Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Psychol Public Policy Law ; 21(3): 280-294, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29075092

RESUMO

Despite the importance of damage awards, juries are often at sea about the amounts that should be awarded, with widely differing awards for cases that seem comparable. We tested a new model of damage award decision making by systematically varying the size, context, and meaningfulness of numerical comparisons or anchors. As a result, we were able to elicit large differences in award amounts that replicated for 2 different cases. Although even arbitrary dollar amounts (unrelated to the cases) influenced the size of award judgments, the most consistent effects of numerical anchors were achieved when the amounts were meaningful in the sense that they conveyed the gist of numbers as small or large. Consistent with the model, the ordinal gist of the severity of plaintiff's damages and defendant's liability predicted damage awards, controlling for other factors such as motivation for the award-judgment task and perceived economic damages. Contrary to traditional dual-process approaches, numeracy and cognitive style (e.g., need for cognition and cognitive reflection) were not significant predictors of these numerical judgments, but they were associated with lower levels of variability once the gist of the judgments was taken into account. Implications for theory and policy are discussed.

2.
J Biomed Opt ; 11(3): 34012, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16822062

RESUMO

We recently reported the development of a filament-antibody recognition assay (FARA), in which the presence of virions in solution initiates the formation of enzyme-linked immunosorbent assay (ELISA)-like antibody complexes. The unique features of this assay are that processing is achieved by motion of a filament and that, in the presence of a virus, antibody-virus complexes are coupled to the filament at known locations. In this work, we combine the unique features of this assay with a 638-nm laser-based optical detector to enable adaptive control of virus detection. Integration of on-line fluorescence detection yields approximately a five-fold increase in signal-to-noise ratio (SNR) compared to the fluorescence detection method reported previously. A one-minute incubation with an M13K07 test virus is required to detect 10(10) virionsml, and 40 min was required to detect 10(8) virionsml. In tests of the components of an adaptive strategy, a 30-min virus (3.3 x 10(10) virionsml) incubation time, followed by repositioning the filament-captured virus either within the detecting antibody chamber, (20 microg ml) or within the virus chamber, found an increase in signal roughly proportional to the cumulative residence times in these chambers. Furthermore, cumulative fluorescence signals observed for a filament-captured virus after repeated positioning of the filament within the virus chamber are similar to those observed for a single long incubation time. The unique features of the FARA-like design combined with online optical detection to direct subsequent bioprocessing steps provides new flexibility for developing adaptive molecular recognition assays.


Assuntos
Ensaio de Imunoadsorção Enzimática/instrumentação , Espectrometria de Fluorescência/instrumentação , Vírion/isolamento & purificação , Vírus/imunologia , Vírus/isolamento & purificação , Complexo Antígeno-Anticorpo , Ensaio de Imunoadsorção Enzimática/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Fluorescência/métodos , Vírion/imunologia , Virologia/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA