Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Lab Anal ; 32(6): e22425, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29500827

RESUMO

BACKGROUND: We tested the hypothesis that the results of the same test performed on point-of-care blood gas analysis (BGA) machine and automatic analyzer (AA) machine in central laboratory have high degree of concordance in critical care patients and that the two test methods could be used interchangeably. METHODS: We analyzed 9398 matched pairs of BGA and AA results, obtained from 1765 patients. Concentration pairs of the following analytes were assessed: hemoglobin, glucose, sodium, potassium, chloride, and bicarbonate. We determined the agreement using concordance correlation coefficient (CCC) and Bland-Altman analysis. The difference in results was also assessed against the United States Clinical Laboratory Improvement Amendments (US-CLIA) 88 rules. The test results were considered to be interchangeable if they were within the US-CLIA variability criteria and would not alter the clinical management when compared to each other. RESULTS: The median time interval between sampling for BGA and AA in each result pair was 5 minutes. The CCC values ranged from 0.89(95% CI 0.89-0.90) for chloride to 0.98(95% CI 0.98-0.99) for hemoglobin. The largest bias was for hemoglobin. The limits of agreement relative to bias were largest for sodium, with 3.4% of readings outside the US-CLIA variation rule. The number of readings outside the US-CLIA acceptable variation was highest for glucose (7.1%) followed by hemoglobin (5.9%) and chloride (5.2%). CONCLUSION: We conclude that there is moderate to substantial concordance between AA and BGA machines on tests performed in critically ill patients. However, the two tests methods cannot be used interchangeably, except for potassium.

2.
Interv Cardiol ; 14(1): 26-30, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30863461

RESUMO

Treatment of degenerative aortic stenosis has been transformed by transcatheter aortic valve implantation (TAVI) over the past 10-15 years. The success of various technologies has led operators to attempt to broaden the indications, and many patients with native valve aortic regurgitation have been treated 'off label' with similar techniques. However, the alterations in the structure of the valve complex in pure native aortic regurgitation are distinct to those in degenerative aortic stenosis, and there are unique challenges to be overcome by percutaneous valves. Nevertheless some promise has been shown with both non-dedicated and dedicated devices. In this article, the authors explore some of these challenges and review the current evidence base for TAVI for aortic regurgitation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA