Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Phys Rev Lett ; 132(12): 121902, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38579200

RESUMO

We report the measurement of the helicity asymmetry E for the pπ^{0} and nπ^{+} final states using, for the first time, an elliptically polarized photon beam in combination with a longitudinally polarized target at the Crystal Ball experiment at MAMI. The results agree very well with data that were taken with a circularly polarized photon beam, showing that it is possible to simultaneously measure polarization observables that require linearly (e.g., G) and circularly polarized photons (e.g., E) and a longitudinally polarized target. The new data cover a photon energy range 270-1400 MeV for the pπ^{0} final state (230-842 MeV for the nπ^{+} final state) and the full range of pion polar angles, θ, providing the most precise measurement of the observable E. A moment analysis gives a clear observation of the pη cusp in the pπ^{0} final state.

2.
Diagn Microbiol Infect Dis ; 109(4): 116310, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38776662

RESUMO

Haematospirillum jordaniae is a gram-negative bacterium that has been identified in the blood of septic patients. The environmental source or potential zoonotic host of this bacterium, recently described as a human bacterial pathogen is unknown. An increasing number of H. jordaniae clinical infections identified by our laboratory suggested the need for an assay to detect this organism in order to aid clinical teams and practitioners with faster identification and treatment thus improving patient prognosis. Described here is a real-time qualitative PCR assay designed using gene targets identified from the analysis of 14 H. jordaniae genomes sequenced by the Center for Disease Control and Prevention's (CDC) Special Bacterial Reference Laboratory (SBRL) culture collection. The assay was validated on clinical EDTA whole blood samples as well as on plasma and determined to be effective at detecting as few as 10 copies per microliter (10,000 copies per mL, 4 log/mL) for whole blood samples and 1 copy per microliter (1,000 copies per mL, 3 log mL) for plasma samples.


Assuntos
Infecções por Bactérias Gram-Negativas , Reação em Cadeia da Polimerase em Tempo Real , Humanos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Infecções por Bactérias Gram-Negativas/diagnóstico , Infecções por Bactérias Gram-Negativas/microbiologia , Infecções por Bactérias Gram-Negativas/sangue , Plasma/microbiologia , Sensibilidade e Especificidade , Ácido Edético , Sangue/microbiologia , DNA Bacteriano/genética , DNA Bacteriano/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA