Sensors (Basel) ; 18(12)2018 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-30477260

RESUMO

A new type of quasi-distributed sensor system is implemented using an active mode locking (AML) laser cavity with multiple partially reflecting segments. The mode locking frequency of the AML laser is linearly proportional to the overall lasing cavity length. To implement multiple resonators having multiple reflection points installed in a sensing fiber, two types of partial reflectors (PRs) are implemented for an in-line configuration, one with fiber Bragg grating and the other with a fiber Fabry⁻Perot interferometer. Since the laser has oscillated only when the modulation frequencies for the mode locking frequency match with the corresponding resonator lengths, it is possible to read the multiple partially reflecting segments along the sensing fiber. The difference between two corresponding mode locking frequencies is changing proportionally with the segment length variation between two PRs upon strain application. The segment length change caused by the applied strain can be successfully measured with a linear sensitivity between mode locking frequency and displacement, linearity over 0.99, and spatial position resolution below meter order.

2.
Opt Express ; 24(2): 1053-61, 2016 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-26832489

RESUMO

High-speed frequency-domain terahertz (THz) coherence tomography is demonstrated using frequency sweeping of continuous-wave THz radiation and beam steering. For axial scanning, THz frequency sweeping with a kHz sweep rate and a THz sweep range is executed using THz photomixing with an optical beat source consisting of a wavelength-swept laser and a distributed feedback laser diode. During the frequency sweep, frequency-domain THz interferograms are measured using coherent homodyne detection employing signal averaging for noise reduction and used as axial-scan data via fast Fourier transform. Axial-scan data are acquired while scanning a transverse range of 100 × 100 mm(2) by use of a THz beam scanner with moving neither sample nor THz transmitter/receiver unit. It takes 100 s to acquire axial-scan data for 100 × 100 points with 5 averaged traces at a sweep rate of 1 kHz. THz tomographic images of a glass fiber reinforced polymer sample with artificial internal defects are presented, acquired using the tomography system.

3.
Opt Lett ; 39(21): 6094-7, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-25361287

RESUMO

We demonstrate a novel concept of wavelength-spacing tuning of a dual-wavelength active-mode locking fiber laser in the 1.3-µm wavelength region. A dual-cavity configuration is implemented using a chirped fiber Bragg grating pair for wavelength-spacing tuning. Both normal and anomalous dispersion cavities were schematically designed for wavelength-spacing tuning ranging from 3.52-33.54 nm. The side-mode suppression ratio was ∼30 dB for both wavelengths. Because of the filter-less tuning mechanism, a fast repletion rate of wavelength-spacing sweeping and switching was demonstrated for frequencies up to 50 kHz.


Assuntos
Tecnologia de Fibra Óptica , Lasers , Fenômenos Ópticos
4.
Sensors (Basel) ; 14(9): 16109-16, 2014 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-25177803

RESUMO

A linearized wavelength-swept thermo-optic laser chip was applied to demonstrate a fiber Bragg grating (FBG) sensor interrogation system. A broad tuning range of 11.8 nm was periodically obtained from the laser chip for a sweep rate of 16 Hz. To measure the linear time response of the reflection signal from the FBG sensor, a programmed driving signal was directly applied to the wavelength-swept laser chip. The linear wavelength response of the applied strain was clearly extracted with an R-squared value of 0.99994. To test the feasibility of the system for dynamic measurements, the dynamic strain was successfully interrogated with a repetition rate of 0.2 Hz by using this FBG sensor interrogation system.

5.
Sci Rep ; 9(1): 3921, 2019 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-30850674

RESUMO

Distributed optical fiber sensors (DOFS) based on Raman, Brillouin, and Rayleigh scattering have recently attracted considerable attention for various sensing applications, especially large-scale monitoring, owing to their capacity for measuring strain or temperature distributions. However, ultraweak backscatter signals within optical fibers constitute an inevitable problem for DOFS, thereby increasing the burden on the entire system in terms of limited spatial resolution, low measurement speed, high system complexity, or high cost. We propose a novel resonance frequency mapping for a real-time quasi-distributed fiber optic sensor based on identical weak fiber Bragg gratings (FBG), which has stronger reflection signals and high sensitivity to multiple sensing parameters. The resonance configuration, which amplifies optical signals during multiple round-trip propagations, can simply and efficiently address the intrinsic problems in conventional single round-trip measurements for identical weak FBG sensors, such as crosstalk and optical power depletion. Moreover, it is technically feasible to perform individual measurements for a large number of quasi-distributed identical weak FBGs with relatively high signal-to-noise ratio (SNR), low crosstalk, and low optical power depletion. By mapping the resonance frequency spectrum, the dynamic response of each identical weak FBG is rapidly acquired in the order of kilohertz, and direct interrogation in real time is possible without time-consuming computation, such as fast Fourier transformation (FFT). This resonance frequency spectrum is obtained on the basis of an all-fiber electro-optic configuration that allows simultaneous measurement of quasi-distributed strain responses with high speed (>5 kHz), high stability (~2.4 µÎµ), and high linearity (R2 = 0.9999).

6.
Sci Rep ; 8(1): 17660, 2018 12 05.
Artigo em Inglês | MEDLINE | ID: mdl-30518926

RESUMO

Optical coherence tomography (OCT) is a noninvasive imaging modality that can provide high-resolution, cross-sectional images of tissues. Especially in retinal imaging, OCT has become one of the most valuable imaging tools for diagnosing eye diseases. Considering the scattering and absorption properties of the eye, the 1000-nm OCT system is preferred for retinal imaging. In this study, we describe the use of an akinetic swept-source OCT system based on a pulse-modulated active mode locking (AML) fiber laser at a 1080-nm wavelength for in-vivo human retinal imaging. The akinetic AML wavelength-swept fiber laser was constructed with polarization-maintaining fiber that has an average linewidth of 0.625 nm, a spectral bandwidth of 81.15 nm, and duty ratio of 90% without the buffering method. We successfully obtained in-vivo human retinal images using the proposed OCT system without the additional k-clock and the frequency shifter that provides a wide field of view of 43.1°. The main retina layers, such as the retinal pigment epithelium, can be distinguished from the OCT image with an axial resolution of 6.3 µm with this OCT system.


Assuntos
Retina/diagnóstico por imagem , Tomografia de Coerência Óptica/instrumentação , Algoritmos , Desenho de Equipamento , Humanos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Tomografia de Coerência Óptica/métodos
7.
Sci Rep ; 8(1): 4805, 2018 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-29556037

RESUMO

Tendons are tough, flexible, and ubiquitous tissues that connect muscle to bone. Tendon injuries are a common musculoskeletal injury, which affect 7% of all patients and are involved in up to 50% of sports-related injuries in the United States. Various imaging modalities are used to evaluate tendons, and both magnetic resonance imaging and sonography are used clinically to evaluate tendons with non-invasive and non-ionizing radiation. However, these modalities cannot provide 3-dimensional (3D) structural images and are limited by angle dependency. In addition, anisotropy is an artifact that is unique to the musculoskeletal system. Thus, great care should be taken during tendon imaging. The present study evaluated a functional photoacoustic microscopy system for in-vivo tendon imaging without labeling. Tendons have a higher density of type 1 collagen in a cross-linked triple-helical formation (65-80% dry-weight collagen and 1-2% elastin in a proteoglycan-water matrix) than other tissues, which provides clear endogenous absorption contrast in the near-infrared spectrum. Therefore, photoacoustic imaging with a high sensitivity to absorption contrast is a powerful tool for label-free imaging of tendons. A pulsed near-infrared fiber-based laser with a centered wavelength of 780 nm was used for the imaging, and this system successfully provided a 3D image of mouse tendons with a wide field of view (5 × 5 mm2).


Assuntos
Imageamento Tridimensional/métodos , Lasers , Microscopia/métodos , Técnicas Fotoacústicas/métodos , Tendões/anatomia & histologia , Animais , Colágeno/metabolismo , Processamento de Imagem Assistida por Computador , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Microscopia/instrumentação , Técnicas Fotoacústicas/instrumentação , Proteoglicanas/metabolismo , Tendões/metabolismo
8.
Meas Sci Technol ; 24(6): 65101, 2013 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-24489440

RESUMO

A novel linearized interrogation method is presented for a Fourier domain mode-locked (FDML) fiber Bragg grating (FBG) sensor system. In a high speed regime over several tens of kHz modulations, a sinusoidal wave is available to scan the center wavelength of an FDML wavelength-swept laser, instead of a conventional triangular wave. However, sinusoidal wave modulation suffers from an exaggerated non-uniform wavelength-spacing response in demodulating the time-encoded parameter to the absolute wavelength. In this work, the calibration signal from a polarization-maintaining fiber Sagnac interferometer shares the FDML wavelength-swept laser for FBG sensors to convert the time-encoded FBG signal to the wavelength-encoded uniform-spacing signal.