Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Proc Natl Acad Sci U S A ; 118(45)2021 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-34670842

RESUMO

Vaccination against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and other pathogens with pandemic potential requires safe, protective, inexpensive, and easily accessible vaccines that can be developed and manufactured rapidly at a large scale. DNA vaccines can achieve these criteria, but induction of strong immune responses has often required bulky, expensive electroporation devices. Here, we report an ultra-low-cost (<1 USD), handheld (<50 g) electroporation system utilizing a microneedle electrode array ("ePatch") for DNA vaccination against SARS-CoV-2. The low cost and small size are achieved by combining a thumb-operated piezoelectric pulser derived from a common household stove lighter that emits microsecond, bipolar, oscillatory electric pulses and a microneedle electrode array that targets delivery of high electric field strength pulses to the skin's epidermis. Antibody responses against SARS-CoV-2 induced by this electroporation system in mice were strong and enabled at least 10-fold dose sparing compared to conventional intramuscular or intradermal injection of the DNA vaccine. Vaccination was well tolerated with mild, transient effects on the skin. This ePatch system is easily portable, without any battery or other power source supply, offering an attractive, inexpensive approach for rapid and accessible DNA vaccination to combat COVID-19, as well as other epidemics.


Assuntos
Vacinas contra COVID-19/administração & dosagem , COVID-19/imunologia , COVID-19/prevenção & controle , Eletroporação/instrumentação , SARS-CoV-2 , Vacinas de DNA/administração & dosagem , Animais , Vacinas contra COVID-19/genética , Vacinas contra COVID-19/imunologia , Custos e Análise de Custo , Eletroporação/economia , Eletroporação/métodos , Desenho de Equipamento , Feminino , Genes Reporter , Humanos , Camundongos , Camundongos Endogâmicos BALB C , Microeletrodos , Agulhas , Pandemias/prevenção & controle , Estudo de Prova de Conceito , Ratos , Ratos Wistar , Pele/imunologia , Pele/metabolismo , Transfecção , Vacinação/economia , Vacinação/instrumentação , Vacinação/métodos , Vacinas de DNA/genética , Vacinas de DNA/imunologia
2.
Biomacromolecules ; 21(2): 854-866, 2020 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-31877029

RESUMO

Antibiotics are commonly added to poly(methyl methacrylate) (PMMA) by surgeons to locally treat infections such as in bone cement for joint replacement surgeries, as well as implantable antimicrobial "beads". However, this strategy is of limited value in high-risk patients where infections can be recurrent or chronic and otherwise hard to treat. Also, when only one drug is incorporated and applied toward polymicrobial infections (multiple bacterial species), there is a high risk that bacteria can develop antibiotic resistance. To combat these limitations, we developed a combination antibiotic PMMA composite system composed of rifampicin-filled ß-cyclodextrin (ß-CD) microparticles added into PMMA filled with a second drug. Different formulations were evaluated through zone of inhibition, drug activity, antibiotic release, and refilling, as well as mechanical studies. Our combination antibiotic PMMA composite system achieved up to an 8-fold increase in the duration of antimicrobial activity in comparison to clinically used antibiotic-filled PMMA. Inclusion of CD microparticles also allowed for refilling of additional antibiotics after simulated implantation, resulting in additional windows of therapeutic efficacy. Mechanical testing showed that our tested formulations did have a small, but significant decrease in mechanical properties when compared to unmodified controls. While further studies are needed to determine whether the tested formulations are still suitable for load-bearing applications (e.g., bone cement), our composites are certainly amenable for a variety of nonload-bearing applications (e.g., antimicrobial "beads" and temporary spacer in two-stage arthroscopic revisions).


Assuntos
Antibacterianos/química , Cimentos Ósseos/química , Sistemas de Liberação de Medicamentos/métodos , Microesferas , Polimetil Metacrilato/química , Antibacterianos/administração & dosagem , Antibacterianos/metabolismo , Cimentos Ósseos/metabolismo , Preparações de Ação Retardada/administração & dosagem , Preparações de Ação Retardada/química , Preparações de Ação Retardada/metabolismo , Combinação de Medicamentos , Humanos , Teste de Materiais/métodos , Polimetil Metacrilato/administração & dosagem , Polimetil Metacrilato/metabolismo , Staphylococcus epidermidis/efeitos dos fármacos , Staphylococcus epidermidis/fisiologia , Microtomografia por Raio-X/métodos
3.
Bioeng Transl Med ; 9(4): e10662, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39036075

RESUMO

Electroporation, or the use of electric pulses to facilitate the intracellular delivery of DNA, RNA, and other molecules, is a well-established technique, that has been demonstrated to significantly augment the immunogenicity of DNA/mRNA vaccines and therapeutics. However, the clinical translation of traditional electroporators has been limited due to high costs, large size, complex user operation, and poor tolerability in humans due to nerve stimulation. In prior work, we introduced ePatch: an ultra-low-cost, handheld, battery-free electroporator employing a piezoelectric pulser coupled with a microneedle electrode array that showed enhanced immunogenic responses to an intradermal SARS-CoV-2 DNA vaccine in mice. The current study shifts focus from efficacy to tolerability, hypothesizing that ePatch's microneedle array, which localizes the electric field to the superficial skin strata, will minimize nerve stimulation and improve patient comfort. We tested this hypothesis in 14 healthy adults, monitoring pain and other potential adverse effects associated with electroporation. Compared to the insertion of a traditional hypodermic needle, the ePatch was less painful. Adverse effects such as pain, tenderness, erythema and swelling at the application sites were minimal, transient, and statistically indistinguishable between the experimental and placebo ePatch application, suggesting excellent tolerability towards electroporation. In summary, ePatch has a favorable tolerability profile in humans and offers the potential for the safe use of electroporation in a variety of clinical settings, including DNA and mRNA vaccination.

4.
Macromol Biosci ; 21(7): e2000328, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33885231

RESUMO

Antibiotic-loaded poly(methyl methacrylate) (PMMA) cement is commonly used as a local delivery system to treat and prevent orthopedic infections associated with arthroplasties in load-bearing applications. However, these delivery systems are inefficient as release rate sharply declines to subinhibitory levels. Prior studies have shown that by adding in drug-filled cyclodextrin (CD) microparticles into PMMA cement, a more consistent release is observed, and antibiotic refilling through simulated implantation can be achieved. However, the mechanical strengths of PMMA is reduced. In order to decrease the mechanical loss, modified CD microparticles (PMMA-CD) are synthesized that contain covalently appended PMMA chains. The compressive strengths, handling characteristics, and refilling ability of PMMA cement with PMMA-CD are evaluated. Specifically, up to a 13.7% increase in compressive strength is observed when unmodified CD is substituted with PMMA-CD in PMMA samples with 10 wt% CD microparticles. Additionally, a 13.3% increase in working time, a 7.5% decrease in maximum polymerization temperature, and up to a 32.1% increase in amount of drug refilled are observed with the addition of 10 wt% CD PMMA-CD into PMMA in comparison to plain PMMA without CD microparticles.


Assuntos
Ciclodextrinas , Polimetil Metacrilato , Cimentos Ósseos , Força Compressiva , Teste de Materiais
5.
ACS Biomater Sci Eng ; 6(7): 4024-4035, 2020 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-33463344

RESUMO

Antibiotic-laden poly(methyl methacrylate) (PMMA) bone cement is used in a variety of applications including temporary spacers for load-bearing arthroplasties and non-load bearing orthopedic revision procedures and antibiotic beads to treat infections. Depending upon the surgical preparation technique, properties of PMMA can widely vary. The primary objective of this work was to perform an in-depth structure-function analysis regarding how processing of PMMA impacted material and structural properties (i.e., porosity) and downstream functional properties (i.e., drug refilling and strength). PMMA with cyclodextrin (CD) microparticles was generated via hand- or vacuum-mixing and characterized for material and structural properties including porosity and internal morphology and functional properties of drug refilling, compressive strength, and antimicrobial activity. CD microparticles were incorporated into PMMA to enable functional refilling properties and to determine new information on drug distribution and distance or depth of PMMA which the refilled drug was able to penetrate. Vacuum-mixing of PMMA resulted in improved mechanical strength and allowed for incorporation of greater amounts of CD microparticles but less homogeneity relative to hand-mixing. Refilling studies showed shallow penetration of the drug into PMMA samples without CD. However, PMMA with CD microparticles showed increased depth of drug penetration, indicating that the drug could be delivered deeper within the device, resulting in more drug being available for delivery and more opportunity for later antibiotic refilling on a patient-specific basis. Knowledge of structure-function relationships can assist and provide valuable information in design and optimization of PMMA-CD for specific load-bearing or non-load-bearing applications.


Assuntos
Cimentos Ósseos , Polimetil Metacrilato , Antibacterianos , Força Compressiva , Humanos , Porosidade
6.
Adv Healthc Mater ; 7(21): e1800812, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30152602

RESUMO

Poly(methyl methacrylate) (PMMA) bone cement is used in several biomedical applications including as antibiotic-filled beads, temporary skeletal spacers, and cement for orthopedic implant fixation. To mitigate infection following surgery, antibiotics are often mixed into bone cement to achieve local delivery. However, since implanted cement is often structural, incorporated antibiotics must not compromise mechanical properties; this limits the selection of compatible antibiotics. Furthermore, antibiotics cannot be added to resolve future infections once cement is implanted. Finally, delivery from cement is suboptimal as incorporated antibiotics exhibit early burst release with most of the drug remaining permanently trapped. This prolonged subtherapeutic dosage drives pathogen antibiotic resistance. To overcome these limitations of antibiotic-laden bone cement, insoluble cyclodextrin (CD) microparticles are incorporated into PMMA to provide more sustained delivery of a broader range of drugs, without impacting mechanics. PMMA formulations with and without CD microparticles are synthesized and filled with one of three antibiotics and evaluated using zone of inhibition, drug release, and compression studies. Additionally, the ability of PMMA with microparticles to serve as a refillable antibiotic delivery depot is explored. Findings suggest that addition of CD microparticles to cement promotes postimplantation antibiotic refilling and enables incorporation of previously incompatible antibiotics while preserving favorable mechanical properties.


Assuntos
Antibacterianos/química , Anti-Infecciosos/química , Cimentos Ósseos/química , Teste de Materiais/métodos , Polimetil Metacrilato/química , Gentamicinas/química , Vancomicina/química
7.
J Biomech ; 50: 222-227, 2017 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-27871676

RESUMO

The dispersion of inhaled microparticles in the pulmonary acinus of the lungs is often attributed to the complex interplay between convective mixing, due to irreversible flows, and intrinsic particle motion (i.e. gravity and diffusion). However, the role of each mechanism, the exact nature of such interplay between them and their relative importance still remain unclear. To gain insight into these dispersive mechanisms, we track liquid-suspended microparticles and extract their effective diffusivities inside an anatomically-inspired microfluidic acinar model. Such results are then compared to experiments and numerical simulations in a straight channel. While alveoli of the proximal acinar generations exhibit convective mixing characteristics that lead to irreversible particle trajectories, this local effect is overshadowed by a more dominant dispersion mechanism across the ductal branching network that arises from small but significant streamline crossing due to intrinsic diffusional motion in the presence of high velocity gradients. We anticipate that for true airborne particles, which exhibit much higher intrinsic motion, streamline crossing would be even more significant.


Assuntos
Pulmão/fisiologia , Modelos Biológicos , Aerossóis , Difusão , Gravitação , Microfluídica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA