Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
MAGMA ; 33(5): 663-676, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32078074

RESUMO

OBJECTIVE: In dynamic susceptibility contrast MRI (DSC-MRI), an arterial input function (AIF) is required to quantify perfusion. However, estimation of the concentration of contrast agent (CA) from magnitude MRI signal data is challenging. A reasonable alternative would be to quantify CA concentration using quantitative susceptibility mapping (QSM), as the CA alters the magnetic susceptibility in proportion to its concentration. MATERIAL AND METHODS: AIFs with reasonable appearance, selected on the basis of conventional criteria related to timing, shape, and peak concentration, were registered from both ΔR2* and QSM images and mutually compared by visual inspection. Both ΔR2*- and QSM-based AIFs were used for perfusion calculations based on tissue concentration data from ΔR2*as well as QSM images. RESULTS: AIFs based on ΔR2* and QSM data showed very similar shapes and the estimated cerebral blood flow values and mean transit times were similar. Analysis of corresponding ΔR2* versus QSM-based concentration estimates yielded a transverse relaxivity estimate of 89 s-1 mM-1, for voxels identified as useful AIF candidate in ΔR2* images according to the conventional criteria. DISCUSSION: Interestingly, arterial concentration time curves based on ΔR2* versus QSM data, for a standard DSC-MRI experiment, were generally very similar in shape, and the relaxivity obtained in voxels representing blood was similar to tissue relaxivity obtained in previous studies.


Assuntos
Circulação Cerebrovascular , Meios de Contraste , Imageamento por Ressonância Magnética , Perfusão , Reprodutibilidade dos Testes
2.
Magn Reson Med ; 81(2): 1229-1236, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30284727

RESUMO

PURPOSE: To determine the reproducibility of quantitative susceptibility mapping at multiple sites on clinical and preclinical scanners (1.5 T, 3 T, 7 T, and 9.4 T) from different vendors (Siemens, GE, Philips, and Bruker) for standardization of multicenter studies. METHODS: Seven phantoms distributed from the core site, each containing 5 compartments with gadolinium solutions with fixed concentrations between 0.625 mM and 10 mM. Multi-echo gradient echo scans were performed at 1.5 T, 3 T, 7 T, and 9.4 T on 12 clinical and 3 preclinical scanners. DICOM images from the scans were processed into quantitative susceptibility maps using the Laplacian boundary value (LBV) and MEDI+0 automatic uniform reference algorithm. Region of interest (ROI) analyses were performed by a physicist to determine agreement between results from all sites. Measurement reproducibility was assessed using regression, Bland-Altman plots, and the intra-class correlation coefficient (ICC). RESULTS: Quantitative susceptibility mapping (QSM) from all scanners had similar, artifact-free visual appearance. Regression analysis showed a linear relationship between gadolinium concentrations and average QSM measurements for all phantoms (y = 350x - 0.0346, r2 >0.99). The SD of measurements increased almost linearly from 32 ppb to 230 ppb as the measured susceptibility increased from 0.26 ppm to 3.56 ppm. A Bland-Altman plot showed the bias, upper, and lower limits of agreement for all comparisons were -10, -210, and 200 ppb, respectively. The ICC was 0.991 with a 95% CI (0.973, 0.99). CONCLUSIONS: QSM shows excellent multicenter reproducibility for a large range of susceptibility values encountered in cranial and extra-cranial applications on a diverse set of scanner platforms.


Assuntos
Gadolínio/química , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/normas , Algoritmos , Artefatos , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Ferro/análise , Reconhecimento Automatizado de Padrão , Imagens de Fantasmas , Análise de Regressão , Reprodutibilidade dos Testes , Razão Sinal-Ruído
3.
Magn Reson Med ; 77(6): 2203-2214, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27321696

RESUMO

PURPOSE: The partial volume effect (PVE) is an important source of bias in brain perfusion measurements. The impact of tissue PVEs in perfusion measurements with dynamic susceptibility contrast MRI (DSC-MRI) has not yet been well established. The purpose of this study was to suggest a partial volume correction (PVC) approach for DSC-MRI and to study how PVC affects DSC-MRI perfusion results. METHODS: A linear mixed perfusion model for DSC-MRI was derived and evaluated by way of simulations. Twenty healthy volunteers were scanned twice, including DSC-MRI, arterial spin labeling (ASL), and partial volume measurements. Two different algorithms for PVC were employed and assessed. RESULTS: Simulations showed that the derived model had a tendency to overestimate perfusion values in voxels with high fractions of cerebrospinal fluid. PVC reduced the tissue volume dependence of DSC-MRI perfusion values from 44.4% to 4.2% in gray matter and from 55.3% to 14.2% in white matter. One PVC method significantly improved the voxel-wise repeatability, but PVC did not improve the spatial agreement between DSC-MRI and ASL perfusion maps. CONCLUSION: Significant PVEs were found for DSC-MRI perfusion estimates, and PVC successfully reduced those effects. The findings suggest that PVC might be an important consideration for DSC-MRI applications. Magn Reson Med 77:2203-2214, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Encéfalo/fisiologia , Circulação Cerebrovascular/fisiologia , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Modelos Lineares , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artefatos , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Simulação por Computador , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin
4.
MAGMA ; 30(6): 555-566, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28631203

RESUMO

OBJECTIVE: One major issue in dynamic susceptibility contrast MRI (DSC-MRI) is to accurately determine contrast agent (CA) concentration, since T2* relaxivity in vivo is generally unknown and varies between blood and tissue. In this study, quantitative susceptibility mapping (QSM) was used for quantification of CA concentration. MATERIALS AND METHODS: A DSC-MRI protocol, including phase data acquisition, was applied to 20 healthy volunteers in a test-retest study. By selecting a CSF reference region of interest (ROI), the values of all QSM images were shifted to show no CA-induced change in CSF. CA concentration and cerebral blood volume (CBV) were estimated using shifted QSM data. CSF reference ROI optimization was evaluated by investigation of CBV repeatability. The CBV age dependence was analysed and tissue T2* relaxivity was estimated. RESULTS: The best repeatability of CBV, using an optimal CSF reference ROI, showed test-versus-retest correlations of r = 0.81 and r = 0.91 for white and grey matter, respectively. A slight CBV decrease with age was observed, and the estimated in vivo T2* relaxivity was 85 mM-1s-1. CONCLUSION: Provided that a carefully selected CSF reference ROI is used to shift QSM image values, susceptibility information can be used to estimate concentration of contrast agent and to calculate CBV.


Assuntos
Volume Sanguíneo Cerebral , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Meios de Contraste/farmacocinética , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Pessoa de Meia-Idade , Software
5.
MAGMA ; 29(6): 823-831, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27295051

RESUMO

OBJECTIVES: Contrast agent (CA) relaxivities are generally not well established in vivo, and the relationship between frequency/phase shift and magnetic susceptibility might be a useful alternative for CA quantification. MATERIALS AND METHODS: Twenty volunteers (25-84 years old) were investigated using test-retest pre-bolus dynamic susceptibility-contrast (DSC) magnetic resonance imaging (MRI). The pre-bolus phase-based venous output function (VOF) time integral was used for arterial input function (AIF) rescaling. Resulting cerebral blood flow (CBF) data for grey matter (GM) were compared with pseudo-continuous arterial spin labelling (ASL). During the main bolus CA passage, the apparent spatial shift (pixel shift) of the superior sagittal sinus (seen in single-shot echo-planar imaging (EPI)) was converted to CA concentration and compared with conventional ΔR2*-based data and with a predicted phase-based VOF from the pre-bolus experiment. RESULTS: The phase-based pre-bolus VOF resulted in a reasonable inter-individual GM CBF variability (coefficient of variation 28 %). Comparison with ASL CBF values implied a tissue R2*-relaxivity of 32 mM-1 s-1. Pixel-shift data at low concentrations (data not available at peak concentrations) were in reasonable agreement with the predicted phase-based VOF. CONCLUSION: Susceptibility-induced phase shifts and pixel shifts are potentially useful for large-vein CA quantification. Previous predictions of a higher R2*-relaxivity in tissue than in blood were supported.


Assuntos
Angiografia por Ressonância Magnética/métodos , Veias/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Calibragem , Circulação Cerebrovascular , Simulação por Computador , Meios de Contraste/química , Imagem Ecoplanar , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Marcadores de Spin , Veias/patologia
7.
J Neuroimaging ; 32(3): 442-458, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35128747

RESUMO

BACKGROUND AND PURPOSE: Cerebral tissue oxygenation is a critical brain viability parameter, and the magnetic properties of hemoglobin offer the opportunity to noninvasively quantify oxygen extraction fraction (OEF) by magnetic resonance imaging (MRI). Ultrahigh-field MRI shows advantages such as increased sensitivity to magnetic susceptibility differences and improved signal-to-noise ratio that can be translated into smaller voxel size, but also increased sensitivity to static and B1 field inhomogeneities. The aim was to produce a systematic comparison of three MRI-based methods for estimation of OEF. METHODS: OEF estimates in 16 healthy subjects were obtained at 7T utilizing susceptometry-based oximetry (SBO), quantitative susceptibility mapping (QSM), and transverse relaxation rate (R2*). Two major draining veins, that is, the superior sagittal sinus (SSS) and the straight sinus (SS), were investigated, including mutual agreement between the methods in each of the two different vessels, agreement between vessels as well as potential vessel angle and vessel size dependences. RESULTS: Very good correlation (r = .88) was found between SBO-based and QSM-based OEF estimates in SSS. Only QSM showed a moderate correlation (r = .61) between corresponding OEF estimates in SSS and SS. For SBO, a trend of increasing OEF estimates was observed as the SS vessel angle relative to the main magnetic field increased. No obvious size dependence could be established for any method. The R2*-based OEF estimates were reasonable (35%-36%), but the observed range was somewhat low. CONCLUSION: The results indicate that QSM is a promising candidate for assessment of OEF estimates, for example, providing reasonably robust estimates across a wide range of vessel orientations.


Assuntos
Mapeamento Encefálico , Oxigênio , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico/métodos , Circulação Cerebrovascular , Humanos , Imageamento por Ressonância Magnética/métodos
8.
Heliyon ; 8(12): e12364, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36590544

RESUMO

Background: Estimation of the oxygen extraction fraction (OEF) by quantitative susceptibility mapping (QSM) magnetic resonance imaging (MRI) is promising but requires systematic evaluation. Extraction of OEF-related information from the tissue residue function in dynamic susceptibility contrast MRI (DSC-MRI) has also been proposed. In this study, whole-brain OEF repeatability was investigated, as well as the relationships between QSM-based OEF and DSC-MRI-based parameters, i.e., mean transit time (MTT) and an oxygen extraction index, referred to as apparent OEF (AOEF). Method: Test-retest data were obtained from 20 healthy volunteers at 3 T. QSM maps were reconstructed from 3D gradient-echo MRI phase data, using morphology-enabled dipole inversion. DSC-MRI was accomplished using gradient-echo MRI at a temporal resolution of 1.24 s. Results: The whole-brain QSM-based OEF was (40.4±4.8) % and, in combination with a previously published cerebral blood flow (CBF) estimate, this corresponds to a cerebral metabolic rate of oxygen level of CMRO2 = 3.36 ml O2/min/100 g. The intra-class correlation coefficient [ICC(2,1)] for OEF test-retest data was 0.73. The MTT-versus-OEF and AOEF-versus-OEF relationships showed correlation coefficients of 0.61 (p = 0.004) and 0.52 (p = 0.019), respectively. Discussion: QSM-based OEF showed a convincing absolute level and good test-retest results in terms of the ICC. Moderate to good correlations between QSM-based OEF and DSC-MRI-based parameters were observed. The present results constitute an indicator of the level of robustness that can be achieved without applying extraordinary resources in terms of MRI equipment, imaging protocol, QSM reconstruction, and OEF analysis.

9.
Radiol Res Pract ; 2018: 6709525, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30155300

RESUMO

The local magnetic field inside and around an object in a magnetic resonance imaging unit depends on the magnetic susceptibility of the object being magnetized, in combination with its geometry/orientation. Magnetic susceptibility can thus be exploited as a source of tissue contrast, and susceptibility imaging may also become a useful tool in contrast agent quantification and for assessment of venous oxygen saturation levels. In this study, the accuracy of an established procedure for quantitative susceptibility mapping (QSM) was investigated. Three gel phantoms were constructed with cylinders of varying susceptibility and geometry. Experimental results were compared with simulated and analytically calculated data. An expected linear relationship between estimated susceptibility and concentration of contrast agent was observed. Less accurate QSM-based susceptibility values were observed for cylindrical objects at angles, relative to the main magnetic field, that were close to or larger than the magic angle. Results generally improved for large objects/high spatial resolution and large volume coverage. For simulated phase maps, accurate susceptibility quantification by QSM was achieved also for more challenging geometries. The investigated QSM algorithm was generally robust to changes in measurement and calculation parameters, but experimental phase data of sufficient quality may be difficult to obtain in certain geometries.

10.
Clin Physiol Funct Imaging ; 37(2): 211-220, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26490359

RESUMO

INTRODUCTION: Global oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2 ) were quantified in a test-retest study. Cerebral blood flow (CBF) data, required for CMRO2 estimation, were obtained using dynamic susceptibility contrast MRI (DSC-MRI). OEF and CMRO2 were quantified using two separate data sets, that is, conventional high-resolution (HR) gradient echo (GRE) phase maps as well as echo planar imaging (EPI) phase maps taken from the baseline (precontrast) part of the DSC-MRI time series. The EPI phase data were included to elucidate whether an extra HR-GRE scan is needed to obtain information about OEF and CMRO2 , or if this information can be extracted from the DSC-MRI experiment only. METHODS: Twenty healthy volunteers were scanned using 3 T MRI on two occasions. Oxygen saturation levels were obtained from phase data measured in the great cerebral vein of Galen, based on HR-GRE as well as EPI phase maps. In combination with DSC-MRI CBF, this allowed for calculation of OEF and CMRO2 . RESULTS: High-resolution-gradient echo- and EPI-based phase images resulted in similar OEF spread and repeatability, with coefficients of variation/intraclass correlation coefficients of 0·26/0·95 and 0·23/0·81, respectively. Absolute OEF values (HR-GRE: 0·40 ± 0·11, EPI: 0·35 ± 0·08) were consistent with literature data. CMRO2 showed similar repeatability, somewhat increased spread and reasonable absolute values (HR-GRE: 3·23 ± 1·26 ml O2 /100 g min-1 , EPI: 2·79 ± 0·89 ml O2 /100 g min-1 ). DISCUSSION: In general, the results obtained by HR-GRE and EPI showed comparable characteristics. The EPI methodology could potentially be improved using a slightly modified DSC-MRI protocol (e.g. with regard to spatial resolution and slice gap).


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular , Imageamento por Ressonância Magnética/métodos , Consumo de Oxigênio , Oxigênio/sangue , Imagem de Perfusão/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Encéfalo/metabolismo , Feminino , Voluntários Saudáveis , Hemoglobinas/metabolismo , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Oxiemoglobinas/metabolismo , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo
11.
Tomography ; 3(3): 153-162, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30042979

RESUMO

Chemical shift-encoded imaging (CSEI) is the most common magnetic resonance imaging fat-water separation method. However, when high spatial resolution fat fraction (FF) images are desired, CSEI might be challenging owing to the increased interecho spacing. Here, 3 T2-based methods have been assessed as alternative methods for obtaining high-resolution FF images. Images from the calf of 10 healthy volunteers were acquired; FF maps were then estimated using 3 T2-based methods (2- and 3-parameter nonlinear least squares fit and a Bayesian probability method) and CSEI for reference. In addition, simulations were conducted to characterize the performance of various methods. Here, all T2-based methods resulted in qualitatively improved high-resolution FF images compared with high-resolution CSEI. The 2-parameter fit showed best quantitative agreement to low-resolution CSEI, even at low FF. The estimated T2-values of fat and water, and the estimated muscle FF of the calf, agreed well with previously published data. In conclusion, T2-based methods can provide improved high-resolution FF images of the calf compared with the CSEI method.

12.
Tomography ; 3(2): 74-78, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28825038

RESUMO

Dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) following bolus injection of gadolinium contrast agent (CA) is widely used for the estimation of brain perfusion parameters such as cerebral blood volume (CBV), cerebral blood flow (CBF), and mean transit time (MTT) for both clinical and research purposes. Although it is predicted that DSC-MRI will have superior performance at high magnetic field strengths, to the best of our knowledge, there are no reports of 7 T DSC-MRI in the literature. It is plausible that the transfer of DSC-MRI to 7 T may be accompanied by increased [Formula: see text] relaxivity in tissue and a larger difference in [Formula: see text]-versus-concentration relationships between tissue and large vessels. If not accounted for, this will subsequently result in apparent CBV and CBF estimates that are higher than those reported previously at lower field strengths. The aims of this study were therefore to assess the feasibility of 7 T DSC-MRI and to investigate the apparent field-strength dependence of CBV and CBF estimates. In total, 8 healthy volunteers were examined using DSC-MRI at 7 T. A reduced CA dose of 0.05 mmol/kg was administered to decrease susceptibility artifacts. CBV, CBF, and MTT maps were calculated using standard DSC-MRI tracer-kinetic theory. Subject-specific arterial partial volume correction factors were obtained using a tail-scaling approach. Compared with literature values obtained using the tail-scaling approach at 1.5 T and 3 T, the CBV and CBF values of the present study were found to be further overestimated. This observation is potentially related to an inferred field-strength dependence of transverse relaxivities, although issues related to the CA dose must also be considered.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA