Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Small ; 18(13): e2104112, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34816589

RESUMO

Foreign body reactions (FBR) to implants seriously impair tissue-implant integration and postoperative adhesion. The macrophage, owing to its phenotypic plasticity, is a major regulator in the formation of the inflammatory microenvironment; NF-κB signaling also plays a vital role in the process. It is hypothesized that NF-κB phosphorylation exerts a proinflammatory regulator in FBR to polylactide membranes (PLA-M) and adhesion. First, in vitro and in vivo experiments show that PLA-M induces NF-κB phosphorylation in macrophages, leading to M1 polarization and release of inflammatory factors. The inflammatory microenvironment formed due to PLA-M accelerates myofibroblast differentiation and release of collagen III and MMP2, jointly resulting in peritendinous adhesion. Therefore, JSH-23 (a selective NF-κB inhibitor)-loaded PLA membrane (JSH-23/PLA-M) is fabricated by blend electrospinning to regulate the associated M1 polarization for peritendinous anti-adhesion. JSH-23/PLA-M specifically inhibits NF-κB phosphorylation in macrophages and exhibits anti-inflammatory and anti-adhesion properties. The findings demonstrate that NF-κB phosphorylation has a critical role in PLA-induced M1 polarization and aggravating FBR to PLA-M. Additionally, JSH-23/PLA-M precisely targets modulation of NF-κB phosphorylation in FBR to break the vicious cycle in peritendinous adhesion therapy.


Assuntos
Ativação de Macrófagos , NF-kappa B , Macrófagos , Poliésteres
2.
Arch Orthop Trauma Surg ; 141(11): 1953-1961, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34342667

RESUMO

INTRODUCTION: Inferior pole fracture of the patella (IPFP) is difficult to repair and stabilize clinically. Although various fixation techniques have been developed, fixation strength and mobility remain daunting challenges to orthopedic surgeons. The goal of this research is to evaluate the biomechanical strength and clinical outcomes of a novel "fishing net" suture fixation procedure. MATERIALS AND METHODS: Four finite element models, modified tension-band wiring fixation, anchor suture fixation, basket plate fixation and "fishing net" suture fixation were built to compare the fixing efficacy of "fishing net" suture fixation with three other fixation methods during IPFP fixation. From January 2018 to February 2019, 17 patients who suffered IPFP and treated by "fishing net" suture (FNS) fixation were compared with 20 patients treated by tension-band wiring (TBW) fixation in database and the two groups were evaluated postoperatively using the modified Cincinnati knee rating system. RESULTS: Biomechanical evaluation showed that the relative displacement values of proximal patella measured by three pairs of points on both sides of the fracture line were the lowest using the "fishing net" suture fixation, while fixation using tension-band wiring and basket plate showed similar levels of stability that were less desirable than the "fishing net" method. As to clinical outcomes, there were 17 (100%) patients exhibited excellent or good results with no internal fixation failures in the FNS group compared to three internal fixation failures in the TBW group. CONCLUSION: The biomechanical and clinical results suggest that the "fishing net" suture fixation is a viable candidate for fixation of IPFP.


Assuntos
Fraturas Ósseas , Patela , Fios Ortopédicos , Fixação Interna de Fraturas , Fraturas Ósseas/cirurgia , Humanos , Patela/cirurgia , Suturas
3.
Acta Biomater ; 155: 333-346, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36243373

RESUMO

Peritendinous adhesion is a major cause of limb dysfunction and disability in clinical practice. Numerous studies suggest that activation of nuclear factor-κB (NF-κB) pathway in macrophages could be the pivotal figure in excessive collagen synthesis and thus peritendinous adhesion formation. In this study, we assumed this pathological process could be suppressed by inhibiting NF-κB phosphorylation and nuclear translocation using pyrrolidine dithiocarbamate (PDTC), a specific NF-κB inhibitor with the ability to penetrate cell membranes, in macrophages. Then, we conducted electrospinning process to incorporate PDTC into poly(L-lactic) acid (PLA) electrospinning membranes, that is, the PDTC-PLA membranes. Further, with integral film quality and stable drug release property, the PDTC-PLA membranes were subsequently analyzed in the capability and mechanism of preventing adhesion formation both in vitro and in vivo. Our results showed inhibition of macrophage proliferation as well as NF-κB pathway activation from in vitro assays and outstanding promotion in inhibiting NF-κB p65 phosphorylation and reducing adhesion formation from in vivo assays of PDTC-PLA compared to PLA membranes. In conclusion, our findings suggested that PDTC-PLA as an alternative therapeutic approach alleviated inflammation and peritendinous adhesion formation through NF-κB signaling pathway. STATEMENT OF SIGNIFICANCE: Pyrrolidine dithiocarbamate (PDTC) can be blended into poly-L-lactic acid (PLA) fibrous membranes by electrospinning process. This incorporation of PDTC into PLA is an effective way to inhibit proinflammatory activation of macrophages and to achieve advanced anti-adhesion outcome after tendon repair.


Assuntos
NF-kappa B , Tiocarbamatos , NF-kappa B/metabolismo , Tiocarbamatos/farmacologia , Tiocarbamatos/uso terapêutico , Antioxidantes/farmacologia , Poliésteres/farmacologia
4.
Adv Mater ; 34(5): e2106564, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34816470

RESUMO

Antiadhesion barriers such as films and hydrogels used to wrap repaired tendons are important for preventing the formation of adhesion tissue after tendon surgery. However, sliding of the tendon can compress the adjacent hydrogel barrier and cause it to rupture, which may then lead to unexpected inflammation. Here, a self-healing and deformable hyaluronic acid (HA) hydrogel is constructed as a peritendinous antiadhesion barrier. Matrix metalloproteinase-2 (MMP-2)-degradable gelatin-methacryloyl (GelMA) microspheres (MSs) encapsulated with Smad3-siRNA nanoparticles are entrapped within the HA hydrogel to inhibit fibroblast proliferation and prevent peritendinous adhesion. GelMA MSs are responsively degraded by upregulation of MMP-2, achieving on-demand release of siRNA nanoparticles. Silencing effect of Smad3-siRNA nanoparticles is around 75% toward targeted gene. Furthermore, the self-healing hydrogel shows relatively attenuated inflammation compared to non-healing hydrogel. The mean adhesion scores of composite barrier group are 1.67 ± 0.51 and 2.17 ± 0.75 by macroscopic and histological evaluation, respectively. The proposed self-healing hydrogel antiadhesion barrier with MMP-2-responsive drug release behavior is highly effective for decreasing inflammation and inhibiting tendon adhesion. Therefore, this research provides a new strategy for the development of safe and effective antiadhesion barriers.


Assuntos
Hidrogéis , Metaloproteinase 2 da Matriz , Humanos , Hidrogéis/farmacologia , Macrófagos/patologia , Metaloproteinase 2 da Matriz/genética , Tendões/cirurgia , Aderências Teciduais/tratamento farmacológico , Aderências Teciduais/patologia , Aderências Teciduais/prevenção & controle
5.
Mater Today Bio ; 16: 100428, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36238965

RESUMO

Tendon injury is one of the most serious orthopedic diseases often leading to disability of patients. Major shortages of tendon healing are due to its multiple comorbidities, uncertainty of therapeutic efficacy and insufficient of angiogenesis. With a deeper understanding of angiogenic mechanism of tendon healing, we investigated an innovative microneedle patch loaded with platelet derived growth factor (PDGF) to achieve a constant systemic administration of PDGF to enhance topical tendon healing. Rat achilles tendon injury model was performed as in vivo animal models. Histological staining showed an enhancement of tendon healing quality, especially angiogenesis. Biomechanical studies demonstrated an increase of tendon stiffness, maximum load and maximum stress with treatment of PDGF-loaded microneedles. Furthermore, MAPK/p38/Cyclin D1 pathway and angiogenesis were found to play an important role in tendon healing process by using a biological high throughput RNA-sequence method and bioinformatic analysis. The high throughput RNA-seq tendon healing results were confirmed by histochemical staining and western blot. These results suggest the novel therapeutic potential of PDGF-loaded microneedle patch in tendon surgery.

6.
Mater Sci Eng C Mater Biol Appl ; 116: 111166, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32806293

RESUMO

Posttraumatic peritendinous adhesion leads to limb disability. Physical barrier was widely used and thus focus was paid to fabricate the hydrophobic surfaces of electrospun membrane for anti-adhesion. However, current methods are limited and complicated. In this study, beeswax (Wax)/poly-L-lactic acid (PLA) anti-adhesion membranes were fabricated by blending electrospinning of Wax and PLA. The water contact angle was tested to investigate the hydrophobicity of the surfaces. Incorporation of Wax into PLA did not destroy the micro-pores between Wax/PLA fibers. After 7-day culture, proliferation of fibroblasts on Wax/PLA anti-adhesion membranes were significantly less than that on culture dish and PLA membranes. In rat Achilles adhesion model, least histological peritendinous adhesion formation was detected on the repaired sites in the group treated with Wax/PLA membranes than PLA membranes. Consequently, blending electrospinning of Wax into PLA is an easy method to fabricate hydrophobic surface of electrospun membrane with advanced peritendinous anti-adhesion outcome.


Assuntos
Membranas Artificiais , Poliésteres , Aderências Teciduais , Animais , Interações Hidrofóbicas e Hidrofílicas , Ratos , Ceras
7.
J Biomed Opt ; 19(10): 105004, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25291209

RESUMO

In this work, a foldable ring-shaped light-emitting diode (LED) lighting assembly, designed to attach to a rubber wound retractor, is realized and tested through porcine animal experiments. Enabled by the small size and the high efficiency of LED chips, the lighting assembly is compact, flexible, and disposable while providing direct and high brightness lighting for more uniform background illumination in video-assisted thoracic surgery (VATS). When compared with a conventional fiber bundle coupled light source that is usually used in laparoscopy and endoscopy, the much broader solid angle of illumination enabled by the LED assembly allows greatly improved background lighting and imaging quality in VATS.


Assuntos
Iluminação/instrumentação , Cirurgia Torácica Vídeoassistida/instrumentação , Animais , Eletrodos , Desenho de Equipamento , Feminino , Luz , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA