Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Int J Mol Sci ; 24(9)2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37175506

RESUMO

Cell-therapy-based nerve repair strategies hold great promise. In the field, there is an extensive amount of evidence for better regenerative outcomes when using tissue-engineered nerve grafts for bridging severe gap injuries. Although a massive number of studies have been performed using rodents, only a limited number involving nerve injury models of large animals were reported. Nerve injury models mirroring the human nerve size and injury complexity are crucial to direct the further clinical development of advanced therapeutic interventions. Thus, there is a great need for the advancement of research using large animals, which will closely reflect human nerve repair outcomes. Within this context, this review highlights various stem cell-based nerve repair strategies involving large animal models such as pigs, rabbits, dogs, and monkeys, with an emphasis on the limitations and strengths of therapeutic strategy and outcome measurements. Finally, future directions in the field of nerve repair are discussed. Thus, the present review provides valuable knowledge, as well as the current state of information and insights into nerve repair strategies using cell therapies in large animals.


Assuntos
Células-Tronco Mesenquimais , Traumatismos dos Nervos Periféricos , Doenças do Sistema Nervoso Periférico , Traumatismos do Sistema Nervoso , Humanos , Animais , Coelhos , Cães , Suínos , Engenharia Tecidual , Células de Schwann/fisiologia , Células-Tronco , Regeneração Nervosa/fisiologia , Traumatismos dos Nervos Periféricos/terapia , Nervo Isquiático/lesões
2.
JACC Clin Electrophysiol ; 9(2): 232-242, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36858690

RESUMO

BACKGROUND: Multiple smart devices capable to detect atrial fibrillation (AF) are presently available. Sensitivity and specificity for the detection of AF may differ between available smart devices, and this has not yet been adequately investigated. OBJECTIVES: The aim was to assess the accuracy of 5 smart devices in identifying AF compared with a physician-interpreted 12-lead electrocardiogram as the reference standard in a real-world cohort of patients. METHODS: We consecutively enrolled patients presenting to a cardiology service at a tertiary referral center in a prospective, diagnostic study. RESULTS: We prospectively analyzed 201 patients (31% women, median age 66.7 years). AF was present in 62 (31%) patients. Sensitivity and specificity for the detection of AF were comparable between devices: 85% and 75% for the Apple Watch 6, 85% and 75% for the Samsung Galaxy Watch 3, 58% and 75% for the Withings Scanwatch, 66% and 79% for the Fitbit Sense, and 79% and 69% for the AliveCor KardiaMobile, respectively. The rate of inconclusive tracings (the algorithm was unable to determine the heart rhythm) was 18%, 17%, 24%, 21%, and 26% for the Apple Watch 6, Samsung Galaxy Watch 3, Withings Scan Watch, Fitbit Sense, and AliveCor KardiaMobile (P < 0.01 for pairwise comparison), respectively. By manual review of inconclusive tracings, the rhythm could be determined in 955 (99%) of 969 single-lead electrocardiograms. Regarding patient acceptance, the Apple Watch was ranked first (39% of participants). CONCLUSIONS: In this clinical validation of 5 direct-to-consumer smart devices, we found differences in the amount of inconclusive tracings diminishing sensitivity and specificity of the smart devices. In a clinical setting, manual review of tracings is required in about one-fourth of cases.


Assuntos
Fibrilação Atrial , Dispositivos Eletrônicos Vestíveis , Humanos , Feminino , Idoso , Masculino , Estudos Prospectivos , Algoritmos , Eletrocardiografia
3.
J Am Heart Assoc ; 12(6): e028255, 2023 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-36926939

RESUMO

Background Patients with atrial fibrillation (AF) face an increased risk of death and major adverse cardiovascular events (MACE). We aimed to assess the predictive value of the novel atrial-specific biomarker BMP10 (bone morphogenetic protein 10) for death and MACE in patients with AF in comparison with NT-proBNP (N-terminal prohormone of B-type natriuretic peptide). Methods and Results BMP10 and NT-proBNP were measured in patients with AF enrolled in Swiss-AF (Swiss Atrial Fibrillation Study), a prospective multicenter cohort study. A total of 2219 patients were included (median follow-up 4.3 years [interquartile range 3.9, 5.1], mean age 73±9 years, 73% male). In multivariable Cox proportional hazard models, the adjusted hazard ratio (aHR) associated with 1 ng/mL increase of BMP10 was 1.60 (95% CI, 1.37-1.87) for all-cause death, and 1.54 (95% CI, 1.35-1.76) for MACE. For all-cause death, the concordance index was 0.783 (95% CI, 0.763-0.809) for BMP10, 0.784 (95% CI, 0.765-0.810) for NT-proBNP, and 0.789 (95% CI, 0.771-0.815) for both biomarkers combined. For MACE, the concordance index was 0.732 (95% CI, 0.715-0.754) for BMP10, 0.747 (95% CI, 0.731-0.768) for NT-proBNP, and 0.750 (95% CI, 0.734-0.771) for both biomarkers combined. When grouping patients according to NT-proBNP categories (<300, 300-900, >900 ng/L), higher aHRs were observed in patients with high BMP10 in the categories of low NT-proBNP (all-cause death aHR, 2.28 [95% CI, 1.15-4.52], MACE aHR, 1.88 [95% CI, 1.07-3.28]) and high NT-proBNP (all-cause death aHR, 1.61 [95% CI, 1.14-2.26], MACE aHR, 1.38 [95% CI, 1.07-1.80]). Conclusions BMP10 strongly predicted all-cause death and MACE in patients with AF. BMP10 provided additional prognostic information in low- and high-risk patients according to NT-proBNP stratification. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT02105844.


Assuntos
Fibrilação Atrial , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/complicações , Estudos de Coortes , Estudos Prospectivos , Biomarcadores , Prognóstico , Fragmentos de Peptídeos , Peptídeo Natriurético Encefálico , Proteínas Morfogenéticas Ósseas
4.
Front Cardiovasc Med ; 9: 906079, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35811720

RESUMO

Introduction: The Withings Scanwatch (Withings SA, Issy les Moulineaux, France) offers automated analysis of the QTc. We aimed to compare automated QTc-measurements using a single lead ECG of a novel smartwatch (Withings Scanwatch, SW-ECG) with manual-measured QTc from a nearly simultaneously recorded 12-lead ECG. Methods: We enrolled consecutive patients referred to a tertiary hospital for cardiac workup in a prospective, observational study. The QT-interval of the 12-lead ECG was manually interpreted by two blinded, independent cardiologists through the tangent-method. Bazett's formula was used to calculate QTc. Results were compared using the Bland-Altman method. Results: A total of 317 patients (48% female, mean age 63 ± 17 years) were enrolled. HR-, QRS-, and QT-intervals were automatically calculated by the SW in 295 (93%), 249 (79%), and 177 patients (56%), respectively. Diagnostic accuracy of SW-ECG for detection of QTc-intervals ≥ 460 ms (women) and ≥ 440 ms (men) as quantified by the area under the curve was 0.91 and 0.89. The Bland-Altman analysis resulted in a bias of 6.6 ms [95% limit of agreement (LoA) -59 to 72 ms] comparing automated QTc-measurements (SW-ECG) with manual QTc-measurement (12-lead ECG). In 12 patients (6.9%) the difference between the two measurements was greater than the LoA. Conclusion: In this clinical validation of a direct-to-consumer smartwatch we found fair to good agreement between automated-SW-ECG QTc-measurements and manual 12-lead-QTc measurements. The SW-ECG was able to automatically calculate QTc-intervals in one half of all assessed patients. Our work shows, that the automated algorithm of the SW-ECG needs improvement to be useful in a clinical setting.

5.
Regen Med ; 15(3): 1399-1408, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32308109

RESUMO

Aim: We investigated a potential strategy involving human platelet lysate (HPL) as a media additive for enhancing the neurotrophic potency of human adipose stem cells (ASC). Materials & methods: Dorsal root ganglion explants, ASC and Schwann cells were used for in vitro axonal outgrowth experiments. Results: Remarkably, HPL-supplemented ASC promoted robust axonal outgrowth, in other words, four-times higher than fetal bovine serum-supplemented ASC and even matched to the level of Schwann cells. Further, analysis of regime of growth medium additive supplementation revealed the critical play of HPL in dorsal root ganglion and stem cells co-culture system for mounting effective axonal growth response. Conclusion: HPL supplementation significantly improved the neurotrophic potency of ASC as evidenced by the robust axonal outgrowth; these findings hold significance for nerve tissue engineering applications.


Assuntos
Adipócitos/citologia , Axônios/fisiologia , Plaquetas/citologia , Gânglios Espinais/citologia , Células-Tronco/citologia , Engenharia Tecidual/métodos , Animais , Diferenciação Celular , Células Cultivadas , Embrião de Galinha , Técnicas de Cocultura , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA