RESUMO
AIMS: In patients presenting with spontaneous sustained ventricular tachycardia (VT) from the outflow-tract region without overt structural heart disease ablation may target premature ventricular contractions (PVCs) when VT is not inducible. We aimed to determine whether inducibility of VT affects ablation outcome. METHODS AND RESULTS: Data from 54 patients (31 men; age, 52 ± 13 years) without overt structural heart disease who underwent catheter ablation for symptomatic sustained VT originating from the right- or left-ventricular outflow region, including the great vessels. A single morphology of sustained VT was inducible in 18 (33%, SM group) patients, and 11 (20%) had multiple VT morphologies (MM group). VT was not inducible in 25 (46%) patients (VTni group). After ablation, VT was inducible in none of the SM group and in two (17%) patients in the MM group. In the VTni group, ablation targeted PVCs and 12 (48%) patients had some remaining PVCs after ablation. During follow-up (21 ± 19 months), VT recurred in 46% of VTni group, 40% of MM inducible group, and 6% of the SM inducible group (P = 0.004). Analysis of PVC morphology in the VTi group further supported the limitations of targeting PVCs in this population. CONCLUSION: Absence of inducible VT and multiple VT morphologies are not uncommon in patients with documented sustained outflow-tract VT without overt structural heart disease. Inducible VT is associated with better outcomes, suggesting that attempts to induce VT to guide ablation are important in this population.
Assuntos
Ablação por Cateter/normas , Eletrocardiografia/classificação , Ventrículos do Coração/fisiopatologia , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/cirurgia , Adulto , Idoso , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Recidiva , Resultado do TratamentoRESUMO
BACKGROUND: Ventricular arrhythmias (VAs) from the left ventricular outflow tract (LVOT) region can be inaccessible for ablation because of epicardial fat or overlying coronary arteries. OBJECTIVE: We describe surgical cryoablation of this type of VA. METHODS: From March 2009 to 2014, 190 consecutive patients with VAs originating from the LVOT underwent ablation at our institution. Four patients (2%) underwent surgical cryoablation for highly symptomatic VAs after failing catheter ablation. RESULTS: In all patients, endocardial or percutaneous epicardial mapping was consistent with origin in the LVOT. In 2 patients, the points of earliest activation during VAs were marked with a bipolar pacing lead in the overlying cardiac vein for guidance during surgery. Surgical cryoablation was successful in 3 of the 4 patients. The fourth patient subsequently had successful endocardial catheter ablation. During a mean follow-up of 22 ± 16 months (range 4-42 months), all patients showed abolition of or marked reduction in symptomatic VA. However, 1 patient subsequently required percutaneous intervention to the left anterior descending coronary artery; another developed progressive left ventricular systolic dysfunction caused by nonischemic cardiomyopathy; and a third patient underwent permanent pacemaker implantation because of complete atrioventricular block after concomitant aortic valve replacement. CONCLUSION: Surgical cryoablation is an option for highly symptomatic drug-resistant VAs emanating from the LVOT region. Despite extensive preoperative mapping, the procedure is not effective for all patients, and coronary injury is a risk.
Assuntos
Criocirurgia , Taquicardia Ventricular/cirurgia , Adulto , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-IdadeRESUMO
BACKGROUND: Catheter ablation for ventricular arrhythmia (VA) near the distal great cardiac vein (GCV) is often challenging, and data are limited. METHODS AND RESULTS: Analysis was performed in 30 patients (19 men; age, 52.8±15.5 years) who underwent catheter ablation for focal VA (11 ventricular tachycardia and 19 premature contractions) with early activation in the GCV (36.7±8.0 ms pre-QRS). Angiography in 27 patients showed earliest GCV site within 5 mm of a coronary artery in 20 (74%). Ablation was performed in the GCV in 15 patients and abolished VA in 8. Ablation was attempted at adjacent non-GCV sites in 19 patients and abolished VA in 5 patients (4 from the left ventricular endocardium and 1 from the left coronary cusp); all success had VA with an initial r wave in lead I and activation ≤7 ms after the GCV (GCV-non-GCV interval). In 13 patients, percutaneous epicardial mapping was performed, but because of adjacent coronaries only 2 received radiofrequency application with VA elimination in 1. Surgical cryoablation was performed in 3 patients and abolished VA in 2. Overall acute success was achieved in 16 (53%) patients. After a median of 2.8 months, 13 patients remained free of VA. Major complications occurred in 4 patients, including coronary injury requiring stenting. CONCLUSIONS: Ablation for this arrhythmia is challenging and often limited by the adjacent coronary vessels. Success of anatomically guided endocardial ablation may be identified by a short GCV-non-GCV interval and r wave in lead I.
Assuntos
Vasos Coronários , Ventrículos do Coração/cirurgia , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/cirurgia , Adulto , Idoso , Ablação por Cateter/efeitos adversos , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/lesões , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Traumatismos Cardíacos/etiologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento , Lesões do Sistema Vascular/etiologia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/fisiopatologiaRESUMO
BACKGROUND: Catheter ablation for ventricular tachycardia (VT) from structural heart disease has a significant risk of recurrence, but the optimal duration for in-hospital monitoring is not defined. This study assesses the timing, correlates, and prognostic significance of early VT recurrence after ablation. METHODS AND RESULTS: Of 370 patients (313 men; aged 63.0±13.2 years) who underwent a first radiofrequency ablation for sustained monomorphic VT associated with structural heart disease from 2008 to 2012, sustained VT recurred in 81 patients (22%) within 7 days. In multivariable analysis, early recurrence was associated with New York Heart Association classification ≥III (odds ratio [OR] 1.90, 95% confidence interval [CI] 1.03-3.48; P=0.04), dilated cardiomyopathy (OR 1.93, 95% CI 1.03-3.57; P=0.04), prevalence of VT storm before the procedure (OR 2.62, 95% CI 1.48-4.65; P=0.001), a greater number of induced VTs (OR 1.24, 95% CI 1.07-1.45; P=0.006), and acute failure or no final induction test (OR 1.88, 95% CI 1.03-3.40; P=0.04). During a median of 2.5 (1.2, 4.0) years of follow-up, early VT recurrence was an independent correlates of mortality (hazard ratio 2.59, 95% CI 1.52-4.34; P=0.0005). CONCLUSIONS: Patients who have early recurrences of VT after ablation are a high risk group who may be identifiable from their clinical profile. Further study is warranted to define the optimal treatment strategies for this patient group.
Assuntos
Ablação por Cateter/efeitos adversos , Cardiopatias/complicações , Taquicardia Ventricular/cirurgia , Idoso , Antiarrítmicos/uso terapêutico , Ablação por Cateter/mortalidade , Distribuição de Qui-Quadrado , Feminino , Cardiopatias/mortalidade , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Modelos de Riscos Proporcionais , Recidiva , Estudos Retrospectivos , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/mortalidade , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: The efforts to reduce radiation from cardiac computed tomography (CT) are essential. Using a prospectively triggered, high-pitch dual-source CT protocol, we aim to determine the radiation dose and image quality in patients undergoing pulmonary vein (PV) imaging. METHODS AND RESULTS: In 94 patients (61±9 years; 71% male) who underwent 128-slice dual-source CT (pitch 3.4), radiation dose and image quality were assessed and compared between 69 patients with sinus rhythm and 25 patients with atrial fibrillation. Radiation dose was compared in a subset of 19 patients with prior retrospective or prospectively triggered CT PV scans without high pitch. In a subset of 18 patients with prior magnetic resonance imaging for PV assessment, PV anatomy and scan duration were compared with high-pitch CT. Using the high-pitch protocol, total effective radiation dose was 1.4 (1.3, 1.9) mSv, with no difference between sinus rhythm and atrial fibrillation (1.4 versus 1.5 mSv; P=0.22). No high-pitch CT scans were nondiagnostic or had poor image quality. Radiation dose was reduced with high-pitch (1.6 mSv) compared with standard protocols (19.3 mSv; P<0.0001). This radiation dose reduction was seen with sinus rhythm (1.5 versus 16.7 mSv; P<0.0001) but was more profound with atrial fibrillation (1.9 versus 27.7 mSv; P=0.039). There was excellent agreement of PV anatomy (κ 0.84; P<0.0001) and a shorter CT scan duration (6 minutes) compared with magnetic resonance imaging (41 minutes; P<0.0001). CONCLUSIONS: Using a high-pitch dual-source CT protocol, PV imaging can be performed with minimal radiation dose, short scan acquisition, and excellent image quality in patients with sinus rhythm or atrial fibrillation. This protocol highlights the success of new cardiac CT technology to minimize radiation exposure, giving clinicians a new low-dose imaging alternative to assess PV anatomy.
Assuntos
Fibrilação Atrial/diagnóstico por imagem , Eletrocardiografia , Sistema de Condução Cardíaco/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada Espiral/métodos , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Reprodutibilidade dos TestesRESUMO
Immunization with peptide mimetics of carbohydrate antigens can induce functional carbohydrate-reactive antibodies. Here, we examine the immune characteristics of alternative approaches in prime and boost strategies using glycosylated HIV-1 envelope protein and model tumor associated carbohydrate antigens. Our results indicate that peptide mimotopes either in a DNA or carrier-conjugated format can induce comparable levels of IgM and IgG. Carbohydrate boosting of peptide-primed animals does not affect end-point titer, however, boosting mediates a stable long lasting carbohydrate reactive IgM response, not achievable by carbohydrate immunization alone. Boosting with carbohydrate in animals primed with DNA- or peptide-conjugate, facilitates the induction of detectable IgG with a dominant IgG2a isotype. Immunization with HIV-1 envelope glycoprotein of peptide-primed animals induces different IgG isotype profiles with a dominant IgG1 antibody. We observed that HIV-1 envelope glycoprotein immunization of peptide primed mice induces a cross-reactive cellular response, as detected by cytokine secretion, which lends to IFN-gamma production upon splenocyte stimulation and CTL activity against recombinant vaccinia virus infected cells after in vitro stimulation. DNA immunization with mimotope, inclusion of a T-cell epitope from the HIV-1 envelope protein in the expression cassette and co-administration with IL-12 or GM-CSF encoding plasmids activate a cellular response to the HIV-1 envelope protein.