Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Gen Intern Med ; 37(9): 2308-2313, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35713808

RESUMO

BACKGROUND: Point-of-care ultrasound (POCUS) training has been increasing among internal medicine (IM) residency programs, but few programs can provide longitudinal training due to barriers such as lack of trained faculty. AIM: Describe the development of a longitudinal POCUS track for IM residents using local and external resources, including a national POCUS certificate program. SETTING: University-based IM residency program affiliated with a public and veterans affairs hospital. PARTICIPANTS: Twelve IM residents from 2018 to 2021. PROGRAM DESCRIPTION: Residents complete a national POCUS certificate program by attending live courses and completing online modules, an image portfolio, and final knowledge/skills assessments. Locally, residents participate in 1-month procedure and diagnostic POCUS rotations and provide peer-to-peer POCUS teaching of residents and medical students. PROGRAM EVALUATION: The POCUS track increased residents' use and comfort with diagnostic and procedural applications. All residents rated being satisfied or very satisfied with the track and would recommend it to prospective applicants (100%). The most commonly reported barriers to utilizing POCUS per residents were time constraints (83%), lack of available ultrasound equipment (83%), and lack of trained faculty (58%). DISCUSSION: IM residency programs with limited faculty expertise in POCUS can leverage external resources to provide longitudinal POCUS training to its residents.


Assuntos
Internato e Residência , Estudantes de Medicina , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Ultrassonografia/métodos
2.
J Elder Abuse Negl ; 25(4): 294-304, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23768413

RESUMO

We have previously described high rates of executive function impairment in clients referred by Adult Protective Services (APS) to geriatric psychiatry for decision-making capacity assessments. The purpose of this study was to determine the independent relationship between neuropsychological screening instruments, particularly instruments sensitive to executive function, and performance-based functional tasks in elder referrals. Our retrospective medical review (n = 75/157 referrals completed all neuropsychological and functional assessments) revealed that only the Executive Interview (EXIT25) contributed independent variance to money management performance (R(2) = 0.29, p < 0.001), telephone use ability (R(2) = 0.39, p < 0.001), and summed performance (R(2) = 0.45, p < 0.001). Executive instruments may specifically inform decision-making capacity assessments.


Assuntos
Atividades Cotidianas/psicologia , Abuso de Idosos/psicologia , Função Executiva , Avaliação Geriátrica , Idoso , Idoso de 80 Anos ou mais , Cognição , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos
3.
Ultrasound J ; 14(1): 27, 2022 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-35796842

RESUMO

BACKGROUND: Point-of-care ultrasound (POCUS) is rapidly becoming ubiquitous across healthcare specialties. This is due to several factors including its portability, immediacy of results to guide clinical decision-making, and lack of radiation exposure to patients. The recent growth of handheld ultrasound devices has improved access to ultrasound for many clinicians. Few studies have directly compared different handheld ultrasound devices among themselves or to cart-based ultrasound machines. We conducted a prospective observational study comparing four common handheld ultrasound devices for ease of use, image quality, and overall satisfaction. Twenty-four POCUS experts utilized four handheld devices (Butterfly iQ+™ by Butterfly Network Inc., Kosmos™ by EchoNous, Vscan Air™ by General Electric, and Lumify™ by Philips Healthcare) to obtain three ultrasound views on the same standardized patients using high- and low-frequency probes. RESULTS: Data were collected from 24 POCUS experts using all 4 handheld devices. No single ultrasound device was superior in all categories. For overall ease of use, the Vscan Air™ was rated highest, followed by the Lumify™. For overall image quality, Lumify™ was rated highest, followed by Kosmos™. The Lumify™ device was rated highest for overall satisfaction, while the Vscan Air™ was rated as the most likely to be purchased personally and carried in one's coat pocket. The top 5 characteristics of handheld ultrasound devices rated as being "very important" were image quality, ease of use, portability, total costs, and availability of different probes. CONCLUSIONS: In a comparison of four common handheld ultrasound devices in the United States, no single handheld ultrasound device was perceived to have all desired characteristics. POCUS experts rated the Lumify™ highest for image quality and Vscan Air™ highest for ease of use. Overall satisfaction was highest with the Lumify™ device, while the most likely to be purchased as a pocket device was the Vscan Air™. Image quality was felt to be the most important characteristic in evaluating handheld ultrasound devices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA