Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 604(7907): 697-707, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35255491

RESUMO

There is strong evidence of brain-related abnormalities in COVID-191-13. However, it remains unknown whether the impact of SARS-CoV-2 infection can be detected in milder cases, and whether this can reveal possible mechanisms contributing to brain pathology. Here we investigated brain changes in 785 participants of UK Biobank (aged 51-81 years) who were imaged twice using magnetic resonance imaging, including 401 cases who tested positive for infection with SARS-CoV-2 between their two scans-with 141 days on average separating their diagnosis and the second scan-as well as 384 controls. The availability of pre-infection imaging data reduces the likelihood of pre-existing risk factors being misinterpreted as disease effects. We identified significant longitudinal effects when comparing the two groups, including (1) a greater reduction in grey matter thickness and tissue contrast in the orbitofrontal cortex and parahippocampal gyrus; (2) greater changes in markers of tissue damage in regions that are functionally connected to the primary olfactory cortex; and (3) a greater reduction in global brain size in the SARS-CoV-2 cases. The participants who were infected with SARS-CoV-2 also showed on average a greater cognitive decline between the two time points. Importantly, these imaging and cognitive longitudinal effects were still observed after excluding the 15 patients who had been hospitalised. These mainly limbic brain imaging results may be the in vivo hallmarks of a degenerative spread of the disease through olfactory pathways, of neuroinflammatory events, or of the loss of sensory input due to anosmia. Whether this deleterious effect can be partially reversed, or whether these effects will persist in the long term, remains to be investigated with additional follow-up.


Assuntos
Encéfalo , COVID-19 , Idoso , Idoso de 80 Anos ou mais , Bancos de Espécimes Biológicos , Encéfalo/diagnóstico por imagem , Encéfalo/virologia , COVID-19/patologia , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , SARS-CoV-2 , Olfato , Reino Unido/epidemiologia
2.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38262617

RESUMO

AIMS: Systolic blood pressure (SBP) drops recorded by 24-h ambulatory blood pressure (BP) monitoring (ABPM) identify patients with susceptibility to reflex syncope and orthostatic intolerance. We tested the hypothesis that treatments aimed to increase BP (reassurance, education, and lifestyle measures plus pharmacological strategies) can reduce SBP drops. METHODS AND RESULTS: This was a multicentre, observational proof-of-concept study performed in patients with reflex syncope and/or orthostatic intolerance and with SBP drops on a screening ABPM. Among 144 eligible patients, 111 underwent a second ABPM on average 2.5 months after start of treatment. Overall, mean 24-h SBP increased from 114.1 ± 12.1 to 121.4 ± 14.5 mmHg (P < 0.0001). The number of SBP drops <90 and <100 mmHg decreased by 61%, 46% during daytime, and by 48% and 37% during 24-h period, respectively (P < 0.0001 for all). The dose-response relationship between difference in 24-h average SBP increase and reduction in number of SBP drops reached a plateau around ∼15 mmHg increase of 24-h SBP. The reduction in SBP drop rate was consistent and significant in patients who underwent deprescription of hypotensive medications (n = 44) and in patients who received BP-rising drugs (n = 67). CONCLUSION: In patients with reflex syncope and/or orthostatic intolerance, an increase in average 24-h SBP, regardless of the implemented strategy, significantly reduced the number of SBP drops and symptom burden. A 13 mmHg increase in 24-h SBP appears to represent the optimal goal for aborting the maximal number of SBP drops, representing a possible target for future interventions. ClincalTrials.gov identifier: NCT05729724.


Assuntos
Hipertensão , Hipotensão , Intolerância Ortostática , Síncope Vasovagal , Humanos , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea , Monitorização Ambulatorial da Pressão Arterial , Hipertensão/tratamento farmacológico , Intolerância Ortostática/diagnóstico , Intolerância Ortostática/tratamento farmacológico , Reflexo , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/prevenção & controle , Estudo de Prova de Conceito
3.
Europace ; 25(2): 762-766, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36351661

RESUMO

AIMS: We describe a novel, practical, and inexpensive method to add video recording during tilt table testing (TTT): Open-Access-Video-TTT. METHODS AND RESULTS: The Open-Access-Video-TTT set-up uses a personal computer (PC) to capture screen video data from a non-invasive-beat-to-beat (NIBTB) haemodynamic blood pressure (BP) device, combined with video recording of a patient, using Open Broadcaster Software (OBS®). The new Open-Access-Video-TTT set up was tested with both the Finometer (model Finapres Nova®, Medical Systems, the Netherlands) and the Task Force® Touch Cardio monitor (CNSystems, Austria). For this, the Finapres Nova® was enabled in 'remote' mode and Real Video Network Computing (RealVNC®) was installed on the PC/laptop. The Task Force® has a DisplayPort (DP) port, for which a DP/ high-definition multimedia interface (HDMI) cable and a video capture card is used to merge the signals to the PC/laptop. With this method the combined images are stored as a new video signal. TTT can be performed with any routine protocol. CONCLUSIONS: Open Access-Video-TTT worked well for both the Finapres NOVA® and the Task Force Monitor ®. This novel method can be used easily by all physicians who wish to add video recording during TTT who do not have access to an electroencephalogram machine.


Assuntos
Hemodinâmica , Teste da Mesa Inclinada , Humanos , Coração , Software , Áustria
4.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38190741

RESUMO

AIMS: We aimed to identify all syncope units (SUs) in the Netherlands and assess the extent to which these SUs fulfil the essential requirements outlined by the consensus statements of the European Heart Rhythm Association and the European Society of Cardiology syncope guidelines. For this, we developed the SU-19 score, a novel guideline based validation tool for best practice. METHODS AND RESULTS: All outpatient clinics of cardiology, neurology, and internal medicine in the Netherlands were screened for presence of any form of structured specialized syncope care. If present, these were included as SUs and requested to complete a questionnaire regarding syncope care. We assessed all SUs using the SU-19 score regarding structure (3 points), available tests (12 points), and initial evaluation (4 points). Twenty SUs were identified in the Netherlands, both academic (5/20) and non-academic hospitals (15/20), 17/20 reported multidisciplinary involvement during initial evaluation. In 19/20, neurology, cardiology, or both were responsible for the syncope management. Non-physicians were involved performing the head-up tilt test (44%) and initial evaluation (40%). The mean SU-19 score was 18.0 ± 1.1, 45% achieved the maximum score of 19 points. Variations were observed in protocols for active standing test, carotid sinus massage, and head-up tilt test. CONCLUSION: There is a network of 20 SUs in the Netherlands. Forty-five per cent fully met the SU-19 score (mean 18.0 ± 1.1). Slight variety existed in protocols for autonomic function tests. Neurology and cardiology were mostly involved in syncope management. Non-physicians play an important role in syncope care.


Assuntos
Cardiologia , Síncope , Humanos , Países Baixos/epidemiologia , Estudos Transversais , Síncope/diagnóstico , Síncope/terapia , Teste da Mesa Inclinada
5.
Europace ; 25(8)2023 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-37622579

RESUMO

Over the last 25 years, the Europace journal has greatly contributed to dissemination of research and knowledge in the field of syncope. More than 400 manuscripts have been published in the journal. They undoubtedly improved our understanding of syncope. This symptom is now clearly differentiated from other forms of transient loss of consciousness. The critical role of vasodepression and/or cardioinhibition as final mechanisms of reflex syncope is emphasized. Current diagnostic approach sharply separates between cardiac and autonomic pathways. Physiologic insights have been translated, through rigorously designed clinical trials, into non-pharmacological or pharmacological interventions and interventional therapies. The following manuscript is intended to give the reader the current state of the art of knowledge of syncope by highlighting landmark contributions of the Europace journal.


Assuntos
Síncope Vasovagal , Síncope , Humanos , Síncope/diagnóstico , Síncope/etiologia , Síncope/terapia , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/terapia , Coração
6.
Cereb Cortex ; 32(8): 1608-1624, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-34518890

RESUMO

Comparative neuroimaging has been used to identify changes in white matter architecture across primate species phylogenetically close to humans, but few have compared the phylogenetically distant species. Here, we acquired postmortem diffusion imaging data from ring-tailed lemurs (Lemur catta), black-capped squirrel monkeys (Saimiri boliviensis), and rhesus macaques (Macaca mulatta). We were able to establish templates and surfaces allowing us to investigate sulcal, cortical, and white matter anatomy. The results demonstrate an expansion of the frontal projections of the superior longitudinal fasciculus complex in squirrel monkeys and rhesus macaques compared to ring-tailed lemurs, which correlates with sulcal anatomy and the lemur's smaller prefrontal granular cortex. The connectivity of the ventral pathway in the parietal region is also comparatively reduced in ring-tailed lemurs, with the posterior projections of the inferior longitudinal fasciculus not extending toward parietal cortical areas as in the other species. In the squirrel monkeys we note a very specific occipito-parietal anatomy that is apparent in their surface anatomy and the expansion of the posterior projections of the optical radiation. Our study supports the hypothesis that the connectivity of the prefrontal-parietal regions became relatively elaborated in the simian lineage after divergence from the prosimian lineage.


Assuntos
Substância Branca , Animais , Mapeamento Encefálico/métodos , Macaca mulatta , Vias Neurais/anatomia & histologia , Vias Neurais/diagnóstico por imagem , Lobo Parietal , Substância Branca/anatomia & histologia , Substância Branca/diagnóstico por imagem
7.
Clin Auton Res ; 33(6): 749-755, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37874434

RESUMO

PURPOSE: We compared hemodynamic parameters between subjects with marked, intermediate and minimal cardioinhibition during vasovagal syncope. METHODS: The study included subjects with a decrease in heart rate while experiencing a complete vasovagal syncope during tilt-table testing. The subjects were classified as having marked, intermediate or minimal cardioinhibition, based on tertile values of the decrease in heart rate. Hemodynamic parameters between these groups were compared before tilt in the supine position, shortly after tilt and during cardioinhibition. RESULTS: A total of 149 subjects with a median age of 43 (interquartile range 24-60) years were included in the study. Among the three groups with different levels of cardioinhibition, the highest heart rate was observed in subjects with marked cardioinhibition both before and shortly after tilt and at the start of cardioinhibition. The heart rate decrease in these subjects was both larger and faster compared to subjects with minimal and intermediate cardioinhibition. CONCLUSION: Subjects with marked cardioinhibition have both a larger and faster decrease in heart rate compared to subjects with intermediate and minimal cardioinhibition, as early as from the start of cardioinhibition. Marked cardioinhibition is related to differences in hemodynamic profiles already present well before the start of cardioinhibition.


Assuntos
Síncope Vasovagal , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Síncope Vasovagal/diagnóstico , Teste da Mesa Inclinada , Hemodinâmica/fisiologia , Frequência Cardíaca/fisiologia , Triazóis
8.
Neuroimage ; 262: 119535, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-35931306

RESUMO

To estimate microstructure-related parameters from diffusion MRI data, biophysical models make strong, simplifying assumptions about the underlying tissue. The extent to which many of these assumptions are valid remains an open research question. This study was inspired by the disparity between the estimated intra-axonal axial diffusivity from literature and that typically assumed by the Neurite Orientation Dispersion and Density Imaging (NODDI) model (d∥=1.7µm2/ms). We first demonstrate how changing the assumed axial diffusivity results in considerably different NODDI parameter estimates. Second, we illustrate the ability to estimate axial diffusivity as a free parameter of the model using high b-value data and an adapted NODDI framework. Using both simulated and in vivo data we investigate the impact of fitting to either real-valued or magnitude data, with Gaussian and Rician noise characteristics respectively, and what happens if we get the noise assumptions wrong in this high b-value and thus low SNR regime. Our results from real-valued human data estimate intra-axonal axial diffusivities of ∼2-2.5µm2/ms, in line with current literature. Crucially, our results demonstrate the importance of accounting for both a rectified noise floor and/or a signal offset to avoid biased parameter estimates when dealing with low SNR data.


Assuntos
Neuritos , Substância Branca , Axônios , Encéfalo , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Tensor de Difusão/métodos , Humanos
9.
Eur Heart J ; 42(17): 1654-1660, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33624801

RESUMO

Head-up tilt test (TT) has been used for >50 years to study heart rate/blood pressure adaptation to positional changes, to model responses to haemorrhage, to assess orthostatic hypotension, and to evaluate haemodynamic and neuroendocrine responses in congestive heart failure, autonomic dysfunction, and hypertension. During these studies, some subjects experienced syncope due to vasovagal reflex. As a result, tilt testing was incorporated into clinical assessment of syncope when the origin was unknown. Subsequently, clinical experience supports the diagnostic value of TT. This is highlighted in evidence-based professional practice guidelines, which provide advice for TT methodology and interpretation, while concurrently identifying its limitations. Thus, TT remains a valuable clinical asset, one that has added importantly to the appreciation of pathophysiology of syncope/collapse and, thereby, has improved care of syncopal patients.


Assuntos
Doenças do Sistema Nervoso Autônomo , Hipotensão Ortostática , Frequência Cardíaca , Humanos , Hipotensão Ortostática/diagnóstico , Síncope/diagnóstico , Síncope/etiologia , Teste da Mesa Inclinada
10.
J Cardiovasc Magn Reson ; 23(1): 4, 2021 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-33423681

RESUMO

BACKGROUND: Segment length in cine (SLICE) strain analysis on standard cardiovascular magnetic resonance (CMR) cine images was recently validated against gold standard myocardial tagging. The present study aims to explore predictive value of SLICE for cardiac resynchronization therapy (CRT) response. METHODS AND RESULTS: Fifty-seven patients with heart failure and left bundle branch block (LBBB) were prospectively enrolled in this multi-center study and underwent CMR examination before CRT implantation. Circumferential strains of the septal and lateral wall were measured by SLICE on short-axis cine images. In addition, timing and strain pattern parameters were assessed. After twelve months, CRT response was quantified by the echocardiographic change in left ventricular (LV) end-systolic volume (LVESV). In contrast to timing parameters, strain pattern parameters being systolic rebound stretch of the septum (SRSsep), systolic stretch index (SSIsep-lat), and internal stretch factor (ISFsep-lat) all correlated significantly with LVESV change (R - 0.56; R - 0.53; and R - 0.58, respectively). Of all strain parameters, end-systolic septal strain (ESSsep) showed strongest correlation with LVESV change (R - 0.63). Multivariable analysis showed ESSsep to be independently related to LVESV change together with age and QRSAREA. CONCLUSION: The practicable SLICE strain technique may help the clinician to estimate potential benefit from CRT by analyzing standard CMR cine images without the need for commercial software. Of all strain parameters, end-systolic septal strain (ESSsep) demonstrates the strongest correlation with reverse remodeling after CRT. This parameter may be of special interest in patients with non-strict LBBB morphology for whom CRT benefit is doubted.


Assuntos
Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Idoso , Idoso de 80 Anos ou mais , Bloqueio de Ramo/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Tomada de Decisão Clínica , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
11.
Europace ; 23(5): 797-805, 2021 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-33219671

RESUMO

AIMS: To assess in patients with transient loss of consciousness the diagnostic yield, accuracy, and safety of the structured approach as described in the ESC guidelines in a tertiary referral syncope unit. METHODS AND RESULTS: Prospective cohort study including 264 consecutive patients (≥18 years) referred with at least one self-reported episode of transient loss of consciousness and presenting to the syncope unit between October 2012 and February 2015. The study consisted of three phases: history taking (Phase 1), autonomic function tests (AFTs) (Phase 2), and after 1.5-year follow-up with assessment by a multidisciplinary committee (Phase 3). Diagnostic yield was assessed after Phases 1 and 2. Empirical diagnostic accuracy was measured for diagnoses according to the ESC guidelines after Phase 3. The diagnostic yield after Phase 1 (history taking) was 94.7% (95% CI: 91.1-97.0%, 250/264 patients) and increased to 97.0% (93.9-98.6%, 256/264 patients) after Phase 2. The overall diagnostic accuracy (as established in Phase 3) of the Phases 1 and 2 diagnoses was 90.6% (95% CI: 86.2-93.8%, 232/256 patients). No life-threatening conditions were missed. Three patients died, two unrelated to the cause of transient loss of consciousness, and one whom remained undiagnosed. CONCLUSION: A clinical work-up at a tertiary syncope unit using the ESC guidelines has a high diagnostic yield, accuracy, and safety. History taking (Phase 1) is the most important diagnostic tool. Autonomic function tests never changed the Phase 1 diagnosis but helped to increase the certainty of the Phase 1 diagnosis in many patients and yield additional diagnoses in patients who remained undiagnosed after Phase 1. Diagnoses were inaccurate in 9.4%, but no serious conditions were missed. This is adequate for clinical practice.


Assuntos
Serviço Hospitalar de Emergência , Síncope , Humanos , Estudos Prospectivos , Encaminhamento e Consulta , Síncope/diagnóstico
12.
Neuroimage ; 219: 116962, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32497785

RESUMO

Nonlinear registration is critical to many aspects of Neuroimaging research. It facilitates averaging and comparisons across multiple subjects, as well as reporting of data in a common anatomical frame of reference. It is, however, a fundamentally ill-posed problem, with many possible solutions which minimise a given dissimilarity metric equally well. We present a regularisation method capable of selectively driving solutions towards those which would be considered anatomically plausible by penalising unlikely lineal, areal and volumetric deformations. This penalty is symmetric in the sense that geometric expansions and contractions are penalised equally, which encourages inverse-consistency. We demonstrate that this method is able to significantly reduce local volume changes and shape distortions compared to state-of-the-art elastic (FNIRT) and plastic (ANTs) registration frameworks. Crucially, this is achieved whilst simultaneously matching or exceeding the registration quality of these methods, as measured by overlap scores of labelled cortical regions. Extensive leveraging of GPU parallelisation has allowed us to solve this highly computationally intensive optimisation problem while maintaining reasonable run times of under half an hour.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Neuroimagem/métodos , Algoritmos , Humanos
13.
Epilepsia ; 60(11): 2215-2223, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31637707

RESUMO

OBJECTIVE: To determine the incidence of clinically relevant arrhythmias in refractory focal epilepsy and to assess the potential of postictal arrhythmias as risk markers for sudden unexpected death in epilepsy (SUDEP). METHODS: We recruited people with refractory focal epilepsy without signs of ictal asystole and who had at least one focal seizure per month and implanted a loop recorder with 2-year follow-up. The devices automatically record arrhythmias. Subjects and caregivers were instructed to make additional peri-ictal recordings. Clinically relevant arrhythmias were defined as asystole ≥ 6 seconds; atrial fibrillation < 55 beats per minute (bpm), or > 200 bpm and duration > 30 seconds; persistent sinus bradycardia < 40 bpm while awake; and second- or third-degree atrioventricular block and ventricular tachycardia/fibrillation. We performed 12-lead electrocardiography (ECG) and tilt table testing to identify non-seizure-related causes of asystole. RESULTS: We included 49 people and accumulated 1060 months of monitoring. A total of 16 474 seizures were reported, of which 4679 were captured on ECG. No clinically relevant arrhythmias were identified. Three people had a total of 18 short-lasting (<6 seconds) periods of asystole, resulting in an incidence of 2.91 events per 1000 patient-months. None of these coincided with a reported seizure; one was explained by micturition syncope. Other non-clinically relevant arrhythmias included paroxysmal atrial fibrillation (n = 2), supraventricular tachycardia (n = 1), and sinus tachycardia with a right bundle branch block configuration (n = 1). SIGNIFICANCE: We found no clinically relevant arrhythmias in people with refractory focal epilepsy during long-term follow-up. The absence of postictal arrhythmias does not support the use of loop recorders in people at high SUDEP risk.


Assuntos
Epilepsia Resistente a Medicamentos/diagnóstico , Epilepsia Resistente a Medicamentos/fisiopatologia , Eletrocardiografia/tendências , Epilepsias Parciais/diagnóstico , Epilepsias Parciais/fisiopatologia , Adulto , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Epilepsia Resistente a Medicamentos/epidemiologia , Eletrocardiografia/métodos , Epilepsias Parciais/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Morte Súbita Inesperada na Epilepsia/epidemiologia , Fatores de Tempo , Adulto Jovem
14.
Europace ; 20(2): e1-e10, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28339818

RESUMO

Aims: Cardiac resynchronization therapy (CRT) reduces morbidity and mortality in systolic heart failure patients with ventricular conduction delay. Variability of individual response to CRT warrants improved patient selection. The Markers and Response to CRT (MARC) study was designed to investigate markers related to response to CRT. Methods and results: We prospectively studied the ability of 11 clinical, 11 electrocardiographic, 4 echocardiographic, and 16 blood biomarkers to predict CRT response in 240 patients. Response was measured by the reduction of indexed left ventricular end-systolic volume (LVESVi) at 6 months follow-up. Biomarkers were related to LVESVi change using log-linear regression on continuous scale. Covariates that were significant univariately were included in a multivariable model. The final model was utilized to compose a response score. Age was 67 ± 10 years, 63% were male, 46% had ischaemic aetiology, LV ejection fraction was 26 ± 8%, LVESVi was 75 ± 31 mL/m2, and QRS was 178 ± 23 ms. At 6 months LVESVi was reduced to 58 ± 31 mL/m2 (relative reduction of 22 ± 24%), 130 patients (61%) showed ≥ 15% LVESVi reduction. In univariate analysis 17 parameters were significantly associated with LVESVi change. In the final model age, QRSAREA (using vectorcardiography) and two echocardiographic markers (interventricular mechanical delay and apical rocking) remained significantly associated with the amount of reverse ventricular remodelling. This CAVIAR (CRT-Age-Vectorcardiographic QRSAREA -Interventricular Mechanical delay-Apical Rocking) response score also predicted clinical outcome assessed by heart failure hospitalizations and all-cause mortality. Conclusions: The CAVIAR response score predicts the amount of reverse remodelling after CRT and may be used to improve patient selection. Clinical Trials: NCT01519908.

15.
Cardiovasc Ultrasound ; 15(1): 25, 2017 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-29047378

RESUMO

BACKGROUND: Although mechanical dyssynchrony parameters derived by speckle tracking echocardiography (STE) may predict response to cardiac resynchronization therapy (CRT), comparability of parameters derived with different STE vendors is unknown. METHODS: In the MARC study, echocardiographic images of heart failure patients obtained before CRT implantation were prospectively analysed with vendor specific STE software (GE EchoPac and Philips QLAB) and vendor-independent software (TomTec 2DCPA). Response was defined as change in left ventricular (LV) end-systolic volume between examination before and six-months after CRT implantation. Basic longitudinal strain and mechanical dyssynchrony parameters (septal to lateral wall delay (SL-delay), septal systolic rebound stretch (SRSsept), and systolic stretch index (SSI)) were obtained from either separate septal and lateral walls, or total LV apical four chamber. Septal strain patterns were categorized in three types. The coefficient of variation and intra-class correlation coefficient (ICC) were analysed. Dyssynchrony parameters were associated with CRT response using univariate regression analysis and C-statistics. RESULTS: Two-hundred eleven patients were analysed. GE-cohort (n = 123): age 68 years (interquartile range (IQR): 61-73), 67% male, QRS-duration 177 ms (IQR: 160-192), LV ejection fraction: 26 ± 7%. Philips-cohort (n = 88): age 67 years (IQR: 59-74), 60% male, QRS-duration: 179 ms (IQR: 166-193), LV ejection fraction: 27 ± 8. LV derived peak strain was comparable in the GE- (GE: -7.3 ± 3.1%, TomTec: -6.4 ± 2.8%, ICC: 0.723) and Philips-cohort (Philips: -7.7 ± 2.7%, TomTec: -7.7 ± 3.3%, ICC: 0.749). SL-delay showed low ICC values (GE vs. TomTec: 0.078 and Philips vs. TomTec: 0.025). ICC's of SRSsept and SSI were higher but only weak (GE vs. TomTec: SRSsept: 0.470, SSI: 0.467) (Philips vs. QLAB: SRSsept: 0.419, SSI: 0.421). Comparability of septal strain patterns was low (Cohen's kappa, GE vs. TomTec: 0.221 and Philips vs. TomTec: 0.279). Septal strain patterns, SRSsept and SSI were associated with changes in LV end-systolic volume for all vendors. SRSsept and SSI had relative varying C-statistic values (range: 0.530-0.705) and different cut-off values between vendors. CONCLUSIONS: Although global longitudinal strain analysis showed fair comparability, assessment of dyssynchrony parameters was vendor specific and not applicable outside the context of the implemented platform. While the standardization taskforce took an important step for global peak strain, further standardization of STE is still warranted.


Assuntos
Ecocardiografia/instrumentação , Insuficiência Cardíaca/diagnóstico , Ventrículos do Coração/fisiopatologia , Volume Sistólico/fisiologia , Idoso , Terapia de Ressincronização Cardíaca/métodos , Módulo de Elasticidade , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Resultado do Tratamento
19.
Clin Physiol Funct Imaging ; 44(2): 119-130, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37839043

RESUMO

Tilt table testing (TTT) has been used for decades to study short-term blood pressure (BP) and heart rate regulation during orthostatic challenges. TTT provokes vasovagal reflex in many syncope patients as a background of widespread use. Despite the availability of evidence-based practice syncope guidelines, proper application and interpretation of TTT in the day-to-day care of syncope patients remain challenging. In this review, we offer practical information on what is needed to perform TTT, how results should be interpreted including the Vasovagal Syncope International Study classification, why syncope induction on TTT is necessary in patients with unexplained syncope and on indications for TTT in syncope patient care. The minimum requirements to perform TTT are a tilt table with an appropriate tilt-down time, a continuous beat-to-beat BP monitor with at least three electrocardiogram leads and trained staff. We emphasize that TTT remains a valuable asset that adds to history building but cannot replace it, and highlight the importance of recognition when TTT is abnormal even without syncope. Acknowledgement by the patient/eyewitness of the reproducibility of the induced attack is mandatory in concluding a diagnosis. TTT may be indicated when the initial syncope evaluation does not yield a certain, highly likely, or possible diagnosis, but raises clinical suspicion of (1) reflex syncope, (2) orthostatic hypotension (OH), (3) postural orthostatic tachycardia syndrome or (4) psychogenic pseudosyncope. A therapeutic indication for TTT in the patient with a certain, highly likely or possible diagnosis of reflex syncope, may be to educate patients on prodromes. In patients with reflex syncope with OH TTT can be therapeutic to recognize hypotensive symptoms causing near-syncope to perform physical countermanoeuvres for syncope prevention (biofeedback). Detection of hypotensive susceptibility requiring therapy is of special value.


Assuntos
Hipotensão Ortostática , Síncope Vasovagal , Humanos , Reprodutibilidade dos Testes , Teste da Mesa Inclinada/efeitos adversos , Teste da Mesa Inclinada/métodos , Síncope/diagnóstico , Síncope/terapia , Síncope/etiologia , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/terapia , Síncope Vasovagal/complicações , Hipotensão Ortostática/diagnóstico , Hipotensão Ortostática/terapia , Hipotensão Ortostática/complicações , Frequência Cardíaca
20.
Eur J Intern Med ; 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38789289

RESUMO

BACKGROUND: We aimed to identify the target of deprescribing, i.e. the 24-hour SBP increase needed to achieve the greatest reduction of SBP drops. METHOD: Forty hypertensive patients (mean age 73.6 ± 9.3 years, 26 females) with reflex syncope and SBP drops on a screening ABPM were advised to withdraw or to reduce their therapy. The study objective was the reduction of SBP drops <90 mmHg and <100 mmHg on a second ABPM performed within 3 months. RESULTS: Out of a total of 98 drugs taken during ABPM 1, 44 were withdrawn, 16 had a dose reduction and 38 remained unchanged at the time of ABPM 2. 24-hour SBP increased from 119.7 ± 10.1 mmHg to 129.4 ± 13.2 mmHg during ABPM2. Total disappearance of daytime SBP drops <100 mmHg was achieved in 20 (50 %) patients who had 24-hour SBP of 134±13 mmHg and an increase from ABPM 1 of 12 (IQR 5-20) mmHg. Compared with the 20 patients who had persistence of drops, these patients had a greater reduction of the number of hypotensive drugs (67 % versus 19 %, p = 0.002) and a greater rate of withdrawals (62 % versus 29 %, p = 0.003). CONCLUSION: In hypertensive patients with reflex syncope, an increase of 12 mmHg and an absolute value of 24-hour SBP of 134 mmHg appear to represent the optimal goals aimed to prevent SBP drops. Drugs withdrawal, rather than simply dose reduction, is mostly required to achieve the above target.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA