Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 33(3): 1629-1640, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36323984

RESUMO

OBJECTIVES: To compare the image quality and hepatic metastasis detection of low-dose deep learning image reconstruction (DLIR) with full-dose filtered back projection (FBP)/iterative reconstruction (IR). METHODS: A contrast-detail phantom consisting of low-contrast objects was scanned at five CT dose index levels (10, 6, 3, 2, and 1 mGy). A total of 154 participants with 305 hepatic lesions who underwent abdominal CT were enrolled in a prospective non-inferiority trial with a three-arm design based on phantom results. Data sets with full dosage (13.6 mGy) and low dosages (9.5, 6.8, or 4.1 mGy) were acquired from two consecutive portal venous acquisitions, respectively. All images were reconstructed with FBP (reference), IR (control), and DLIR (test). Eleven readers evaluated phantom data sets for object detectability using a two-alternative forced-choice approach. Non-inferiority analyses were performed to interpret the differences in image quality and metastasis detection of low-dose DLIR relative to full-dose FBP/IR. RESULTS: The phantom experiment showed the dose reduction potential from DLIR was up to 57% based on the reference FBP dose index. Radiation decreases of 30% and 50% resulted in non-inferior image quality and hepatic metastasis detection with DLIR compared to full-dose FBP/IR. Radiation reduction of 70% by DLIR performed inferiorly in detecting small metastases (< 1 cm) compared to full-dose FBP (difference: -0.112; 95% confidence interval [CI]: -0.178 to 0.047) and full-dose IR (difference: -0.123; 95% CI: -0.182 to 0.053) (p < 0.001). CONCLUSION: DLIR enables a 50% dose reduction for detecting low-contrast hepatic metastases while maintaining comparable image quality to full-dose FBP and IR. KEY POINTS: • Non-inferiority study showed that deep learning image reconstruction (DLIR) can reduce the dose to oncological patients with low-contrast lesions without compromising the diagnostic information. • Radiation dose levels for DLIR can be reduced to 50% of full-dose FBP and IR for detecting low-contrast hepatic metastases, while maintaining comparable image quality. • The reduction of radiation by 70% by DLIR is clinically acceptable but insufficient for detecting small low-contrast hepatic metastases (< 1 cm).


Assuntos
Aprendizado Profundo , Neoplasias Hepáticas , Humanos , Algoritmos , Processamento de Imagem Assistida por Computador , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Imagens de Fantasmas , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos
2.
AJR Am J Roentgenol ; 204(5): W579-85, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25905965

RESUMO

OBJECTIVE: The purpose of this study is to measure the organ doses and effective dose (ED) for parathyroid 4D CT and scintigraphy and to estimate the lifetime attributable risk of cancer incidence associated with imaging. MATERIALS AND METHODS: Organ radiation doses for 4D CT and scintigraphy were measured on the basis of imaging with our institution's protocols. An anthropomorphic phantom with metal oxide semiconductor field effect transistor detectors was scanned to measure CT organ dose. Organ doses from the radionuclide were based on International Commission for Radiological Protection report 80. ED was calculated for 4D CT and scintigraphy and was used to estimate the lifetime attributable risk of cancer incidence for patients differing in age and sex with the approach established by the Biologic Effects of Ionizing Radiation VII report. A 55-year-old woman was selected as the standard patient according to the demographics of patients with primary hyperparathyroidism. RESULTS: Organs receiving the highest radiation dose from 4D CT were the thyroid (150.6 mGy) and salivary glands (137.8 mGy). For scintigraphy, the highest organ doses were to the colon (41.5 mGy), gallbladder (39.8 mGy), and kidneys (32.3 mGy). The ED was 28 mSv for 4D CT, compared with 12 mSv for scintigraphy. In the exposed standard patient, the lifetime attributable risk for cancer incidence was 193 cancers/100,000 patients for 4D CT and 68 cancers/100,000 patients for scintigraphy. Given a baseline lifetime incidence of cancer of 46,300 cancers/100,000 patients, imaging results in an increase in lifetime incidence of cancer over baseline of 0.52% for 4D CT and 0.19% for scintigraphy. CONCLUSION: The ED of 4D CT is more than double that of scintigraphy, but both studies cause negligible increases in lifetime risk of cancer. Clinicians should not allow concern for radiation-induced cancer to influence decisions regarding workup in older patients.


Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Induzidas por Radiação/etiologia , Doenças das Paratireoides/diagnóstico por imagem , Doses de Radiação , Feminino , Humanos , Incidência , Masculino , Neoplasias Induzidas por Radiação/epidemiologia , Imagens de Fantasmas , Cintilografia , Medição de Risco , Fatores de Risco
3.
J Comput Assist Tomogr ; 39(2): 196-201, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25474144

RESUMO

PURPOSE: The aim of the study was to assess the image quality of multi-detector-row computed tomography (CT) angiographic images of the thoracic aorta reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction, and model-based iterative reconstruction (MBIR) at different kVp and mA settings. METHODS: A healthy 56.1-kg Yorkshire pig underwent sequential arterial CT angiograms on a 64-slice multi-detector-row CT scanner (Discovery CT 750HD; GE Healthcare Inc, Milwaukee, Wis) at progressively lower kVp and mA settings. At 120-, 100-, and 80-kVp levels, the pig was scanned at 700, 400, 200, 100, and 50 mA at, for a total of 15 scans. Each scan was reconstructed with FBP, adaptive statistical iterative reconstruction (50% blend), and MBIR. Relative noise and contrast-to-noise ratio (CNR) were calculated from regions of interest over the aorta and paraspinous muscle. In addition, selected axial and oblique sagittal images were scored subjectively for both aortic wall visibility and for overall image quality. RESULTS: Averaged across all kVp and mA variations, MBIR reduced relative noise by 73.9% and improved CNR by 227% compared with FBP; MBIR reduced relative noise by 63.4% and improved CNR by 107% compared with ASIR. The effects were more pronounced in lower tube output settings. At 100 kVp/700 mA, MBIR reduced noise by 57% compared with FBP and 40% compared with ASIR. At 100 kVp/50 mA, MBIR reduced noise by 82% compared with FBP and 75% compared with ASIR. Subjective improvements in image quality were noted only in higher noise settings. CONCLUSIONS: Model-based iterative reconstruction reduces relative noise and improves CNR compared with ASIR and FBP at all kVp and mA settings, which were significantly greater at lower mA settings.


Assuntos
Aorta Torácica/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Angiografia/métodos , Animais , Masculino , Modelos Animais , Doses de Radiação , Suínos
4.
J Urol ; 189(6): 2142-6, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23261481

RESUMO

PURPOSE: Patients with recurrent nephrolithiasis are often evaluated and followed with computerized tomography. Obesity is a risk factor for nephrolithiasis. We evaluated the radiation dose of computerized tomography in obese and nonobese adults. MATERIALS AND METHODS: We scanned a validated, anthropomorphic male phantom according to our institutional renal stone evaluation protocol. The obese model consisted of the phantom wrapped in 2 Custom Fat Layers (CIRS, Norfolk, Virginia), which have been verified to have the same radiographic tissue density as fat. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ locations in the phantoms to measure organ specific radiation doses. The nonobese and obese models have an approximate body mass index of 24 and 30 kg/m(2), respectively. Three runs of renal stone protocol computerized tomography were performed on each phantom under automatic tube current modulation. Organ specific absorbed doses were measured and effective doses were calculated. RESULTS: The bone marrow of each model received the highest dose and the skin received the second highest dose. The mean ± SD effective dose for the nonobese and obese models was 3.04 ± 0.34 and 10.22 ± 0.50 mSv, respectively (p <0.0001). CONCLUSIONS: The effective dose of stone protocol computerized tomography in obese patients is more than threefold higher than the dose in nonobese patients using automatic tube current modulation. The implication of this finding extends beyond the urological stone population and adds to our understanding of radiation exposure from medical imaging.


Assuntos
Obesidade/complicações , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/efeitos adversos , Carga Corporal (Radioterapia) , Índice de Massa Corporal , Humanos , Masculino , Modelos Teóricos , Nefrolitíase/diagnóstico por imagem , Monitoramento de Radiação/métodos , Recidiva , Valores de Referência , Tomografia Computadorizada por Raios X/métodos
5.
J Urol ; 190(6): 2117-23, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23764073

RESUMO

PURPOSE: Computerized tomography use increased exponentially in the last 3 decades, and it is commonly used to evaluate many urological conditions. Ionizing radiation exposure from medical imaging is linked to the risk of malignancy. We measured the organ and calculated effective doses of different studies to determine whether the dose-length product method is an accurate estimation of radiation exposure. MATERIALS AND METHODS: An anthropomorphic male phantom validated for human organ dosimetry measurements was used to determine radiation doses. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ locations to measure specific organ doses. For each study the phantom was scanned 3 times using our institutional protocols. Organ doses were measured and effective doses were calculated on dosimetry. Effective doses measured by a metal oxide semiconductor field effect transistor dosimeter were compared to calculated effective doses derived from the dose-length product. RESULTS: The mean±SD effective dose on dosimetry for stone protocol, chest and abdominopelvic computerized tomography, computerized tomography urogram and renal cell carcinoma protocol computerized tomography was 3.04±0.34, 4.34±0.27, 5.19±0.64, 9.73±0.71 and 11.42±0.24 mSv, respectively. The calculated effective dose for these studies Was 3.33, 2.92, 5.84, 9.64 and 10.06 mSv, respectively (p=0.8478). CONCLUSIONS: The effective dose varies considerable for different urological computerized tomography studies. Renal stone protocol computerized tomography shows the lowest dose, and computerized tomography urogram and the renal cell carcinoma protocol accumulate the highest effective doses. The calculated effective dose derived from the dose-length product is a reasonable estimate of patient radiation exposure.


Assuntos
Técnicas de Diagnóstico Urológico/normas , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/normas , Humanos , Masculino
6.
AJR Am J Roentgenol ; 201(5): W730-4, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24063388

RESUMO

OBJECTIVE: The purpose of this study was to measure the organ doses and estimate the effective dose for the standard brain perfusion CT protocol and erroneous protocols. MATERIALS AND METHODS: An anthropomorphic phantom with metal oxide semiconductor field effect transistor (MOSFET) detectors was scanned on a 64-MDCT scanner. Protocol 1 used a standard brain perfusion protocol with 80 kVp and fixed tube current of 200 mA. Protocol 2 used 120 kVp and fixed tube current of 200 mA. Protocol 3 used 120 kVp with automatic tube current modulation (noise index, 2.4; minimum, 100 mA; maximum, 520 mA). RESULTS: Compared with protocol 1, the effective dose was 2.8 times higher with protocol 2 and 7.8 times higher with protocol 3. For all protocols, the peak dose was highest in the skin, followed by the brain and calvarial marrow. Compared with protocol 1, the peak skin dose was 2.6 times higher with protocol 2 and 6.7 times higher with protocol 3. The peak skin dose for protocol 3 exceeded 3 Gy. The ocular lens received significant scatter radiation: 177 mGy for protocol 2 and 435 mGy for protocol 3, which were 4.6 and 11.3 times the dose for protocol 1, respectively. CONCLUSION: Compared with the standard protocol, erroneous protocols of increasing the tube potential from 80 kVp to 120 kVp will lead to a three- to fivefold increase in organ doses, and concurrent use of high peak kilovoltage with incorrectly programmed tube current modulation can increase dose to organs by 7- to 11-fold. Tube current modulation with a low noise index can lead to doses to the skin and ocular lens that are close to thresholds for tissue reactions.


Assuntos
Encéfalo/diagnóstico por imagem , Doses de Radiação , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/instrumentação
7.
EMBO J ; 27(14): 1932-43, 2008 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-18566586

RESUMO

The target of rapamycin (TOR), as part of the rapamycin-sensitive TOR complex 1 (TORC1), regulates various aspects of protein synthesis. Whether TOR functions in this process as part of TORC2 remains to be elucidated. Here, we demonstrate that mTOR, SIN1 and rictor, components of mammalian (m)TORC2, are required for phosphorylation of Akt and conventional protein kinase C (PKC) at the turn motif (TM) site. This TORC2 function is growth factor independent and conserved from yeast to mammals. TM site phosphorylation facilitates carboxyl-terminal folding and stabilizes newly synthesized Akt and PKC by interacting with conserved basic residues in the kinase domain. Without TM site phosphorylation, Akt becomes protected by the molecular chaperone Hsp90 from ubiquitination-mediated proteasome degradation. Finally, we demonstrate that mTORC2 independently controls the Akt TM and HM sites in vivo and can directly phosphorylate both sites in vitro. Our studies uncover a novel function of the TOR pathway in regulating protein folding and stability, processes that are most likely linked to the functions of TOR in protein synthesis.


Assuntos
Proteína Quinase C/metabolismo , Proteínas Quinases/metabolismo , Proteínas Proto-Oncogênicas c-akt/metabolismo , Proteínas Adaptadoras de Transdução de Sinal/metabolismo , Motivos de Aminoácidos , Animais , Proteínas de Transporte/metabolismo , Linhagem Celular , Embrião de Mamíferos/citologia , Fibroblastos/metabolismo , Humanos , Camundongos , Modelos Moleculares , Complexos Multiproteicos/metabolismo , Dobramento de Proteína , Proteína Quinase C/química , Proteínas Proto-Oncogênicas c-akt/química , Serina-Treonina Quinases TOR
8.
AJR Am J Roentgenol ; 198(3): 621-7, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22358002

RESUMO

OBJECTIVE: The purpose of this study was to assess the effect of peak kilovoltage on radiation dose and image quality in adult neck MDCT. MATERIALS AND METHODS: An anthropomorphic phantom with metal oxide semiconductor field effect transistor detectors was imaged with a 64-MDCT scanner. The reference CT protocol called for 120 kVp, and images obtained with that protocol were compared with CT images obtained with protocols entailing 80, 100, and 140 kVp. All imaging was performed with automatic tube current modulation. Organ dose and effective dose were determined for each protocol and compared with those obtained with the 120-kVp protocol. Image noise was evaluated objectively and subjectively for each protocol. RESULTS: The highest organ doses for all protocols were to the thyroid, ocular lens, skin, and mandible. The greatest reductions in organ dose were for the bone marrow of the cervical spine and mandible: 43% and 35% with the 100-kVp protocol and 63% and 53% with the 80-kVp protocol. Effective dose decreased as much as 9% with the 100-kVp protocol and 12% with the 80-kVp protocol. Use of the 140-kVp protocol was associated with an increase in organ dose as high as 64% for bone marrow in the cervical spine and a 19% increase in effective dose. Image noise increased with lower peak kilovoltage. The measured noise difference was greatest at 80 kVp, absolute increases were less than 2.5 HU. There was no difference in subjective image quality among protocols. CONCLUSION: Reducing the voltage from 120 to 80 kVp for neck CT can result in greater than 50% reduction in the absorbed organ dose to the bone marrow of the cervical spine and mandible without impairment in subjective image quality.


Assuntos
Pescoço/diagnóstico por imagem , Tomografia Computadorizada Espiral/métodos , Adulto , Humanos , Imagens de Fantasmas , Doses de Radiação , Proteção Radiológica , Interpretação de Imagem Radiográfica Assistida por Computador , Valores de Referência
9.
AJR Am J Roentgenol ; 198(5): 1132-8, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22528904

RESUMO

OBJECTIVE: The purpose of this study was to assess the difference in absorbed organ dose and image quality for MDCT neck protocols using automatic tube current modulation alone compared with organ-based dose modulation and in-plane thyroid bismuth shielding. MATERIALS AND METHODS: An anthropomorphic female phantom with metal oxide semiconductor field effect transistor (MOSFET) detectors was scanned on a 64-MDCT scanner. The protocols included a reference neck CT protocol using automatic tube current modulation and three modified protocols: organ-based dose modulation, automatic tube current modulation with thyroid shield, and organ-based dose modulation with thyroid shield. Image noise was evaluated quantitatively with the SD of the attenuation value, and subjectively by two neuroradiologists. RESULTS: Organ-based dose modulation, automatic tube current modulation with thyroid shield, and organ-based dose modulation with thyroid shield protocols reduced the thyroid dose by 28%, 33%, and 45%, respectively, compared with the use of automatic tube current modulation alone (p ≤ 0.005). Organ-based dose modulation also reduced the radiation dose to the ocular lens (33-47%) compared with the use of automatic tube current modulation (p ≤ 0.04). There was no significant difference in measured noise and subjective image quality between the protocols. CONCLUSION: Both organ-based dose modulation and thyroid shields significantly reduce the thyroid organ dose without degradation of subjective image quality compared with automatic tube current modulation. Organ-based dose modulation has the additional benefit of dose reduction to the ocular lens.


Assuntos
Doses de Radiação , Proteção Radiológica/instrumentação , Glândula Tireoide/efeitos da radiação , Tomografia Computadorizada por Raios X , Carga Corporal (Radioterapia) , Feminino , Humanos , Pescoço , Imagens de Fantasmas , Radiometria , Software
10.
AJR Am J Roentgenol ; 199(1): W65-73, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22733933

RESUMO

OBJECTIVE: The purpose of this study was to assess the radiation dose distribution and image quality for organ-based dose modulation during adult thoracic MDCT. MATERIALS AND METHODS: Organ doses were measured using an anthropomorphic adult female phantom containing 30 metal oxide semiconductor field-effect transistor detectors on a dual-source MDCT scanner with two protocols: standard tube current modulation thoracic CT and organ-based dose modulation using a 120° radial arc. Radiochromic film measured the relative axial dose. Noise was measured to evaluate image quality. Breast tissue location across the anterior aspect of the thorax was retrospectively assessed in 100 consecutive thoracic MDCT examinations. RESULTS: There was a 17-47% decrease (p = < 0.05) in anterior thoracic organ dose and a maximum 52% increase (p = < 0.05) in posterior thoracic organ dose using organ-based dose modulation compared with tube current modulation. Effective dose (SD) for tube current modulation and organ-based dose modulation were 5.25 ± 0.36 mSv and 4.42 ± 0.30 mSv, respectively. Radiochromic film analysis showed a 30% relative midline anterior-posterior gradient. There was no statistically significant difference in image noise. Adult female breast tissue was located within an average anterior angle of 155° (123-187°). CONCLUSION: Organ-based dose modulation CT using an anterior 120° arc can reduce the organ dose in the anterior aspect of the thorax with a compensatory organ dose increase posteriorly without impairment of image quality. Laterally located breast tissue will have higher organ doses than medially located breast tissue when using organ-based dose modulation. The benefit of this dose reduction must be clinically determined on the basis of the relationship of the irradiated organs to the location of the prescribed radial arc used in organ-based dose modulation.


Assuntos
Exposição Ambiental/análise , Doses de Radiação , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Proteção Radiológica/métodos , Intensificação de Imagem Radiográfica , Dosagem Radioterapêutica , Estudos Retrospectivos , Tórax , Adulto Jovem
11.
Eur J Radiol ; 141: 109825, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34144309

RESUMO

OBJECTIVE: To assess the diagnostic performance and reader confidence in determining the resectability of pancreatic cancer at computed tomography (CT) using a new deep learning image reconstruction (DLIR) algorithm. METHODS: A retrospective review was conduct of on forty-seven patients with pathologically confirmed pancreatic cancers who underwent baseline multiphasic contrast-enhanced CT scan. Image data sets were reconstructed using filtered back projection (FBP), hybrid model-based adaptive statistical iterative reconstruction (ASiR-V) 60 %, and DLIR "TrueFidelity" at low(L), medium(M), and high strength levels(H). Four board-certified abdominal radiologists reviewed the CT images and classified cancers as resectable, borderline resectable, or unresectable. Diagnostic performance and reader confidence for categorizing the resectability of pancreatic cancer were evaluated based on the reference standards, and the interreader agreement was assessed using Fleiss k statistics. RESULTS: For prediction of margin-negative resections(ie, R0), the average area under the receiver operating characteristic curve was significantly higher with DLIR-H (0.91; 95 % confidence interval [CI]: 0.79, 0.98) than FBP (0.75; 95 % CI:0.60, 0.86) and ASiR-V (0.81; 95 % CI:0.67, 0.91) (p = 0.030 and 0.023 respectively). Reader confidence scores were significantly better using DLIR compared to FBP and ASiR-V 60 % and increased linearly with the increase of DLIR strength level (all p < 0.001). Among the image reconstructions, DLIR-H showed the highest interreader agreement in the resectability classification and lowest subject variability in the reader confidence. CONCLUSIONS: The DLIR-H algorithm may improve the diagnostic performance and reader confidence in the CT assignment of the local resectability of pancreatic cancer while reducing the interreader variability.


Assuntos
Aprendizado Profundo , Neoplasias Pancreáticas , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/cirurgia , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
12.
Weed Res ; 61(6): 475-485, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35874455

RESUMO

Zero tillage (ZT) is widely promoted throughout India's Eastern Indo-Gangetic Plains (IGP) because of its potential to increase wheat productivity and resilience to abiotic stresses. Weeds remain a major barrier to ZT adoption, yet it remains unclear how ZT will influence weed communities in the Eastern-IGP. The primary objective of this study was to characterise the composition of the germinable weed seedbank sampled just prior to the wheat phase of rice-wheat farms in Bihar and Eastern Uttar Pradesh, and examine whether adoption of ZT wheat has shifted weed community composition compared to conventional tillage (CT). Additionally, we examined whether edaphic properties and topography (upland vs. lowland) explain variation in germinable weed seedbank communities. In December 2014, we evaluated the germinable seedbank from 72 fields differing in their historic (>=3 year) tillage practices (ZT vs. CT) in three regions: Samastipur-Vaishali-Muzaffarpur (SVM), Ara-Buxar and Maharajgunj-Kushinagar. Weed community composition and species richness varied by region and topography. ZT adoption was associated with lower relative density of Chenopodium album in the germinable seedbank and lower emergence of Phalaris minor seedlings within farmers' fields. In upland topographies of the SVM region, ZT adoption was also associated with greater relative abundance of Solanum nigrum in the weed seedbank. However, differences between tillage systems in individual species were not large enough to result in detection of differences at the whole-community level. Variation in edaphic properties, most notably soil texture and pH, explained 51% of the variation in the weed seedbank community. Our work suggests several frequent but poorly understood species (e.g. Mazus pumilus and Grangea maderaspatana) in Eastern IGP for which future research should quantify their effects on crop yields. Finally, future work surveying weed species abundance at harvest could further determine the dominant problematic species in these regions.

13.
Med Phys ; 48(8): 4375-4386, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34105167

RESUMO

PURPOSE: Chemical shift-encoded magnetic resonance imaging enables accurate quantification of liver fat content though estimation of proton density fat-fraction (PDFF). Computed tomography (CT) is capable of quantifying fat, based on decreased attenuation with increased fat concentration. Current quantitative fat phantoms do not accurately mimic the CT number of human liver. The purpose of this work was to develop and validate an optimized phantom that simultaneously mimics the MRI and CT signals of fatty liver. METHODS: An agar-based phantom containing 12 vials doped with iodinated contrast, and with a granular range of fat fractions was designed and constructed within a novel CT and MR compatible spherical housing design. A four-site, three-vendor validation study was performed. MRI (1.5T and 3T) and CT images were obtained using each vendor's PDFF and CT reconstruction, respectively. An ROI centered in each vial was placed to measure MRI-PDFF (%) and CT number (HU). Mixed-effects model, linear regression, and Bland-Altman analysis were used for statistical analysis. RESULTS: MRI-PDFF agreed closely with nominal PDFF values across both field strengths and all MRI vendors. A linear relationship (slope = -0.54 ± 0.01%/HU, intercept = 37.15 ± 0.03%) with an R2 of 0.999 was observed between MRI-PDFF and CT number, replicating established in vivo signal behavior. Excellent test-retest repeatability across vendors (MRI: mean = -0.04%, 95% limits of agreement = [-0.24%, 0.16%]; CT: mean = 0.16 HU, 95% limits of agreement = [-0.15HU, 0.47HU]) and good reproducibility using GE scanners (MRI: mean = -0.21%, 95% limits of agreement = [-1.47%, 1.06%]; CT: mean = -0.18HU, 95% limits of agreement = [-1.96HU, 1.6HU]) were demonstrated. CONCLUSIONS: The proposed fat phantom successfully mimicked quantitative liver signal for both MRI and CT. The proposed fat phantom in this study may facilitate broader application and harmonization of liver fat quantification techniques using MRI and CT across institutions, vendors and imaging platforms.


Assuntos
Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Fígado , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Reprodutibilidade dos Testes
14.
AJR Am J Roentgenol ; 195(2): 433-8, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20651201

RESUMO

OBJECTIVE: The purpose of this study was to determine, using an anthropomorphic phantom, whether patients are subject to variable radiation doses based on scanner assignment for routine CT of the brain. MATERIALS AND METHODS: Twenty metal oxide semiconductor field effect transistor dosimeters were placed in the brain of a male anthropomorphic phantom scanned three times with a routine clinical brain CT protocol on four scanners from one manufacturer in four configurations and on one 64-MDCT scanner from another manufacturer. Absorbed organ doses were measured for skin, cranium, brain, lens of the eye, mandible, and thyroid. Effective dose was calculated on the basis of the dose-length product recorded on each scanner. RESULTS: Organ dose ranges were as follows: cranium, 2.57-3.47 cGy; brain, 2.34-3.78 cGy; lens, 2.51-5.03 cGy; mandible 0.17-0.48 cGy; and thyroid, 0.03-0.28 cGy. Statistically significant differences between scanners with respect to dose were recorded for brain and lens (p < 0.05). Absorbed doses were lowest on the single-detector scanner. In the comparison of MDCT scanners, the highest doses were found on the 4-MDCT scanner and the dual-source 64-MDCT scanner not capable of gantry tilt. Effective dose ranged from 1.22 to 1.86 mSv. CONCLUSION: According to the phantom data, patients are subject to different organ doses in the lens and brain depending on scanner assignment. At our institution with existing protocols, absorbed doses at brain CT are lowest with the single-detector CT scanner, followed by MDCT scanners capable of gantry tilt. On scanners without gantry tilt, CT of the brain should be performed with careful head positioning and shielding of the orbits. These precautions are especially true for patients who need repeated scanning and for pediatric patients.


Assuntos
Carga Corporal (Radioterapia) , Encéfalo/diagnóstico por imagem , Doses de Radiação , Radiometria/estatística & dados numéricos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adulto , Criança , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Masculino , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
AoB Plants ; 12(4): plaa026, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32665828

RESUMO

Plant-microbe interactions in the rhizosphere influence rates of organic matter mineralization and nutrient cycling that are critical to sustainable agricultural productivity. Agricultural intensification, particularly the introduction of synthetic fertilizer in the USA, altered the abundance and dominant forms of nitrogen (N), a critical plant nutrient, potentially imposing selection pressure on plant traits and plant-microbe interactions regulating N cycling and acquisition. We hypothesized that maize adaptation to synthetic N fertilization altered root functional traits and rhizosphere microbial nutrient cycling, reducing maize ability to acquire N from organic sources. Six maize genotypes released pre-fertilizer (1936, 1939, 1942) or post-fertilizer (1984, 1994, 2015) were grown in rhizoboxes containing patches of 15N-labelled clover/vetch residue. Multivariate approaches did not identify architectural traits that strongly and consistently predicted rhizosphere processes, though metrics of root morphological plasticity were linked to carbon- and N-cycling enzyme activities. Root traits, potential activities of extracellular enzymes (BG, LAP, NAG, urease), abundances of N-cycling genes (amoA, narG, nirK, nirS, nosZ) and uptake of organic N did not differ between eras of release despite substantial variation among genotypes and replicates. Thus, agricultural intensification does not appear to have impaired N cycling and acquisition from organic sources by modern maize and its rhizobiome. Improved mechanistic understanding of rhizosphere processes and their response to selective pressures will contribute greatly to rhizosphere engineering for sustainable agriculture.

16.
AJR Am J Roentgenol ; 193(4): 1019-24, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19770324

RESUMO

OBJECTIVE: The purpose of this study was to corroborate the relation between the estimated absorbed fetal dose derived from directly measured uterine doses early in the first trimester and the volume CT dose index (CTDI(vol)) for 16- and 64-MDCT of the maternal chest, abdomen, and pelvis. MATERIALS AND METHODS: Estimated absorbed fetal dose was measured with a metal oxide semiconductor field effect transistor (MOSFET) dosimeter placed in the expected uterine location in an anthropomorphic phantom of a woman and scanned with 16- and 64-MDCT units of one vendor and a 64-MDCT unit of another vendor. A trauma chest, abdomen, and pelvis protocol and an abdomen and pelvis protocol were used. Absorbed uterine dose was measured directly from the MOSFET detector. The CTDI(vol) for each protocol was recorded from the scanner console. Correlation between mean uterine dose and CTDI(vol) was tested with a goodness of fit model. RESULTS: The absorbed uterine dose ranged from 9.25 to 37.7 mGy. Absorbed fetal dose in the early first trimester correlated with CTDI(vol) in a linear regression equation. For the 16-MDCT scanner, at 130 kVp, the fetal dose was 2.091 x CTDI(vol) - 9.489. For the 64-MDCT scanner from the same vendor, at 120 kVp, the fetal dose was 1.113 x CTDI(vol) + 1.773. For the 64-MDCT scanner from the other vendor, at 120 kVp, the fetal dose was 1.378 x CTDI(vol) - 1.014. The goodness of fit results (R(2)) for the equations were 0.97, 0.98, and 0.99. CONCLUSION: Estimated absorbed fetal dose during the first trimester of pregnancy is linearly associated with CTDI(vol) regardless of beam energy, detector configuration, and scanner manufacturer.


Assuntos
Carga Corporal (Radioterapia) , Feto/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Contagem Corporal Total/métodos , Adulto , Feminino , Humanos , Imagens de Fantasmas , Gravidez , Primeiro Trimestre da Gravidez , Doses de Radiação
17.
AJR Am J Roentgenol ; 192(1): 244-53, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19098206

RESUMO

OBJECTIVE: The purpose of this study was to assess whether radiation dose savings using a lower peak kilovoltage (kVp) setting, bismuth breast shields, and automatic tube current modulation could be achieved while preserving the image quality of MDCT scans obtained to assess for pulmonary embolus (PE). MATERIALS AND METHODS: CT angiography (CTA) examinations were performed to assess for the presence or absence of pulmonary artery emboli using a 64-MDCT scanner with automatic tube current modulation (noise level=10 HU), two kVp settings (120 and 140 kVp), and bismuth breast shields. Absorbed organ doses were measured using anthropomorphic phantoms and metal oxide semiconductor field effect transistor (MOSFET) detectors. Image quality was assessed quantitatively as well as qualitatively in various anatomic sites of the thorax. RESULTS: Using a lower kVp (120 vs 140 kVp) and automatic tube current modulation resulted in a dose savings of 27% to the breast and 47% to the lungs. The use of a lower kVp (120 kVp), automatic tube current modulation, and bismuth shields placed directly on the anterior chest wall reduced absorbed breast and lung doses by 55% and 45%, respectively. Qualitative assessment of the images showed no change in image quality of the lungs and mediastinum when using a lower kVp, bismuth shields, or both. CONCLUSION: The use of bismuth breast shields together with a lower kVp and automatic tube current modulation will reduce the absorbed radiation dose to the breast and lungs without degradation of image quality to the organs of the thorax for CTA detection of PE.


Assuntos
Carga Corporal (Radioterapia) , Embolia Pulmonar/diagnóstico por imagem , Proteção Radiológica/instrumentação , Proteção Radiológica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Adulto , Feminino , Humanos , Masculino , Doses de Radiação , Eficiência Biológica Relativa
18.
AJR Am J Roentgenol ; 193(4): 1141-7, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19770340

RESUMO

OBJECTIVE: The objective of our study was to determine, using an anthropomorphic phantom, whether patients are subject to variable radiation doses based on scanner assignment for common body CT studies. MATERIALS AND METHODS: Twenty metal oxide semiconductor field effect transistor dosimeters were placed in a medium-sized anthropomorphic phantom of a man. Pulmonary embolism and chest, abdomen, and pelvis protocols were used to scan the phantom three times with GE Healthcare scanners in four configurations and one 64-MDCT Siemens Healthcare scanner. Organ doses were averaged, and effective doses were calculated with weighting factors. RESULTS: The mean effective doses for the pulmonary embolism protocol ranged from 9.9 to 18.5 mSv and for the chest, abdomen, and pelvis protocol from 6.7 to 18.5 mSv. For the pulmonary embolism protocol, the mean effective dose from the Siemens Healthcare 64-MDCT scanner was significantly lower than that from the 16- and 64-MDCT GE Healthcare scanners (p < 0.001). The mean effective dose from the GE 4-MDCT scanner was significantly lower than that for the GE 16-MDCT scanner (p < 0.001) but not the GE 64-MDCT scanner (p = 0.02). For the chest, abdomen, and pelvis protocol, all mean effective doses from the GE scanners were significantly different from one another (p < 0.001), the lowest mean effective dose being found with use of a single-detector CT scanner and the highest with a 4-MDCT scanner. For the chest, abdomen, and pelvis protocols, the difference between the mean effective doses from the GE Healthcare and Siemens Healthcare 64-MDCT scanners was not statistically significant (p = 0.89). CONCLUSION: According to phantom data, patients are subject to different radiation exposures for similar body CT protocols depending on scanner assignment. In general, doses are lowest with use of 64-MDCT scanners.


Assuntos
Carga Corporal (Radioterapia) , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Contagem Corporal Total/métodos , Adulto , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Masculino , Imagens de Fantasmas , Eficiência Biológica Relativa
19.
J Am Coll Radiol ; 16(3): 295-301, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30082238

RESUMO

Patient-centric care has garnered the attention of the radiology community. The authors describe a patient-centric approach to iodinated contrast administration designed to optimize the diagnostic yield of contrast-enhanced CT while minimizing patient iodine load and exposure to ionizing radiation, thereby enhancing patient safety while providing reasonable diagnostic efficacy. Patient-centric CT hardware settings and contrast media administration are important considerations for clinical CT quality and safety.


Assuntos
Meios de Contraste/administração & dosagem , Segurança do Paciente , Assistência Centrada no Paciente , Tomografia Computadorizada por Raios X , Humanos , Exposição à Radiação , Proteção Radiológica/métodos
20.
J Vis Exp ; (140)2018 10 22.
Artigo em Inglês | MEDLINE | ID: mdl-30394399

RESUMO

Roots are notoriously difficult to study. Soil is both a visual and mechanical barrier, making it difficult to track roots in situ without destructive harvest or expensive equipment. We present a customizable and affordable rhizobox method that allows the non-destructive visualization of root growth over time and is particularly well-suited to studying root plasticity in response to localized resource patches. The method was validated by assessing maize genotypic variation in plasticity responses to patches containing 15N-labeled legume residue. Methods are described to obtain representative developmental measurements over time, measure root length density in resource-containing and control patches, calculate root growth rates, and determine 15N recovery by plant roots and shoots. Advantages, caveats, and potential future applications of the method are also discussed. Although care must be taken to ensure that experimental conditions do not bias root growth data, the rhizobox protocol presented here yields reliable results if carried out with sufficient attention to detail.


Assuntos
Nutrientes/metabolismo , Raízes de Plantas/crescimento & desenvolvimento , Solo/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA