Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
ACS Sens ; 9(9): 4731-4739, 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39166952

RESUMO

Microwave gas sensors have garnered attention for their high sensitivity and selectivity in the detection of volatile organic compounds (VOCs). However, traditional gas sensors generally rely on sensitive materials that degrade over time and are easily affected by the environment, compromising their stability and accuracy. This study proposes a microwave VOC gas sensor based on the condensation effect. The sensor adopts a novel design without sensitive materials, utilizing the condensation effect to detect acetone gas. The sensor system consists of a microwave sensor and a temperature control device. As the sensor temperature is lowered below the boiling point of acetone, the condensation of acetone gas on the sensor surface is achieved, enabling accurate detection of acetone gas. Experimental results indicate that the accumulated amount of acetone on the sensor surface is positively correlated with its response, with the maximum response of 3000 ppm acetone gas reaching 0.34 dB. Additionally, this study investigated the detection mechanism of the sensor after adding the sensitive material MXene and compared the performance of the sensor at different temperatures (-10 °C, 0 °C, and 60 °C). The results show that at -10 °C the sensor mainly captures acetone through physical adsorption, while at 25 and 60 °C, it primarily responds through chemical adsorption, with a maximum response of 0.29 dB. The VOC sensor based on the condensation effect without sensitive materials not only achieves the same sensitivity as traditional microwave sensors but also demonstrates stronger stability and anti-interference capabilities.


Assuntos
Acetona , Gases , Micro-Ondas , Temperatura , Compostos Orgânicos Voláteis , Acetona/análise , Acetona/química , Compostos Orgânicos Voláteis/análise , Gases/análise , Gases/química
2.
ChemMedChem ; : e202400349, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38965060

RESUMO

Bacterial infection, which can trigger varieties of diseases and tens of thousands of deaths each year, poses serious threats to human health. Particularly, the new dilemma caused by biofilms is gradually becoming a severe and tough problem in the biomedical field. Thus, the strategies to address these problems are considered an urgent task at present. Micro/nanomotors (MNMs), also named micro/nanoscale robots, are mostly driven by chemical energy or external field, exhibiting strong diffusion and self-propulsion in the liquid media, which has the potential for antibacterial applications. In particular, when MNMs are assembled in swarms, they become robust and efficient for biofilm removal. However, there is a lack of comprehensive review discussing the progress in this aspect. Bearing it in mind and based on our own research experience in this regard, the studies on MNMs driven by different mechanisms orchestrated for antibacterial activity and biofilm removal are timely and concisely summarized and discussed in this work, aiming to show the advantages of MNMs brought to this field. In addition, an outlook was proposed, hoping to provide the fundamental guidance for future development in this area.

3.
Biosens Bioelectron ; 241: 115686, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37729810

RESUMO

Micro/nanomotors (MNMs) emerge as a vital candidate for biosensing due to its nano-size structure, high surface-to-area ratio, directional mobility, biocompatibility, and ease of functionalization, therefore being able to detect objects with high efficiency, precision, and selectivity. The driving mode, nanostructure, materials property, preparation technique, and biosensing applications have been thoroughly discussed in publications. To promote the MNMs-based biosensors from in vitro to in vivo, it is necessary to give a comprehensive discussion from the perspective of sensing performances enhancement. However, until now, there is few reviews dedicated to the systematic discussion on the multiple performance enhancement schemes and the current challenges of MNMs-based biosensors. Bearing it in mind and based on our research experience in this field, we summarized the enhancement methods for biosensing properties such as sensitivity, selectivity, detection time, biocompatibility, simplify system operation, and environmental availability. We hope that this review provides the readers with fundamental understanding on performance enhancement schemes for MNMs-based biosensors.

4.
ACS Sens ; 8(10): 3862-3872, 2023 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-37752695

RESUMO

In this work, a new type, highly sensitive, and reusable nanoplastics (NPs) microwave detection method is proposed, which can be used to rapidly analyze NPs with different surface charges and sizes. The effective dielectric constant of NPs varies according to the different concentrations, particle sizes, and surface charges of NPs in aqueous solution. The feasibility of the microwave method for differential-charged NPs detection is verified using a complementary split ring resonator sensor manufactured on a cost-effective printed circuit board, which shows a high sensitivity only for positively charged NPs (PS-NH2) detection. To achieve microwave detection of both positively and negatively charged NPs (PS-SO3H), a microscale spiral-coupled resonator sensing chip is manufactured through integrated passive technology, which demonstrates extremely low detection limits and high sensitivity for both PS-NH2 and PS-SO3H, with different concentrations, particle sizes, and charges. In addition, for NPs solution doped with methyl orange, the device can still perform stable measurements, overcoming the inability of traditional NPs molecular element determination and optical detection methods to detect NPs aqueous solution with organic matter doping and color presence. The proposed microwave detection method could also be extended to sensing detection for detecting other hazardous environmental substances.


Assuntos
Microplásticos , Micro-Ondas
5.
Micromachines (Basel) ; 13(1)2022 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-35056289

RESUMO

In this paper, a bandpass filter (BPF) was developed utilizing GaAs-based integrated passive device technology which comprises an asymmetrical spiral inductor and an interleaved array capacitor, possessing two tuning modes: coarse-tuning and fine-tuning. By altering the number of layers and radius of the GaAs substrate metal spheres, capacitance variation from 0.071 to 0.106 pF for coarse-tuning, and of 0.0015 pF for fine-tuning, can be achieved. Five air bridges were employed in the asymmetrical spiral inductor to save space, contributing to a compact chip area of 0.015λ0 × 0.018λ0. The BPF chip was installed on the printed circuit board artwork with Au bonding wire and attached to a die sink. Measured results demonstrate an insertion loss of 0.38 dB and a return loss of 21.5 dB at the center frequency of 2.147 GHz. Furthermore, under coarse-tuning mode, variation in the center frequency from 1.956 to 2.147 GHz and transmission zero frequency from 4.721 to 5.225 GHz can be achieved. Under fine-tuning mode, the minimum tuning value and the average tuning value of the proposed BPF can be accurate to 1.0 MHz and 4.7 MHz for the center frequency and 1.0 MHz and 12.8 MHz for the transmission zero frequency, respectively.

6.
Micromachines (Basel) ; 13(5)2022 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-35630251

RESUMO

The wearable device industry is on the rise, with technology applications ranging from wireless communication technologies to the Internet of Things. However, most of the wearable sensors currently on the market are expensive, rigid and bulky, leading to poor data accuracy and uncomfortable wearing experiences. Near-field communication sensors are low-cost, easy-to-manufacture wireless communication technologies that are widely used in many fields, especially in the field of wearable electronic devices. The integration of wireless communication devices and sensors exhibits tremendous potential for these wearable applications by endowing sensors with new features of wireless signal transferring and conferring radio frequency identification or near-field communication devices with a sensing function. Likewise, the development of new materials and intensive research promotes the next generation of ultra-light and soft wearable devices for healthcare. This review begins with an introduction to the different components of near-field communication, with particular emphasis on the antenna design part of near-field communication. We summarize recent advances in different wearable areas of near-field communication sensors, including structural design, material selection, and the state of the art of scenario-based development. The challenges and opportunities relating to wearable near-field communication sensors for healthcare are also discussed.

7.
ACS Appl Mater Interfaces ; 14(5): 7301-7310, 2022 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-35076218

RESUMO

The high moisture level of exhaled gases unavoidably limits the sensitivity of breath analysis via wearable bioelectronics. Inspired by pulmonary lobe expansion/contraction observed during respiration, a respiration-driven triboelectric sensor (RTS) was devised for simultaneous respiratory biomechanical monitoring and exhaled acetone concentration analysis. A tin oxide-doped polyethyleneimine membrane was devised to play a dual role as both a triboelectric layer and an acetone sensing material. The prepared RTS exhibited excellent ability in measuring respiratory flow rate (2-8 L/min) and breath frequency (0.33-0.8 Hz). Furthermore, the RTS presented good performance in biochemical acetone sensing (2-10 ppm range at high moisture levels), which was validated via finite element analysis. This work has led to the development of a novel real-time active respiratory monitoring system and strengthened triboelectric-chemisorption coupling sensing mechanism.


Assuntos
Acetona/análise , Testes Respiratórios/métodos , Taxa Respiratória/fisiologia , Testes Respiratórios/instrumentação , Eletrônica , Humanos , Nanoestruturas/química , Polietilenoimina/química , Reprodutibilidade dos Testes , Compostos de Estanho/química , Dispositivos Eletrônicos Vestíveis
8.
Biosensors (Basel) ; 11(12)2021 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-34940237

RESUMO

Due to the increasing number of diabetic patients, early monitoring of glucose levels is particularly important; therefore, glucose biosensors have attracted enormous attention from researchers. In this paper, we propose a glucose microwave biosensor based on RFID and achieve a non-contact measurement of the concentration of glucose solutions. The Reader is a complementary split-ring resonator (CSRR), and the Tag is comprised of a squared spiral capacitor (SSC). A polydimethylsiloxane microfluidic quantitative cavity with a volume of 1.56 µL is integrated on the Tag to ensure that the glucose solution can be accurately set to the sensitive area and fully contacted with the electromagnetic flux. Because the SSC exhibits different capacitances when it contacts glucose solutions of different concentrations, changing the resonant frequency of the CSRR, we can use the relationship to characterize the biosensing response. Measurement results show that bare CSRR and RFID-based biosensors have achieved sensitivities of 0.31 MHz/mg·dL-1 and 10.27 kHz/mg·dL-1, and detection limits of 13.79 mg/dL and 1.19 mg/dL, respectively, and both realize a response time of less than 1 s. Linear regression analysis of the abovementioned biosensors showed an excellent linear relationship. The proposed design provides a feasible solution for microwave biosensors aiming for the non-contact measurement of glucose concentration.


Assuntos
Técnicas Biossensoriais , Dispositivo de Identificação por Radiofrequência , Glucose/química , Humanos , Microfluídica , Micro-Ondas
9.
Biosensors (Basel) ; 11(12)2021 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-34940241

RESUMO

Here, we propose a glucose biosensor with the advantages of quantification, excellent linearity, temperature-calibration function, and real-time detection based on a resistor and capacitor, in which the resistor works as a temperature sensor and the capacitor works as a biosensor. The resistor has a symmetrical meandering type structure that increases the contact area, leading to variations in resistance and effective temperature monitoring of a glucose solution. The capacitor is designed with an intertwined structure that fully contacts the glucose solution, so that capacitance is sensitively varied, and high sensitivity monitoring can be realized. Moreover, a polydimethylsiloxane microfluidic channel is applied to achieve a fixed shape, a fixed point, and quantitative measurements, which can eliminate influences caused by fluidity, shape, and thickness of the glucose sample. The glucose solution in a temperature range of 25-100 °C is measured with variations of 0.2716 Ω/°C and a linearity response of 0.9993, ensuring that the capacitor sensor can have reference temperature information before detecting the glucose concentration, achieving the purpose of temperature calibration. The proposed capacitor-based biosensor demonstrates sensitivities of 0.413 nF/mg·dL-1, 0.048 nF/mg·dL-1, and 0.011 pF/mg·dL-1; linearity responses of 0.96039, 0.91547, and 0.97835; and response times less than 1 second, respectively, at DC, 1 kHz, and 1 MHz for a glucose solution with a concentration range of 25-1000 mg/dL.


Assuntos
Técnicas Biossensoriais , Glucose , Calibragem , Capacitância Elétrica , Temperatura
10.
Biosensors (Basel) ; 11(12)2021 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-34940265

RESUMO

In this study, we propose a high-performance resonator-based biosensor for mediator-free glucose identification. The biosensor is characterized by an air-bridge capacitor and fabricated via integrated passive device technology on gallium arsenide (GaAs) substrate. The exterior design of the structure is a spiral inductor with the air-bridge providing a sensitive surface, whereas the internal capacitor improves indicator performance. The sensing relies on repolarization and rearrangement of surface molecules, which are excited by the dropped sample at the microcosmic level, and the resonance performance variation corresponds to the difference in glucose concentration at the macroscopic level. The air-bridge capacitor in the modeled RLC circuit serves as a bio-recognition element to glucose concentration (εglucoseC0), generating resonant frequency shifts at 0.874 GHz and 1.244 GHz for concentrations of 25 mg/dL and 300 mg/dL compared to DI water, respectively. The proposed biosensor exhibits excellent sensitivity at 1.38 MHz per mg/dL with a wide detection range for glucose concentrations of 25-300 mg/dL and a low detection limit of 24.59 mg/dL. Additionally, the frequency shift and concentration are highly linear with a coefficient of determination of 0.98823. The response time is less than 3 s. We performed multiple experiments to verify that the surface morphology reveals no deterioration and chemical binding, thus validating the reusability and reliability of the proposed biosensor.


Assuntos
Técnicas Biossensoriais , Glucose , Micro-Ondas , Reprodutibilidade dos Testes , Tecnologia
11.
J Neural Eng ; 17(3): 036014, 2020 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-32380482

RESUMO

OBJECTIVE: Vagus nerve stimulation (VNS) is a nonpharmacologic therapeutic option for patients who have pharmaco-resistant Dravet syndrome (DS). Plentiful efforts have been made for delivering VNS to DS patients, but its effectiveness still requires further verification. We investigated the effectiveness of the VNS treatment of DS patients using brain connectivity analysis with electroencephalography (EEG). APPROACH: Twenty pharmaco-resistant DS patients were selected to undergo VNS implantation and classified into responder and non-responder groups after 24 months post-VNS. The effect of VNS between 6 months pre- and 6, 12, and 24 months post-VNS in all patients, responders, and non-responders on four different frequency categories of four brain parameters were compared using resting-state EEG. MAIN RESULTS: In alpha and beta bands, all patients showed positive results for characteristic path length (CPL), global efficiency (GE), and transitivity after VNS treatment, and changes in betweenness centrality (BC) were not significant. The difference in transitivity between responders and non-responders is more pronounced than those in CPL and GE are, in both the alpha (p < 0.015) and beta (p < 0.001) bands. There was an obvious change in BC, especially in the alpha band, as the hubs tended to move from frontal lobe to parietal lobe for responders; however, there was no change for the non-responders. SIGNIFICANCE: We investigated the alteration in brain connectivity of DS patients in alpha and beta bands during a long-term follow-up and found the responders have a decreased transitivity after the VNS treatment. Moreover, the hubs with high values in the alpha band tended to move from frontal lobe to parietal lobe for responders after VNS treatment.


Assuntos
Epilepsias Mioclônicas , Estimulação do Nervo Vago , Encéfalo/diagnóstico por imagem , Eletroencefalografia , Epilepsias Mioclônicas/diagnóstico , Epilepsias Mioclônicas/terapia , Humanos , Resultado do Tratamento , Nervo Vago
12.
Sci Rep ; 9(1): 680, 2019 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-30679820

RESUMO

Inter-digital capacitors (IDCs) with aerosol-deposition (AD) high-k dielectric layer were compared via simulation and measurements of bare IDCs and AD IDCs at room temperature and subjected to a post-annealing process for realizing capacitive super-sensing applications. IDCs with thin AD films can provide higher capacitive intensity and improvements for other dielectric performances. Therefore, IDC patterns with AD high-k dielectric layers were fabricated by varying the finger widths and gap. Moreover, we analyzed the layer microstructure design patterns using simulations and experiments with AD BaTiO3 as-deposited IDCs and IDCs subjected to annealing at 500 °C. These three different IDCs were measured using an impedance analyzer; furthermore, the AD BaTiO3 films were evaluated using X-ray diffraction, atomic force microscopy, and traveling electron microscopy. The results for the IDCs with the AD BaTiO3 film show the highest capacitance when compared with other thin layer capacitors, which is expected to be useful in realizing super-sensing applications in the future.

13.
Sci Rep ; 8(1): 3414, 2018 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-29467376

RESUMO

Corpus callosotomy (CC) is an effective palliative surgical treatment for patients with Lennox-Gastaut Syndrome (LGS). However, research on the long-term functional effects of CC is sparse. We aimed to investigate these effects and their associated clinical conditions over the two years after CC. Long-term clinical EEG recordings of 30 patients with LGS who had good and bad seizure outcome after CC were collected and retrospectively studied. It was found that CC caused brain network 'hubs' to shift from paramedian to lateral regions in the good-recovery group, which reorganized the brain network into a more homogeneous state. We also found increased local clustering coefficients in patients with bad outcomes and decreases, implying enhanced network integration, in patients with good outcomes. The small worldness of brain networks in patients with good outcomes increased in the two years after CC, whereas it decreased in patients with bad outcomes. The covariation of small-worldness with the rate of reduction in seizure frequency suggests that this can be used as an indicator of CC outcome. Local and global network changes during the long-term state might be associated with the postoperative recovery process and could serve as indicators for CC outcome and long-term LGS recovery.


Assuntos
Corpo Caloso/fisiologia , Corpo Caloso/cirurgia , Síndrome de Lennox-Gastaut/fisiopatologia , Síndrome de Lennox-Gastaut/cirurgia , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos , Convulsões/fisiopatologia
14.
ACS Appl Mater Interfaces ; 10(1): 851-863, 2018 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-29212324

RESUMO

Aerosol deposition (AD) is a novel ceramic film preparation technique exhibiting the advantages of room-temperature operation and highly efficient film growth. Despite these advantages, AD has not been used for preparing humidity-sensing films. Herein, room-temperature AD was utilized to deposit BaTiO3 films on a glass substrate with a Pt interdigital capacitor, and their humidity-sensing performances were evaluated in detail, with further optimization performed by postannealing at temperatures of 100, 200, ..., 600 °C. Sensor responses (i.e., capacitance variations) were measured in a humidity chamber for relative humidities (RHs) of 20-90%, with the best sensitivity (461.02) and a balanced performance at both low and high RHs observed for the chip annealed at 500 °C. In addition, its response and recovery were extremely fast, respectively, at 3 and 6 s and it kept a stable recording with the maximum error rate of 0.1% over a 120 h aging test. Compared with other BaTiO3-based humidity sensors, the above chip required less thermal energy for its preparation but featured a more than 2-fold higher sensitivity and a superior detection balance at RHs of 20-90%. Cross-sectional transmission electron microscopy imaging revealed that the prepared film featured a transitional variable-density structure, with moisture absorption and desorption being promoted by a specific capillary structure. Finally, a bilayer physical model was developed to explain the mechanism of enhanced humidity sensitivity by the prepared BaTiO3 film.

15.
Micromachines (Basel) ; 9(9)2018 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-30424396

RESUMO

This paper reports on the use of gallium arsenide-based integrated passive device technology for the implementation of a miniaturized bandpass filter that incorporates an intertwined circle-shaped spiral inductor and an integrated center-located capacitor. Air-bridge structures were introduced to the outer inductor and inner capacitor for the purpose of space-saving, thereby yielding a filter with an overall chip area of 1178 µm × 970 µm. Thus, not only is the chip area minimized, but the magnitude of return loss is also improved as a result of selective variation of bridge capacitance. The proposed device possesses a single passband with a central frequency of 1.71 GHz (return loss: 32.1 dB), and a wide fractional bandwidth (FBW) of 66.63% (insertion loss: 0.50 dB). One transmission zero with an amplitude of 43.42 dB was obtained on the right side of the passband at 4.48 GHz. Owing to its miniaturized chip size, wide FBW, good out-band suppression, and ability to yield high-quality signals, the fabricated bandpass filter can be implemented in various L-band applications such as mobile services, satellite navigation, telecommunications, and aircraft surveillance.

16.
Brain Dev ; 39(2): 138-144, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27686687

RESUMO

OBJECTIVE: The purpose of the current study was to characterize the frequency profiles of epileptogenic regions, independent of visible epileptiform discharges, in intracranial EEG (iEEG) recordings of Lennox-Gastaut syndrome (LGS) patients. METHODS: We selected eight LGS patients who underwent resective surgery in the absence of definite neuroimaging findings. We calculated the absolute and relative band powers of continuous spike-free iEEG data and compared the characteristics of the resected and remaining regions. RESULTS: For absolute band powers, there was a trend for higher absolute gamma band power in the remaining brain section. We also found that the absolute delta power in the resected area was higher than that in the remaining area. However, this trend was not statistically different in all patients. For relative band powers, we found decreased relative band power in the beta and gamma band ranges within the areas defined by the surgical margins. Delta, theta, and alpha relative band power differences between the resected and remaining areas were inconsistent between the subjects. CONCLUSIONS: Our results showed systematic relative beta and gamma band power variation in the resected areas of LGS patients.


Assuntos
Encéfalo/fisiopatologia , Encéfalo/cirurgia , Eletrocorticografia , Síndrome de Lennox-Gastaut/fisiopatologia , Síndrome de Lennox-Gastaut/cirurgia , Procedimentos Neurocirúrgicos , Adolescente , Ritmo beta/fisiologia , Encéfalo/diagnóstico por imagem , Criança , Pré-Escolar , Ritmo Delta/fisiologia , Feminino , Ritmo Gama/fisiologia , Humanos , Síndrome de Lennox-Gastaut/diagnóstico por imagem , Masculino , Adulto Jovem
17.
Front Neurol ; 8: 456, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28928710

RESUMO

OBJECTIVES: This study aimed to investigate the functional network effects of corpus callosotomy (CC), a well-recognized palliative surgical therapy for patients with Lennox-Gastaut syndrome (LGS). Specifically, we sought to gain insight into the effects of CC on LGS remission, based on brain networks in LGS by calculating network metrics and evaluating by network measures before and after surgery. METHODS: Electroencephalographic recordings made during preoperative and 3-month postoperative states in 14 patients with LGS who had undergone successful CC were retrospectively analyzed. First, undirected correlation matrices were constituted for the mathematical expression of functional networks. Then, we plotted these networks to analyze the effects of CC on connectivity. In addition, conventional local and global network measures were applied to evaluate differences in network topology between preoperative and postoperative states. RESULTS: In the preoperative state, hubs were mainly distributed around the paramedian regions. After CC, the hubs moved from the paramedian regions to the dual-hemisphere and even the lateral regions. Thus, the general connectivity state became more homogeneous, which was verified by network plots and statistical analysis of local measures. The results of global network measures indicated a decreased clustering coefficient in the delta band, decreased characteristic path length in both the delta and gamma bands, and increased global efficiency in the gamma band. CONCLUSION: Our results showed a consistent variation in the global brain network that converted to a small-world topology with an optimal balance of functional integration and segregation of the network. Such changes were positively correlated with satisfactory surgery results, which could be interpreted as being indicative of LGS recovery process after CC. For patients with refractory LGS along with no focal epileptogenic zone findings, which were not suitable for the resective surgical therapy, our results verified that CC could work as an effective surgical treatment option.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA