Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Int J Clin Pract ; 75(6): e14153, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33735532

RESUMO

BACKGROUND: Red cell distribution width (RDW) is recently emerging as a prognostic indicator in many cardiovascular diseases. However, less is known about its predictive role in patients undergoing transcatheter aortic valve implantation (TAVI). METHODS: We retrospectively included very high-risk patients with severe aortic valve stenosis undergoing TAVI between February 2012 and December 2019. Patients were classified according to RDW tertiles. Our primary endpoint was long-term all-cause mortality. The secondary endpoint was a composite of in-hospital major adverse events as defined by the Valve Academic Research Consortium 2 criteria and/or long-term all-cause mortality. RESULTS: A total of 424 patients [median age 83.5 years, 52.6% females] were analysed. After a median follow-up of 1.55 years, all-cause mortality was 25.5%. At the multivariate-adjusted Cox regression analysis, patients in the highest RDW tertile were associated with a higher risk for all-cause mortality [hazard ratio [HR] 1.73, 95%confidence interval [CI] 1.02-2.95] compared with the lowest tertile. When considering RDW as a continuous variable, we found an 11% increased risk in overall mortality [HR 1.11, 95% CI 1.00-1.24] for each increased point in RDW. The highest RDW tertile was also independently associated with the occurrence of the composite endpoint [odds ratio [OR] 2.10, 95% CI 1.17-3.76] compared with lower tertiles. CONCLUSIONS: In our cohort, elevated basal RDW values were independent predictors of increased long-term mortality and higher rate of in-hospital adverse events. The inclusion of a routinely available biomarker as RDW, may help the pre-operative risk assessment in potential TAVI candidates and optimise their management.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Índices de Eritrócitos , Eritrócitos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Vasc Endovascular Surg ; 57(8): 949-953, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37309678

RESUMO

PURPOSE: Abdominal aortic aneurysms (AAA) are observed in 6% of patients with concomitant aortic valve stenosis (AS) requiring aortic valve replacement. Optimal management of these concomitant pathologies is still debated. CASE REPORT: An 80-year-old man presented with acute heart failure due to a severe AS. Past medical history included AAA under regular surveillance. A thoracic and abdominal computed tomography angiography (CTA) confirmed a 6 mm increase of AAA over an 8-month period (max 55 mm). A multidisciplinary team prescribed a simultaneous endovascular approach of transcatheter aortic valve implantation (TAVI) followed by endovascular aneurysm repair (EVAR) under local anaesthesia with bilateral femoral percutaneous access. No intra or post-procedural complications were registered; technical success was confirmed by completion angiography and post-operative ultrasound. The patient was discharged on postoperative day 5. A 2-month post-operative CTA confirmed ongoing technical success. CONCLUSION: Combined TAVI and EVAR under local anaesthesia for AS and AAA was associated with reduced hospital stay and technical success at 2 months from intervention in this case report.


Assuntos
Aneurisma da Aorta Abdominal , Estenose da Valva Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Humanos , Masculino , Anestesia Local , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Valva Aórtica , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Implante de Prótese Vascular/métodos , Correção Endovascular de Aneurisma , Procedimentos Endovasculares/métodos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
3.
Front Cardiovasc Med ; 10: 1188644, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37711555

RESUMO

Background: Coronary artery disease (CAD) is common in patients with aortic valve stenosis (AS) ranging from 60% to 80%. The clinical and prognostic role of coronary artery lesions in patients undergoing Transcatheter Aortic Valve Implantation (TAVI) remains unclear. The aim of the present observational study was to estimate long-term clinical outcomes by Quantitative Flow Ratio (QFR) characterization of CAD in a well-represented cohort of patients affected by severe AS treated by TAVI. Methods: A total of 439 invasive coronary angiographies of patients deemed eligible for TAVI by local Heart Teams with symptomatic severe AS were retrospectively screened for QFR analysis. The primary endpoint of the study was all-cause mortality. The secondary endpoint was a composite of cardiovascular mortality, stroke/transient ischemic attack (TIA), acute myocardial infarction (AMI), and any hospitalization after TAVI. Results: After exclusion of patients with no follow-up data, coronary angiography not feasible for QFR analysis and previous surgical myocardial revascularization (CABG) 48/239 (20.1%) patients had a QFR value lower or equal to 0.80 (QFR + value), while the remaining 191/239 (79.9%) did not present any vessel with a QFR positive value. In the adjusted Cox regression analysis, patients with positive QFR were independently associated with an increased risk of all-casual mortality (Model 1, HR 3.47, 95% CI, 2.35-5.12; Model 2, HR 5.01, 95% CI, 3.17-7.90). In the adjusted covariate analysis, QFR+ involving LAD (37/48, 77,1%) was associated with the higher risk of the composite outcome compared to patients without any positive value of QFR or non-LAD QFR positive value (11/48, 22.9%). Conclusions: Pre-TAVI QFR analysis can be used for a safe, simple, wireless functional assessment of CAD. QFR permits to identify patients at high risk of cardiovascular mortality or MACE, and it could be considered by local Heart Teams.

4.
G Ital Cardiol (Rome) ; 22(9 Suppl 1): 43S-44S, 2021 09.
Artigo em Italiano | MEDLINE | ID: mdl-34590624

RESUMO

A 79-year-old woman was admitted to our coronary care unit for non-ST-elevation myocardial infarction. Urgent left transradial coronary angiography showed mid-distal high-grade stenosis of the left circumflex coronary artery. During percutaneous coronary intervention, stent dislodgement from the balloon catheter occurred. Fortunately, the guidewire was left in place through the detached stent, but a loop snare failed to cross the proximal circumflex artery. A second wire was placed in parallel to the first one and the first wire was caught in the loop snare, which was pulled back and closed at the level of the stent. Then, we cautiously pulled the guiding catheter together with the stent as a whole unit out of the introducer.


Assuntos
Angioplastia Coronária com Balão , Idoso , Angiografia Coronária , Vasos Coronários , Feminino , Humanos , Stents , Resultado do Tratamento
5.
G Ital Cardiol (Rome) ; 22(11): 944-949, 2021 11.
Artigo em Italiano | MEDLINE | ID: mdl-34709235

RESUMO

BACKGROUND: Kounis syndrome is a hypersensitivity coronary disorder induced by exposure to several triggers; the most common are antibiotics, followed by insect bites. METHODS: We reviewed the literature and identified 66 patients who experienced acute coronary syndrome after insect bites. RESULTS: The median age was 51 years, and 19.0% were women and only 12% had a history of allergy. The most involved insects were bee and wasp (86%) and the most frequent clinical manifestations were chest pain and anaphylaxis (36% and 29%, respectively). ST-segment elevation was the most common electrocardiographic finding (>70%). There was a not negligible rate of complications (15%), with a possible increased arrhythmic burden in patients without significant coronary atherosclerosis. CONCLUSIONS: Acute coronary syndrome after insect bites is not so rare and it could have serious complications, with a possible increased arrhythmic burden in patients without significant coronary atherosclerosis.


Assuntos
Síndrome Coronariana Aguda , Anafilaxia , Mordeduras e Picadas de Insetos , Síndrome de Kounis , Síndrome Coronariana Aguda/epidemiologia , Síndrome Coronariana Aguda/etiologia , Anafilaxia/diagnóstico , Anafilaxia/epidemiologia , Anafilaxia/etiologia , Animais , Abelhas , Eletrocardiografia , Humanos , Mordeduras e Picadas de Insetos/complicações
7.
G Ital Cardiol (Rome) ; 18(2 Suppl 1): 9S-18S, 2017 Feb.
Artigo em Italiano | MEDLINE | ID: mdl-28398396

RESUMO

BACKGROUND: The bioresorbable vascular scaffold (BRS) technology constitutes the new revolution of the coronary artery disease interventional treatment. Currently, three distinct types of BRSs are available but only one, the Absorb BVS, was on the market in 2013 when the Regional Commission for Medical Devices and the Cardiology and Cardiac Surgery Commission of the Emilia-Romagna Region drew up a technical and scientific essay to provide guidance for the introduction of BRS in public and affiliated health facilities. Five preferential indications were given for use: long coronary lesions (>28 mm), ostial lesions (left main stem excluded), complete revascularization in patients aged <50 years, diffuse disease (>40 mm) or involving the mid/distal left anterior descending (LAD) branch in patients <70 years, spontaneous coronary artery dissection. METHODS: This survey analyzed data from all the catheterization laboratories in the Emilia-Romagna Region, merged in a unified database. RESULTS: In a 3-year study period, 546 BRS were implanted in 328 patients, corresponding to 1.5% of the drug-eluting stents (DES) used, with a trend towards a progressive increase over time. Initial indications were followed in 200/328 (61.0%) patients (about one third fitting more indications), mainly for treatment of long lesions in vessels >2.5 mm (67%), young patients (31.5%) and mid/distal LAD (28%). In 22.6% of cases the clinical scenario was a ST-segment elevation myocardial infarction, in 39.3% a non-ST-segment elevation acute coronary syndrome. Intracoronary imaging was infrequently used (intravascular ultrasound in 24.7% of cases). In 85 patients (25.9%) a hybrid procedure (BVS/DES) was performed. CONCLUSIONS: BRS use has resulted lower than expected, with discrete variability among centers, but according to the initial indications of the Emilia-Romagna Region in the majority of cases. The underuse might have been due to operators' caution in their initial experience. However, the increasing trend may reveal a greater confidence in the implantation technique and the whole amount of safety and efficacy data.


Assuntos
Implantes Absorvíveis , Prótese Vascular , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/cirurgia , Alicerces Teciduais , Humanos , Itália , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA