RESUMO
Tricuspid regurgitation (TR) can have a significant impact on the health and mortality of a patient. Unfortunately, many patients with advanced right-sided heart failure are not referred for isolated tricuspid valve (TV) surgery in a timely manner. This delayed referral has resulted in a high in-hospital mortality rate and significant undertreatment. Fortunately, transcatheter TV intervention (TTVI) has emerged as a safe and effective alternative to surgery, successfully reducing TR severity and improving patients' quality of life. Current guidelines emphasize the importance of assessing TR severity and its impact on the right heart chambers for selecting the appropriate intervention. However, the echocardiographic assessment of both right chambers and TV anatomy, along with TR severity, poses specific challenges, leading to the underestimation of TR severity. Recently, three-dimensional echocardiography has become crucial to enhance the characterization of TR severity. Moreover, it is essential to evaluate residual TR after TTVI to gauge the intervention's success and predict the patient's prognosis. This review provides a thorough evaluation of the echocardiographic parameters used to assess TR severity before and after TTVI. It presents a critical analysis of the accuracy and reliability of these parameters, highlighting their strengths and limitations to establish standardized diagnostic criteria and treatment protocols for TR, which will inform clinical decision-making and improve patient outcomes.
Assuntos
Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Ecocardiografia Tridimensional/métodos , Ecocardiografia/métodos , Cuidados Pré-Operatórios/métodos , Índice de Gravidade de Doença , Implante de Prótese de Valva Cardíaca/métodos , Reprodutibilidade dos TestesRESUMO
INTRODUCTION: Over the last two decades, mitral transcatheter edge-to-edge repair (M-TEER) has become a safe and effective therapy for severe mitral regurgitation in patients deemed at high surgical risk. AREAS COVERED: This review aims to encompass the most relevant and updated evidence in the field of M-TEER from its inception, focusing on clinical and anatomical features for proper patient and device selection. EXPERT OPINION: Growing operator experience and device iterations have resulted in improved clinical outcomes and an expansion of the therapy to patients with complex anatomies and clinical scenarios. Future investigations are warranted to determine the best management options and the most suitable device for every patient with MR.
Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Seleção de Pacientes , Insuficiência da Valva Mitral/cirurgia , Resultado do TratamentoRESUMO
Importance: Optimal antithrombotic therapy after percutaneous left atrial appendage occlusion (LAAO) is not well established as no randomized evaluation has been performed to date. Objective: To compare the efficacy and safety of low-dose direct oral anticoagulation (low-dose DOAC) vs dual antiplatelet therapy (DAPT) for 3 months after LAAO. Design, Setting, and Participants: The ADALA (Low-Dose Direct Oral Anticoagulation vs Dual Antiplatelet Therapy After Left Atrial Appendage Occlusion) study was an investigator-initiated, multicenter, prospective, open-label, randomized clinical trial enrolling participants from June 12, 2019, to August 28, 2022 from 3 European sites. Patients who underwent successful LAAO were randomly assigned 1:1 to low-dose DOAC vs DAPT for 3 months after LAAO. The study was prematurely terminated when only 60% of the estimated sample size had been included due to lower recruitment rate than anticipated due to the COVID-19 pandemic. Interventions: The low-dose DOAC group received apixaban, 2.5 mg every 12 hours, and the DAPT group received aspirin, 100 mg per day, plus clopidogrel, 75 mg per day, for the first 3 months after LAAO. Main Outcomes and Measures: The primary end point was a composite of safety (major bleeding) and efficacy (thromboembolic events including stroke, systemic embolism, and device-related thrombosis [DRT]) within the first 3 months after successful LAAO. Secondary end points included individual components of the primary outcome and all-bleeding events. Results: A total of 90 patients (mean [SD] age, 76.6 [8.1] years; 60 male [66.7%]; mean [SD] CHADS-VASc score, 4.0 [1.5]) were included in the analysis (44 and 46 patients in the low-dose DOAC and DAPT groups, respectively). A total of 53 patients (58.8%) presented with previous major bleeding events (60 gastrointestinal [66.7%] and 16 intracranial [17.8%]). At 3 months, low-dose DOAC was associated with a reduction of the primary end point compared with DAPT (2 [4.5%] vs 10 [21.7%]; hazard ratio, 0.19; 95% CI, 0.04-0.88; P = .02). Patients in the low-dose DOAC group exhibited a lower rate of DRT (0% vs 6 [8.7%]; P = .04) and tended to have a lower incidence of major bleeding events (2 [4.6%] vs 6 [13.0%]; P = .17), with no differences in thromboembolic events such as stroke and systemic embolism between groups (none in the overall population). Conclusions and Relevance: This was a small, randomized clinical trial comparing different antithrombotic strategies after LAAO. Results show that use of low-dose DOAC for 3 months after LAAO was associated with a better balance between efficacy and safety compared with DAPT. However, the results of the study should be interpreted with caution due to the limited sample size and will need to be confirmed in future larger randomized trials. Trial Registration: ClinicalTrials.gov Identifier: NCT05632445.
Assuntos
Aspirina , Apêndice Atrial , Fibrilação Atrial , Clopidogrel , Inibidores da Agregação Plaquetária , Humanos , Masculino , Apêndice Atrial/cirurgia , Feminino , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Inibidores da Agregação Plaquetária/administração & dosagem , Clopidogrel/administração & dosagem , Aspirina/administração & dosagem , Estudos Prospectivos , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Administração Oral , Terapia Antiplaquetária Dupla/métodos , Piridonas/administração & dosagem , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Idoso de 80 Anos ou mais , Pirazóis/administração & dosagem , Inibidores do Fator Xa/administração & dosagem , Anticoagulantes/administração & dosagem , Resultado do TratamentoRESUMO
INTRODUCTION: With the expanding indications of transcatheter aortic valve replacement (TAVR) to younger and low-risk patients, the life expectancy of patients currently undergoing TAVR will likely outlive the durability of transcatheter bioprosthesis. Consequently, the number of failed transcatheter bioprosthesis requiring surgical valve explant or redo TAVR is expected to increase. AREAS COVERED: The aim of this review is to provide an updated overview of redo TAVR for treating degenerated transcatheter bioprosthesis, focusing on pre-procedural planning, potential challenges of coronary reaccess during TAVR-in-TAVR and main outcomes of TAVR explant and redo TAVR. EXPERT OPINION: Patient-tailored device selection and individualized implantation height should be carefully assessed during the index TAVR procedure (weighting between pacemaker avoidance and the potential risk of coronary occlusion in future TAVR-in-TAVR). Future prospective studies comparing safety and clinical outcomes between redo TAVR vs TAVR explant are eagerly awaited.
Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Fatores de RiscoRESUMO
Transcatheter aortic valve replacement (TAVR) is currently the treatment of choice for patients aged ≥75 years with severe aortic stenosis. Preoperative anemia is present in a large proportion of patients and may increase the risk of post-procedural complications. The purpose of this prognostic systematic review was to analyze the impact of baseline anemia on short- and mid-term outcomes following TAVR. A computerized search was performed on PubMed and Web of Science databases for studies published between January 2013 and December 2022. Primary outcomes were 30-day need for transfusion, acute renal failure, 30-day and mid-term mortality, and readmission during the first year post-TAVR. Data were analyzed via random effects model using inverse variance method with 95% confidence intervals. Eleven observational studies met our eligibility criteria and included a total of 12,588 patients. The prevalence of baseline anemia ranged between 39% and 72%, with no relevant sex differences. Patients with preprocedural anemia received more blood transfusions [OR: 2.95 (2.13-4.09)]), and exhibited increased rates of acute kidney injury [OR:1.74 (1.45-2.10)], short-term mortality [OR: 1.47 (1.07-2.01], and mid-term [OR: 1.89 (1.58-2.25)] mortality following TAVR compared with those without anemia. Baseline anemia determined an increased risk for blood transfusion, acute kidney injury, and short/mid-term mortality among TAVR recipients.
RESUMO
INTRODUCTION AND OBJECTIVES: The cusp overlap technique (COT) has been proposed to reduce conduction disturbances (CD) after transcatheter aortic valve implantation (TAVI) with self-expanding supra-annular devices, but there are scarce data on COT with intra-annular valves. The aim of this study was to determine whether the use of the COT during Portico implantation results in higher valve implantation and lower rates of CD. METHODS: We included 85 patients undergoing TAVI with the Portico FlexNav system: 43 retrospective patients using the standard 3-cusp view and 42 prospective patients with the COT. Primary endpoints were implantation depth and new-onset CD (composite outcome of new-onset left bundle branch block and new permanent pacemaker implantation). RESULTS: COT resulted in a higher implantation depth (noncoronary cusp: 4.9±3.9 vs 7.4±3.0; P=.005) and lower new-onset CD (31.0% vs 58.1%; P=.012), with a tendency toward a lower need for permanent pacemaker implantation (14.3% vs 30.2%, P=.078; 7.7% vs 31.0%; P=.011 in patients without pre-existing right bundle branch block). Transvalvular aortic gradients were slightly lower with COT (8.7±3.7 vs 11.0±6.1; P=.044). There were no differences in technical success or major procedure-related complications. On multivariate analysis, COT use was associated with a lower risk of new-onset CD. CONCLUSIONS: Use of the COT during Portico implantation is feasible and facilitates a higher valve implant, which in turn may help to reduce rates of new-onset CD.
Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Estudos Prospectivos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Doença do Sistema de Condução Cardíaco , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgiaRESUMO
INTRODUCTION AND OBJECTIVES: The PASCAL system is a novel device for transcatheter mitral valve repair based on the edge-to-edge concept. The unique features of this device might have a relevant impact on the repair outcomes. There are few data on clinical outcomes in real-life registries. The aim of this study was to report the early Iberian experience (Spain and Portugal) of the PASCAL system. METHODS: Procedural and 30-day outcomes were investigated in consecutive patients with symptomatic severe mitral regurgitation (MR) treated with the PASCAL system at 10 centers. Primary efficacy endpoints were technical success and degree of residual MR at discharge. The primary safety endpoint was the rate of major adverse events (MAE) at 30 days. RESULTS: We included 68 patients (age, 75 [68-81] years; 38% women; EuroSCORE II 4.5%). MR etiology was degenerative in 25%, functional in 65%, and mixed in 10%. A total of 71% of patients were in New York Heart Association (NYHA) functional class≥III. Technical success was achieved in 96% and independent capture was used in 73% of procedures. In the treated population, MR at discharge was≤2+ in 100%, with no in-hospital deaths. At 30 days, the MAE rate was 5.9%, the all-cause mortality rate was 1.6%, 98% were in NYHA functional class≤II, and 95% had MR≤2+ (P<.001). CONCLUSIONS: Transcatheter mitral valve repair with the PASCAL system was safe and effective, with high procedural success and low rates of MAE. At 30 days, MR was significantly reduced, with a significant improvement in functional status.
Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Feminino , Idoso , Masculino , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/efeitos adversos , Resultado do TratamentoRESUMO
An 80-year-old woman with mitral valve repair failure was admitted with hemolytic anemia secondary to the impact of a regurgitant jet on the annuloplasty ring. Transcatheter repair to treat both mitral regurgitation and hemolysis was favored because of surgical risk. Transcatheter edge-to-edge repair represents an alternative for treating hemolysis associated with mitral regurgitation. (Level of Difficulty: Advanced.).