Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Endocr Pract ; 30(3): 239-245, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38122932

RESUMO

OBJECTIVE: To investigate the usefulness of ultrasound (US) for the localization of ectopic hyperparathyroidism and compare it with 99mTc-sestamibi (99mTc-MIBI), 4-dimensional computed tomography (4D-CT), and 11C-choline positron emission tomography/ computed tomography (PET/CT). METHODS: Of the 527 patients with surgically confirmed primary hyperparathyroidism, 79 patients with ectopic hyperparathyroidism were enrolled. The diagnostic performance of US, 99mTc-MIBI, US + MIBI, 4D-CT, and 11C-choline PET/CT was calculated, and the factors affecting the sensitivity of US and 99mTc-MIBI were analyzed. RESULTS: Eighty-three ectopic parathyroid lesions were found in 79 patients. The sensitivity was 75.9%, 81.7%, 95.1%, 83.3%, and 100% for US, 99mTc-MIBI, US + MIBI, 4D-CT, and 11C-choline PET/CT, respectively. The difference in sensitivity among these different modalities did not achieve statistical significance (P > .05). The US sensitivity was significantly higher for ectopic lesions in the neck region than for those in the anterior mediastinum/chest wall (85.9% vs. 42.1%, P < .001). The 99mTc-MIBI and 4D-CT sensitivity was not significantly different between these two groups (84.1% vs. 94.6%, P = .193 and 81.3% vs. 85.7%, P = 1). The 11C-choline PET/CT sensitivity was 100% in both groups. CONCLUSIONS: US is a valuable tool for the localization of ectopic hyperparathyroidism, especially for ectopic lesions in the neck region.


Assuntos
Hiperparatireoidismo Primário , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia Computadorizada Quadridimensional/métodos , Hiperparatireoidismo Primário/diagnóstico por imagem , Colina , Tecnécio Tc 99m Sestamibi , Glândulas Paratireoides/diagnóstico por imagem , Compostos Radiofarmacêuticos
2.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 45(1): 57-63, 2023 Feb.
Artigo em Zh | MEDLINE | ID: mdl-36861156

RESUMO

Objective To evaluate the performance of contrast-enhanced ultrasound (CEUS) liver imaging reporting and data system (LI-RADS) LR-5 in the diagnosis of hepatocellular carcinoma (HCC). Methods The clinical research reports with the application of CEUS LI-RADS in the diagnosis of HCC were collected from PubMed,Embase,Cochrane Library,CNKI,and Wanfang Data from inception to November 14,2021.Two researchers respectively screened the literature and extracted relevant information.The Quality Assessment of Diagnostic Accuracy Studies (QUADAS) was used to evaluate the quality of all the included articles.RevMan 5.4,Meta disc 1.4,and Stata 16.0 were employed to analyze the diagnostic performance of LR-5 for HCC in high-risk patients. Results Twenty original studies were included,involving a total of 6131 lesions,of which 5142 were HCC.The results of meta-analysis showed that the LR-5 in CEUS LI-RADS for diagnosing HCC in the high-risk population had the overall sensitivity of 0.72 (95%CI=0.66-0.77),the overall specificity of 0.93 (95%CI=0.87-0.96),the overall positive likelihood ratio of 9.89 (95%CI=5.31-18.41),the overall negative likelihood ratio of 0.30 (95%CI=0.25-0.37),and the area under the summary receiver operating characteristic curve of 0.88 (95%CI=0.85-0.91).There was heterogeneity among the included studies (I2=95.31,P<0.001).The funnel plot indicated the existence of publication bias (P=0.04). Conclusion The CEUS LI-RADS can effectively diagnose HCC in high-risk patients based on the LR-5 criteria.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Diagnóstico por Imagem , Ultrassonografia
3.
Eur Radiol ; 32(12): 8485-8496, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35699767

RESUMO

OBJECTIVES: To explore the diagnostic performance of EFSUMB CEUS Pancreatic Applications guidelines (version 2017) before and after the addition of iso-enhancement and very fast/fast washout as supplementary diagnostic criteria for PDAC. METHODS: In this retrospective study, patients diagnosed with solid pancreatic lesions from January 2017 to December 2020 were evaluated. Pancreatic ductal adenocarcinoma (PDAC) is reported to show hypo-enhancement in all phases according to the EFSUMB guidelines. First, based on this definition, all lesions were categorized as PDAC and non-PDAC. Then, iso-enhancement and very fast/fast washout were added as supplementary diagnostic criteria, and all lesions were recategorized. The diagnostic performance was assessed in terms of the accuracy (ACC), sensitivity (SEN), specificity (SPE), positive predictive value (PPV), and negative predictive value (NPV). The reference standard consisted of histologic evaluation or composite imaging and clinical follow-up findings. RESULTS: A total of 455 nodules in 450 patients (median age, 58.37 years; 250 men) were included. The diagnostic performance using the EFSUMB CEUS guidelines for PDAC had an ACC of 69.5%, SEN of 65.4%, SPE of 84%, PPV of 93.5%, NPV of 40.6%, and ROC of 0.747. After recategorization according to the supplementary diagnostic criteria, the diagnostic performance for PDAC had an ACC of 95.8%, SEN of 99.2%, SPE of 84%, PPV of 95.7%, NPV of 96.6%, and ROC of 0.916. CONCLUSION: The EFSUMB guidelines and recommendations for pancreatic lesions can effectively identify PDAC via hypo-enhancement on CEUS. However, the diagnostic performance may be further improved by the reclassification of PDAC lesions after adding iso-enhancement and very fast/fast washout mode. KEY POINTS: • In the EFSUMB guidelines, the only diagnostic criterion for PDAC is hypo-enhancement, to which iso-enhancement and very fast/fast washout mode were added in our research. • Using hypo-enhancement/iso-enhancement with very fast/fast washout patterns as the diagnostic criteria for PDAC for solid pancreatic masses on CEUS has high diagnostic accuracy. • The blood supply pattern of PDAC can provide important information, and CEUS has unique advantages in this respect due to its real-time dynamic attenuation ability.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Masculino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Meios de Contraste/farmacologia , Ultrassonografia/métodos , Pâncreas , Neoplasias Pancreáticas/diagnóstico por imagem , Sensibilidade e Especificidade , Diagnóstico Diferencial , Neoplasias Pancreáticas
4.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 44(1): 118-122, 2022 Feb.
Artigo em Zh | MEDLINE | ID: mdl-35300773

RESUMO

BR55 is an ultrasound contrast agent targeting vascular endothelial growth factor receptor 2,which can be used to detect tumor neovascularization and improve the diagnostic accuracy.Overseas researchers have used BR55 for human ultrasound molecular imaging,which showed good safety and tolerance.We reviewed the research progress on BR55 applied in the evaluation of tumor neovascularization from the composition,characteristics,animal experiments,and clinical studies of BR55.


Assuntos
Meios de Contraste , Imagem Molecular , Neovascularização Patológica , Receptor 2 de Fatores de Crescimento do Endotélio Vascular , Animais , Humanos , Microbolhas , Imagem Molecular/métodos , Neovascularização Patológica/diagnóstico por imagem , Ultrassonografia/métodos , Receptor 2 de Fatores de Crescimento do Endotélio Vascular/análise
5.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 40(3): 378-384, 2018 Jun 28.
Artigo em Zh | MEDLINE | ID: mdl-29978796

RESUMO

Objective To investigate the role of 17-MHz high-frequency linear array probe in detecting the microcalcification of papillary thyroid carcinoma (PTC) and its pathological basis. Methods The clinical data of 75 patients with PTC diagnosed by ultrasonography and pathology in China-Japan Friendship Hospital from January 2016 to January 2017 were analyzed. The detection rate of microcalcification was compared between 17-MHz high-frequency ultrasound and conventional ultrasound,and the imaging findings and pathological Results were analyzed. Results Among 93 thyroid nodules,the detection rate of PTC microcalcification by 17-MHz ultrasound was 74.2% (69/93),which was significantly higher than that of conventional ultrasound (59.1%,55/93) (χ2=4.742,P=0.029). The diagnostic sensitivity,specificity,accuracy,positive predictive value,and negative predictive value of the conventional ultrasound and the 17-MHz ultrasound were 73.6% and 98.1%,60.0% and 57.5%,67.7% and 80.6%,70.9% and 75.4%,and 63.1% and 95.8%,respectively. Pathology confirmed the presence of microcalcification at 53 nodules,among which psammoma bodies were found in 10 nodules;in addition,all the psammoma bodies were located in the cell mass,whereas irregular calcium deposits were mainly in proliferated fibrous tissues. Conclusion sThe 17-MHz high-frequency ultrasound can increase the detection rate of microcalcification in thyroid nodules. The ultrasonic manifestations of microcalcification do not completely correspond to the psammoma bodies found in pathology;rather,they may represent the irregular calcium deposits on fibrous tissues.


Assuntos
Calcinose/diagnóstico por imagem , Câncer Papilífero da Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Ultrassonografia , Humanos , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Nódulo da Glândula Tireoide/diagnóstico por imagem
6.
J Ultrasound Med ; 36(7): 1329-1337, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28463412

RESUMO

OBJECTIVES: To evaluate whether Superb Micro-Vascular Imaging (SMI; Toshiba Medical Systems Corporation, Tochigi, Japan) is superior to power Doppler flow imaging (PDFI) in depicting thyroid nodular vascularity and to primarily explore the diagnostic performance of vascularity on SMI integrated with grayscale sonographic features for diagnosis of malignant thyroid nodules. METHODS: Ninety-two resident patients with 113 nodules for surgery were included in the study. Thirty-four nodules were benign, and 79 nodules were malignant. Vascularity was classified as none, peripheral, mixed, and intranodular. Grayscale features, including calcifications, echogenicity, margins, shape, and internal components, were evaluated. The distribution of vascular patterns was compared between PDFI and SMI to determine the superior technique for diagnosing malignancy. A multivariate logistic regression analysis was used to evaluate the accuracy of SMI combined with grayscale sonography for thyroid malignancy. RESULTS: The 92 patients had a male-to-female ratio of 12:11 and a median age of 42 years (range, 20-75 years). Intranodular vascularity on SMI had 91.2% specificity and 75.9% sensitivity, which were superior to PDFI, at 82.3% and 41.8%, respectively (P < .01). We attribute this finding to the fact that peripheral vessels of many nodules on PDFI were actually intense small penetrating vessels around the lesion on SMI. A taller-than-wide shape, microcalcifications, and SMI intranodular vascularity were independent risk factors for thyroid malignancy. The area under the receiver operating characteristic curve for the logistic regression model was 0.92, which was higher than that for a single suspicious sonographic feature (P < .05). CONCLUSIONS: Intranodular vascularity on SMI is useful for determining thyroid carcinoma. Furthermore, a combination of SMI and grayscale features performs better than any single sonographic feature alone.


Assuntos
Ecocardiografia Doppler em Cores/métodos , Aumento da Imagem/métodos , Microvasos/diagnóstico por imagem , Neovascularização Patológica/diagnóstico por imagem , Cuidados Pré-Operatórios/métodos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neovascularização Patológica/complicações , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Nódulo da Glândula Tireoide/complicações , Nódulo da Glândula Tireoide/cirurgia
7.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 39(5): 682-687, 2017 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-29125112

RESUMO

Objective To investigate the clinical values of combined diffused optical tomography (DOT) combined positron emission tomography-computed tomography (PET-CT) in the diagnosis of breast cancer. Methods We performed DOT and PET-CT examinations in 38 patients with 40 lesions and compared these images with the pathological results to analyze the sensitivity,specificity,accuracy,positive predictive value,and negative predictive value of these two techniques and their combination.Results The sensitivity,specificity,accuracy,positive predictive value,and negative predictive value in diagnosing breast cancer were 78.26%,76.47%,77.50%,72.22%,and 81.81% for DOT,86.96%,82.35%,85.00%,86.96%,and 82.35% for PET-CT,and 86.96%,94.12%,90.00%,95.23%,and 84.21% for the combination of PET-CT and DOT.Conclusions DOT and PET-CT are both effective diagnostic methods for breast cancer.Combined DOT and PET-CT can improve the diagnostic efficacy in terms of specificity,positive predictive value,and accuracy.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia Óptica , Feminino , Fluordesoxiglucose F18 , Humanos , Valor Preditivo dos Testes , Sensibilidade e Especificidade
8.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 37(4): 424-9, 2015 Aug.
Artigo em Zh | MEDLINE | ID: mdl-26564459

RESUMO

OBJECTIVE: To investigate the value of ultrasound in the diagnosis of pseudomyxoma peritonei (PMP) and summarize the ultrasonographic features of PMP by comparing with computed tomography (CT) findings. METHOD: Ultrasound and CT scan results of 25 patients with PMP confirmed by pathology after surgery were analyzed retrospectively. RESULTS: Among these 25 PMP patients,three were diagnosed by ultrasound and six by CT(P=0.579). The specific ultrasonographic features of PMP were as follows:the dense punctuate echoes or floccules were detected in hydrops abdominis,which seldom or never move with the change of body position. Honeycomb-like lesions were typical. Notches were formed on the surface of liver or spleen due to the mucinous material and/or the mucinous lesions. CONCLUSIONS: Both ultrasound and CT scan have poor detection rate in the diagnosis of PMP. PMP has specific ultrasonographic features,which may make it possible to diagnose most PMP lesions by ultrasound before surgery


Assuntos
Neoplasias Peritoneais , Pseudomixoma Peritoneal/diagnóstico por imagem , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Ultrassonografia
9.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 37(3): 309-14, 2015 06.
Artigo em Inglês | MEDLINE | ID: mdl-26149143

RESUMO

OBJECTIVE: To investigate the sonographic features of struma ovarii and its corresponding histopathologic findings. METHODS: The sonographic and histopathological features of 72 patients with histopathologically comfirmed struma ovarii who were treated in Peking Union Medical College Hospital from January 2005 to December 2014 were retrospectively reviewed. RESULTS: Of these 72 patients,71 had benign struma ovarii(73 lesions)and one patient had malignant struma ovarii(1 lesion). On ultrasonography,all the 73 benign lesions had distinct margin,45(61.6%)had multilocular cystic or cystic-solid mass,49(67.1%)had irregular shape,and 28(38.4%)had nodular solid protrusions in the cystic areas. On the color Doppler flow imaging,36(49.3%)lesions had blood flow signals. The ultrasonographic features of the malignant struma ovarii lesion were multilocular cystic-solid mass with several nodular solid protrusions in the cysic areas;on the color Doppler flow imaging,blood flow signals were visible within septa and solid areas. CONCLUSIONS: The sonographic features of struma ovarii are diverse. If ultrasonography reveals multilocular cystic or cystic-solid mass with distinct margin and isoechoic or hyperechoic nodular solid protrusions in the cystic areas with visible blood flow signals,the diagnosis of struma ovarii should be considered.


Assuntos
Estruma Ovariano/diagnóstico por imagem , Estruma Ovariano/patologia , Carcinoma Epitelial do Ovário , Humanos , Neoplasias Epiteliais e Glandulares , Neoplasias Ovarianas , Estudos Retrospectivos , Ultrassonografia
10.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 37(3): 305-8, 2015 06.
Artigo em Inglês | MEDLINE | ID: mdl-26149142

RESUMO

OBJECTIVE: To compare the size of papillary thyroid carcinoma on ultrasonography(US)and the actual size measured during histological examination and to discuss the potential causes of such discrepancy. METHODS: A total of 148 patients with histologically confirmed papillary thyroid carcinoma underwent thyroid surgery in our center from December 2012 to May 2013. Patients were stratified based on the size,morphology,margin,cystic component,and presence of Hashimoto's disease to compare the discrepancy of the US and pathalogical measurements. RESULTS: The mean sizes of the nodules measured by US and pathology were(1.58±0.94)cm and(1.33±0.84)cm,respectively(P=0.000). In 70.9%(105/148)of the nodules,the sizes measured by US were larger than those measured by pathology. In 17.6%(26/148)of the nodules,the sizes measured by US were smaller than those measured by pathology. In 1.1-1.4 cm size subgroup,the difference between mean ultrasound diameter and pathologic diameter was not significant [(1.21±0.11)cm vs.(1.11±0.32)cm,P=0.062]. In 0.1-1.0 cm size subgroup,the mean sizes of the nodules measured by US and pathology were(0.75±0.19)cm and(0.62±0.23)cm,respectively(P=0.000). In ≥1.5 cm size subgroup,the mean sizes of the nodules measured by US and pathology were(2.48±0.70)cm and(2.03±0.81)cm(P=0.000). CONCLUSIONS: There is a significant discrepancy between US and pathologic size measurements for papillary thyroid carcinoma. However,for nodules sized 1.1-1.4 cm,the ultrasound and pathologic measurements are more likely to be consistent.


Assuntos
Carcinoma/diagnóstico por imagem , Carcinoma/patologia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia , Carcinoma Papilar , Doença de Hashimoto , Humanos , Câncer Papilífero da Tireoide , Ultrassonografia
11.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 37(6): 656-61, 2015 Dec.
Artigo em Zh | MEDLINE | ID: mdl-26725388

RESUMO

OBJECTIVE: To investigate the correlation of contrast-enhanced pattern with expression of hypoxia inducible factor-1α (HIF-1α) and microvessel density (MVD) in mice breast cancer. METHODS: A total of 22 mice were implanted with breast cancer cells (Ca761) subcutanously in the thigh. The tumors were examined with conventional ultrasound and contrast-enhanced ultrasound (CEUS) on days 4,6,7,8,9,10,and 11 after implantation and then sacrificed. Three or four mice were included each time. Expressions of HIF-1α and MVD in cancer tissues were detected immunohistochemically. Correlation of contrast-enhanced patterns with expression of HIF-1α and MVD in breast cancer was analyzed. RESULTS: Mice were divided into 3 groups according to the tumor volume:group 1 (volume<0.05 cm(3),n=5),group 2 (volume 0.05-0.75 cm(3),n=9),and group 3 (volume>0.75 cm(3),n=8). The CEUS pattern was different in different groups:four mice in group 1 presented as type 1 (peripheral ring enhancement with no enhancement within the tumor) and 1 case presented as type 2 (peripheral ring enhancement with deep penetration). Most mice in group 2 presented as type 3 (homogeneous or heterogeneous enhancement in the whole tumor,n=5). In group 3,most mice presented as type 4 (peripheral ring enhancement with focal nodular enhancement within the tumor,n=7). Contrast-enhanced pattern was significantly different in different volume groups (P<0.01). Enhanced pattern (type 1-4) was closely correlated with tumor volume (r=0.841,P<0.05). The expression of HIF-1α was negatively correlated with enhanced patterns (type 1-4) (r=-0.596,P=0.003),but not with tumor volume (P>0.05). There was no significant difference in MVD values between different enhanced patterns (type 1-4),and there was no correlation between the MVD and tumor volumes (P>0.05). CONCLUSION: CEUS can be used as a noninvasive tool to monitor tumor angiogenesis in tumor and the enhanced patterns may reflect the expression of HIF-1α inside the tumor.


Assuntos
Neoplasias da Mama , Animais , Linhagem Celular Tumoral , Meios de Contraste , Subunidade alfa do Fator 1 Induzível por Hipóxia , Camundongos
12.
Sci Rep ; 14(1): 11768, 2024 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-38782971

RESUMO

Accurate selection of sampling positions is critical in renal artery ultrasound examinations, and the potential of utilizing deep learning (DL) for assisting in this selection has not been previously evaluated. This study aimed to evaluate the effectiveness of DL object detection technology applied to color Doppler sonography (CDS) images in assisting sampling position selection. A total of 2004 patients who underwent renal artery ultrasound examinations were included in the study. CDS images from these patients were categorized into four groups based on the scanning position: abdominal aorta (AO), normal renal artery (NRA), renal artery stenosis (RAS), and intrarenal interlobular artery (IRA). Seven object detection models, including three two-stage models (Faster R-CNN, Cascade R-CNN, and Double Head R-CNN) and four one-stage models (RetinaNet, YOLOv3, FoveaBox, and Deformable DETR), were trained to predict the sampling position, and their predictive accuracies were compared. The Double Head R-CNN model exhibited significantly higher average accuracies on both parameter optimization and validation datasets (89.3 ± 0.6% and 88.5 ± 0.3%, respectively) compared to other methods. On clinical validation data, the predictive accuracies of the Double Head R-CNN model for all four types of images were significantly higher than those of the other methods. The DL object detection model shows promise in assisting inexperienced physicians in improving the accuracy of sampling position selection during renal artery ultrasound examinations.


Assuntos
Aprendizado Profundo , Obstrução da Artéria Renal , Artéria Renal , Ultrassonografia Doppler em Cores , Humanos , Artéria Renal/diagnóstico por imagem , Ultrassonografia Doppler em Cores/métodos , Feminino , Masculino , Obstrução da Artéria Renal/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Adulto
13.
Ultrasound Med Biol ; 50(7): 1020-1027, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38594125

RESUMO

OBJECTIVE: This study aimed to investigate the impact of microbubble degradation and flow velocity on Sub-Harmonic Aided Pressure Estimation (SHAPE), and to explore the correlation between subharmonic amplitude and pressure as a single factor. METHODS: We develop an open-loop vascular phantom platform system and utilize a commercial ultrasound machine and microbubbles for subharmonic imaging. Subharmonic amplitude was measured continuously at constant pressure and flow velocity to assess the impact of microbubble degradation. Flow velocity was varied within a range of 4-14 cm/s at constant pressure to investigate its relationship to subharmonic amplitude. Furthermore, pressure was varied within a range of 10-110 mm Hg at constant flow velocity to assess its isolated effect on subharmonic amplitude. RESULTS: Under constant pressure and flow velocity, subharmonic amplitude exhibited a continuous decrease at an average rate of 0.221 dB/min, signifying ongoing microbubble degradation during the experimental procedures. Subharmonic amplitude demonstrated a positive correlation with flow velocity, with a variation ratio of 0.423 dB/(cm/s). Under controlled conditions of microbubble degradation and flow velocity, a strong negative linear correlation was observed between pressure and subharmonic amplitude across different Mechanical Index (MI) settings (all R2 > 0.90). The sensitivity of SHAPE was determined to be 0.025 dB/mmHg at an MI of 0.04. CONCLUSION: The assessment of SHAPE sensitivity is affected by microbubble degradation and flow velocity. Excluding the aforementioned influencing factors, a strong linear negative correlation between pressure and subharmonic amplitude was still evident, albeit with a sensitivity coefficient lower than previously reported values.


Assuntos
Microbolhas , Imagens de Fantasmas , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão , Ultrassonografia/métodos , Meios de Contraste
14.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 35(1): 69-73, 2013 Feb.
Artigo em Zh | MEDLINE | ID: mdl-23469794

RESUMO

OBJECTIVE: To explore the sonographic characteristics of intraveous leiomyomatosis (IVL) with intracardiac extension and improve its diagnosis. METHODS: The clinical and sonographic data of 13 female patients with pathologically confirmed IVL with intracardiac extension who were treated in our hospital between 2002 and 2012 were retrospectively analyzed. These patients aged 44 years old (range: 38-49 years), and 10 of them were first-episode patients and the remaining 3 were recurrent patients. Eight patients had a history of hysterectomy for leiomyoma. RESULTS: The first-episode symptoms included exertional chest tightness and shortness of breath (n=5), abdominal distention and edema of low extermity (n=4), exertional palpitation of cardiac origin (n=3), and menorrhagia (n=1). Ultrasonography showed that all patients had isoechoic or hypoechoic tumors extended through the inferior vena cava into right heart chambers (62% in right atrium alone and 38% in right ventricle and atrium). Nine masses in right heart chamber (69.2%) were oval and 4 (30.8%) were serpentine, which were all with well-demarcated borders and most (80%) with heteroechogenic texture. Ten patients had hypoechoic or mixed echoic tumors in pelvic cavity or uterus, and 6 of them had abundant blood flow. CONCLUSIONS: IVL with intracardiac extension has certain sonographic characteristics. Ultrasonography is a valuable tool in the diagnosis of IVL with intracardiac extension.


Assuntos
Leiomiomatose/diagnóstico por imagem , Miocárdio/patologia , Neoplasias Vasculares/diagnóstico por imagem , Adulto , Feminino , Humanos , Leiomiomatose/patologia , Pessoa de Meia-Idade , Estudos Retrospectivos , Ultrassonografia , Neoplasias Vasculares/patologia
15.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 35(2): 140-4, 2013 Apr.
Artigo em Zh | MEDLINE | ID: mdl-23643000

RESUMO

OBJECTIVE: To summarize the sonographic features of the lymphoma in the abdominal lymph nodes. METHOD: The clinical data and sonographic findings of 41 lymphoma patients with original appearance of abdominal mass or lymphadenectasis were retrospectively analyzed. RESULTS: Among these 41 cases, the retroperitoneal and mesenteric lymph nodes were most commonly involved.These patients were divided into two types according to sonographic appearances:solitary mass(n=14) and multiple nodules(n=27) .Solitary hypoechoic mass in abdomen was found in the former type, mostly with irregular or lobular shape, and the inner echo was often heterogenous.The typical appearances of the latter type were multiple enlarged lymph nodes, mostly round or oval, with homogeneous inner echo and clear margins.Some other sonographic characteristics were also helpful for the diagnosis of lymphoma, such as cobblestone sign, intranodular reticulation, vessels-embedded sign, and hilar vascularity. CONCLUSION: Ultrasonography can provide useful information in the diagnosis of the lymphoma in the abdominal lymph nodes.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Linfonodos/diagnóstico por imagem , Linfoma/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Ultrassonografia , Adulto Jovem
16.
Asia Pac J Clin Oncol ; 19(2): e71-e79, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35593663

RESUMO

RATIONALE AND OBJECTIVES: We aim to assess the performance of the Gail model and the fifth edition of ultrasound BI-RADS (Breast Imaging Reporting and Data System) in breast cancer for predicting axillary lymph node metastasis (ALNM). MATERIALS AND METHODS: We prospectively studied 958 female patients with breast cancer between 2018 and 2019 from 35 hospitals in China. Based on B-mode, color Doppler, and elastography, radiologists classified the degree of suspicion based on the fifth edition of BI-RADS. Individual breast cancer risk was assessed with the Gail model. The association between the US BI-RADS category and the Gail model in terms of ALNM was analyzed. RESULTS: We found that US BI-RADS category was significantly and independently associated with ALNM (P < 0.001). The sensitivity, specificity, and accuracy of BI-RADS category 5 for predicting ALNM were 63.6%, 71.6%, and 68.6%, respectively. Combining the Gail model with the BI-RADS category showed a significantly higher sensitivity than using the BI-RADS category alone (67.8% vs. 63.6%, P < 0.001). The diagnostic accuracy of the BI-RADS category combined with the Gail model was better than that of the Gail model alone (area under the curve: 0.71 vs. 0.50, P < 0.001). CONCLUSION: Based on the conventional ultrasound and elastography, the fifth edition of ultrasound BI-RADS category could be used to predict the ALNM of breast cancer. ALNM was likely to occur in patients with BI-RADS category 5. The Gail model could improve the diagnostic sensitivity of the US BI-RADS category for predicting ALNM in breast cancer.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Estudos Prospectivos , Ultrassonografia Mamária/métodos , Metástase Linfática/diagnóstico por imagem , Sensibilidade e Especificidade
17.
Quant Imaging Med Surg ; 13(6): 3902-3914, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37284072

RESUMO

Background: Contrast-enhanced ultrasound (CEUS) has proven valuable in diagnosing benign and malignant pancreatic diseases, but its value in evaluating hepatic metastasis remains to be further explored. This study investigated the relationship between CEUS features of pancreatic ductal adenocarcinoma (PDAC) and concomitant or recurrent liver metastases after treatment. Methods: This retrospective study included 133 participants with PDAC who were diagnosed with pancreatic lesions with CEUS at Peking Union Medical College Hospital from January 2017 to November 2020. According to the CEUS classification methods in our center, all the pancreatic lesions were classified as either with rich or poor blood supply. Additionally, quantitative ultrasonographic parameters were measured in the center and periphery of all pancreatic lesions. CEUS modes and parameters of the different hepatic metastasis groups were compared. The diagnostic performance of CEUS was calculated for diagnosing synchronous and metachronous hepatic metastasis. Results: The proportions of rich blood supply and poor blood supply were 46% (32/69) and 54% (37/69), respectively, in the no hepatic metastasis group; 42% (14/33) and 58% (19/33), respectively, in the metachronous hepatic metastasis (MHM) group; and 19% (6/31) and 81% (25/31), respectively, in the synchronous hepatic metastasis (SHM) group. The wash-in slope ratio (WIS ratio) between the center of the lesion and around the lesion and peak intensity ratio (PI ratio) between the center of the lesion and around the lesion had higher values in the negative hepatic metastasis group (P<0.05). In predicting synchronous and metachronous hepatic metastasis, the WIS ratio had the best diagnostic performance. The sensitivity (SEN), specificity (SPE), accuracy (ACC), positive predictive value (PPV), and negative predictive value (NPV) were 81.8%, 95.7%, 91.2%, 90.0%, and 91.7%, respectively, for MHM; and 87.1%, 95.7%, 93.0%, 90.0%, and 94.3%, respectively, for SHM. Conclusions: CEUS would be helpful in image surveillance for synchronous or metachronous hepatic metastasis of PDAC.

18.
J Ultrasound Med ; 31(5): 747-55, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22535722

RESUMO

OBJECTIVES: The purpose of this study was to investigate the influence of atherosclerosis and age on 4 representative Doppler parameters in the diagnosis of renal artery stenosis. METHODS: The 4 parameters, renal peak systolic velocity (PSV), renal-aortic ratio, renal-interlobar ratio, and acceleration time, were measured in 208 patients before angiography. The 208 patients were divided into groups according to age and atherosclerosis stratification. The Student t test, 1-way analysis of variance, and the χ(2) test were used to compare all 4 parameters and clinical characteristics. The optimal cutoff values were determined by receiver operating characteristic curves. The diagnostic concordance between atherosclerosis and age strata was evaluated by the Cohen κ coefficient. RESULTS: Of the 416 renal arteries shown on Doppler sonography, 204 had a diagnosis of renal artery stenosis and 19 as occlusion on angiography. The optimal cutoff values for the renal-aortic ratio and renal-interlobar ratio in the groups aged 46 years or older and younger than 46 years were much different (2.3 versus 1.4 and 5.1 versus 6.5, respectively), whereas those for the renal PSV and acceleration time were close to each other or the same (170 versus 180 cm/s and 51 versus 51 milliseconds). The κ coefficients for the renal PSV, renal-interlobar ratio, acceleration time, and renal-aortic ratio between the atherosclerosis and age strata were 0.93, 0.99, 1.00, and 0.71. CONCLUSIONS: Atherosclerosis and age show comparable influences on Doppler parameters in the diagnosis of renal artery stenosis. For clinical convenience, cutoff values may be separately established on the basis of a 46-year-old borderline for the renal-aortic ratio and renal-interlobar ratio, although this process is not necessary for the renal PSV and acceleration time.


Assuntos
Aterosclerose/complicações , Aterosclerose/diagnóstico por imagem , Obstrução da Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/etiologia , Ultrassonografia Doppler , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia , Área Sob a Curva , Distribuição de Qui-Quadrado , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC
19.
Front Oncol ; 12: 861151, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35387128

RESUMO

Background: To determine whether vascular index (VI; defined as the ratio of Doppler signal pixels to pixels in the total lesion) measured via superb microvascular imaging in breast cancer correlates with immunohistochemically defined subtype and is able to predict molecular subtypes. Methods: This prospective study involved 225 patients with 225 mass-type invasive breast cancers (mean size 2.6 ± 1.4 cm, range 0.4~5.9 cm) who underwent ultrasound and superb microvascular imaging (SMI) at Peking Union Medical College Hospital before breast surgery from December 2016 to June 2018. The correlations between primary tumor VI measured via SMI, clinicopathological findings, and molecular subtype were analyzed. The performance of VI for prediction of molecular subtypes in invasive breast cancer was investigated. Results: The median VI of the 225 tumors was 7.3% (4.2%~11.8%) (range 0%~54.4%). Among the subtypes of the 225 tumors, 41 (18.2%) were luminal A, 91 (40.4%) were luminal B human epidermal growth factor receptor-2 (HER-2)-negative, 26 (11.6%) were luminal B HER-2-positive, 17 (7.6%) were HER-2-positive, and 50 (22.2%) were triple-negative, and the corresponding median VI values were 5.9% (2.6%~11.6%) (range 0%~47.1%), 7.3 (4.4%~10.5%) (range 0%~29.5%), 6.3% (3.9%~11.3%) (range 0.6%~22.2%), 8.2% (4.9%~15.6%) (range 0.9%~54.4%), and 9.2% (5.1%~15.3%) (range 0.7%~32.9%), respectively. Estrogen receptor (ER) negativity, higher tumor grade, and higher Ki-67 index (≥20%) were significantly associated with a higher VI value. Tumor size, ER status, and Ki-67 index were shown to independently influence VI. A cutoff value of 4.1% yielded 79.9% sensitivity and 41.5% specificity with an area under the receiver operating characteristic curve (AUC) of 0.58 for predicting that a tumor was of the luminal A subtype. A cutoff value of 16.4% yielded 30.0% sensitivity and 90.3% specificity with an AUC of 0.60 for predicting a triple-negative subtype. Conclusions: VI, as a quantitative index obtained by SMI examination, could reflect histologic vascular changes in invasive breast cancer and was found to be higher in more biologically aggressive breast tumors. VI shows a certain degree of correlation with the molecular subtype of invasive breast cancer and plays a limited role in predicting the luminal A with high sensitivity and triple-negative subtype with high specificity.

20.
Acad Radiol ; 29 Suppl 1: S1-S7, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33384211

RESUMO

RATIONALE AND OBJECTIVES: The sonographic appearance of benign and malignant breast nodules overlaps to some extent, and we aimed to assess the performance of the Gail model as an adjunctive tool to ultrasound (US) Breast Imaging Reporting and Data System (BI-RADS) for predicting the malignancy of nodules. MATERIALS AND METHODS: From 2018 to 2019, 2607 patients were prospectively enrolled by 35 health care facilities. An individual breast cancer risk was assessed by the Gail model. Based on B-mode US, color Doppler, and elastography, all nodules were evaluated according to the fifth edition of BI-RADS, and these nodules were all confirmed later by pathology. RESULTS: We demonstrated that the Gail model, age, tumor size, tumor shape, growth orientation, margin, contour, acoustic shadowing, microcalcification, presence of duct ectasia, presence of architectural distortion, color Doppler flow, BI-RADS, and elastography score were significantly related to breast cancer (all p < 0.001). The sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and area under the curve (AUC) for combining the Gail model with the BI-RADS category were 95.6%, 91.3%, 85.0%, 97.6%, 92.8%, and 0.98, respectively. Combining the Gail model with the BI-RADS showed better diagnostic efficiency than the BI-RADS and Gail model alone (AUC 0.98 vs 0.80, p < 0.001; AUC 0.98 vs 0.55, p < 0.001) and demonstrated a higher specificity than the BI-RADS (91.3% vs 59.4%, p < 0.001). CONCLUSION: The Gail model could be used to differentiate malignant and benign breast lesions. Combined with the BI-RADS category, the Gail model was adjunctive to US for predicting breast lesions for malignancy. For the diagnosis of malignancy, more attention should be paid to high-risk patients with breast lesions.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Diagnóstico Diferencial , Técnicas de Imagem por Elasticidade/métodos , Feminino , Humanos , Estudos Prospectivos , Sensibilidade e Especificidade , Ultrassonografia Mamária/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA