Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 166
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Cardiovasc Diabetol ; 23(1): 78, 2024 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-38402177

RESUMO

OBJECTIVE: We aimed to assess the effect of SGLT2i on arrhythmias by conducting a meta-analysis using data from randomized controlled trials(RCTs). BACKGROUND: Sodium-glucose co-transporter 2 inhibitors (SGLT2i) have shown cardioprotective effects via multiple mechanisms that may also contribute to decrease arrhythmias risk. METHODS: We searched in databases (PubMed, Embase, Cochrane Library, and clinicaltrials.gov) up to April 2023. RCTs comparing SGLT2i with placebo were included. The effects of SGLT2i on atrial fibrillation(AF), atrial flutter(AFL), composite AF/AFL, ventricular fibrillation(VF), ventricular tachycardia(VT), ventricular extrasystoles(VES), sudden cardiac death(SCD) and composite VF/VT/SCD were evaluated. RESULTS: 33 placebo-controlled RCTs were included, comprising 88,098 patients (48,585 in SGLT2i vs. 39,513 in placebo). The mean age was 64.9 ± 9.4 years, 63.0% were male. The mean follow-up was 1.4 ± 1.1 years. The pooled-results showed that SGLT2i was associated with a significantly lower risk of AF [risk ratio(RR): 0.88, 95% confidence interval(CI) 0.78-1.00, P = 0.04] and composite AF/AFL (RR: 0.86, 95%CI 0.77-0.96, P = 0.01). This favorable effect appeared to be substantially pronounced in patients with HFrEF, male gender, dapagliflozin, and > 1 year follow-up. For SCD, only in heart failure patients, SGLT2i were found to be associated with a borderline lower risk of SCD (RR: 0.67, P = 0.05). No significant effects of SGLT2i on other ventricular arrhythmic outcomes were found. CONCLUSIONS: SGLT2i lowers the risks of AF and AF/AFL, and this favorable effect appeared to be particularly pronounced in patients with HFrEF, male gender, dapagliflozin, and longer follow-up (> 1 year). SGLT2i lowers the risk of SCD only in heart failure patients.


Assuntos
Fibrilação Atrial , Compostos Benzidrílicos , Glucosídeos , Insuficiência Cardíaca , Inibidores do Transportador 2 de Sódio-Glicose , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Inibidores do Transportador 2 de Sódio-Glicose/efeitos adversos , Volume Sistólico , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Fibrilação Ventricular
2.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38912887

RESUMO

AIMS: Pulsed field ablation (PFA) is an emerging non-thermal ablative modality demonstrating considerable promise for catheter ablation of atrial fibrillation (AF). However, these PFA trials have almost universally included only Caucasian populations, with little data on its effect on other races/ethnicities. The PLEASE-AF trial sought to study the 12-month efficacy and the safety of a multi-electrode hexaspline PFA catheter in treating a predominantly Asian/Chinese population of patients with drug-refractory paroxysmal AF. METHODS AND RESULTS: Patients underwent pulmonary vein (PV) isolation (PVI) by delivering different pulse intensities at the PV ostium (1800 V) and atrium (2000 V). Acute success was defined as no PV potentials and entrance/exit conduction block of all PVs after a 20-min waiting period. Follow-up at 3, 6, and 12 months included 12-lead electrocardiogram and 24-h Holter examinations. The primary efficacy endpoint was 12-month freedom from any atrial arrhythmias lasting at least 30 s. The cohort included 143 patients from 12 hospitals treated by 28 operators: age 60.2 ± 10.0 years, 65.7% male, Asian/Chinese 100%, and left atrial diameter 36.6 ± 4.9 mm. All PVs (565/565, 100%) were successfully isolated. The total procedure, catheter dwell, total PFA application, and total fluoroscopy times were 123.5 ± 38.8 min, 63.0 ± 30.7 min, 169.7 ± 34.6 s, and 27.3 ± 10.1 min, respectively. The primary endpoint was observed in 124 of 143 patients (86.7%). One patient (0.7%) developed a small pericardial effusion 1-month post-procedure, not requiring intervention. CONCLUSION: The novel hexaspline PFA catheter demonstrated universal acute PVI with an excellent safety profile and promising 12-month freedom from recurrent atrial arrhythmias in an Asian/Chinese population with paroxysmal AF. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05114954.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Idoso , Resultado do Tratamento , Povo Asiático , China , Cateteres Cardíacos , Recidiva , Eletrocardiografia Ambulatorial , Fatores de Tempo , Desenho de Equipamento , Frequência Cardíaca , Potenciais de Ação
3.
Pacing Clin Electrophysiol ; 47(6): 714-770, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38687179

RESUMO

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, significantly impacting patients' quality of life and increasing the risk of death, stroke, heart failure, and dementia. Over the past two decades, there have been significant breakthroughs in AF risk prediction and screening, stroke prevention, rhythm control, catheter ablation, and integrated management. During this period, the scale, quality, and experience of AF management in China have greatly improved, providing a solid foundation for the development of the guidelines for the diagnosis and management of AF. To further promote standardized AF management, and apply new technologies and concepts to clinical practice timely and fully, the Chinese Society of Cardiology of Chinese Medical Association and the Heart Rhythm Committee of Chinese Society of Biomedical Engineering jointly developed the Chinese Guidelines for the Diagnosis and Management of Atrial Fibrillation. The guidelines comprehensively elaborated on various aspects of AF management and proposed the CHA2DS2­VASc­60 stroke risk score based on the characteristics of the Asian AF population. The guidelines also reevaluated the clinical application of AF screening, emphasized the significance of early rhythm control, and highlighted the central role of catheter ablation in rhythm control.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Guias de Prática Clínica como Assunto , Fibrilação Atrial/terapia , Fibrilação Atrial/diagnóstico , Humanos , China
4.
Artigo em Inglês | MEDLINE | ID: mdl-38319640

RESUMO

A 60-year-old male patient suffered from frequent episodes of atrial tachycardia (AT), after the index procedure of catheter ablation for paroxysmal atrial fibrillation. During the repeat procedure, the activation map showed that the earliest activation site was located at the roof of left atrium. Multiple ablations at the earliest activation site on the roof failed to terminate the AT; however, ablation within the pulmonary artery at an adjacent anatomical site successfully eliminated the AT, even without recording distinct near-field potential.

5.
Pediatr Surg Int ; 40(1): 42, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38289412

RESUMO

Biliary atresia is an occlusive biliary disease involving intrahepatic and extrahepatic bile ducts. Its etiology and pathogenesis are unclear. There are many manifestations of bile duct involvement in biliary atresia, but little is known about its occurrence and development. In addition, different classification methods have been proposed in different periods of biliary atresia, each with its advantages and disadvantages. The combined application of biliary atresia classification will help to improve the survival rate of patients with native liver. Therefore, this article reviews the development, pathological features, and classification of intrahepatic and extrahepatic bile ducts in biliary atresia, to provide a reference for the study of the pathogenesis and the choice of treatment methods.


Assuntos
Ductos Biliares Extra-Hepáticos , Atresia Biliar , Humanos , Atresia Biliar/diagnóstico , Atresia Biliar/cirurgia , Fígado
6.
BMC Infect Dis ; 23(1): 417, 2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-37340360

RESUMO

BACKGROUND: Previous studies found minimal evidence and raised controversy about the link between hemoglobin and 28-day mortality in sepsis patients. As a result, the purpose of this study was to examine the association between hemoglobin and 28-day death in sepsis patients by analyzing the Medical Intensive Care IV (MIMIC-IV) database from 2008 to 2019 at an advanced medical center in Boston, Massachusetts. METHODS: We extracted 34,916 sepsis patients from the MIMIC-IV retrospective cohort database, using hemoglobin as the exposure variable and 28-day death as the outcome variable, and after adjusting for confounders (demographic indicators, Charlson co-morbidity index, SOFA score, vital signs, medication use status (glucocorticoids, vasoactive drugs, antibiotics, and immunoglobulins, etc.)), we investigated the independent effects of hemoglobin and 28-day risk of death by binary logistic regression as well as two-piecewise linear model, respectively. RESULTS: Hemoglobin levels and 28-day mortality were shown to be non-linearly related.The inflection points were 104 g/L and 128 g/L, respectively. When HGB levels were between 41 and 104 g/L, there was a 10% decrease in the risk of 28-day mortality (OR: 0.90; 95% CI: 0.87 to 0.94, p-value = 0.0001). However, in the range of 104-128 g/L, we did not observe a significant association between hemoglobin and 28-day mortality (OR: 1.17; 95% CI: 1.00 to 1.35, P value = 0.0586). When HGB was in the range of 128-207 g/L, there was a 7% increase in the risk of 28-day mortality for every 1 unit increase in HGB (OR: 1.07; 95% CI: 1.01 to 1.15, P value = 0.0424). CONCLUSION: In patients with sepsis, baseline hemoglobin was related to a U-shaped risk of 28-day death. When HGB was in the range of 12.8-20.7 g/dL, there was a 7% increase in the risk of 28-day mortality for every 1 unit increase in HGB.


Assuntos
Unidades de Terapia Intensiva , Sepse , Humanos , Estudos Retrospectivos , Cuidados Críticos , Hemoglobinas , Prognóstico
7.
Artigo em Inglês | MEDLINE | ID: mdl-37702834

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a prevalent and chronic cardiovascular disorder associated with various pathophysiological alterations, including atrial electrical and structural remodeling, disrupted calcium handling, autonomic nervous system dysfunction, aberrant energy metabolism, and immune dysregulation. Emerging evidence suggests that long non-coding RNAs (lncRNAs) play a significant role in the pathogenesis of AF. OBJECTIVE: This discussion aims to elucidate the involvement of AF-related lncRNAs, with a specific focus on their role as miRNA sponges that modulate crucial signaling pathways, contributing to the progression of AF. We also address current limitations in AF-related lncRNA research and explore potential future directions in this field. Additionally, we summarize feasible strategies and promising delivery systems for targeting lncRNAs in AF therapy. CONCLUSION: In conclusion, targeting AF-related lncRNAs holds substantial promise for future investigations and represents a potential therapeutic avenue for managing AF.

8.
Pacing Clin Electrophysiol ; 46(8): 986-993, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37334721

RESUMO

BACKGROUND: The use of contact force (CF) sensing catheters has provided a revolutionary improvement in catheter ablation (CA) of atrial fibrillation (AF) in the past decade. However, the success rate of CA for AF remains limited, and some complications still occur. METHODS: The TRUEFORCE trial (Catheter Ablation of Atrial Fibrillation using FireMagic TrueForce Ablation Catheter) is a multicenter, prospective, single-arm objective performance criteria study of AF patients who underwent their first CA procedure using FireMagic TrueForce ablation catheter. RESULTS: A total of 120 patients (118 with paroxysmal AF) were included in this study, and 112 patients included in the per-protocol analysis. Pulmonary vein isolation (PVI) was achieved in 100% of the patients, with procedure and fluoroscopy time of 146.63 ± 40.51 min and 12.89 ± 5.59 min, respectively. Freedom from recurrent atrial arrhythmia after ablation was present 81.25% (95% confidence interval [CI]: 72.78%-88.00%) of patients. No severe adverse events (death, stroke/transient ischemic attack [TIA], esophageal fistula, myocardial infarction, thromboembolism, or pulmonary vein stenosis) were detected during the follow-up. Four (4/115, 3.33%) adverse events were documented, including one abdominal discomfort, one femoral artery hematoma, one coughing up blood, and one postoperative palpitation and insomnia. CONCLUSIONS: This study demonstrated the clinical feasibility of FireMagic force-sensing ablation catheter in CA of AF, with a satisfactory short- and long-term efficacy and safety.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Estudos Prospectivos , Resultado do Tratamento , Catéteres , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Recidiva
9.
Pacing Clin Electrophysiol ; 46(9): 1035-1048, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37573146

RESUMO

Transcatheter radiofrequency ablation has been widely introduced for the treatment of tachyarrhythmias. The demand for catheter ablation continues to grow rapidly as the level of recommendation for catheter ablation. Traditional catheter ablation is performed under the guidance of X-rays. X-rays can help display the heart contour and catheter position, but the radiobiological effects caused by ionizing radiation and the occupational injuries worn caused by medical staff wearing heavy protective equipment cannot be ignored. Three-dimensional mapping system and intracardiac echocardiography can provide detailed anatomical and electrical information during cardiac electrophysiological study and ablation procedure, and can also greatly reduce or avoid the use of X-rays. In recent years, fluoroless catheter ablation technique has been well demonstrated for most arrhythmic diseases. Several centers have reported performing procedures in a purposefully designed fluoroless electrophysiology catheterization laboratory (EP Lab) without fixed digital subtraction angiography equipment. In view of the lack of relevant standardized configurations and operating procedures, this expert task force has written this consensus statement in combination with relevant research and experience from China and abroad, with the aim of providing guidance for hospitals (institutions) and physicians intending to build a fluoroless cardiac EP Lab, implement relevant technologies, promote the standardized construction of the fluoroless cardiac EP Lab.


Assuntos
Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Cirurgia Assistida por Computador , Humanos , Eletrofisiologia Cardíaca , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
10.
Biol Pharm Bull ; 46(4): 524-532, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36696989

RESUMO

This study investigated whether pretreatment with puerarin could alleviate myocardial ischemia/reperfusion (I/R) injury in a cardiomyocyte oxygen-glucose deprivation and reoxygenation (OGD/R) model and in a mouse I/R injury model. For in vitro experiments, H9C2 cells were divided into control, erastin, OGD/R, OGD/R + puerarin, and OGD/R + ferrostatin (Fer)-1 groups. Parameters related to ferroptosis included levels of malondialdehyde (MDA), 4-hydroxynonenal (4-HNE), ATP, reactive oxygen species (ROS), glutathione (GSH), prostaglandin endoperoxide synthase (Ptgs) 2 mRNA, glutathione peroxidase (GPX) 4 protein and iron. In H9C2 cells, puerarin or Fer-1 pretreatment reduced ferroptosis, as indicated by decreased ROS and increased GSH, ATP levels. In vivo, wild-type mice were randomly divided into sham, I/R + vehicle, I/R + puerarin, and IR + Fer-1 groups. The I/R model was established by 30 min of left anterior descending artery occlusion followed by 24 h of reperfusion. Pretreatment with puerarin or Fer-1 significantly reduced infarct size in I/R mice, and decreased the activities of Myeloperoxidase (MPO) and cardiac enzymes such as creatine kinase MB isoenzyme (CK-MB), aspartate aminotransferase (AST), and lactate dehydrogenase (LDH) compared to those in the vehicle-treated group. Puerarin also reduced the production of MDA and 4-HNE, reduced the mRNA expression of Ptgs2 mRNA, and increased GPX4 protein expression. These results showed that puerarin exerted protective effects against myocardial I/R injury by inhibiting ferroptosis and inflammation, and therefore may have therapeutic potential for treatment of acute myocardial infarction.


Assuntos
Ferroptose , Traumatismo por Reperfusão Miocárdica , Traumatismo por Reperfusão , Camundongos , Animais , Traumatismo por Reperfusão Miocárdica/tratamento farmacológico , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Traumatismo por Reperfusão Miocárdica/metabolismo , Espécies Reativas de Oxigênio/metabolismo , Traumatismo por Reperfusão/tratamento farmacológico , Glutationa/metabolismo , RNA Mensageiro , Trifosfato de Adenosina
11.
Pediatr Surg Int ; 40(1): 24, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38127131

RESUMO

PURPOSE: To determine the prevalent microbiological profile of biliary atresia (BA) patients at the time of its occurrence by studying their intestinal flora. METHODS: A total of 118 gut microbiota samples from three groups of 43 BA patients, 33 disease controls (DC) with other cholestatic diseases and 42 healthy controls (HC), were analyzed by deep mining of public data. Subsequently, a total of 23 fecal samples from three groups of clinically collected patients (11 BA, 6 DC and 6 HC) were sequenced for 16S rRNA gene amplification and analyzed for serum butyrate (BU) level by liquid chromatography. RESULTS: Taxonomic analysis revealed significant differences in the composition of the intestinal microbiota between BA patients and controls, with a reduction in diversity and a higher abundance of Proteobacteria, Streptococcus and Lactobacillus in the BA group. Database and clinical data analyses concluded that Streptococcus/Bacteroides (AUC = 0.9035, 95% CI 0.8347-0.9722, P < 0.0001) or Streptococcus/Eggerthella (AUC = 0.8333, 95% CI 0.6340-1.000, P = 0.027) was the best microbiota to differentiate between BA and DC. Serum butyrate levels were low in the BA and DC groups and differed from the HC group (P = 0.01, P = 0.04). Butyrate levels in BA were negatively correlated with jaundice clearance and cholangitis, but not statistically significant. CONCLUSIONS: Our study reveals changes in the composition of the gut microbiota in BA, especially the butyrate-producing microbiota, and suggests the potential for using gut microbiota as a noninvasive diagnostic benefit for BA. Low levels of serum butyrate in BA may indicate a poor prognosis.


Assuntos
Atresia Biliar , Microbioma Gastrointestinal , Criança , Humanos , Microbioma Gastrointestinal/genética , Butiratos , Prognóstico , RNA Ribossômico 16S
12.
Molecules ; 28(3)2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36770930

RESUMO

A simple analytical method was developed and evaluated for the determination of two antifouling biocides using an ionic liquid-dispersive liquid-liquid micro-extraction (IL-DLLME) and a high-performance liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) analysis. Irgarol 1051 and Sea-Nine 211 were extracted from deionized water, lake water, and seawater using IL 1-hexyl-3-methylimidazolium hexafluorophosphate ([HMIm][PF6]) and ethyl acetate as the extraction solvent and the dispersion solvent. Several factors were considered, including the type and volume of extraction and dispersive solvent, IL amount, sample pH, salt effect, and cooling temperature. The developed method resulted in a recovery range of 78.7-90.3%, with a relative standard deviation (RSD, n = 3) less than 7.5%. The analytes were enriched greater than 40-fold, and the limits of detection (LOD) for two antifouling biocides were 0.01-0.1 µg L-1. The method was effectively applied for the analysis of real samples of freshwater as well as samples of seawater.

13.
Cardiovasc Diabetol ; 21(1): 229, 2022 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-36329456

RESUMO

BACKGROUND: The relationship between triglyceride-glucose (TyG) index, an emerging marker of insulin resistance, and the risk of incident heart failure (HF) was unclear. This study thus aimed to investigate this relationship. METHODS: Subjects without prevalent cardiovascular diseases from the prospective Kailuan cohort (recruited during 2006-2007) and a retrospective cohort of family medicine patients from Hong Kong (recruited during 2000-2003) were followed up until December 31st, 2019 for the outcome of incident HF. Separate adjusted hazard ratios (aHRs) summarizing the relationship between TyG index and HF risk in the two cohorts were combined using a random-effect meta-analysis. Additionally, a two-sample Mendelian randomization (MR) of published genome-wide association study data was performed to assess the causality of observed associations. RESULTS: In total, 95,996 and 19,345 subjects from the Kailuan and Hong Kong cohorts were analyzed, respectively, with 2,726 cases of incident HF in the former and 1,709 in the latter. Subjects in the highest quartile of TyG index had the highest risk of incident HF in both cohorts (Kailuan: aHR 1.23 (95% confidence interval: 1.09-1.39), PTrend <0.001; Hong Kong: aHR 1.21 (1.04-1.40), PTrend =0.007; both compared with the lowest quartile). Meta-analysis showed similar results (highest versus lowest quartile: HR 1.22 (1.11-1.34), P < 0.001). Findings from MR analysis, which included 47,309 cases and 930,014 controls, supported a causal relationship between higher TyG index and increased risk of HF (odds ratio 1.27 (1.15-1.40), P < 0.001). CONCLUSION: A higher TyG index is an independent and causal risk factor for incident HF in the general population. CLINICAL TRIAL REGISTRATION: URL: https://www.chictr.org.cn ; Unique identifier: ChiCTR-TNRC-11,001,489.


Assuntos
Glucose , Insuficiência Cardíaca , Humanos , Triglicerídeos , Análise da Randomização Mendeliana , Glicemia/análise , Estudos Retrospectivos , Estudos Prospectivos , Estudo de Associação Genômica Ampla , Fatores de Risco , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/genética , Biomarcadores
14.
BMC Cardiovasc Disord ; 22(1): 417, 2022 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-36123615

RESUMO

BACKGROUND: As a near-physiological pacing innovation, left bundle branch area pacing (LBBAP) has drawn much attention recently. This study was aimed to investigate the electrophysiological characteristics, unipolar/bipolar pacing parameters and mid- to long-term effects and safety of three different pacing methods and identify possible predictors of adverse left ventricular remodeling. METHODS: Ninety-two patients were divided into the LBBAP group, right ventricular septal pacing (RVSP) group and right ventricular apical pacing (RVAP) group. Baseline information, electrophysiological, pacing and echocardiographic parameters were collected. RESULTS: The three pacing methods were performed with a similar high success rate. The paced QRSd was significantly different among the LBBAP, RVSP and RVAP groups (105.93 ± 15.85 ms vs. 143.63 ± 14.71 ms vs. 155.39 ± 14.17 ms, p < 0.01). The stimulus to left ventricular activation time (Sti-LVAT) was the shortest in the LBBAP group, followed by the RVSP and RVAP groups (72.80 ± 12.07 ms vs. 86.29 ± 8.71 ms vs. 94.14 ± 10.14 ms, p < 0.001). LBBAP had a significantly lower tip impedance during the procedure and 3-month follow up as compared to RVSP and RVAP (p < 0.001). Higher bipolar captured thresholds were observed in LBBAP during the procedure (p < 0.001). Compared to the baseline values, there was a greater reduction in left ventricular end-diastolic dimension (LVEDD) in the LBBAP group (p = 0.046) and a significant enlargement in LVEDD in the RVAP group (p = 0.008). Multiple regression analysis revealed that the Sti-LVAT was a significant predictor of LVEDD at 12 months post-procedure. At the 24-h post-procedure, significant elevations were observed in the cTnI levels in LBBAP (p < 0.001) and RVSP (p < 0.05). More transient RBB injury was observed in LBBAP. But no significant difference was found in cardiac composite endpoints among three groups (p > 0.05). CONCLUSIONS: LBBAP demonstrated a stable captured threshold, a low tip impedance and a high R-wave amplitude during the 12-month follow-up. Left ventricular remodeling was improved at 12 months post-procedure through LBBAP. The Sti-LVAT was a significant predictor of left ventricular remodeling. LBBAP demonstrated its feasibility, effectiveness, safety and some beneficial electrophysiological characteristics during this mid- to long-term follow-up, which should be confirmed by further studies.


Assuntos
Fascículo Atrioventricular , Marca-Passo Artificial , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Humanos , Remodelação Ventricular
15.
Pacing Clin Electrophysiol ; 45(9): 1015-1023, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35767472

RESUMO

BACKGROUND: Cryoballoon ablation (CBA) is one of the most commonly used technologies designed for pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF), although the dosing of CBA remains controversial. We evaluated the long-term efficacy and safety of a novel individualized strategy of CBA compared to radiofrequency ablation (RFA) for patients with PAF. METHODS: In this observational study, symptomatic patients with drug-refractory paroxysmal AF were prospectively consented and enrolled in four centers, being assigned either to the CBA or RFA arm for ablation. In the CBA group, we used a time to isolation (TTI) - based dosing protocol. The primary endpoint was the recurrence of atrial arrhythmia >30 s following a 90-day blanking period. The secondary endpoint was procedure-related complications and procedure parameters. RESULTS: A total of 500 patients were recruited in either the CBA group (n = 247) or the RFA group (n = 253) between January 2017 and July 2018. After a median follow-up of 778 days, the atrial tachyarrhythmia-free survival was 71.7% in the CBA group and 67.0% in the RFA group. CBA and RFA displayed similar major or minor complication occurrence, while the former had a significantly shorter procedure duration (82.5 min vs. 141.1 min, p < .001) and left atrial dwell time (60.1 min vs. 109.9 min, p < .001) but longer fluoroscopy exposure (13.8 min vs. 8.1 min, p < .001). CONCLUSION: Compared to RFA, our TTI-based CBA dosing protocol showed comparable efficacy and safety, with a significantly reduced procedure duration in patients with PAF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Ablação por Cateter/métodos , Criocirurgia/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
16.
Pacing Clin Electrophysiol ; 45(8): 975-983, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35363390

RESUMO

BACKGROUND: Pre-excited atrial fibrillation (AF) is associated with increased risk of life-threatening events. However, at times, patients with pre-excited AF still repetitively suffer from hemodynamic disturbance, with resistance to acute treatments of antiarrhythmic therapy and cardioversion. METHODS: To evaluate the feasibility in correcting hemodynamic disturbance, patients with pre-excited AF who underwent catheter ablation of accessory pathway as an emergency procedure, were retrospectively collected from two centers of China. The medical records of patients were analyzed and summarized in this case series. RESULTS: Five patients with pre-excited AF who received emergency catheter ablation of accessory pathway, were collected from two contributor centers and reported in this case series. All collected patients still repetitively suffered from hemodynamic disturbance induced by rapid anterograde conduction of AF via pathway, even guideline recommended acute interventions of intravenous antiarrhythmic therapy and cardioversion had been performed. Finally, as an emergency procedure, catheter ablation of accessory pathway was performed in collected patients. Correspondingly, the hemodynamic unstable status was greatly relieved. Meanwhile, all collected patients with high risk of pre-excited AF were combined with left-sided accessory pathway, with shortest RR interval of widened pre-excited QRS complex less than 250 ms. Thus, combination with left-sided pathway is proposed as an indicator for the increased risk of life-threatening events in patients with high risk of pre-excited AF. CONCLUSIONS: Emergency catheter ablation of accessory pathway is an effective option for the acute managements of patients with high risk of pre-excited AF in unstable hemodynamics, which is resistant to antiarrhythmic therapy and cardioversion.


Assuntos
Feixe Acessório Atrioventricular , Fibrilação Atrial , Ablação por Cateter , Síndromes de Pré-Excitação , Síndrome de Wolff-Parkinson-White , Feixe Acessório Atrioventricular/cirurgia , Antiarrítmicos , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Humanos , Síndromes de Pré-Excitação/cirurgia , Estudos Retrospectivos
17.
Pacing Clin Electrophysiol ; 45(10): 1186-1193, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35939332

RESUMO

BACKGROUND: Ablation index (AI) is a novel technology of ablation lesion quality to help improve homogeneity of lesion size and continuity. In this study, we aim to evaluate whether AI-guided PVI improves clinical outcomes compared to CF-guided PVI in patients with paroxysmal AF (PAF). METHODS: Patients undergoing first-time radiofrequency ablation for PAF were randomized in a 2:1 ratio to two groups: AI-guided PVI and CF-guided PVI. In the AI group, AI ≥500 was recommended at the anterior/superior/inferior walls, 350-400 at the posterior wall, and inter-lesion distance ≤4 mm. The primary endpoint is the freedom from atrial arrhythmia recurrence during 12 months follow-up, without antiarrhythmic drug therapy (ADT). The key secondary endpoints include intra-procedural efficiency and peri-procedural complications. RESULTS: Two hundred twenty five patients were randomized (AI group [n = 149] and CF group [n = 76]). First-pass isolation rate in AI group was significantly higher than that in CF group (58.3% vs. 43.4%, p = .035). After a median follow-up of 12.2 months, 154/225 (68.4%) of patients were free from atrial arrhythmia recurrence without ADT, which was higher in AI group compared with CF group, but without significant difference (71.1% vs. 63.2%, p = .253). The incidence of peri-procedural complications is low and without difference between two groups. CONCLUSIONS: AI-guided ablation provided higher acute efficacy than CF-guided ablation in PV isolation for patients with paroxysmal AF. The long-term success rate in AI group was higher than CF group, but did not reach statistical significance.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Ablação por Radiofrequência , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Antiarrítmicos , Resultado do Tratamento , Recidiva
18.
Nutr Metab Cardiovasc Dis ; 32(6): 1519-1527, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35428542

RESUMO

BACKGROUND AND AIMS: This study aimed to investigate the role of C-reactive protein (CRP) in atrial fibrillation (AF) from epidemiological and genetic perspectives. METHODS AND RESULTS: Individual-level data from the Kailuan cohort recruited between 2006 and 2017 were included. Serum CRP levels were measured at baseline and at biennial follow-up visits, and incident AF was ascertained from biennial 12-lead ECG assessment and medical records. Cox proportional hazards models were used to assess the association between baseline CRP levels or cumulative exposure to CRP and incident AF. A meta-analysis including nine prospective cohort studies and our current study was also conducted. Mendelian randomization (MR) analysis was performed to evaluate the aetiological role of CRP in AF. In our observational study (n = 86,424), high baseline CRP levels (>3 mg/L), compared with low CRP (<1 mg/L), were not significantly associated with AF risk (HR: 1.18; 95% CI: 0.99-1.40). High cumulative exposure to CRP (HR: 1.49; 95%CI: 1.01-2.21) was significantly associated with an increased risk of AF. Our meta-analysis suggested a positive association between elevated CRP levels and incident AF (relative risk: 1.27; 95% CI: 1.14-1.42). However, no significant association between genetically determined CRP and AF risk was observed in the MR analysis. CONCLUSION: Evidence from observational studies suggested that elevated serum CRP levels were positively associated with incident AF, while the causal effects of CRP on AF were not supported by the MR analysis. CLINICAL TRIAL REGISTRATION: URL: https://www.chictr.org.cn; Unique identifier: ChiCTR-TNRC-11001489.


Assuntos
Fibrilação Atrial , Proteína C-Reativa , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/genética , Proteína C-Reativa/metabolismo , Incidência , Análise da Randomização Mendeliana , Estudos Observacionais como Assunto , Estudos Prospectivos , Fatores de Risco
19.
Herz ; 47(1): 63-66, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33890136

RESUMO

AIMS: Pocket hematoma is a common complication associated with cardiac device implantation, but there are limited strategies to deal with this problem. We aimed to evaluate the effectiveness of sub-pocket small-hole drainage (SSD) as a new way to manage severe pocket hematoma. METHODS: A total of 11 patients with severe pocket hematoma were selected for this case series study. The SSD procedure was performed and wound healing was monitored. RESULTS: The SSD procedure was successfully performed on all 11 patients. The time window for SSD was 10-14 days (mean 12.0 ± 1.3 days) after cardiac device implantation. On average, 18.3 ± 2.3 ml of hematoma was drained , with a mean procedural time of 21.3 ± 2.6 min. The patients were followed up for 4-12 months and all pockets healed well, without any complications such as pocket infection, bleeding, device exposure, and electrode fracture. CONCLUSION: Sub-pocket small-hole drainage is an alternative approach for dealing with severe pocket hematoma after cardiac device implantation.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Desfibriladores Implantáveis/efeitos adversos , Drenagem , Hematoma/diagnóstico por imagem , Hematoma/etiologia , Hematoma/cirurgia , Humanos , Marca-Passo Artificial/efeitos adversos , Fatores de Risco
20.
Pediatr Surg Int ; 39(1): 46, 2022 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-36502451

RESUMO

PURPOSE: The efficacy of robot-assisted hepaticojejunostomy (RAHJ) and laparoscopic-assisted hepaticojejunostomy (LAHJ) in children with congenital choledochal dilatation has been a topic of much debate and controversy. The purpose of this study was to evaluate the role of RAHJ and LAHJ in pediatric congenital choledochal dilatation. METHOD: The review program has been prospectively registered (PROSPEROID: CRD42022306868). We searched the PubMed, Embase, Cochrane, CBM, VIP, Web of Science, CNKI databases, and Wanfang databases from March 2021. The Mantel-Haenszel method and a random-effects model were used to figure out the hazard ratio (95% CI). RESULTS: Ten studies evaluated eight hundred and sixty-nine subjects (three hundred and thirty-two in the robotic group and five hundred and thirty-seven in the laparoscopic group), meeting all inclusion criteria. Compared with the laparoscopic group, robotic group demonstrated fewer postoperative complications [p = 0.0009; OR = 0.34 (95% CI, 0.18-0.64); I2 = 3%], shorter postoperative hospital stay [p < 00,001; MD = - 2.05 (95% CI, - 2.40-1.70); I2 = 0%], and less intraoperative bleeding [p = 0.008; MD = - 10.80 (95% CI, - 18.80-2.81); I2 = 99%]. There was no significant difference in operative time between the two groups [p = 0.10; MD = 24.53 (95% CI, - 5.11-54.17); I2 = 99%]. The same situation happened in short-term complication outcomes [p = 0.06; RR = 0.45 (95% CI, 0.19-1.04); I2 = 0%]. However, children in the RAHJ group had significantly lower levels of long-term complications [p = 0.04; OR = 0.41 (95% CI, 0.17-0.96); I2 = 0%]. Hospitalization costs were significantly higher in the RAHJ group [p < 0.00001; OR = 27,113.86 (95% CI, 26,307.24-27,920.48); I2 = 0%]. For overall complications, subgroup analysis of literature published after 2020 and of literature with high quality scores showed a significant decrease in the RAHJ group. CONCLUSION: In children with congenital choledochal dilatation, RAHJ is associated with reduced intraoperative bleeding, postoperative complications, and length of stay. Robotic surgery has a bright future in the treatment of pediatric common hepatic duct cysts and deserves to be promoted and popularized.


Assuntos
Procedimentos Cirúrgicos do Sistema Biliar , Cisto do Colédoco , Laparoscopia , Robótica , Criança , Humanos , Cisto do Colédoco/cirurgia , Procedimentos Cirúrgicos do Sistema Biliar/métodos , Laparoscopia/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA