RESUMO
PURPOSE: Cervical total disc replacement (cTDR) has been established as an alternative treatment for degenerative cervical radiculopathy and myelopathy. While the rate of complications for cTDR is reasonably low, recent studies have focused on bone loss after cTDR. The purpose of this work is to develop a clinical management plan for cTDR patients with evidence of bone loss. To guide our recommendations, we undertook a review of the literature and aimed to determine: (1) how bone loss was identified/imaged, (2) whether pre- or intraoperative assessments of infection or histology were performed, and (3) what decision-making and revision strategies were employed. METHODS: We performed a search of the literature according to PRISMA guidelines. Included studies reported the clinical performance of cTDR and identified instances of cervical bone loss. RESULTS: Eleven case studies and 20 cohort studies were reviewed, representing 2073 patients with 821 reported cases of bone loss. Bone loss was typically identified on radiographs during routine follow-up or by computed tomography (CT) for patients presenting with symptoms. Assessments of infection as well as histological and/or explant assessment were sporadically reported. Across all reviewed studies, multiple mechanisms of bone loss were suspected, and severity and progression varied greatly. Many patients were reportedly asymptomatic, but others experienced symptoms like progressive pain and paresthesia. CONCLUSION: Our findings demonstrate a critical gap in the literature regarding the optimal management of patients with bone loss following cTDR, and treatment recommendations based on our review are impractical given the limited amount and quality evidence available. However, based on the authors' extensive clinical experience, close follow-up of specific radiographic observations and serial radiographs to assess the progression/severity of bone loss and implant changes are recommended. CT findings can be used for clinical decision-making and further follow-up care. The pattern and rate of progression of bone loss, in concert with patient symptomatology, should determine whether non-operative or surgical intervention is indicated. Future studies involving implant retrieval, histopathological, and microbiological analysis for patients undergoing cTDR revision for bone loss are needed.
Assuntos
Vértebras Cervicais , Substituição Total de Disco , Humanos , Substituição Total de Disco/métodos , Substituição Total de Disco/efeitos adversos , Vértebras Cervicais/cirurgia , Vértebras Cervicais/diagnóstico por imagem , Reabsorção Óssea/diagnóstico por imagem , Reabsorção Óssea/etiologia , Complicações Pós-Operatórias/etiologiaRESUMO
BACKGROUND: The pathophysiology and mechanisms driving the generation of unintended pain after total disc replacement (TDR) remain unexplored. Ultrahigh-molecular-weight polyethylene (UHMWPE) wear debris from TDRs is known to induce inflammation, which may result in pain. QUESTIONS/PURPOSES: The purpose of this study was to determine whether (1) periprosthetic UHMWPE wear debris induces immune responses that lead to the production of tumor necrosis factor-α (TNFα) and interleukin (IL)-1ß, the vascularization factors, vascular endothelial growth factor (VEGF) and platelet-derived growth factor-bb (PDGFbb), and the innervation/pain factors, nerve growth factor (NGF) and substance P; (2) the number of macrophages is associated with the production of the aforementioned factors; (3) the wear debris-induced inflammatory pathogenesis involves an increase in vascularization and associated innervation. METHODS: Periprosthetic tissues from our collection of 11 patients with contemporary TDRs were evaluated using polarized light microscopy to quantify UHMWPE wear particles. The major reason for revision (mean implantation time of 3 years [range, 1-6 years]) was pain. For control subjects, biopsy samples from four patients with degenerative disc disease with severe pain and autopsy samples from three normal patients with no history of back pain were also investigated. Immunohistochemistry and histology were used to identify secretory factors, macrophages, and blood vessels. Immunostained serial sections were imaged at ×200 magnification and using MATLAB and NIH ImageJ, a threshold was determined for each factor and used to quantify positive staining normalized to tissue sectional area. The Mann-Whitney U test was used to compare results from different patient groups, whereas the Spearman Rho test was used to determine correlations. Significance was based on p < 0.05. RESULTS: The mean percent area of all six inflammatory, vascularization, and innervation factors was higher in TDR tissues when compared with normal disc tissues. Based on nonparametric data analysis, those factors showing the most significant increase included TNFα (5.17 ± 1.76 versus 0.05 ± 0.03, p = 0.02), VEGF (3.02 ± 1.01 versus 0.02 ± 0.002, p = 0.02), and substance P (4.15 ± 1.01 versus 0.08 ± 0.04, p = 0.02). The mean percent area for IL-1ß (2.41 ± 0.66 versus 0.13 ± 0.13, p = 0.01), VEGF (3.02 ± 1.01 versus 0.34 ± 0.29, p = 0.04), and substance P (4.15 ± 1.01 versus 1.05 ± 0.46, p = 0.01) was also higher in TDR tissues when compared with disc tissues from patients with painful degenerative disc disease. Five of the factors, TNFα, IL-1ß, VEGF, NGF, and substance P, strongly correlated with the number of wear particles, macrophages, and blood vessels. The most notable correlations included TNFα with wear particles (p < 0.001, ρ = 0.63), VEGF with macrophages (p = 0.001, ρ = 0.71), and NGF with blood vessels (p < 0.001, ρ = 0.70). Of particular significance, the expression of PDGFbb, NGF, and substance P was predominantly localized to blood vessels/nerve fibers. CONCLUSIONS: These findings indicate wear debris-induced inflammatory reactions can be linked to enhanced vascularization and associated innervation/pain factor production at periprosthetic sites around TDRs. Elucidating the pathogenesis of inflammatory particle disease will provide information needed to identify potential therapeutic targets and treatment strategies to mitigate pain and potentially avoid revision surgery. LEVEL OF EVIDENCE: Level III, therapeutic study.
Assuntos
Discite/etiologia , Degeneração do Disco Intervertebral/cirurgia , Disco Intervertebral/cirurgia , Dor Lombar/etiologia , Vértebras Lombares/cirurgia , Dor Pós-Operatória/etiologia , Polietilenos , Substituição Total de Disco/efeitos adversos , Substituição Total de Disco/instrumentação , Adulto , Biópsia , Citocinas/metabolismo , Remoção de Dispositivo , Discite/diagnóstico , Discite/fisiopatologia , Discite/cirurgia , Feminino , Humanos , Imuno-Histoquímica , Mediadores da Inflamação/metabolismo , Disco Intervertebral/irrigação sanguínea , Disco Intervertebral/inervação , Disco Intervertebral/metabolismo , Degeneração do Disco Intervertebral/diagnóstico , Degeneração do Disco Intervertebral/fisiopatologia , Dor Lombar/diagnóstico , Dor Lombar/fisiopatologia , Dor Lombar/cirurgia , Vértebras Lombares/irrigação sanguínea , Vértebras Lombares/inervação , Vértebras Lombares/metabolismo , Macrófagos/metabolismo , Masculino , Pessoa de Meia-Idade , Neovascularização Patológica , Medição da Dor , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/fisiopatologia , Dor Pós-Operatória/cirurgia , Desenho de Prótese , Reoperação , Fatores de Risco , Estresse Mecânico , Substância P/metabolismo , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Fator A de Crescimento do Endotélio Vascular/metabolismo , Adulto JovemRESUMO
PURPOSE: Few complications have been reported for lumbar total disc replacement (TDR) and hybrid TDR fixations. This study evaluated retrieved implants and periprosthetic tissue reactions for two cases of osteolysis following disc arthroplasty with ProDisc-L prostheses. METHODS: Implants were examined for wear and surface damage, and tissues for inflammation, polyethylene wear debris (polarized light microscopy) and metal debris (energy-dispersive X-ray spectroscopy). RESULTS: Despite initial good surgical outcomes, osteolytic cysts were noted in both patients at vertebrae adjacent to the implants. For the hybrid TDR case, heterotopic ossification and tissue necrosis due to wear-induced inflammation were observed. In contrast, the non-hybrid implant showed signs of abrasion and impingement, and inflammation was observed in tissue regions with metal and polyethylene wear debris. CONCLUSIONS: In both cases, wear debris and inflammation may have contributed to osteolysis. Surgeons using ProDisc prostheses should be aware of these rare complications.
Assuntos
Prótese Articular/efeitos adversos , Vértebras Lombares/cirurgia , Osteólise/etiologia , Complicações Pós-Operatórias/etiologia , Substituição Total de Disco/instrumentação , Adulto , Remoção de Dispositivo , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/diagnóstico , Complicações Pós-Operatórias/diagnóstico , Falha de Prótese/efeitos adversos , Substituição Total de Disco/métodosRESUMO
BACKGROUND: Lumbar total disc replacement (L-TDR) is a procedure used to relieve back pain and maintain mobility. Contemporary metal-on-polyethylene (MoP) L-TDRs were developed to address wear performance concerns about historical designs, but wear debris generation and periprosthetic tissue reactions for these newer implants have not been determined. QUESTIONS/PURPOSES: The purpose of this study was to determine (1) whether periprosthetic ultrahigh-molecular-weight polyethylene (UHMWPE) wear debris and biological responses were present in tissues from revised contemporary MoP L-TDRs that contain conventional cores fabricated from γ-inert-sterilized UHMWPE; (2) how fixed- versus mobile-bearing design affected UHMWPE wear particle number, shape, and size; and (3) how these wear particle characteristics compare with historical MoP L-TDRs that contain cores fabricated from γ-air-sterilized UHMWPE. METHODS: We evaluated periprosthetic tissues from 11 patients who received eight fixed-bearing ProDisc-L and four mobile-bearing CHARITÉ contemporary L-TDRs with a mean implantation time of 4.1 and 2.7 years, respectively. Histologic analysis of tissues was performed to assess biological responses and polarized light microscopy was used to quantify number and size/shape characteristics of UHMWPE wear particles from the fixed- and mobile-bearing devices. Comparisons were made to previously reported particle data for historical L-TDRs. RESULTS: Five of seven (71%) fixed-bearing and one of four mobile-bearing L-TDR patient tissues contained at least 4 particles/mm(2) wear with associated macrophage infiltration. Tissues with wear debris were highly vascularized, whereas those without debris were more necrotic. Given the samples available, the tissue around mobile-bearing L-TDR was observed to contain 87% more, 11% rounder, and 11% less-elongated wear debris compared with tissues around fixed-bearing devices; however, there were no significant differences. Compared with historical L-TDRs, UHMWPE particle number and circularity for contemporary L-TDRs were 99% less (p = 0.003) and 50% rounder (p = 0.003). CONCLUSIONS: In this preliminary study, short-term results suggest there was no significant influence of fixed- or mobile-bearing designs on wear particle characteristics of contemporary L-TDRs, but conventional UHMWPE has notably improved the wear resistance of these devices compared with historical UHMWPE.
Assuntos
Disco Intervertebral/cirurgia , Vértebras Lombares/cirurgia , Teste de Materiais , Próteses e Implantes , Desenho de Prótese , Falha de Prótese , Substituição Total de Disco/instrumentação , Adulto , Materiais Biocompatíveis , Feminino , Humanos , Degeneração do Disco Intervertebral/cirurgia , Deslocamento do Disco Intervertebral/cirurgia , Dor Lombar/cirurgia , Masculino , Pessoa de Meia-Idade , PolietilenosRESUMO
BACKGROUND: The goal of this study is to propose a classification system with a common nomenclature for radiographic observations of periprosthetic bone changes following cTDR. METHODS: Aided by serial plain radiographs from recent cTDR cases (34 patients; 44 devices), a panel of experts assembled for the purpose of creating a classification system to aid in reproducibly and accurately identifying bony changes and assessing cTDR radiographic appearance. Subdividing the superior and inferior vertebral bodies into 3 equal sections, observed bone loss such as endplate rounding, cystic erosion adjacent to the endplate, and cystic erosion not adjacent to the endplate, is recorded. Determining if bone loss is progressive, based on serial radiographs, and estimating severity of bone loss (measured by the percentage of end plate involved) is recorded. Additional relevant bony changes and device observations include radiolucent lines, heterotopic ossification, vertebral body olisthesis, loss of core implant height, and presence of device migration, and subsidence. RESULTS: Serial radiographs from 19 patients (25 devices) implanted with a variety of cTDR designs were assessed by 6 investigators including clinicians and scientists experienced in cTDR or appendicular skeleton joint replacement. The overall agreement of assessments ranged from 49.9% (95% bootstrap confidence interval 45.1-73.1%) to 94.7% (95% CI 86.9-100.0%). There was reasonable agreement on the presence or absence of bone loss or radiolucencies (range: 58.4% (95% CI 51.5-82.7%) to 94.7% (95% CI 86.9-100.0%), as well as in the progression of radiolucent lines (82.9% (95% CI 74.4-96.5%)). CONCLUSIONS: The novel classification system proposed demonstrated good concordance among experienced investigators in this field and represents a useful advancement for improving reporting in cTDR studies.
Assuntos
Degeneração do Disco Intervertebral , Substituição Total de Disco , Humanos , Resultado do Tratamento , Discotomia , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Pescoço , Degeneração do Disco Intervertebral/cirurgiaRESUMO
BACKGROUND CONTEXT: Various total disc replacement (TDR) designs have been compared to anterior cervical discectomy and fusion (ACDF) with favorable short and long-term outcomes in FDA-approved investigational device exemption (IDE) trials. The unique design of M6-C, with a compressible viscoelastic nuclear core and an annular structure, has previously demonstrated favorable clinical outcomes through 24 months. PURPOSE: To evaluate the long-term safety and effectiveness of the M6-C compressible artificial cervical disc and compare to ACDF at 5 years. STUDY DESIGN: Prospective, multicenter, concurrently and historically controlled, FDA-approved IDE clinical trial. PATIENT SAMPLE: Subjects with one-level symptomatic degenerative cervical radiculopathy were enrolled and received M6-C (n=160) or ACDF (n=189) treatment as part of the IDE study. Safety outcomes were evaluated at 5 years for all subjects. The primary effectiveness endpoint was available at 5 years for 113 M6-C subjects and 106 ACDF controls. OUTCOME MEASURES: The primary endpoint of this analysis was composite clinical success (CCS) at 60 months. Secondary endpoints were function and pain (neck disability index, VAS), physical quality of life (SF-36, SF-12), safety, neurologic, and radiographic assessments. METHODS: Propensity score subclassification was used to control for selection bias and match baseline covariates of the control group to the M6-C subjects. Sixty-month CCS rates were estimated for each treatment group using a generalized linear model controlling for propensity score. RESULTS: At 5 years postoperatively, the M6-C treatment resulted in 82.3% CCS while the ACDF group showed 67.0% CCS (superiority p=.013). Secondary endpoints indicated that significantly more M6-C subjects achieved VAS neck and arm pain improvements and showed maintained or improved physical functioning on quality-of-life measures compared to baseline assessments. The M6-C group-maintained flexion-extension motion, with significantly greater increases from baseline disc height and disc angle than observed in the control group. The rates of M6-C subsequent surgical interventions (SSI; 3.1%) and definitely device- or procedure-related serious adverse events (SAE failure; 3.1%) were similar to ACDF rates (SSI=5.3%, SAE failure=4.8%; p>.05 for both). CONCLUSIONS: Subjects treated with the M6-C artificial disc demonstrated superior 5-year achievement of clinical success when compared to ACDF controls. In addition, significantly more subjects in the M6-C group showed improved pain and physical functioning scores than observed in ACDF subjects, with no difference in reoperation rates or safety outcomes.
Assuntos
Degeneração do Disco Intervertebral , Radiculopatia , Fusão Vertebral , Substituição Total de Disco , Humanos , Vértebras Cervicais/cirurgia , Discotomia/efeitos adversos , Discotomia/métodos , Seguimentos , Degeneração do Disco Intervertebral/cirurgia , Cervicalgia/cirurgia , Estudos Prospectivos , Qualidade de Vida , Radiculopatia/cirurgia , Fusão Vertebral/métodos , Substituição Total de Disco/efeitos adversos , Substituição Total de Disco/métodos , Resultado do TratamentoRESUMO
BACKGROUND CONTEXT: The functional goals of cervical disc arthroplasty (CDA) are to restore enough range of motion (ROM) to reduce the risk of accelerated adjacent segment degeneration but limit excessive motion to maintain a biomechanically stable index segment. This motion-range is termed the "Physiological mobility range." Clinical studies report postoperative ROM averaged over all study subjects but they do not report what proportion of reconstructed segments yield ROM in the Physiological mobility range following CDA surgery. PURPOSE: To calculate the proportion of reconstructed segments that yield flexion-extension ROM (FE-ROM) in the Physiological mobility range (defined as 5°-16°) by analyzing the 24-month postoperative data reported by clinical trials of various cervical disc prostheses. STUDY DESIGN/SETTING: Analysis of 24-month postoperative FE-ROM data from clinical trials. PATIENT SAMPLE: Data from 1,173 patients from single-level disc replacement clinical trials of 7 cervical disc prostheses. OUTCOME MEASURES: 24-month postoperative index-level FE-ROM. METHODS: The FE-ROM histograms reported in Food and Drug Administration-Investigational Device Exemption (FDA-IDE) submissions and available for this analysis were used to calculate the frequencies of implanted levels with postoperative FE-ROM in the following motion-ranges: Hypomobile (0°-4°), Physiological (5°-16°), and Hypermobile (≥17°). The ROM histograms also allowed calculation of the average ROM of implanted segments in each of the 3 motion-ranges. RESULTS: Only 762 of 1,173 patients (implanted levels) yielded 24-month postCDA FE-ROM in the physiological mobility range (5°-16°). The proportions ranged from 60% to 79% across the 7 disc-prostheses, with an average of 65.0%±6.2%. Three-hundred and two (302) of 1,173 implanted levels yielded ROM in the 0°-4° range. The proportions ranged from 15% to 38% with an average of 25.7%±8.9%. One-hundred and nine (109) of 1,173 implanted levels yielded ROM of ≥17° with a range of 2%-21% and an average proportion of 9.3%±7.9%. The prosthesis with built-in stiffness due to its nucleus-annulus design yielded the highest proportion (103/131, 79%) of implanted segments in the physiological mobility range, compared to the cohort average of 65% (p<.01). Sixty-five of the 350 (18.6%) discs implanted with the 2 mobile-core designs in this cohort yielded ROM≥17° as compared to the cohort average of 9.3% (109/1,173) (p<.05). At 2-year postCDA, the "hypomobile" segments moved on average 2.4±1.2°, those in the "physiological-mobility" group moved 9.4±3.2°, and the hypermobile segments moved 19.6±2.6°. CONCLUSIONS: Prosthesis design significantly influenced the likelihood of achieving FE-ROM in the physiological mobility range, while avoiding hypomobility or hypermobility (p<.01). Postoperative ROM averaged over all study subjects provides incomplete information about the prosthesis performance - it does not tell us how many implanted segments achieve physiological mobility and how many end up with hypomobility or hypermobility. We conclude that the proportion of index levels achieving postCDA motions in the physiological mobility range (5°-16°) is a more useful outcome measure for future clinical trials.
Assuntos
Vértebras Cervicais , Desenho de Prótese , Amplitude de Movimento Articular , Substituição Total de Disco , Humanos , Amplitude de Movimento Articular/fisiologia , Vértebras Cervicais/cirurgia , Substituição Total de Disco/métodos , Substituição Total de Disco/instrumentação , Disco Intervertebral/cirurgia , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Artroplastia/métodos , Resultado do Tratamento , Ensaios Clínicos como AssuntoRESUMO
Background: Total disc replacement (TDR) is widely used in the treatment of cervical and lumbar spine pathologies. Although TDR infection, particularly delayed infection, is uncommon, the results can be devastating, and consensus on clinical management remains elusive. In this review of the literature, we asked: (1) What are the reported rates of TDR infection; (2) What are the clinical characteristics of TDR infection; and (3) How has infection been managed for TDR patients? Methods: We performed a search of the literature using PubMed and Embase to identify studies that reported TDR infection rates, the identification and management of TDR infection, or TDR failures with positive cultures. Twenty database studies (17 focusing on the cervical spine and 3 on the lumbar spine) and 10 case reports representing 15 patients were reviewed along with device Summary of Safety and Effectiveness Data reports. Results: We found a lack of clarity regarding how infection was diagnosed, indicating a variation in clinical approach and highlighting the need for a standard definition of TDR infection. Furthermore, while reported infection rates were low, the absence of a clear definition prevented robust data analysis and may contribute to underreporting in the literature. We found that treatment strategy and success rely on several factors including patient symptoms and time to onset, microorganism type, and implant positioning/stability. Conclusions: Although treatment strategies varied throughout the extant literature, common practices in eliminating infection and reconstructing the spine emerged. The results will inform future work on the creation of a more robust definition of TDR infection and as well as recommendations for management.
RESUMO
INTRODUCTION: The purpose of this study was to analyze explanted PEEK rod spinal systems in the context of their clinical indications. We evaluated damage to the implant and histological changes in explanted periprosthetic tissues. METHODS: 12 patients implanted with 23 PEEK rods were revised between 2008 and 2012. PEEK rods were of the same design (CD Horizon Legacy, Medtronic, Memphis TN, USA). Retrieved components were assessed for surface damage mechanisms, including plastic deformation, scratching, burnishing, and fracture. Patient history and indications for PEEK rod implantation were obtained from analysis of the medical records. RESULTS: 11/12 PEEK rod systems were employed for fusion at one level, and motion preservation at the adjacent level. Surgical complications in the PEEK cohort included a small dural tear in one case that was immediately repaired. There were no cases of PEEK rod fracture or pedicle screw fracture. Retrieved PEEK rods exhibited scratching, as well as impressions from the set screws and pedicle screw saddles. PEEK debris was observed in two patient tissues, which were located adjacent to PEEK rods with evidence of scratching and burnishing. CONCLUSION: This study documents the surface changes and tissue reactions for retrieved PEEK rod stabilization systems. Permanent indentations by the set screws and pedicle screws were the most prevalent observations on the surface of explanted PEEK rods.
Assuntos
Análise de Falha de Equipamento/métodos , Vértebras Lombares/patologia , Vértebras Lombares/cirurgia , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Adulto , Benzofenonas , Parafusos Ósseos , Feminino , Humanos , Fixadores Internos , Degeneração do Disco Intervertebral/terapia , Cetonas , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Polietilenoglicóis , Polímeros , Estudos Prospectivos , Próteses e Implantes , Radiografia , Amplitude de Movimento Articular , ReoperaçãoRESUMO
Background: Motion of a solid body involves translation and rotation. Few investigations examine the isolated translational and rotational components associated with disc arthroplasty devices. This study investigates single- and multi-level cervical disc arthroplasty with respect to index and adjacent level range of motion. The investigators hypothesized that single- and multilevel cervical disc replacement will lead to comparable or improved motion at implanted and adjacent levels. Methods: Seven human cervical spines from C2 to C7 were subjected to displacement-controlled loading in flexion, extension, and lateral bending under intact, 1-Level (C5-C6), 2-Level (C5-C6, C6-C7) and 3-Level (C5-C6, C6-C7, C4-C5) conditions. 3D motions sensors were mounted at C4, C5, and C6. Motion data for translations and rotations at each level for each surgical condition and loading mode were compared to intact conditions. Results: 1-Level: The index surgery resulted in statistically increased translations in extension and lateral bending at all levels with statistically increased translation observed in flexion in the superior and inferior levels. In rotation, the index surgeries decreased rotation under flexion, with remaining levels not statistically different to intact conditions. 2-Level: A device placed inferiorly resulted in statistically increased translations at all levels in extension with statistically increased translations superior and inferior to the index level in flexion. Lateral bending resulted in increased nonsignificant translations. Rotations were elevated or comparable to the intact level for all loading. 3-Level: Translations were statistically increased for all levels in all loading modes while rotations were elevated or were comparable to the intact level for all loading modes and levels. Conclusions: Micromotion sensors permitted monitoring and recording of small magnitude angulations and translations using a loading mechanism that did not over constrain cervical segmental motion. Multilevel cervical disc arthroplasty yielded comparable or increased overall motion at the index and adjacent levels compared to intact conditions.
RESUMO
CASE: A 22-year-old woman with Klippel-Feil syndrome who underwent cervical disc arthroplasty (CDA) presented 3 months postoperatively with worsening neck pain and radiculopathy. Work-up was negative for infection, but single-photon emission computed tomography revealed increased metabolic activity in the vertebral body below the implant. During revision, the implant was grossly loose and multiple cultures grew Cutibacterium acnes. She was treated with an antibiotic course and conversion to anterior fusion without recurrence. CONCLUSION: This report highlights the rare presentation of an early periprosthetic infection after CDA caused by C. acnes.
Assuntos
Vértebras Cervicais , Radiculopatia , Feminino , Humanos , Adulto Jovem , Adulto , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Resultado do Tratamento , Artroplastia/métodos , Cervicalgia/etiologia , Radiculopatia/cirurgiaRESUMO
Knowledge regarding the in vivo performance and periposthetic tissue response of cervical and lumbar total disc replacements (TDRs) continues to expand. This review addresses the following four main questions: 1) What are the latest lessons learned from polyethylene in large joints and how are they relevant to current TDRs? 2) What are the latest lessons learned regarding adverse local tissue reactions from metal-on-metal, CoCr bearings in large joints and how are they relevant to current TDRs? 3) What advancements have been made in understanding the in vivo performance of alternative biomaterials, such as stainless steel and polycarbonate urethane, for TDRs in the past five years? 4) How has retrieval analysis of all these various artificial disc bearing technologies advanced the state of the art in preclinical testing of TDRs? The study of explanted artificial discs and their associated tissues can help inform bearing selection as well as the design of future generations of disc arthroplasty. Analyzing retrieved artificial discs is also essential for validating preclinical test methods.
RESUMO
BACKGROUND: Patients may occasionally have persistent or recurrent radicular symptoms after cervical artificial disc replacement (ADR) for cervical spondylotic radiculopathy. We describe our approach using anterior cervical foraminotomy (ACF) to provide symptom relief in such patients without the need to convert to a fusion or remove the ADR implant. METHODS: Our operative technique for ACF after cervical ADR begins by starting at the lateral edge of the ADR at the superior end plate of the inferior vertebral body. The ipsilateral uncovertebral joint is drilled with a combination of a high-speed burr and diamond-coated burr to minimize the risk of injury to the vertebral artery. The neuroforamen is entered after drilling through the posterior aspect of the uncinate process. The exiting cervical nerve root should be directly visualized, and a Kerrison rongeur may be used to trace along the nerve root laterally to remove any remaining uncinate osteophyte or process. We queried our internal database for patients with recurrent or new radicular pain following cervical ADR who underwent ACF. Clinical characteristics and outcomes were reported. RESULTS: Five patients with recurrent radicular symptoms after ADR were reviewed. Two ACFs were performed at C5-6, and 2 were performed at C6-7. Four patients developed ipsilateral recurrent radicular symptoms, and only 1 patient developed contralateral new radicular symptoms. Three patients reported complete resolution of their new or recurrent radicular symptoms following ACF, and 2 patients reported only partial resolution. No patients required conversion to a fusion. CONCLUSIONS: In patients with recurrent symptoms of cervical spondylotic radiculopathy following ADR, ACF with uncovertebral joint resection can be used to provide direct foraminal decompression without the need for implant removal. This approach also preserves motion at the affected level, preserves cervical spinal stability, and prevents the need for spinal fusion. CLINICAL RELEVANCE: Patients with persistent or recurrent radicular symptoms after cervical ADR may achieve resolution of symptoms through a modified ACF technique.
RESUMO
Background: Given the increased attention to functional improvement in spine surgery as it relates to motion preservation, activities of daily living, and cost, it is critical to fully understand the healthcare economic impact of new devices being tested in large FDA randomized controlled trials (RCT). The purpose of this analysis was to comprehensively evaluate the cost-effectiveness of the novel Total Posterior Spine (TOPS™) System investigational device compared with the trial control group, standard transforaminal lumbar interbody fusion (TLIF). Objective: To evaluate the cost-effectiveness of TOPS™ compared with TLIF. Methods: The study patient population was extracted from a multicenter RCT with current enrollment at n=121 with complete 1-year follow-up. The primary outcome was cost-effectiveness, expressed as the incremental cost-effectiveness ratio. Secondary outcomes were health-related utility, presented as quality-adjusted life-years (QALYs), and cost, calculated in US dollars. Analysis was conducted following Second Panel on Cost-Effectiveness Health and Medicine recommendations. The base case analysis utilized SF-36 survey data from the RCT. Both cost and QALY outcomes were discounted at a yearly rate of 3% to reflect their present value. A cohort Markov model was constructed to analyze perioperative and postoperative costs and QALYs for both TOPS™ and control groups. Scenario, probabilistic, and threshold sensitivity analyses were conducted to determine model discrimination and calibration. Results: The primary time horizon used to estimate cost and health utility was 2 years after index surgery. From a health system perspective, assuming a 50/50 split between Medicare and private payers, the TOPS™ cohort is cost-effective 2 years postoperatively ($6158/QALY) compared with control. At 6 years and beyond, TOPS™ becomes dominant, irrespective of payer mix and surgical setting. At willingness-to-pay thresholds of $100â¯000/QALY, 63% of all 5000 input parameter simulations favor TOPS, even with a $4000 upcharge vs TLIF. Discussion: The novel TOPS™ device is cost-effective compared with TLIF and becomes the dominant economic strategy over time. Conclusions: In the emerging, rapidly expanding field of value-based medicine, there will be an increased demand for these analyses, ensuring surgeons are empowered to make the best, most sustainable solutions for their patients and society.
RESUMO
BACKGROUND: Driving an automobile requires the ability to turn the neck laterally. Anecdotally, patients with multilevel fusions often complain about restricted turning motion. The purpose of this study was to compare the effectiveness of cervical disc arthroplasty (CDA) with anterior cervical discectomy and fusion (ACDF) on driving disability improvement at 10-year follow-up after a 2-level procedure. METHODS: In the original randomized controlled trial, patients with cervical radiculopathy or myelopathy at 2 levels underwent CDA or ACDF. The driving disability question from the Neck Disability Index was rated from 0 to 5 years preoperatively and up to 10 years postoperatively. Severity of driving disability was categorized into "none" (score 0), "mild" (1 or 2), and "severe" (3, 4, or 5). Score and severity were compared between groups. RESULTS: Out of 397 patients, 148 CDA and 118 ACDF patients had 10-year follow-up. Driving disability scores were not different between the groups preoperatively (CDA: 2.65; ACDF: 2.71, P = 0.699). Postoperatively, the scores in the CDA group were significantly lower than those in the ACDF group at 5 (0.60 vs 1.08, P ≤ 0.001) and 10 years (0.66 vs 1.07, P = 0.001). Mean score improvement in the CDA group was significantly greater than the ACDF group at 10-year follow-up (-1.94 vs -1.63, P = 0.003). The majority of patients reported severe driving disability (CDA: 56.9%, ACDF: 58.0%, P = 0.968) before surgery. After surgery, a greater proportion of patients in the CDA group had neck pain-free driving compared with the ACDF group at 5 (63.3% vs 41.8%, P < 0.001) and 10 years (61.8% vs 41.2%, P = 0.003). CONCLUSION: In patients with cervical radiculopathy/myelopathy and 2-level disease, CDA provided greater improvements in driving disability as compared with ACDF at 10-year follow-up. This is the first report of its kind. This finding may be attributable to preservation of motion associated with CDA. CLINICAL RELEVENCE: This study provides valuable information regarding the improvement of driving disability after both CDA and ACDF. It demonstrates that both procedures result in significant improvements, with CDA resulting in even better improvements than ACDF, up to 10 year follow-up.
RESUMO
The concept of semi-rigid fixation (SRF) has driven the development of spinal implants that utilize nonmetallic materials and novel rod geometries in an effort to promote fusion via a balance of stability, intra- and inter-level load sharing, and durability. The purpose of this study was to characterize the mechanical and biomechanical properties of a pedicle screw-based polyetheretherketone (PEEK) SRF system for the lumbar spine to compare its kinematic, structural, and durability performance profile against that of traditional lumbar fusion systems. Performance of the SRF system was characterized using a validated spectrum of experimental, computational, and in vitro testing. Finite element models were first used to optimize the size and shape of the polymeric rods and bound their performance parameters. Subsequently, benchtop tests determined the static and dynamic performance threshold of PEEK rods in relevant loading modes (flexion-extension (F/E), axial rotation (AR), and lateral bending (LB)). Numerical analyses evaluated the amount of anteroposterior column load sharing provided by both metallic and PEEK rods. Finally, a cadaveric spine simulator was used to determine the level of stability that PEEK rods provide. Under physiological loading conditions, a 6.35 mm nominal diameter oval PEEK rod construct unloads the bone-screw interface and increases anterior column load (approx. 75% anterior, 25% posterior) when compared to titanium (Ti) rod constructs. The PEEK construct's stiffness demonstrated a value lower than that of all the metallic rod systems, regardless of diameter or metallic composition (78% < 5.5 mm Ti; 66% < 4.5 mm Ti; 38% < 3.6 mm Ti). The endurance limit of the PEEK construct was comparable to that of clinically successful metallic rod systems (135N at 5 × 10(6) cycles). Compared to the intact state, cadaveric spines implanted with PEEK constructs demonstrated a significant reduction of range of motion in all three loading directions (> 80% reduction in F/E, p < 0.001; > 70% reduction in LB, p < 0.001; > 54% reduction in AR, p < 0.001). There was no statistically significant difference in the stability provided by the PEEK rods and titanium rods in any mode (p = 0.769 for F/E; p = 0.085 for LB; p = 0.633 for AR). The CD HORIZON(®) LEGACY(™) PEEK Rod System provided intervertebral stability comparable to currently marketed titanium lumbar fusion constructs. PEEK rods also more closely approximated the physiologic anteroposterior column load sharing compared to results with titanium rods. The durability, stability, strength, and biomechanical profile of PEEK rods were demonstrated and the potential advantages of SRF were highlighted.
Assuntos
Parafusos Ósseos , Cetonas , Vértebras Lombares/cirurgia , Teste de Materiais/métodos , Polietilenoglicóis , Fusão Vertebral/instrumentação , Benzofenonas , Fenômenos Biomecânicos , Análise de Elementos Finitos , Humanos , Polímeros , Reprodutibilidade dos Testes , Resistência ao Cisalhamento , Estresse MecânicoRESUMO
BACKGROUND: Single and multilevel lumbar arthroplasty has had excellent results, but the L5-S1 level frequently has pathology that precludes arthroplasty. This study evaluated clinical outcomes and sagittal range of motion (ROM) of operated levels and adjacent motion segments in single- and multiple-level ProDisc-L above a simultaneous L5-S1 fusion (hybrid) after a 2- to 6-year follow-up. METHODS: In this prospective cohort study, 46 patients underwent simultaneous lumbar total disc replacement (TDR) at one to three levels and anterior lumbar interbody fusion (ALIF) at L5-S1. Twenty-three patients had L5-S1 ALIF + L4-5 TDR, 19 patients had L5-S1 ALIF + two-level TDR, and 4 patients had L5-S1 ALIF + three-level TDR. Oswestry disability index (ODI) and visual analog scores (VAS) of patient satisfaction (VAS-S) and pain (VAS-P) were recorded. Sagittal motion on pre- and postoperative lumbar radiographs at each operative segment and adjacent segment was acquired. Patients were evaluated preoperatively and at 6 weeks, 3 months, 6 months, and annually for 24 to 72 months postoperatively. RESULTS: For clinical results, there were no differences among the groups for age, gender, body mass index, tobacco use, or worker's compensation status. At 2-6 years postoperation, all patients had significant reductions in ODI and VAS scores. For radiographic results, at the nonsurgical level adjacent to the TDR + ALIF constructs, the mean preoperative ROM was 9.40 ± 1.80° compared with 10.50 ± 2.25° postoperatively. The mean preoperative ROM at levels undergoing TDR was 10.4 ± 2.71° versus 12.6 ± 2.25° postoperatively. There was no statistically significant difference in ROM at each prosthetic motion segment between patients receiving one-, two-, or three-level TDR. The mean preoperative ROM at the L5-S1 segment to undergo fusion was 2.4 ± 2.44°, with all patients having a postoperative ROM of 0.00°. CONCLUSIONS: Multilevel TDR above an L5-S1 ALIF (hybrid procedure) preserves ROM at the individual TDR levels and does not reduce the fusion rate of the L5-S1 fused level. Most significantly, the nonoperative adjacent level maintains its preoperative ROM at 2-6 years postoperatively.
RESUMO
BACKGROUND CONTEXT: Various designs of total disc replacement (TDR) devices have been compared to anterior cervical discectomy and fusion (ACDF) with favorable outcomes in FDA-approved investigational device exemption trials. The design of M6-C with a compressible viscoelastic nuclear core and an annular structure is substantially different than prior designs and has previously demonstrated favorable kinematics and clinical outcomes in small case series. PURPOSE: To evaluate the safety and effectiveness of the novel M6-C compressible artificial cervical disc compared with ACDF for subjects with single-level degenerative cervical radiculopathy. STUDY DESIGN/SETTING: Prospective, multicenter, concurrently and historically controlled, FDA-approved investigational device exemption clinical trial. PATIENT SAMPLE: Subjects with one-level symptomatic degenerative cervical radiculopathy were enrolled and assigned to receive M6-C or ACDF. OUTCOME MEASURES: Pain and function (Neck Disability Index, VAS), quality of life (SF-36), safety, neurologic, and radiographic assessments of motion (both flexion extension and lateral bending) were performed. The primary clinical endpoint was composite clinical success (CCS) at 24 months. METHODS: Using propensity score subclassification to control for selection bias, 160 M6-C subjects were compared to a matched subset of 189 ACDF controls (46 concurrent and 143 historical controls). RESULTS: Both ACDF and M6-C subjects reported significant improvements in patient-reported outcomes at all time points over baseline. Overall SF-36 Physical Component Score and neck and arm pain scores were significantly improved for M6-C as compared to ACDF treatment. CCS and mean Neck Disability Index improvements were similar between M6-C and ACDF. Correspondingly, there were significantly fewer subjects that utilized pain medication or opioids following M6-C treatment at 24 months relative to baseline. Range of motion was maintained in subjects treated with M6-C. Subsequent surgical interventions, dysphagia rates, and serious adverse events were comparable between groups. CONCLUSIONS: M6-C treatment demonstrated both safety and effectiveness for the treatment of degenerative cervical radiculopathy. Treatment with M6-C demonstrated noninferiority for the primary endpoint, indicating a similar ability to achieve CCS at 24 months. However, for the secondary endpoints, M6-C subjects demonstrated significantly improved pain and function compared to ACDF subjects, while maintaining range of motion, improving quality of life, and decreasing analgesic and opioid usage at 2 years postoperatively relative to baseline.
Assuntos
Degeneração do Disco Intervertebral , Radiculopatia , Fusão Vertebral , Substituição Total de Disco , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Discotomia/efeitos adversos , Humanos , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/cirurgia , Estudos Prospectivos , Qualidade de Vida , Radiculopatia/cirurgia , Substituição Total de Disco/efeitos adversos , Resultado do TratamentoRESUMO
BACKGROUND: The frequency and complexity of spinal surgery performed in an ambulatory surgery center (ASC) is increasing. However, safety and efficacy data of most spinal procedures adapted to the ASC are sparse and have focused on anterior cervical surgery. The purpose of this study was to compare the 90-day complication and readmission rates of anterior lumbar spine surgery performed in an ASC or inpatient setting. METHODS: We performed a retrospective comparative analysis of 226 consecutive anterior lumbar surgeries (283 levels treated) completed in an ASC (n = 124) or in an inpatient tertiary care hospital (n = 102) over a 3-year period. These included anterior lumbar interbody fusion (ALIF), artificial disc replacement (ADR), and hybrids. Patients undergoing simultaneous or staged posterior procedures within 3 months were excluded. Patient demographics and surgical parameters between the two surgical settings were compared. Ninety-day medical complications and readmission rates were assessed. One-way analysis of variance and Chi-square analysis were used. A P value of less than .05 was considered statistically significant. RESULTS: The two study groups had similar baseline characteristics. While there was a trend toward fewer complications, reoperations, and readmissions for the ASC cohort, the differences were not statistically significant. There were 7 intraoperative complications (5.6% minor vascular injury) in the inpatient cohort and 0 in the ASC cohort. The overall 90-day postoperative complication rate was 5.6% for the inpatient cohort and 0.9% for the ASC cohort. The 90-day readmission rate was 1.9% in the ASC cohort and 1.6% in the inpatient cohort. The 90-day reoperation rate was 0.8% for the inpatient cohort and 0% in the ASC cohort. The average hospital stay was 2.3 ± 1.5 days for the inpatient cohort. CONCLUSION: The 90-day readmission rates were lower for outpatients than for inpatients, while the complication and reoperation rates were similar. Our results demonstrate that anterior lumbar procedures, including single-level and multilevel ALIF, ADR, and hybrid procedures, can be performed safely in an ASC. This has significant cost savings implications for the ASC setting.
RESUMO
STUDY DESIGN: Retrospective cohort. OBJECTIVE: Evaluate the safety profile of single- and multilevel cervical artificial disc replacement (ADR) performed in an outpatient setting. SUMMARY OF BACKGROUND DATA: As healthcare costs rise, attempts are made to perform an increasing proportion of spine surgery in ambulatory surgery centers (ASCs). ASCs are more efficient, economically and functionally. Few studies have published on the safety profile of multilevel cervical ADR. METHODS: We have performed an analysis of all consecutive cervical ADR surgeries that we performed in an ASC over a 9-month period, including multilevel and revision surgery. The pre-, intra-, and postoperative data recorded included age, sex, body mass index, tobacco use, and diabetes; level and procedure, operating room time, estimated blood loss (EBL), and complications; and discharge site, occurrence of reoperation, hospital admission, or any medical complication or infection over a 90-day period. RESULTS: A total of 147 patients underwent 231 treated levels: 71 single-level, 76 multilevel: 69 two-level, 6 three-level, and 1 four-level. Average age was 50â±â10 years; 71 women, 76 men. None of the patients had insulin-dependent diabetes, 4 were current smokers, and 16 were former smokers. Average body mass index was 26.8â±â4.6 (range 18-40). Average total anesthesia time was 88 minutes (range 39-168 min). Average EBL was 15âmL (range 5-100âmL). Approximately 90.3% of patients were discharged directly home, 9.7% to an aftercare facility. In the 90-day postoperative period there were zero deaths and two hospital admissions (1.4%)-one for medical complication (0.7%) and one for a surgical site infection (0.7%). CONCLUSION: In this consecutive case series we performed 231 ADRs in 147 patients in the outpatient setting, including multilevel and revision procedures, with 2 minor postoperative complications resulting in hospital unplanned admissions within 90 days. We believe that these procedures are safe to perform in an ASC. An efficient surgical team and careful patient selection criteria are critical in making this possible. LEVEL OF EVIDENCE: 3.