1.
Artif Organs ; 40(3): E12-24, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26416723

RESUMO

Successful visual prostheses require stable, long-term attachment. Epiretinal prostheses, in particular, require attachment methods to fix the prosthesis onto the retina. The most common method is fixation with a retinal tack; however, tacks cause retinal trauma, and surgical proficiency is important to ensure optimal placement of the prosthesis near the macula. Accordingly, alternate attachment methods are required. In this study, we detail a novel method of magnetic attachment for an epiretinal prosthesis using two prostheses components positioned on opposing sides of the retina. The magnetic attachment technique was piloted in a feline animal model (chronic, nonrecovery implantation). We also detail a new method to reliably control the magnet coupling force using heat. It was found that the force exerted upon the tissue that separates the two components could be minimized as the measured force is proportionately smaller at the working distance. We thus detail, for the first time, a surgical method using customized magnets to position and affix an epiretinal prosthesis on the retina. The position of the epiretinal prosthesis is reliable, and its location on the retina is accurately controlled by the placement of a secondary magnet in the suprachoroidal location. The electrode position above the retina is less than 50 microns at the center of the device, although there were pressure points seen at the two edges due to curvature misalignment. The degree of retinal compression found in this study was unacceptably high; nevertheless, the normal structure of the retina remained intact under the electrodes.


Assuntos
Imãs/química , Implantação de Prótese/métodos , Retina/cirurgia , Próteses Visuais/química , Animais , Gatos , Eletrodos Implantados , Temperatura Alta , Magnetismo/métodos , Desenho de Prótese , Retina/ultraestrutura
2.
Adv Biosyst ; 1(1-2): e1600003, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32646182

RESUMO

Retinal implants restore a sense of vision, for a growing number of users worldwide. Nevertheless, visual acuities provided by the current generation of devices are low. The quantity of information transferable to the retina using existing implant technologies is limited, far below receptor cells' capabilities. Many agree that increasing the information density deliverable by a retinal prosthesis requires devices with stimulation electrodes that are both dense and numerous. This work describes a new generation of retinal prostheses capable of upscaling the information density conveyable to the retina. Centered on engineered diamond materials, the implant is very well tolerated and long-term stable in the eye's unique physiological environment and capable of delivering highly versatile stimulation waveforms - both key attributes in providing useful vision. Delivery of high-density information, close to the retina with the flexibility to alter stimulation parameters in situ provides the best chance for success in providing high acuity prosthetic vision.

3.
Biomaterials ; 53: 464-74, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25890743

RESUMO

As the field of biomedical implants matures the functionality of implants is rapidly increasing. In the field of neural prostheses this is particularly apparent as researchers strive to build devices that interact with highly complex neural systems such as vision, hearing, touch and movement. A retinal implant, for example, is a highly complex device and the surgery, training and rehabilitation requirements involved in deploying such devices are extensive. Ideally, such devices will be implanted only once and will continue to function effectively for the lifetime of the patient. The first and most pivotal factor that determines device longevity is the encapsulation that separates the sensitive electronics of the device from the biological environment. This paper describes the realisation of a free standing device encapsulation made from diamond, the most impervious, long lasting and biochemically inert material known. A process of laser micro-machining and brazing is described detailing the fabrication of hermetic electrical feedthroughs and laser weldable seams using a 96.4% gold active braze alloy, another material renowned for biochemical longevity. Accelerated ageing of the braze alloy, feedthroughs and hermetic capsules yielded no evidence of corrosion and no loss of hermeticity. Samples of the gold braze implanted for 15 weeks, in vivo, caused minimal histopathological reaction and results were comparable to those obtained from medical grade silicone controls. The work described represents a first account of a free standing, fully functional hermetic diamond encapsulation for biomedical implants, enabled by gold active alloy brazing and laser micro-machining.


Assuntos
Ligas , Materiais Biocompatíveis , Diamante , Ouro , Próteses Neurais , Cimento de Óxido de Zinco e Eugenol , Animais , Cobaias