Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 159
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Am J Transplant ; 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38615901

RESUMO

Normothermic machine perfusion (NMP) is increasingly considered for pretransplant kidney quality assessment. However, fundamental questions about differences between in vivo and ex vivo renal function, as well as the impact of ischemic injury on ex vivo physiology, remain unanswered. This study utilized magnetic resonance imaging (MRI), alongside conventional parameters to explore differences between in vivo and ex vivo renal function and the impact of warm ischemia on a kidney's behavior ex vivo. Renal MRI scans and samples were obtained from living pigs (n = 30) in vivo. Next, kidney pairs were procured and exposed to minimal, or 75 minutes of warm ischemia, followed by 6 hours of hypothermic machine perfusion. Both kidneys simultaneously underwent 6-hour ex vivo perfusion in MRI-compatible NMP circuits to obtain multiparametric MRI data. Ischemically injured ex vivo kidneys showed a significantly altered regional blood flow distribution compared to in vivo and minimally damaged organs. Both ex vivo groups showed diffusion restriction relative to in vivo. Our findings underscore the differences between in vivo and ex vivo MRI-based renal characteristics. Therefore, when assessing organ viability during NMP, it should be considered to incorporate parameters beyond the conventional functional markers that are common in vivo.

2.
Magn Reson Med ; 91(6): 2204-2228, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38441968

RESUMO

MRI with hyperpolarized (HP) 13C agents, also known as HP 13C MRI, can measure processes such as localized metabolism that is altered in numerous cancers, liver, heart, kidney diseases, and more. It has been translated into human studies during the past 10 years, with recent rapid growth in studies largely based on increasing availability of HP agent preparation methods suitable for use in humans. This paper aims to capture the current successful practices for HP MRI human studies with [1-13C]pyruvate-by far the most commonly used agent, which sits at a key metabolic junction in glycolysis. The paper is divided into four major topic areas: (1) HP 13C-pyruvate preparation; (2) MRI system setup and calibrations; (3) data acquisition and image reconstruction; and (4) data analysis and quantification. In each area, we identified the key components for a successful study, summarized both published studies and current practices, and discuss evidence gaps, strengths, and limitations. This paper is the output of the "HP 13C MRI Consensus Group" as well as the ISMRM Hyperpolarized Media MR and Hyperpolarized Methods and Equipment study groups. It further aims to provide a comprehensive reference for future consensus, building as the field continues to advance human studies with this metabolic imaging modality.


Assuntos
Imageamento por Ressonância Magnética , Ácido Pirúvico , Humanos , Ácido Pirúvico/metabolismo , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador , Coração , Fígado/diagnóstico por imagem , Fígado/metabolismo , Isótopos de Carbono/metabolismo
3.
NMR Biomed ; 37(5): e5107, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38279190

RESUMO

Hyperpolarized carbon-13 labeled compounds are increasingly being used in medical MR imaging (MRI) and MR imaging (MRI) and spectroscopy (MRS) research, due to its ability to monitor tissue and cell metabolism in real-time. Although radiological biomarkers are increasingly being considered as clinical indicators, biopsies are still considered the gold standard for a large variety of indications. Bioreactor systems can play an important role in biopsy examinations because of their ability to provide a physiochemical environment that is conducive for therapeutic response monitoring ex vivo. We demonstrate here a proof-of-concept bioreactor and microcoil receive array setup that allows for ex vivo preservation and metabolic NMR spectroscopy on up to three biopsy samples simultaneously, creating an easy-to-use and robust way to simultaneously run multisample carbon-13 hyperpolarization experiments. Experiments using hyperpolarized [1-13C]pyruvate on ML-1 leukemic cells in the bioreactor setup were performed and the kinetic pyruvate-to-lactate rate constants ( k PL ) extracted. The coefficient of variation of the experimentally found k PL s for five repeated experiments was C V = 35 % . With this statistical power, treatment effects of 30%-40% change in lactate production could be easily differentiable with only a few hyperpolarization dissolutions on this setup. Furthermore, longitudinal experiments showed preservation of ML-1 cells in the bioreactor setup for at least 6 h. Rat brain tissue slices were also seen to be preserved within the bioreactor for at least 1 h. This validation serves as the basis for further optimization and upscaling of the setup, which undoubtedly has huge potential in high-throughput studies with various biomarkers and tissue types.


Assuntos
Análise do Fluxo Metabólico , Ácido Pirúvico , Ratos , Animais , Isótopos de Carbono , Ácido Pirúvico/metabolismo , Ácido Láctico/metabolismo , Reatores Biológicos , Biomarcadores
4.
NMR Biomed ; 37(5): e5110, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38317333

RESUMO

Early biomarkers of cerebral damage are essential for accurate prognosis, timely intervention, and evaluation of new treatment modalities in newborn infants with hypoxia and ischemia at birth. Hyperpolarized 13C magnetic resonance imaging (MRI) is a novel method with which to quantify metabolism in vivo with unprecedented sensitivity. We aimed to investigate the applicability of hyperpolarized 13C MRI in a newborn piglet model and whether this method may identify early changes in cerebral metabolism after a standardized hypoxic-ischemic (HI) insult. Six piglets were anesthetized and subjected to a standardized HI insult. Imaging was performed prior to and 2 h after the insult on a 3-T MR scanner. For 13C studies, [1-13C]pyruvate was hyperpolarized in a commercial polarizer. Following intravenous injection, images were acquired using metabolic-specific imaging. HI resulted in a metabolic shift with a decrease in pyruvate to bicarbonate metabolism and an increase in pyruvate to lactate metabolism (lactate/bicarbonate ratio, mean [SD]; 2.28 [0.36] vs. 3.96 [0.91]). This is the first study to show that hyperpolarized 13C MRI can be used in newborn piglets and applied to evaluate early changes in cerebral metabolism after an HI insult.


Assuntos
Hipóxia-Isquemia Encefálica , Recém-Nascido , Lactente , Animais , Humanos , Suínos , Hipóxia-Isquemia Encefálica/diagnóstico por imagem , Bicarbonatos , Imageamento por Ressonância Magnética/métodos , Modelos Animais , Hipóxia , Ácido Láctico/metabolismo , Ácido Pirúvico/metabolismo
5.
J Magn Reson Imaging ; 59(5): 1603-1611, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37656067

RESUMO

BACKGROUND: MRI can provide information on kidney structure, perfusion, and oxygenation. Furthermore, it allows for the assessment of kidney sodium concentrations and handling, allowing multiparametric evaluation of kidney physiology. Multiparametric MRI is promising for establishing prognosis and monitoring treatment responses in kidney diseases, but its intraindividual variation during the day is unresolved. PURPOSE: To investigate the variation in multiparametric MRI measurements from the morning to the evening. STUDY TYPE: Prospective. POPULATION: Ten healthy volunteers, aged 29 ± 5 without history of kidney disease. FIELD STRENGTH/SEQUENCE: 3 T/T1 mapping, blood-oxygen level dependent imaging, arterial spin labeling perfusion imaging, diffusion weighted imaging, and sodium imaging. ASSESSMENT: A multiparametric MRI protocol, yielding T1, R2*, ADC, renal blood flow and renal sodium levels, was acquired in the morning, noon, and evening. The participants were fasting prior to the first examination. Urine biochemical analyses were performed to complement MRI data. The cortex and medulla were analyzed separately in a semi-automatic fashion, and gradients of total sodium concentration (TSC) and R2* gradients were calculated from outer cortex to inner medulla. STATISTICAL TEST: Analyses of variance and mixed-effects models to estimate differences from time of day. Coefficients of variation to assess variability within and between participants. A P-value <0.05 was considered statistically significant. RESULTS: The coefficients of variation varied from 5% to 18% for proton-based parametric sequences, while it was 38% for TSC over a day. DATA CONCLUSION: Multiparametric MRI is stable over the day. The coefficients of variation over a day were lower for proton multiparametric MRI, but higher for sodium MRI. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Assuntos
Nefropatias , Imageamento por Ressonância Magnética Multiparamétrica , Humanos , Voluntários Saudáveis , Estudos Prospectivos , Prótons , Rim/fisiologia , Imageamento por Ressonância Magnética/métodos , Perfusão , Sódio
6.
Diabetologia ; 66(5): 813-825, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36746803

RESUMO

AIMS/HYPOTHESIS: Glucagon-like peptide-1 receptor agonists (GLP-1ras) and sodium-glucose cotransporter 2 inhibitors (SGLT2is) have shown kidney-protective effects. Improved kidney oxygenation and haemodynamic changes are suggested mechanisms; however, human data are scarce. We therefore investigated whether semaglutide (GLP-1ra), empagliflozin (SGLT2i) or their combination improve kidney oxygenation and perfusion. METHODS: The trial was undertaken at Aarhus University Hospital, Denmark. A total of 120 people with type 2 diabetes (HbA1c ≥48 mmol/mol [6.5%]) and at high risk of CVD (age ≥50 years) were randomised into four parallel groups (n=30 in each group) for 32 weeks: 1.0 mg semaglutide (open label); 10 mg empagliflozin (blinded to participants, caregivers, examiners and outcome assessors); their combination (1.0 mg semaglutide open label plus 10 mg empagliflozin blinded to participants, caregivers, examiners and outcome assessors); and placebo tablet (blinded to participants, caregivers, examiners and outcome assessors). Sequentially numbered, sealed envelopes containing computer-generated randomisation codes, provided by Glostrup Pharmacy, Glostrup, Denmark, determined the intervention. The two co-primary outcomes were change in kidney oxygenation and change in arterial stiffness. This paper reports on kidney oxygenation, for which 80 individuals as prespecified, 20 in each group, underwent MRI. We primarily hypothesised that kidney oxygenation would be improved in the active treatment groups compared with placebo after 32 weeks. Secondary outcomes included changes in kidney perfusion, erythropoietin, haematocrit, urine albumin/creatinine ratio (UACR) and GFR (measured using technetium-99m) compared with baseline and between treatment groups at week 32. RESULTS: Our model estimated a common baseline R2* value across all four groups in the cortex and the medulla. At baseline, the value was 24.5 (95% CI 23.9, 24.9) Hz in the medulla. After 32 weeks, the R2* values in the medulla were estimated to be 25.4 (95% CI 24.7, 26.2) Hz in the empagliflozin group and 24.5 (95% CI 23.9, 25.1) Hz in the placebo group (p=0.016) (higher R2* corresponds to a lower oxygenation). Semaglutide decreased perfusion in both the cortex and the medulla. Empagliflozin increased erythropoietin and haematocrit. All three active treatments decreased GFR but not UACR. Ten serious adverse events were reported, among them two occurrences of semaglutide-associated obstipation. CONCLUSIONS/INTERPRETATION: Our hypothesis, that semaglutide, empagliflozin or their combination improve kidney oxygenation, was rejected. On the contrary, empagliflozin induced a reduction in medullary kidney oxygenation. Semaglutide substantially reduced kidney perfusion without affecting oxygenation. TRIAL REGISTRATION: Clinicaltrialsregister.eu EudraCT 2019-000781-38 FUNDING: Novo Nordisk Foundation, Central Denmark Region Research Fund and Danish Medical Associations Research Foundation.


Assuntos
Diabetes Mellitus Tipo 2 , Eritropoetina , Humanos , Pessoa de Meia-Idade , Diabetes Mellitus Tipo 2/complicações , Hipoglicemiantes/efeitos adversos , Rim , Perfusão , Eritropoetina/uso terapêutico , Resultado do Tratamento , Método Duplo-Cego
7.
Magn Reson Med ; 90(2): 664-672, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37094025

RESUMO

PURPOSE: Hyperpolarized [1-13 C]pyruvate MRI is an emerging clinical tool for metabolic imaging. It has the potential for absolute quantitative metabolic imaging. However, the method itself is not quantitative, limiting comparison of images across both time and between individuals. Here, we propose a simple signal normalization to the whole-body oxidative metabolism to overcome this limitation. THEORY AND METHODS: A simple extension of the model-free ratiometric analysis of hyperpolarized [1-13 C]pyruvate MRI is presented, using the expired 13 CO2 in breath for normalization. The proposed framework was investigated in two porcine cohorts (N = 11) subjected to local renal hypoperfusion defects and subsequent [1-13 C]pyruvate MRI. A breath sample was taken before the [1-13 C]pyruvate injection and 5 min after. The raw MR signal from both the healthy and intervened kidney in the two cohorts was normalized using the 13 CO2 in the expired air. RESULTS: 13 CO2 content in the expired air was significantly different between the two cohorts. Normalization to this reduced the coefficients of variance in the aerobic metabolic sensitive pathways by 25% for the alanine/pyruvate ratio, and numerical changes were observed in the bicarbonate/pyruvate ratio. The lactate/pyruvate ratio was largely unaltered (<2%). CONCLUSION: Our results indicate that normalizing the hyperpolarized 13 C-signal ratios by the 13 CO2 content in expired air can reduce variation as well as improve specificity of the method by normalizing the metabolic readout to the overall metabolic status of the individual. The method is a simple and cheap extension to the hyperpolarized 13 C exam.


Assuntos
Dióxido de Carbono , Imageamento por Ressonância Magnética , Animais , Suínos , Imageamento por Ressonância Magnética/métodos , Ácido Pirúvico/metabolismo , Rim/diagnóstico por imagem , Rim/metabolismo , Isótopos de Carbono/metabolismo
8.
Magn Reson Med ; 89(3): 1265-1277, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36321576

RESUMO

PURPOSE: This article presents a novel 14-channel receive-only array for 13 C human head imaging at 3 T that explores the SNR gain by operating at cryogenic temperature cooled by liquid nitrogen. METHODS: Cryostats are developed to evaluate single-coil bench SNR performance and cool the 14-channel array with liquid nitrogen while having enough thermal insulation between the coils and the sample. The temperature distribution for the coil array is measured. Circuits are adapted to the -189°C environment and implemented in the 14-channel array. 13 C images are acquired with the array at cryogenic and room temperature in a 3T scanner. RESULTS: Compared with room temperature, the array at cryogenic temperature provides 27%-168% SNR improvement over all voxels and 47% SNR improvement near the image center. The measurements show a decrease of the element noise correlation at cryogenic temperature. CONCLUSION: It is demonstrated that higher SNR can be achieved by cryogenically cooling the 14-channel array. A cryogenic array suitable for clinical imaging can be further developed on the array proposed. The cryogenic coil array is most likely suited for scenarios in which high SNR deep in a head and decent SNR on the periphery are required.


Assuntos
Temperatura Baixa , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Nitrogênio , Imagens de Fantasmas , Razão Sinal-Ruído , Desenho de Equipamento
9.
Magn Reson Med ; 90(2): 655-663, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36971340

RESUMO

PURPOSE: Ischemic injury in the kidney is a common pathophysiological event associated with both acute kidney injury and chronic kidney disease; however, regional ischemia-reperfusion as seen in thromboembolic renal disease is often undetectable and thus subclinical. Here, we assessed the metabolic alterations following subclinical focal ischemia-reperfusion injury with hyperpolarized [1-13 C]pyruvate MRI in a porcine model. METHODS: Five pigs were subjected to 60 min of focal kidney ischemia. After 90 min of reperfusion, a multiparametric proton MRI protocol was performed on a clinical 3T scanner system. Metabolism was evaluated using 13 C MRI following infusion of hyperpolarized [1-13 C]pyruvate. Ratios of pyruvate to its detectable metabolites (lactate, bicarbonate, and alanine) were used to quantify metabolism. RESULTS: The focal ischemia-reperfusion injury resulted in injured areas with a mean size of 0.971 cm3 (±1.019). Compared with the contralateral kidney, the injured areas demonstrated restricted diffusion (1269 ± 83.59 × 10-6 mm2 /s vs. 1530 ± 52.73 × 10-6 mm2 /s; p = 0.006) and decreased perfusion (158.8 ± 29.4 mL/100 mL/min vs. 274 ± 63.1 mL/100 mL/min; p = 0.014). In the metabolic assessment, the injured areas displayed increased lactate/pyruvate ratios compared with the entire ipsilateral and the contralateral kidney (0.35 ± 0.13 vs. 0.27 ± 0.1 vs. 0.25 ± 0.1; p = 0.0086). Alanine/pyruvate ratio was unaltered, and we were unable to quantify bicarbonate due to low signal. CONCLUSION: MRI with hyperpolarized [1-13 C]pyruvate in a clinical setup is capable of detecting the acute, subtle, focal metabolic changes following ischemia. This may prove to be a valuable future addition to the renal MRI suite.


Assuntos
Ácido Pirúvico , Traumatismo por Reperfusão , Animais , Suínos , Ácido Pirúvico/metabolismo , Bicarbonatos/metabolismo , Rim/diagnóstico por imagem , Rim/metabolismo , Imageamento por Ressonância Magnética/métodos , Traumatismo por Reperfusão/diagnóstico por imagem , Ácido Láctico/metabolismo , Alanina/metabolismo
10.
Magn Reson Med ; 90(6): 2539-2556, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37526128

RESUMO

PURPOSE: X-nuclei (also called non-proton MRI) MRI and spectroscopy are limited by the intrinsic low SNR as compared to conventional proton imaging. Clinical translation of x-nuclei examination warrants the need of a robust and versatile tool improving image quality for diagnostic use. In this work, we compare a novel denoising method with fewer inputs to the current state-of-the-art denoising method. METHODS: Denoising approaches were compared on human acquisitions of sodium (23 Na) brain, deuterium (2 H) brain, carbon (13 C) heart and brain, and simulated dynamic hyperpolarized 13 C brain scans, with and without additional noise. The current state-of-the-art denoising method Global-local higher order singular value decomposition (GL-HOSVD) was compared to the few-input method tensor Marchenko-Pastur principal component analysis (tMPPCA). Noise-removal was quantified by residual distributions, and statistical analyses evaluated the differences in mean-square-error and Bland-Altman analysis to quantify agreement between original and denoised results of noise-added data. RESULTS: GL-HOSVD and tMPPCA showed similar performance for the variety of x-nuclei data analyzed in this work, with tMPPCA removing ˜5% more noise on average over GL-HOSVD. The mean ratio between noise-added and denoising reproducibility coefficients of the Bland-Altman analysis when compared to the original are also similar for the two methods with 3.09 ± 1.03 and 2.83 ± 0.79 for GL-HOSVD and tMPPCA, respectively. CONCLUSION: The strength of tMPPCA lies in the few-input approach, which generalizes well to different data sources. This makes the use of tMPPCA denoising a robust and versatile tool in x-nuclei imaging improvements and the preferred denoising method.

11.
Magn Reson Med ; 90(6): 2233-2241, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37665726

RESUMO

PURPOSE: To investigate high-resolution hyperpolarized (HP) 13 C pyruvate MRI for measuring cerebral perfusion in the human brain. METHODS: HP [1-13 C]pyruvate MRI was acquired in five healthy volunteers with a multi-resolution EPI sequence with 7.5 × 7.5 mm2 resolution for pyruvate. Perfusion parameters were calculated from pyruvate MRI using block-circulant singular value decomposition and compared to relative cerebral blood flow calculated from arterial spin labeling (ASL). To examine regional perfusion patterns, correlations between pyruvate and ASL perfusion were performed for whole brain, gray matter, and white matter voxels. RESULTS: High resolution 7.5 × 7.5 mm2 pyruvate images were used to obtain relative cerebral blood flow (rCBF) values that were significantly positively correlated with ASL rCBF values (r = 0.48, 0.20, 0.28 for whole brain, gray matter, and white matter voxels respectively). Whole brain voxels exhibited the highest correlation between pyruvate and ASL perfusion, and there were distinct regional patterns of relatively high ASL and low pyruvate normalized rCBF found across subjects. CONCLUSION: Acquiring HP 13 C pyruvate metabolic images at higher resolution allows for finer spatial delineation of brain structures and can be used to obtain cerebral perfusion parameters. Pyruvate perfusion parameters were positively correlated to proton ASL perfusion values, indicating a relationship between the two perfusion measures. This HP 13 C study demonstrated that hyperpolarized pyruvate MRI can assess cerebral metabolism and perfusion within the same study.


Assuntos
Imageamento por Ressonância Magnética , Ácido Pirúvico , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Perfusão , Marcadores de Spin , Circulação Cerebrovascular
12.
NMR Biomed ; 36(2): e4835, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36115017

RESUMO

Sodium MRI allows the non-invasive quantification of intra-organ sodium concentration. RF inhomogeneity introduces uncertainty in this estimated concentration. B1 field corrections can be used to overcome some of these limitations. However, the low signal-to-noise ratio in sodium MRI makes accurate B1 mapping in reasonable scan times challenging. The study aims to evaluate Bloch-Siegert off-resonance (BLOSI) B1 field correction for sodium MRI using a 3D Fermat looped, orthogonally encoded trajectories (FLORET) read-out trajectory. We propose a clinically feasible B1 field map correction method for sodium imaging at 3 T, evaluating five healthy subjects' brain, heart blood, kidneys, and thigh muscle. We scanned the subjects twice for repeatability measures and used sodium phantoms to determine organ total sodium concentration. Conventional proton scans were compared with sodium images for organ structural integrity. The BLOSI approach based on the 3D FLORET read-out trajectory was used in B1 field correction and 3D density-adapted radial acquisition for sodium imaging. Results indicate improvements in sodium imaging based on B1 field correction in a clinically feasible protocol. Improvements are determined in all organs by enhanced anatomical representation, organ homogeneity, and an increase in the total sodium concentration after applying a B1 field correction. The proposed BLOSI-based B1 field correction using a 3D FLORET read-out trajectory is clinically feasible for sodium imaging, which is shown in the brain, heart, kidney, and thigh muscle. This supports using fast B1 field mapping in the clinical setting.


Assuntos
Imageamento por Ressonância Magnética , Sódio , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Coração , Imagens de Fantasmas
13.
NMR Biomed ; 36(2): e4838, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36151711

RESUMO

Chronic kidney disease (CKD) is common and has huge implications for health and mortality. It is aggravated by intrarenal fibrosis, but the assessment of fibrosis is limited to kidney biopsies, which carry a risk of complications and sampling errors. This calls for a noninvasive modality for diagnosing and staging intrarenal fibrosis. The current, exploratory study evaluates a multiparametric MRI protocol including sodium imaging (23 Na-MRI) to determine the opportunities within this modality to assess kidney injury as a surrogate endpoint of fibrosis. The study includes 43 pigs exposed to ischemia-reperfusion injury (IRI) or unilateral ureteral obstruction (UUO), or serving as healthy controls. Fibrosis was determined using gene expression analysis of collagen. The medulla/cortex ratio of 23 Na-MRI decreased in the injured kidney in the IRI pigs, but not in the UUO pigs (p = 0.0180, p = 0.0754). To assess the combination of MRI parameters in estimating fibrosis, we created a linear regression model consisting of the cortical apparent diffusion coefficient, ΔR2*, ΔT1, the 23 Na medulla/cortex ratio, and plasma creatinine (R2  = 0.8009, p = 0.0117). The 23 Na medulla/cortex ratio only slightly improved the fibrosis prediction model, leaving 23 Na-MRI in an ambiguous place for evaluation of intrarenal fibrosis. Use of multiparametric MRI in combination with plasma creatinine shows potential for the estimation of fibrosis in human kidney disease, but more translational and clinical work is warranted before MRI can contribute to earlier diagnosis and evaluation of treatment for acute kidney injury and CKD.


Assuntos
Insuficiência Renal Crônica , Obstrução Ureteral , Humanos , Animais , Suínos , Prótons , Creatinina , Rim/diagnóstico por imagem , Rim/patologia , Imageamento por Ressonância Magnética/métodos , Obstrução Ureteral/diagnóstico por imagem , Obstrução Ureteral/patologia , Insuficiência Renal Crônica/diagnóstico por imagem , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/patologia , Fibrose , Modelos Animais de Doenças
14.
Nephrol Dial Transplant ; 38(3): 691-699, 2023 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-35612982

RESUMO

BACKGROUND: Diabetic kidney disease (DKD) accounts for ∼50% of end-stage kidney disease. Renal hypoxia is suggested as a main driver in the pathophysiology underlying chronic DKD. Blood oxygenation level-dependent magnetic resonance imaging (BOLD-MRI) has made noninvasive investigations of renal oxygenation in humans possible. Whether diabetes per se contributes to measurable changes in renal oxygenation by BOLD-MRI remains to be elucidated. We investigated whether renal oxygenation measured with BOLD-MRI differs between people with type 2 diabetes (T2DM) with normal to moderate chronic kidney disease (CKD) (Stages 1-3A) and matched controls. The repeatability of the BOLD-MRI method was also assessed. METHODS: In this matched cross-sectional study, 20 people with T2DM (age 69.2 ± 4.7 years, duration of diabetes 10.5 ± 6.7 years, male 55.6%) and 20 matched nondiabetic controls (mean age 68.8 ± 5.4 years, male 55.%) underwent BOLD-MRI analysed with the 12-layer concentric object method (TLCO). To investigate the repeatability, seven in the T2DM group and nine in the control group were scanned twice. RESULTS: A significant reduction in renal oxygenation from the cortex to medulla was found in both groups (P < .01) but no intergroup difference was detected [0.71/s (95% confidence interval -0.28-1.7), P = .16]. The median intraindividual coefficient of variation (CV) varied from 1.2% to 7.0%. CONCLUSION: T2DM patients with normal to moderate CKD do not seem to have lower renal oxygenation when measured with BOLD-MRI and TLCO. BOLD-MRI has a low intraindividual CV and seems like a reliable method for investigation of renal oxygenation in T2DM.


Assuntos
Diabetes Mellitus Tipo 2 , Insuficiência Renal Crônica , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Estudos Transversais , Rim , Imageamento por Ressonância Magnética/métodos , Oxigênio
15.
Artif Organs ; 47(1): 105-116, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35996889

RESUMO

BACKGROUND: The shortage of donor organs for transplantation remains a worldwide problem. The utilization of suboptimal deceased donors enlarges the pool of potential organs, yet consequently, clinicians face the difficult decision of whether these sub-optimal organs are of sufficient quality for transplantation. Novel technologies could play a pivotal role in making pre-transplant organ assessment more objective and reliable. METHODS: Ex vivo normothermic machine perfusion (NMP) at temperatures around 35-37°C allows organ quality assessment in a near-physiological environment. Advanced magnetic resonance imaging (MRI) techniques convey unique information about an organ's structural and functional integrity. The concept of applying magnetic resonance imaging during renal normothermic machine perfusion is novel in both renal and radiological research and we have developed the first MRI-compatible NMP setup for human-sized kidneys. RESULTS: We were able to obtain a detailed and real-time view of ongoing processes inside renal grafts during ex vivo perfusion. This new technique can visualize structural abnormalities, quantify regional flow distribution, renal metabolism, and local oxygen availability, and track the distribution of ex vivo administered cellular therapy. CONCLUSION: This platform allows for advanced pre-transplant organ assessment, provides a new realistic tool for studies into renal physiology and metabolism, and may facilitate therapeutic tracing of pharmacological and cellular interventions to an isolated kidney.


Assuntos
Transplante de Rim , Preservação de Órgãos , Humanos , Perfusão/métodos , Preservação de Órgãos/métodos , Rim/diagnóstico por imagem , Transplante de Rim/métodos , Imageamento por Ressonância Magnética
16.
Magn Reson Med ; 88(3): 1170-1179, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35533254

RESUMO

PURPOSE: To investigate the potential effects of [1-13 C]lactate RF saturation pulses on [13 C]bicarbonate detection in hyperpolarized [1-13 C]pyruvate MRI of the brain. METHODS: Thirteen healthy rats underwent MRI with hyperpolarized [1-13 C]pyruvate of either the brain (n = 8) or the kidneys, heart, and liver (n = 5). Dynamic, metabolite-selective imaging was used in a cross-over experiment in which [1-13 C]lactate was excited with either 0° or 90° flip angles. The [13 C]bicarbonate SNR and apparent [1-13 C]pyruvate-to-[13 C]bicarbonate conversion (kPB ) were determined. Furthermore, simulations were performed to identify the SNR optimal flip-angle scheme for detection of [1-13 C]lactate and [13 C]bicarbonate. RESULTS: In the brain, the [13 C]bicarbonate SNR was 64% higher when [1-13 C]lactate was not excited (5.8 ± 1.5 vs 3.6 ± 1.3; 1.2 to 3.3-point increase; p = 0.0027). The apparent kPB decreased 25% with [1-13 C]lactate saturation (0.0047 ± 0.0008 s-1 vs 0.0034 ± 0.0006 s-1 ; 95% confidence interval, 0.0006-0.0019 s-1 increase; p = 0.0049). These effects were not present in the kidneys, heart, or liver. Simulations suggest that the optimal [13 C]bicarbonate SNR with a TR of 1 s in the brain is obtained with [13 C]bicarbonate, [1-13 C]lactate, and [1-13 C]pyruvate flip angles of 60°, 15°, and 10°, respectively. CONCLUSIONS: Radiofrequency saturation pulses on [1-13 C]lactate limit [13 C]bicarbonate detection in the brain specifically, which could be due to shuttling of lactate from astrocytes to neurons. Our results have important implications for experimental design in studies in which [13 C]bicarbonate detection is warranted.


Assuntos
Bicarbonatos , Ácido Pirúvico , Animais , Encéfalo/diagnóstico por imagem , Isótopos de Carbono , Ácido Láctico , Imageamento por Ressonância Magnética/métodos , Ratos
17.
Magn Reson Med ; 88(2): 890-900, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35426467

RESUMO

PURPOSE: Hyperpolarized 13 C MRI is a powerful technique to study dynamic metabolic processes in vivo; but it has predominantly been used in mammals, mostly humans, pigs, and rodents. METHODS: In the present study, we use this technique to characterize the metabolic fate of hyperpolarized [1-13 C]pyruvate in Burmese pythons (Python bivittatus), a large species of constricting snake that exhibits a four- to tenfold rise in metabolism and large growth of the visceral organs within 24-48 h of ingestion of their large meals. RESULTS: We demonstrate a fivefold elevation of the whole-body lactate-to-pyruvate ratio in digesting snakes, pointing to a large rise in lactate production from pyruvate. Consistent with the well-known metabolic stimulation of digestion, measurements of mitochondrial respiration in hepatocytes in vitro indicate a marked postprandial upregulation of mitochondrial respiration. We observed that a low SNR of the hyperpolarized 13 C produced metabolites in the python, and this lack of signal was possibly due to the low metabolism of reptiles compared with mammals, preventing quantification of alanine and bicarbonate production with the experimental setup used in this study. Spatial quantification of the [1-13 C]lactate was only possible in postprandial snakes (with high metabolism), where a statistically significant difference between the heart and liver was observed. CONCLUSION: We confirm the large postprandial rise in the wet mass of most visceral organs, except for the heart, and demonstrated that it is possible to image the [1-13 C]pyruvate uptake and intracellular conversion to [1-13 C]lactate in ectothermic animals.


Assuntos
Boidae , Ácido Pirúvico , Animais , Boidae/metabolismo , Isótopos de Carbono/metabolismo , Digestão , Ácido Láctico/metabolismo , Imageamento por Ressonância Magnética/métodos , Mamíferos/metabolismo , Ácido Pirúvico/metabolismo , Suínos
18.
Magn Reson Med ; 87(2): 896-903, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34554602

RESUMO

PURPOSE: The number of glomeruli is different in men and women, as they also present different prevalence and progression of chronic kidney disease. A recent study has demonstrated a potential difference in renal metabolism between sexes, and a potential explanation could be the differences in glomeruli number. This study investigates the potential correlation between glomerular number and pyruvate metabolism in healthy kidneys. METHODS: This study is an experimental study with rats (N = 12). We used cationized-ferritin MRI to visualize and count glomeruli and hyperpolarized [1-13 C]pyruvate to map the metabolism. Dynamic contrast-enhanced MRI was used to analyze kidney hemodynamics using gadolinium tracer. RESULTS: Data showed no or subtle correlation between the number of glomeruli and the pyruvate metabolism. Minor differences were observed in the number of glomeruli (female = 24,509 vs. male = 26 350; p = .16), renal plasma flow (female = 606.6 vs. male= 455.7 ml/min/100 g; p = .18), and volume of distribution (female = 87.44 vs. male = 76.61 ml/100 ml; p = .54) between sexes. Mean transit time was significantly prolonged in males compared with females (female = 8.868 s vs. male = 10.63 s; p = .04). CONCLUSION: No strong statistically significant correlation between the number of glomeruli and the pyruvate metabolism was found in healthy rat kidneys.


Assuntos
Nefropatias , Glomérulos Renais , Animais , Feminino , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Ácido Pirúvico , Ratos
19.
Magn Reson Med ; 88(3): 1391-1405, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35635156

RESUMO

PURPOSE: To develop a coil-based method to obtain accurate sensitivity profiles in 13 C MRI at 3T from the endogenous 23 Na. An eight-channel array is designed for 13 C MR acquisitions. As application examples, the array is used for two-fold accelerated acquisitions of both hyperpolarized 13 C metabolic imaging of pig kidneys and the human brain. METHODS: A flexible coil array was tuned optimally for 13 C at 3T (32.1 MHz), with the coil coupling coefficients matched to be nearly identical at the resonance frequency of 23 Na (33.8 MHz). This is done by enforcing a high decoupling (obtained through highly mismatched preamplifiers) and adjusting the coupling frequency response. The SNR performance is compared to reference coils. RESULTS: The measured sensitivity profiles on a phantom showed high spatial similarity for 13 C and 23 Na resonances, with average noise correlation of 9 and 11%, respectively. For acceleration factors 2, 3, and 4, the obtained maximum g-factors were 1.0, 1.1, and 2.6, respectively. The 23 Na profiles obtained in vivo could be used successfully to perform two-fold acceleration of hyperpolarized 13 C 3D acquisitions of both pig kidneys and a healthy human brain. CONCLUSION: A receive array has been developed in such a way that the 13 C sensitivity profiles could be accurately obtained from measurements at the 23 Na frequency. This technique facilitates accelerated acquisitions for hyperpolarized 13 C imaging. The SNR performance obtained at the 13 C frequency, compares well to other state-of-the-art coils for the same purpose, showing slightly better superficial and central SNR.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Animais , Encéfalo/diagnóstico por imagem , Desenho de Equipamento , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Razão Sinal-Ruído , Suínos
20.
Magn Reson Med ; 87(1): 57-69, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34378800

RESUMO

PURPOSE: Hyperpolarized [1-13 C]pyruvate MRS can measure cardiac metabolism in vivo. We investigated whether [1-13 C]pyruvate MRS could predict left ventricular remodeling following myocardial infarction (MI), long-term left ventricular effects of heart failure medication, and could identify responders to treatment. METHODS: Thirty-five rats were scanned with hyperpolarized [1-13 C]pyruvate MRS 3 days after MI or sham surgery. The animals were re-examined after 30 days of therapy with ß-blockers and ACE-inhibitors (active group, n = 12), placebo treatment (placebo group, n = 13) or no treatment (sham group, n = 10). Furthermore, heart tissue mitochondrial respiratory capacity was assessed by high-resolution respirometry. Metabolic results were compared between groups, over time and correlated to functional MR data at each time point. RESULTS: At 30 ± 0.5 days post MI, left ventricular ejection fraction (LVEF) differed between groups (sham, 77% ± 1%; placebo, 52% ± 3%; active, 63% ± 2%, P < .001). Cardiac metabolism, measured by both hyperpolarized [1-13 C]pyruvate MRS and respirometry, neither differed between groups nor between baseline and follow-up. Three days post MI, low bicarbonate + CO2 /pyruvate ratio was associated with low LVEF. At follow-up, in the active group, a poor recovery of LVEF was associated with high bicarbonate + CO2 /pyruvate ratio, as measured by hyperpolarized MRS. CONCLUSION: In a rat model of moderate heart failure, medical treatment improved function, but did not on average influence [1-13 C]pyruvate flux as measured by MRS; however, responders to heart failure medication had reduced capacity for carbohydrate metabolism.


Assuntos
Insuficiência Cardíaca , Infarto do Miocárdio , Animais , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/tratamento farmacológico , Espectroscopia de Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/tratamento farmacológico , Miocárdio , Ácido Pirúvico , Ratos , Volume Sistólico , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA