1.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 36(4): 590-595, 2019 Aug 25.
Artigo em Zh | MEDLINE | ID: mdl-31441259

RESUMO

In order to study the mechanical behavior of degeneration and nucleotomy of lumbar intervertebral disc, compression experiments with porcine lumbar intervertebral discs were carried out. The lumbar intervertebral discs with trypsin-treated and nucleus nucleotomy served as the experimental group and the normal discs as the control group. Considering the effects of load magnitude and loading rate, the relationship between stress and strain, instantaneous elastic modulus and creep property of intervertebral disc were obtained. The creep constitutive model was established. The results show that the strain and creep strain of the experimental group increase significantly with the increase of compression load and loading rate, whereas the instantaneous elastic modulus decreases obviously, compared with the control group. It indicates that the effect of load magnitude and loading rate on load-bearing capacity of intervertebral disc after nucleotomy is larger obviously than that of normal disc. The creep behavior of the experimental group can be still predicted by the Kelvin three-parameter solid model. The results will provide theoretical foundation for clinical treatment and postoperative rehabilitation of intervertebral disc disease.


Assuntos
Disco Intervertebral/fisiologia , Disco Intervertebral/cirurgia , Estresse Mecânico , Animais , Fenômenos Biomecânicos , Vértebras Lombares , Suínos , Suporte de Carga
2.
J Mech Behav Biomed Mater ; 138: 105645, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36603526

RESUMO

Locking compression plates (LCP) with asymmetrical holes and polyaxial screws are effective for treating mid-femoral fractures, but are prone to failure in cases of bone nonunion. To understand the failure mechanism of the LCP, this study assessed the material composition, microhardness, metallography, fractography and biomechanical performance of a retrieved LCP used for treating a bone fracture of AO type 32-A1. For the biomechanical assessment, a finite element surgical model implanted with the intact fixation-plate system was constructed to understand the stresses and structural stiffness on the construct. Also, to avoid positioning screws around the bone fracture, different working lengths of the plate (the distance between the two innermost screws) and screw inclinations (±5°, ±10° and ±15°) were investigated. The fracture site of the retrieved LCP was divided into a narrow side and broad side due to the asymmetrical distribution of holes on the plate. The results indicated that the chemical composition and microhardness of the LCP complied with ASTM standards. The fatigue failure was found to originate on the narrow side of the hole, while the broad side showed overloading characteristics of crack growth. When the screws were inserted away from the region of the bone fracture by increasing the working length, the stress of the fixation-plate system decreased. Regardless of the screw insertion angle, the maximum stress on the LCP always appeared on the narrow side, and there was little change in the structural stiffness. However, angling the screws at -10° resulted in the most even stress distribution on the fixation-plate system. In conclusion, the LCP assessed in this study failed by fatigue fracture due to bone nonunion and stress concentration. The narrow side of the LCP was vulnerable to failure and needs to be strengthened. When treating an AO type 32-A1 fracture using an LCP with asymmetrical holes and polyaxial screws, inserting the screws at -10° may reduce the risk of implant failure and positing screws around the fractured area of the bone should be avoided.


Assuntos
Fraturas do Fêmur , Fixação Interna de Fraturas , Humanos , Fixação Interna de Fraturas/métodos , Placas Ósseas , Parafusos Ósseos , Fraturas do Fêmur/cirurgia , Falha de Equipamento , Fenômenos Biomecânicos
3.
Front Surg ; 10: 1112147, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36733891

RESUMO

Background: Component alignment is a crucial factor affecting the clinical outcome of total knee arthroplasty (TKA). Accelerometer-based navigation (ABN) systems were developed to improve the accuracy of alignment during surgery. This study aimed to compare differences in component alignment, clinical outcomes, and surgical duration when using conventional instrumentation (CONI), ABN, and computer navigation (CN) systems. Methods: A comprehensive literature search was carried out using the Web of Science, Embase, PubMed, and Cochrane databases. Articles that met the eligibility criteria were included in the study. Meta-analyses were performed using the Cochrane Collaboration Review Manager based on Cochrane Review Method. The variables used for the analyses were postoperative clinical outcome (PCO), surgical duration, and component alignment, including the hip-knee-ankle (HKA) angle, coronal femoral angle (CFA), coronal tibial angle (CTA), sagittal femoral angle (SFA), sagittal tibial angle (STA), and the outliers for the mentioned angles. The mean difference (MD) was calculated to determine the difference between the surgical techniques for continuous variables and the odds ratio (OR) was used for the dichotomous outcomes. Results: The meta-analysis of the CONI and ABN system included 18 studies involving 2,070 TKA procedures, while the comparison of the ABN and CN systems included 5 studies involving 478 TKA procedures. The results showed that the ABN system provided more accurate component alignment for HKA, CFA, CTA, and SFA and produced fewer outliers for HKA, CFA, CTA, and STA. However, while the ABN system also required a significantly longer surgical time than the CONI approach, there was no statistical difference in PCO for the two systems. For the ABN and CN systems, there was no statistical difference in all variables except for the ABN system having a significantly shorter surgical duration. Conclusion: There was no significant difference in the accuracy of component alignment between the ABN and CN systems, but the ABN approach had a shorter surgical duration and at lower cost. The ABN system also significantly improved the accuracy of component alignment when compared to the CONI approach, although the surgery was longer. However, there was no significant difference in PCO between the CONI, ABN, and CN systems.

4.
J Orthop Translat ; 38: 220-228, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36474854

RESUMO

Background: Stress shielding â€‹(SS) is considered the main mechanical cause of femoral stem loosening after total hip arthroplasty (THA). This study introduces an auxetic lattice femoral stem structure with negative Poisson's ratio that can expand laterally, with the intent of transferring more load to surrounding bone and thereby reducing SS. This study aims to evaluate how the geometry profile of different femoral stems with auxetic structures affects the level of SS. Different re-entrant angles for the auxetic unit cells were also evaluated. Methods: This study assessed three commercial femoral stem designs (Mayo, CLS and Fitmore) and three re-entrant angles for the auxetic structures (60°, 70° and 80°). Nine auxetic femoral stems (three M-type, three C-type and three F-type) and three solid femoral stems (control group) were designed. All femoral stems were implanted into a finite element model of the human femur to compare levels of SS between the auxetic stems and their traditional solid counterparts. Results: The results showed that incorporating an auxetic structure into the stem design caused less SS of the surrounding bone than the control models. The M-type stems had the lowest level of SS, followed by the C-type and F-type stems. A re-entrant angle of 70° for the M-type stem, 80° for the C-type stem and 60° for the F-type stem were the designs most capable of reducing SS. Conclusions: This study found that femoral stems with an auxetic lattice structure caused less SS after THA than comparable solid femoral stems. A femoral stem based on the M-type geometry profile is recommended when designing auxetic femoral stems to minimize SS of surrounding bone. The translational potential of this article: The novel solution provided in this study may serve to increase the survival rate of femoral stems by reducing SS after THA.

5.
Front Bioeng Biotechnol ; 11: 1148914, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37064225

RESUMO

Component alignment is one of the most crucial factors affecting total knee arthroplasty's clinical outcome and survival. This study aimed to investigate how coronal, sagittal, and transverse malalignment affects the mechanical behavior of the tibial insert and to determine a suitable alignment tolerance on the coronal, sagittal, and transverse planes. A finite element model of a cruciate-retaining knee prosthesis was assembled with different joint alignments (-10°, -7°, -5°, -3°, 0°, 3°, 5°, 7°, 10°) to assess the effect of malalignment under gait loading. The results showed that varus or valgus, extension, internal rotation, and excessive external rotation malalignments increased the maximum Von Mises stress and contact pressure on the tibial insert. The mechanical alignment tolerance of the studied prosthesis on the coronal, sagittal, and transverse planes was 3° varus to 3° valgus, 0°-10° flexion, and 0°-5° external rotation, respectively. This study suggests that each prosthesis should include a tolerance range for the joint alignment angle on the three planes, which may be used during surgical planning.

6.
Front Bioeng Biotechnol ; 10: 910311, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35910010

RESUMO

This study aimed to investigate the influence of tibial malrotation on knee kinematics after total knee arthroplasty (TKA). A symmetric fixed-bearing posterior-stabilized prosthesis was implanted in the validated knee model with different rotational alignments of the tibial component (neutral, 3° external rotation, 5° external rotation, 3° internal rotation, and 5° internal rotation). Computational kinematic simulations were used to evaluate the postoperative kinematics of the knee joint including anteroposterior translation femoral condyles and axial rotation of tibial component during 0°-135° knee flexion. The results revealed that the neutral position of the tibial component was not the closest kinematics to the intact knee, the model with 5° external rotation of the tibial component showed the closest lateral condyle translation and tibial axial rotation, and moderate external rotation could improve the kinematics after TKA.

7.
Polymers (Basel) ; 14(23)2022 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-36501675

RESUMO

The wear of the tibial insert is one of the primary factors leading to the failure of total knee arthroplasty. As materials age, their wear performance often degrades. Supplementing highly cross-linked polyethylene (HXLPE) with dodecyl gallate (DG) can improve the oxidation stability of tibial inserts for use in total knee arthroplasty (TKA). This study aimed to evaluate the wear resistance of HXLPE supplemented with DG (HXLPE-DG) tibial inserts before and after accelerated aging. HXLPE-DG tibial inserts were subjected to wear testing of up to 5 million loading cycles according to ISO 14243, and the resulting wear particles were analyzed according to ISO 17853. The wear rate, number, size, and shape of the wear particles were analyzed. The average wear rate of the unaged samples was 4.39 ± 0.75 mg/million cycles and was 3.22 ± 1.49 mg/million cycles for the aged samples. The unaged tibial inserts generated about 2.80 × 107 particles/mL following the wear test, but this was considerably lower for the aged samples at about 1.35 × 107 particles/mL. The average equivalent circle diameter (ECD) of the wear particles from the unaged samples was 0.13 µm (max: 0.80 µm; min: 0.04 µm), and it was 0.14 µm (max: 0.66 µm; min: 0.06 µm) from the aged samples. Moreover, 22.1% of the wear particles from the unaged samples had an aspect ratio (AR) of >4 (slender shape), while this was 15.4% for the aged samples. HXLPE-DG improves the wear performance of the material over time. HXLPE-DG is a novel material that has been demonstrated to have antiaging properties and high wear resistance, making it a promising candidate for use in TKA. Nevertheless, the results are preliminary and will be clarified in further studies.

8.
Front Surg ; 9: 991476, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36311927

RESUMO

Objective: This study aimed to investigate the correlation between component alignment and short-term clinical outcomes after total knee arthroplasty (TKA). Methods: 50 TKA patients from a regional hospital were enrolled in the study. The following component alignments were measured from radiological data acquired within 1 week after surgery: hip-knee-ankle angle (HKA), medial distal femoral angle (MDFA), medial proximal tibial angle (MPTA), femoral flexion-extension angle (FEA), tibial slope angle (TSA), femoral rotational angle (FRA) and tibial rotational angle (TRA). The Hospital for Special Surgery (HSS) knee scoring system was used to assess clinical outcomes after 1 year, with patients being divided into three groups (excellent, good and not good) according to the HSS scores. Difference analysis and linear correlation analysis were used for the statistical analysis. Results: The results showed significant differences in MDFA (p = 0.050) and FEA (p = 0.001) among the three patient groups. It was also found that the total HSS had only a moderate correlation with FEA (r = 0.572, p < 0.001), but FEA had a positive linear correlation with pain scores (r = 0.347, p = 0.013), function scores (r = 0.535, p = 0.000), ROM scores (r = 0.368, p = 0.009), muscle scores (r = 0.354, p = 0.012) and stability scores (r = 0.312, p = 0.028). A larger MDFA was associated with lower FE deformity scores (r = -0.289, p = 0.042) and the TSA had a positive influence on the ROM (r = 0.436, p = 0.002). Also, changes in FRA produced a consequent change in the FE deformity score (r = 0.312, p = 0.027), and the muscle strength scores increased as TRA increased (r = 0.402, p = 0.004). Conclusion: The results show that the FEA plays a significant role in clinical outcomes after TKA. Surgical techniques and tools may need to be improved to accurately adjust the FEA to improve joint functionality and patient satisfaction.

9.
Materials (Basel) ; 14(14)2021 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-34300724

RESUMO

Cobalt-chromium-molybdenum alloy (CoCrMo) and ceramic are the two most common materials for the femoral head in hip joint prostheses, and the acetabular liner is typically made from ultra-high molecular weight polyethylene (UHMWPE), highly cross-linked polyethylene (XLPE), or highly cross-linked polyethylene blended with Vitamin E (VEXLPE). The selection of suitable materials should consider both wear performance and cost-effectiveness. This study compared the wear rate between different friction pairs using a hip joint simulator and then recommended a suitable prosthesis based on the corresponding processing technology and cost. All wear simulations were performed in accordance with ISO 14242, using the same hip joint simulator and same test conditions. This study found that when using the same material for the femoral head, the XLPE and VEXLPE liners had a lower wear rate than the UHMWPE liners, and the wear rate of the XLPE liners increased after blending with Vitamin E (VEXLPE). There was no significant difference in the wear rate of XLPE when using a CoCrMo or ceramic head. Considering the wear rate and cost-effectiveness, a CoCrMo femoral head with an accompanying XLPE liner is recommended as the more suitable combination for hip prostheses.

10.
Polymers (Basel) ; 13(11)2021 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-34199509

RESUMO

BACKGROUND: the wear of tibial insert is still one of primary factors leading to failure of total knee arthroplasty (TKA). Dodecyl gallate (DG) has shown improvements in the oxidation stability of highly cross-linked polyethylene (HXLPE). This study aimed to assess the application of HXLPE supplemented with DG (HXLPE-DG) on the tibial insert in TKA concerning the wear resistance and the potential impact on implant fixation; Methods: tibial inserts made of HXLPE-DG were subjected to a 3 million loading-cycle wear test following ISO 14243-1:2009. The loss of mass and wear rate of the tibial inserts were calculated. The quantity, size,- and shape of wear particles were recorded; Results: the test specimens lost an average mass of 16.00 mg ± 0.94 mg, and were on an average wear rate of 3.92 mg/million cycles ± 0.19 mg/million cycles. The content of wear particles in the calf serum medium was 3.94 × 108 particles/mL ± 3.93 × 107 particles/mL, 96.66% ± 0.77% of the particles had an equivalent circular diameter less than 0.5 µm. The aspect ratio of wear particles was 1.40 (min: 1.01; max: 6.42). CONCLUSIONS: HXLPE-DG displayed advantages over the commonly used materials for tibial inserts and presented the potential of application in TKA.

11.
Front Bioeng Biotechnol ; 9: 673275, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33996784

RESUMO

Kinematically aligned total knee replacements have been shown to better restore physiological kinematics than mechanical alignment and also offer good postoperative satisfaction. The purpose of this study is to evaluate the extent to which an inclined joint line in a kinematically aligned knee can alter the postoperative kinematics. A multi-body dynamic simulation was used to identify kinematic changes in the joint. To accurately compare mechanical alignment, kinematic alignment and a natural knee, a "standard" patient with neutral alignment of the lower extremities was selected for modeling from a joint database. The arthroplasty models in this study were implanted with a single conventional cruciate-retaining prosthesis. Each model was subjected to a flexion movement and the anteroposterior translation of the femoral condyles was collected for kinematic analysis. The results showed that the mechanical alignment model underwent typical paradoxical anterior translation of the femoral condyles. Incorporating an inclined joint line in the model did not prevent the paradoxical anterior translation, but a 3° varus joint line in the kinematic alignment model could reduce the peak value of this motion by about 1 mm. Moreover, the inclined joint line did not restore the motion curve back to within the range of the kinematic curve of the natural knee. The results of this study suggest that an inclined joint line, as in the kinematic alignment model, can slightly suppress paradoxical anterior translation of the femoral condyles, but cannot restore kinematic motions similar to the physiological knee. This finding implies that prostheses intended to be used for kinematic alignment should be designed to optimize knee kinematics with the intention of restoring a physiological motion curve.

12.
Proc Inst Mech Eng H ; 233(8): 858-867, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31203788

RESUMO

The intervertebral disk cushions the load generated by human activity and absorbs energy to keep the spine moving steadily. Vibration condition is one of the important causes of disk degeneration. Creep experiments using the sheep lumbar intervertebral disk were carried out under vibration compression. Regularities of the strain of the disk with time were obtained and compared with those of static load. The influence of vibration frequency and time on the creep properties of the intervertebral disk was analyzed. An intervertebral disk three-parameter solid creep constitutive model considering vibration factors was established and the parameters in the model were identified. The results show that the strain of the lumbar intervertebral disk exhibits an exponential relationship with time and is unrelated to static compression or vibration load. Under the same vibration amplitude, the creep increases with vibration frequency and the relationship between them is nonlinear. The vibration frequency has a significant effect on the strain. The creep rate decreases gradually with time and is obviously influenced by vibration frequency at low vibration amplitudes. The creep prediction results obtained using the constitutive model with the time-varying material parameters are in good agreement with the experimental results. The two elastic moduli in the model decrease with time and the viscosity coefficient increases with time.


Assuntos
Força Compressiva , Disco Intervertebral/fisiologia , Vértebras Lombares/fisiologia , Teste de Materiais/métodos , Vibração , Animais , Fenômenos Biomecânicos , Disco Intervertebral/fisiopatologia , Deslocamento do Disco Intervertebral/fisiopatologia , Vértebras Lombares/fisiopatologia , Teste de Materiais/instrumentação , Ovinos , Suporte de Carga
13.
Med Eng Phys ; 72: 49-54, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31554576

RESUMO

The market for orthopedic implants is growing rapidly with the increasing prevalence of orthopedic diseases in an aging society. Different designs and materials have been developed over the years and have, in general, shown excellent results in pre-clinical testing. However, there have been incidences of serious complications when novel implants or materials are put into clinical use, with some well-known cases being metallosis in patients implanted with metal-on-metal hip replacements and osteolysis from polyethylene wear debris generated in hip and knee joint replacements. Unforeseen factors related to new designs, materials and surgical techniques can lead to different outcomes for pre-clinical testing and clinical use. While often an excellent indicator of a device's performance in clinical settings, pre-clinical testing does sometime fail to predict critical flaws in implant development. This article aims to explore the gaps in the current approach to testing. The ISO international standard of pre-clinical testing should be modified to more adequately capture actual clinical use of the implant and simulate daily activities. This article will also introduce modern methods for implant development, such as FEM, 3D printing and computer-aided orthopedic surgery, which can be widely applied to improve pre-clinical testing procedures and reduce the incidence of surgical malalignment by analyzing biomechanical performance, planning surgical procedure and providing surgical guide.


Assuntos
Ortopedia , Desenho de Prótese/métodos , Humanos , Falha de Prótese
SELEÇÃO DE REFERÊNCIAS