Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Opt Lett ; 49(8): 1933-1936, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38621044

RESUMO

Low phase noise and narrow linewidth lasers are achieved by implementing self-injection locking of a DFB laser on two distinct fiber Fabry-Perot resonators. More than 45 dB improvement of the laser phase or frequency noise is observed when the laser is locked. In both cases, a frequency noise floor below 1 Hz2/Hz is measured. The integrated linewidth of the best of the two lasers is computed to be in the range of 400 Hz and appears to be dominated by vibration noise close to the carrier. The results are then compared with a model based on the retro-injected power and the Q factors ratio between the DFB laser and the resonator. This straightforward model facilitates the extraction of the theoretical performance of these sources close to the carrier, a characteristic still hidden by vibration noise.

3.
Opt Lett ; 49(11): 3214-3217, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38824366

RESUMO

We report a theoretical and experimental investigation of fiber Fabry-Perot cavities aimed at enhancing Kerr frequency comb generation. The modulation instability (MI) power threshold is derived from the linear stability analysis of a generalized Lugiato-Lefever equation. By combining this analysis with the concepts of power enhancement factor (PEF) and optimal coupling, we predict the ideal manufacturing parameters of fiber Fabry-Perot (FFP) cavities for the MI Kerr frequency comb generation. Our findings reveal a distinction between the optimal coupling for modulation instability and that of the cold cavity. Consequently, mirror reflectivity must be adjusted to suit the specific application. We verified the predictions of our theory by measuring the MI power threshold as a function of detuning for three different cavities.

4.
Opt Lett ; 48(22): 5955-5958, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37966761

RESUMO

We report an experimental investigation on the impact of the pump pulse duration on the modulation instability process in fiber Fabry-Pérot resonators. We demonstrate that cross-phase modulation between the forward and the backward waves alters significantly the modulation instability process. By varying the pump pulse duration, we show the modification of the modulation instability threshold and frequency. These experimental observations are in excellent agreement with theoretical predictions.

5.
Opt Lett ; 48(2): 275-278, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36638436

RESUMO

We report the experimental observation of a modulation instability induced Kerr frequency comb in an all fiber Fabry-Pérot resonator. We fully characterized, in intensity and phase, the frequency comb using a commercial 10 MHz resolution heterodyne detection system to reveal more than 125 comb teeth within each of the modulation instability sidelobes. Moreover, we were able to reveal the fine temporal structure in phase and intensity of the output Turing patterns. The experimental results are generally in good agreement with numerical simulations.

6.
Opt Lett ; 37(4): 518-20, 2012 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-22344092

RESUMO

Nonlinear phenomena occurring in an optical fiber ring resonator featuring ultrahigh Q factor are experimentally studied. The laser is locked onto the resonator, and the optical power induced in the resonator is controlled. The onset of the first stimulated Brillouin scattering wave occurs at an optical input power as low as -9 dBm in these resonators. When the resonator is used as the frequency reference device in an optoelectronic oscillator (OEO), it has been found that these parasitic signals mix with the OEO signal and degrade its phase noise. More than 20 dB improvement of the OEO phase noise has been demonstrated by limiting these nonlinear optical effects.

7.
Appl Opt ; 51(20): 4742-8, 2012 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-22781250

RESUMO

Optical Q factor measurements are performed on a whispering gallery mode (WGM) disk resonator using a microwave frequency domain approach instead of using an optical domain approach. An absence of hysteretic behavior and a better linearity are obtained when performing linewidth measurements by using a microwave modulation for scanning the resonances instead of the piezoelectric-based frequency tuning capability of the laser. The WGM resonator is then used to stabilize a microwave optoelectronic oscillator. The microwave output of this system generates a 12.48 GHz signal with -94 dBc/Hz phase noise at 10 kHz offset.

8.
IEEE Trans Ultrason Ferroelectr Freq Control ; 67(12): 2750-2756, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32924939

RESUMO

A 1-GHz full cryogenic oscillator is presented. The oscillator is based on a planar superconductor resonator featuring a loaded Q factor of 200 000 at low microwave input power (unloaded Q of 400 000) and on amplifying parts realized with SiGe bipolar transistors. The circuit is designed with a harmonic balance software and realized on an alumina substrate. A nonlinear model is extracted at low temperature both for the transistor and the resonator. This double nonlinearity increases the difficulty of the oscillator design and implies a strategy to limit the power inside the resonator. The vibrations of the cryogenerator are also a serious issue to get high performance. Finally, the oscillator features a phase noise of -112 dBc/Hz at 100-Hz offset frequency and a phase noise floor of -170 dBc/Hz (100-kHz offset) at a temperature of 65 K.

9.
Biomed Opt Express ; 10(11): 5862-5876, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31799052

RESUMO

This work describes the implementation of a compact system allowing measurement of blood flow velocity using laser Doppler velocimetry in situ. The compact setup uses an optical fiber acting as an emitter and receptor of the signal. The signal is then recovered by a photodiode and processed using a spectrum analyzer. The prototype was successfully tested to measure microbead suspension and whole blood flow velocities in a fluidic chip. Fibers with hemispherical lenses with three different radius of curvature were investigated. This simple yet precise setup would enable the insertion of the fiber via a medical catheter to monitor blood flow velocity in non superficial vessels where previous reported techniques cannot be implemented.

10.
Artigo em Inglês | MEDLINE | ID: mdl-17091834

RESUMO

Phase noise of micromachined bulk acoustic wave resonators is investigated. A measurement bench, able to characterize the phase noise of a single resonator on-wafer, is set up. The experimental data demonstrate the existence of a 1/f phase noise component, the amplitude of which is strongly dependent on the resonator geometry. Particularly, the apodized resonators have shown the best phase noise performance, with no degradation of the Q factor.

11.
Sci Rep ; 6: 27208, 2016 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-27251460

RESUMO

A microwave domain characterization approach is proposed to determine the properties of high quality factor optical resonators. This approach features a very high precision in frequency and aims to acquire a full knowledge of the complex transfer function (amplitude and phase) characterizing an optical resonator using a microwave vector network analyzer. It is able to discriminate between the different coupling regimes, from the under-coupling to the selective amplification, and it is used together with a model from which the main resonator parameters are extracted, i.e. coupling factor, intrinsic losses, phase slope, intrinsic and external quality factor.

12.
Artigo em Inglês | MEDLINE | ID: mdl-14995014

RESUMO

In this paper, the electrical and noise performances of a 0.8 microm silicon germanium (SiGe) transistor optimized for the design of low phase-noise circuits are described. A nonlinear model developed for the transistor and its use for the design of a low-phase noise C band sapphire resonator oscillator are also reported. The best measured phase noise (at ambient temperature) is -138 dBc/Hz at 1 kHz offset from a 4.85 GHz carrier frequency, with a loaded QL factor of 75,000.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA