Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Int J Cardiol ; 299: 49-55, 2020 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-31378382

RESUMO

BACKGROUND: Coronary Aneurysms are a focal dilatation of an artery segment >1.5-fold the normal size of adjacent segments. Although some series have suggested a prevalence of 0.3-12%, data are lacking. In addition, they are not mentioned in practice guidelines. Our aim was investigate its prevalence, management and long-term outcomes. METHODS AND RESULTS: The coronary artery aneurysm registry (CAAR) involved 32 hospitals across 9 countries in America and Europe. We reviewed 436,467 consecutive angiograms performed over the period 2004-2016. Finally, 1565 patients were recruited. Aneurysm global prevalence was 0.35%. Most patients were male (78.5%) with a mean age of 65 years and frequent cardiovascular risk factors. The main indication for angiogram was an acute coronary syndrome, 966 cases. The number of aneurisms was ≤2 per patient in 95.8% of the cases, mostly saccular, most frequently found in the left anterior descending and with numbers proportional with coronary stenosis. Aortopathies were related with more aneurysms too. Most patients received any revascularization procedure (69%), commonly percutaneous (53%). After a median follow-up of 37.2 months, 485 suffered a combined event (MACE) and 240 died. Without major differences comparing CABG vs PCI, MACE and death were more frequent in patients who received bare metal stents. CONCLUSIONS: Coronary artery aneurysms are not uncommon. Usually, they are associated with coronary stenosis and high cardiovascular risk. Antiplatelet therapy seems reasonable and a percutaneous approach is safe and effective.


Assuntos
Aneurisma Coronário/diagnóstico por imagem , Aneurisma Coronário/terapia , Internacionalidade , Sistema de Registros , Idoso , Aneurisma Coronário/epidemiologia , Angiografia Coronária/métodos , Angiografia Coronária/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Inibidores da Agregação Plaquetária/uso terapêutico
2.
SAGE Open Med ; 7: 2050312119828261, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30783525

RESUMO

BACKGROUND: We performed a meta-analysis to evaluate the benefit of patent foramen ovale closure in stroke prevention. METHODS: We searched Medline/PubMed, EMBASE, Web of Science and Cochrane central database for randomized control trials assessing the incidence of recurrent stroke after patent foramen ovale closure when compared to medical therapy. Pooled odds ratio and 95% confidence intervals were calculated using a random effects model. The heterogeneity among studies was tested using the χ2 test and inconsistency was quantified using the I2 statistic. RESULTS: Our search strategy yielded 71 articles. We included five studies with a total of 3440 patients. Median age in the device group was 45 (43, 5.5) years and in the medical group was 45 (44.5, 46) years; 52% were male, 27.7% of patients had an atrial septal aneurysm, 25% had hypertension, and 20.5% had diabetes mellitus. The median follow-up time was 44 (34.5-50) months. The pooled odds ratio of recurrent stroke, transient ischemic attack and composite end point of stroke + transient ischemic attack + peripheral embolism in the patent foramen ovale closure versus medical therapy group were 0.4 (95% confidence interval 0.25-0.63, I2 = 57.5%), 0.93 (95% confidence interval 0.61-1.42, I2 = 0%), and 0.6 (95% confidence interval 0.44-0.82, I2 = 0%), respectively. The incidence of atrial fibrillation was found to be significantly higher in the patent foramen ovale closure group with odds ratio of 6 (95% confidence interval 3.13-11.4, I2 = 33.5%). On subgroup analysis, patent foramen ovale closure appeared to benefit males and patients with a large shunt. Number needed to treat to prevent one recurrent stroke with patent foramen ovale closure is 42. Number needed to harm to cause one atrial fibrillation with patent foramen ovale closure is 39. CONCLUSION: This meta-analysis of randomized trials concludes that percutaneous patent foramen ovale closure is effective in recurrent stroke prevention especially in males and in those with a large shunt.

3.
J Clin Med ; 7(1)2018 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-29315259

RESUMO

Peripheral arterial disease (PAD) refers to partial or complete occlusion of one or more non-coronary arteries that leads to compromised blood flow and ischemia. Numerous processes are involved in arterial stenosis, however, atherosclerosis remains the most common etiology. PAD constitutes a major health economic problem, and it is estimated that over 200 million people around the world suffer from PAD, with at least 20% having some degree of claudication. The purpose of this review is to compare and contrast the guidelines on PAD published in 2005, 2011 and 2016 in terms of new recommendations and level of evidence for practicing clinicians.

6.
Clin Cardiol ; 40(8): 580-585, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28337781

RESUMO

Coronary artery aneurysm is defined as a coronary dilation that exceeds the diameter of adjacent segments or the diameter of the patient's largest normal coronary vessel by 1.5×. It is an uncommon disease that has been diagnosed with increasing frequency since the widespread appearance of coronary angiography. The published incidence varies from 1.5% to 5%, suggesting male dominance and a predilection for the right coronary artery. Although several causes have been described, atherosclerosis accounts for ≥50% of coronary aneurysms in adults. Reported complications include thrombosis and distal embolization, rupture, and vasospasm, causing ischemia, heart failure, or arrhythmias. The natural history and prognosis remain unknown, as definitive data are scarce. Controversies persist regarding the use of medical management (antithrombotic therapy) or interventional/surgical procedures. Only some case reports or small case series are available about this condition. The Coronary Artery Aneurysm Registry (CAAR; http://www.ClinicalTrials.gov NCT02563626) is a multicenter international ambispective registry that aims to provide insights on anatomic, epidemiologic, and clinical aspects of this substantially unknown entity. In addition, the registry will assess management strategies (conservative, interventional, or surgical) and their short- and long-term results in a large cohort of patients. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov. Unique identifier: NCT02563626.


Assuntos
Comportamento Cooperativo , Aneurisma Coronário , Cooperação Internacional , Sistema de Registros , Projetos de Pesquisa , Aneurisma Coronário/diagnóstico por imagem , Aneurisma Coronário/epidemiologia , Aneurisma Coronário/terapia , Angiografia Coronária , Cuba , Europa (Continente) , Humanos , Valor Preditivo dos Testes , Prognóstico , Fatores de Risco , Fatores de Tempo , Estados Unidos , Uruguai
7.
Ann Card Anaesth ; 19(Supplement): S6-S11, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27762242

RESUMO

BACKGROUND: The surgical and procedural specialties are continually evolving their methods to include more complex and technically difficult cases. These cases can be longer and incorporate multiple teams in a different model of operating room synergy. Patients are frequently older, with comorbidities adding to the complexity of these cases. Recording of this environment has become more feasible recently with advancement in video and audio capture systems often used in the simulation realm. AIMS: We began using live capture to record a new procedure shortly after starting these cases in our institution. This has provided continued assessment and evaluation of live procedures. The goal of this was to improve human factors and situational challenges by review and debriefing. SETTING AND DESIGN: B-Line Medical's LiveCapture video system was used to record successive transcatheter aortic valve replacement (TAVR) procedures in our cardiac catheterization/laboratory. An illustrative case is used to discuss analysis and debriefing of the case using this system. RESULTS AND CONCLUSIONS: An illustrative case is presented that resulted in long-term changes to our approach of these cases. The video capture documented rare events during one of our TAVR procedures. Analysis and debriefing led to definitive changes in our practice. While there are hurdles to the use of this technology in every institution, the role for the ongoing use of video capture, analysis, and debriefing may play an important role in the future of patient safety and human factors analysis in the operating environment.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Gravação de Videoteipe , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Feminino , Humanos , Tempo de Internação , Salas Cirúrgicas , Segurança do Paciente , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA