt concentrations or serum are affected, requiring corrections for refractive index artifacts. Moreover, to obtain a deeper understanding of molecular stress formation, the differential curvature of cantilevers is analyzed by positioning the laser spots along the surface of the levers during pH experiments.


Assuntos
Refratometria/instrumentação , Animais , Artefatos , Soluções Tampão , Bovinos , Desenho de Equipamento , Ouro/química , Concentração de Íons de Hidrogênio , Lasers , Microscopia Eletrônica de Varredura , Nanotecnologia , Ácido Palmítico/química , Fosfatos/química , Padrões de Referência , Soroalbumina Bovina/química , Cloreto de Sódio/química , Especificidade por Substrato , Compostos de Sulfidrila/química , Titânio/química
17.
PLoS One ; 3(11): e3610, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18978938

RESUMO

Molecular interaction is a key concept in our understanding of the biological mechanisms of life. Two physical properties change when one molecular partner binds to another. Firstly, the masses combine and secondly, the structure of at least one binding partner is altered, mechanically transducing the binding into subsequent biological reactions. Here we present a nanomechanical micro-array technique for bio-medical research, which not only monitors the binding of effector molecules to their target but also the subsequent effect on a biological system in vitro. This label-free and real-time method directly and simultaneously tracks mass and nanomechanical changes at the sensor interface using micro-cantilever technology. To prove the concept we measured lipid vesicle (approximately 748*10(6) Da) adsorption on the sensor interface followed by subsequent binding of the bee venom peptide melittin (2840 Da) to the vesicles. The results show the high dynamic range of the instrument and that measuring the mass and structural changes simultaneously allow a comprehensive discussion of molecular interactions.


Assuntos
Bicamadas Lipídicas/metabolismo , Meliteno/metabolismo , Nanotecnologia/métodos , Adsorção , Fenômenos Biomecânicos/fisiologia , Biofísica/instrumentação , Biofísica/métodos , Lipossomos/metabolismo , Meliteno/fisiologia , Fluidez de Membrana/fisiologia , Modelos Biológicos , Nanotecnologia/instrumentação , Ligação Proteica , Propriedades de Superfície
18.
Nanotechnology ; 19(38): 384007, 2008 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-21832567

RESUMO

We present an approach for sensing protein aggregation using microcantilever systems. Results from both single cantilever experiments with internal reference and multicantilever array measurements with dedicated reference cantilevers are discussed. We show that in both cases protein aggregation on the sensor can be detected through associated changes in surface stress.

19.
Microsc Microanal ; 13(1): 13-7, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17234032

RESUMO

We demonstrate a new sensitive biosensor for detection of vital fungal spores of Aspergillus niger. The biosensor is based on silicon microfabricated cantilever arrays operated in dynamic mode. The change in resonance frequency of the sensor is a function of mass binding to the cantilever surface. For specific A. niger spore immobilization on the cantilever, each cantilever was individually coated with anti-Aspergillus niger polyclonal antibodies. We demonstrate the detection of single A. niger spores and their subsequent growth on the functionalized cantilever surface by online measurements of resonance frequency shifts. The new biosensor operating in humid air allows quantitative and qualitative detection of A. niger spores as well as detection of vital, functional spores in situ within approximately 4 h. The detection limit of the sensor is 103 CFU mL-1. Mass sensitivity of the cantilever sensor is approximately 53 pg Hz-1.


Assuntos
Anticorpos Antifúngicos/química , Aspergillus niger/crescimento & desenvolvimento , Esporos Fúngicos/crescimento & desenvolvimento , Anticorpos Antifúngicos/imunologia , Aspergillus niger/imunologia , Aspergillus niger/isolamento & purificação , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Imunoglobulina G/química , Imunoglobulina G/imunologia , Reprodutibilidade dos Testes , Esporos Fúngicos/imunologia , Esporos Fúngicos/isolamento & purificação
20.
J Am Chem Soc ; 129(3): 601-9, 2007 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-17227023

RESUMO

Free-standing cantilevers, which directly translate specific biochemical reactions into micromechanical motion, have recently attracted much attention as label-free biosensors and micro/nano robotic devices. To exploit this mechanochemical sensing technology, it is essential to develop a fundamental understanding of the origins of surface stress. Here we report a detailed study into the molecular basis of stress generation in aqueous environments focusing on the pH titration of model mercaptohexadecanoic acid self-assembled monolayers (SAMs), using in situ reference cantilevers coated with nonionizable hexadecanethiol SAMs. Semiautomated data analysis and a statistical model were developed to quantify cyclic deprotonation/protonation reactions on multiple arrays. In-plane force titrations were found to have the sensitivity to detect ionic hydrogen bond formation between protonated and nonprotonated carboxylic acid groups in the proximity of the surface pK1/2, which generated a mean tensile differential surface stress of +1.2 +/- 0.3 mN/m at pH 6.0, corresponding to 1 pN attractive force between two adjacent MHA molecules. Conversely, the magnitude of compressive differential surface stress was found to increase progressively with pH >/= 7.0, reaching a maximum of -14.5 +/- 0.5 mN/m at pH 9.0, attributed to enhanced electrostatic repulsion between deprotonated carboxylic acid groups. However, striking differences were observed in the micromechanical responses to different ionic strength and ion species present in the aqueous environment, highlighting the critical role of counter- and co-ions on surface stress. Our findings provide fundamental insights into the molecular mechanisms of in-plane mechanochemistry, which may be exploited for biosensing and nanoactuation applications.


Assuntos
Técnicas Biossensoriais/métodos , Ácidos Palmíticos/química , Prótons , Ligação de Hidrogênio , Concentração de Íons de Hidrogênio , Concentração Osmolar , Sensibilidade e Especificidade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA